Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Anal Toxicol ; 42(9): 605-616, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29982540

RESUMO

Despite the efforts to prevent the spread of new psychoactive substances (NPS) such as synthetic amphetamine derivatives, it is apparent that newer types of NPS are still emerging on the market in recent years. Due to high potential for their abuse, reliable analytical methods are required to determine these substances in biological samples. The objective of this study was to develop and validate the gas chromatography-mass spectrometric (GC-MS) method for the simultaneous determination of 13 amphetamine-related NPS (amphetamine; AP, 4-fluoroamphetamine; 4FA, methamphamine; MA, 4-fluoromethamphetamine; 4FMA, 4-chloroamphetamine; 4CA, para-methoxyamphetamine; PMA, 4-chloromethamphetamine; 4CMA, 6-(2-aminopropyl)benzofuran; 6APB, 4-methylenedioxyamphetamine; MDA, para-methoxymethamphetamine; PMMA, 6-(2-methylaminopropyl)benzofuran; 6MAPB, 3,4-methylenedioxymethamphetamine; MDMA, 5,6-methylenedioxy-2-aminoindane; MDAI) in urine. The analytes were extracted at pH 7.4 by liquid-liquid extraction prior to their trifluoroacetyl derivatives and then analyzed by GC-MS. The validation parameters included selectivity, linearity, lower limits of quantification (LLOQ), intra and interday precision and accuracy, recovery and stability. The linear ranges were 2-100 ng/mL for AP, 4FA, 4FMA, 4CA, PMA, 6APB, MDA, and MDAI, 2-250 ng/mL for 4CMA, PMMA, and 6MAPB and 25-1,000 ng/mL for MA and MDMA, with acceptable coefficients of determination (r2 > 0.9963). The intra and interday precision were within 11.9 and 12.5%, while the intra and interday accuracies ranged from -10.6% to 13.0% and -11.0% to 6.8% for the nominal concentration at all studied levels, respectively. The LLOQs for each analyte were 2.0-25 ng/mL. The recoveries ranged from 69.3% to 96.4%. The short- and long-term variations of the analytes in urine were lower than 8.5 and 12.7%, indicating that the analytes are stable at least for 16 h at room temperature and for 7 days at 4°C, respectively. The applicability of the method was examined by analyzing urine samples from drug abusers and was determined to be effective for detecting multiple drug use.


Assuntos
Transtornos Relacionados ao Uso de Anfetaminas/urina , Anfetaminas/urina , Drogas Desenhadas/análise , Toxicologia Forense/métodos , Psicotrópicos/urina , Detecção do Abuso de Substâncias/métodos , Toxicologia Forense/instrumentação , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Limite de Detecção , Reprodutibilidade dos Testes , Detecção do Abuso de Substâncias/instrumentação
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1029-1030: 22-27, 2016 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-27398632

RESUMO

Nonmedical use of prescription stimulants such as phentermine (PT) has been regulated by law enforcement authorities due to its euphorigenic and relaxing effects. Due to high potential for its abuse, reliable analytical methods were required to detect and identify PT and its metabolite in biological samples. Thus a dilute and shoot liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for simultaneous determination of PT, N-hydroxyphentermine (NHOPT) and mephentermine (MPT) in urine. A 5µL aliquot of diluted urine was injected into the LC-MS/MS system. Chromatographic separation was performed by reversed-phase C18 column with gradient elution for all analytes within 5min. Identification and quantification were based on multiple reaction monitoring (MRM) detection. Linear least-squares regression with a 1/x(2) weighting factor was used to generate a calibration curve and the assay was linear from 50 to 15000ng/mL (PT and MPT) and 5 to 750ng/mL (NHOPT). The intra- and inter-day precisions were within 8.9% while the intra- and inter-day accuracies ranged from -6.2% to 11.2%. The limits of quantification were 3.5ng/mL (PT), 1.5ng/mL (NHOPT) and 1.0ng/mL (MPT). Method validation requirements for selectivity, dilution integrity, matrix effect and stability were satisfied. The applicability of the developed method was examined by analyzing urine samples from drug abusers.


Assuntos
Estimulantes do Sistema Nervoso Central/urina , Cromatografia Líquida de Alta Pressão/métodos , Mefentermina/urina , Fentermina/análogos & derivados , Fentermina/urina , Detecção do Abuso de Substâncias/métodos , Simpatomiméticos/urina , Humanos , Limite de Detecção , Espectrometria de Massas em Tandem/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...