Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Int J Mol Sci ; 25(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38731885

RESUMO

Lysine is an essential amino acid that cannot be synthesized in humans. Rice is a global staple food for humans but has a rather low lysine content. Identification of the quantitative trait nucleotides (QTNs) and genes underlying lysine content is crucial to increase lysine accumulation. In this study, five grain and three leaf lysine content datasets and 4,630,367 single nucleotide polymorphisms (SNPs) of 387 rice accessions were used to perform a genome-wide association study (GWAS) by ten statistical models. A total of 248 and 71 common QTNs associated with grain/leaf lysine content were identified. The accuracy of genomic selection/prediction RR-BLUP models was up to 0.85, and the significant correlation between the number of favorable alleles per accession and lysine content was up to 0.71, which validated the reliability and additive effects of these QTNs. Several key genes were uncovered for fine-tuning lysine accumulation. Additionally, 20 and 30 QTN-by-environment interactions (QEIs) were detected in grains/leaves. The QEI-sf0111954416 candidate gene LOC_Os01g21380 putatively accounted for gene-by-environment interaction was identified in grains. These findings suggested the application of multi-model GWAS facilitates a better understanding of lysine accumulation in rice. The identified QTNs and genes hold the potential for lysine-rich rice with a normal phenotype.


Assuntos
Estudo de Associação Genômica Ampla , Lisina , Oryza , Polimorfismo de Nucleotídeo Único , Locos de Características Quantitativas , Oryza/genética , Oryza/metabolismo , Lisina/metabolismo , Estudo de Associação Genômica Ampla/métodos , Fenótipo , Interação Gene-Ambiente , Grão Comestível/genética , Grão Comestível/metabolismo
2.
Biochem Biophys Res Commun ; 694: 149389, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38128383

RESUMO

PURPOSE: To examine whether and how carbohydrate response element-binding protein (ChREBP) plays a role in diabetic retinopathy. METHODS: Western blotting was used to detect ChREBP expression and location following high glucose stimulation of Human Retinal Microvascular Endothelial Cells (HRMECs). Flow cytometry, TUNEL staining, and western blotting were used to evaluate apoptosis following ChREBP siRNA silencing. Cell scratch, transwell migration, and tube formation assays were used to determine cell migration and angiogenesis. Diabetic models for wild-type (WT) and ChREBP knockout (ChKO) mice were developed. Retinas of WT and ChKO animals were cultivated in vitro with vascular endothelial growth factor + high glucose to assess neovascular development. RESULTS: ChREBP gene knockdown inhibited thioredoxin-interacting protein and NOD-like receptor family pyrin domain containing protein 3 expression in HRMECs, which was caused by high glucose stimulation, reduced apoptosis, hindered migration, and tube formation, and repressed AKT/mTOR signaling pathway activation. Compared with WT mice, ChKO mice showed suppressed high glucose-induced alterations in retinal structure, alleviated retinal vascular leakage, and reduced retinal neovascularization. CONCLUSIONS: ChREBP deficiency decreased high glucose-induced apoptosis, migration, and tube formation in HRMECs as well as structural and angiogenic responses in the mouse retina; thus, it is a potential therapeutic target for diabetic retinopathy.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Animais , Humanos , Camundongos , Diabetes Mellitus/metabolismo , Retinopatia Diabética/metabolismo , Células Endoteliais/metabolismo , Glucose/metabolismo , Retina/metabolismo , Fator A de Crescimento do Endotélio Vascular/genética , Fator A de Crescimento do Endotélio Vascular/metabolismo
3.
Front Plant Sci ; 14: 1229457, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37954993

RESUMO

Introduction: Flax (Linum usitatissimum L.) is an economically important crop due to its oil and fiber. However, it is prone to various diseases, including pasmo caused by the fungus Septoria linicola. Methods: In this study, we conducted field evaluations of 445 flax accessions over a five-year period (2012-2016) to assess their resistance to pasmo A total of 246,035 single nucleotide polymorphisms (SNPs) were used for genetic analysis. Four statistical models, including the single-locus model GEMMA and the multi-locus models FarmCPU, mrMLM, and 3VmrMLM, were assessed to identify quantitative trait nucleotides (QTNs) associated with pasmo resistance. Results: We identified 372 significant QTNs or 132 tag QTNs associated with pasmo resistance from five pasmo resistance datasets (PAS2012-PAS2016 and the 5-year average, namely PASmean) and three genotypic datasets (the all SNPs/ALL, the gene-based SNPs/GB and the RGA-based SNPs/RGAB). The tag QTNs had R2 values of 0.66-16.98% from the ALL SNP dataset, 0.68-20.54%from the GB SNP dataset, and 0.52-22.42% from the RGAB SNP dataset. Of these tag QTNs, 93 were novel. Additionally, 37 resistance gene analogs (RGAs)co-localizing with 39 tag QTNs were considered as potential candidates for controlling pasmo resistance in flax and 50 QTN-by-environment interactions(QEIs) were identified to account for genes by environmental interactions. Nine RGAs were predicted as candidate genes for ten QEIs. Discussion: Our results suggest that pasmo resistance in flax is polygenic and potentially influenced by environmental factors. The identified QTNs provide potential targets for improving pasmo resistance in flax breeding programs. This study sheds light on the genetic basis of pasmo resistance and highlights the importance of considering both genetic and environmental factors in breeding programs for flax.

4.
Plants (Basel) ; 12(16)2023 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-37631180

RESUMO

Rice (Oryza sativa L.) is a globally important food source providing carbohydrates, amino acids, and dietary fiber for humans and livestock. The branched-chain amino acid (BCAA) level is a complex trait related to the nutrient quality of rice. However, the genetic mechanism underlying the BCAA (valine, leucine, and isoleucine) accumulation in rice grains remains largely unclear. In this study, the grain BCAA contents and 239,055 SNPs of a diverse panel containing 422 rice accessions were adopted to perform a genome-wide association study (GWAS) using a recently proposed 3VmrMLM model. A total of 357 BCAA-content-associated main-effect quantitative trait nucleotides (QTNs) were identified from 15 datasets (12 BCAA content datasets and 3 BLUP datasets of BCAA). Furthermore, the allelic variation of two novel candidate genes, LOC_Os01g52530 and LOC_Os06g15420, responsible for the isoleucine (Ile) content alteration were identified. To reveal the genetic basis of the potential interactions between the gene and environmental factor, 53 QTN-by-environment interactions (QEIs) were detected using the 3VmrMLM model. The LOC_Os03g24460, LOC_Os01g55590, and LOC_Os12g31820 were considered as the candidate genes potentially contributing to the valine (Val), leucine (Leu), and isoleucine (Ile) accumulations, respectively. Additionally, 10 QTN-by-QTN interactions (QQIs) were detected using the 3VmrMLM model, which were putative gene-by-gene interactions related to the Leu and Ile contents. Taken together, these findings suggest that the implementation of the 3VmrMLM model in a GWAS may provide new insights into the deeper understanding of BCAA accumulation in rice grains. The identified QTNs/QEIs/QQIs serve as potential targets for the genetic improvement of rice with high BCAA levels.

5.
Cereb Cortex ; 33(9): 5082-5096, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-36288912

RESUMO

Advances in Magnetic Resonance Imaging hardware and methodologies allow for promoting the cortical morphometry with submillimeter spatial resolution. In this paper, we generated 3D self-enhanced high-resolution (HR) MRI imaging, by adapting 1 deep learning architecture, and 3 standard pipelines, FreeSurfer, MaCRUISE, and BrainSuite, have been collectively employed to evaluate the cortical thickness. We systematically investigated the differences in cortical thickness estimation for MRI sequences at multiresolution homologously originated from the native image. It has been revealed that there systematically exhibited the preferences in determining both inner and outer cortical surfaces at higher resolution, yielding most deeper cortical surface placements toward GM/WM or GM/CSF boundaries, which directs a consistent reduction tendency of mean cortical thickness estimation; on the contrary, the lower resolution data will most probably provide a more coarse and rough evaluation in cortical surface reconstruction, resulting in a relatively thicker estimation. Although the differences of cortical thickness estimation at the diverse spatial resolution varied with one another, almost all led to roughly one-sixth to one-fifth significant reduction across the entire brain at the HR, independent to the pipelines we applied, which emphasizes on generally coherent improved accuracy in a data-independent manner and endeavors to cost-efficiency with quantitative opportunities.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Córtex Cerebral
6.
Front Plant Sci ; 13: 1048860, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36420042

RESUMO

Rice (Oryza sativa L.) is one of the important staple foods for human consumption and livestock use. As a complex quality trait, free amino acid (FAA) content in rice is of nutritional importance. To dissect the genetic mechanism of FAA level, five amino acids' (Val, Leu, Ile, Arg, and Trp) content and 4,325,832 high-quality SNPs of 448 rice accessions were used to conduct genome-wide association studies (GWAS) with nine different methods. Of these methods, one single-locus method (GEMMA), seven multi-locus methods (mrMLM, pLARmEB, FASTmrEMMA, pKWmEB, FASTmrMLM, ISIS EM-BLASSO, and FarmCPU), and the recent released 3VmrMLM were adopted for methodological comparison of quantitative trait nucleotide (QTN) detection and identification of stable quantitative trait nucleotide loci (QTLs). As a result, 987 QTNs were identified by eight multi-locus GWAS methods; FASTmrEMMA detected the most QTNs (245), followed by 3VmrMLM (160), and GEMMA detected the least QTNs (0). Among 88 stable QTLs identified by the above methods, 3VmrMLM has some advantages, such as the most common QTNs, the highest LOD score, and the highest proportion of all detected stable QTLs. Around these stable QTLs, candidate genes were found in the GO classification to be involved in the primary metabolic process, biosynthetic process, and catalytic activity, and shown in KEGG analysis to have participated in metabolic pathways, biosynthesis of amino acids, and tryptophan metabolism. Natural variations of candidate genes resulting in the content alteration of five FAAs were identified in this association panel. In addition, 95 QTN-by-environment interactions (QEIs) of five FAA levels were detected by 3VmrMLM only. GO classification showed that the candidate genes got involved in the primary metabolic process, transport, and catalytic activity. Candidate genes of QEIs played important roles in valine, leucine, and isoleucine degradation (QEI_09_03978551 and candidate gene LOC_Os09g07830 in the Leu dataset), tryptophan metabolism (QEI_01_00617184 and candidate gene LOC_Os01g02020 in the Trp dataset), and glutathione metabolism (QEI_12_09153839 and candidate gene LOC_Os12g16200 in the Arg dataset) pathways through KEGG analysis. As an alternative of the multi-locus GWAS method, these findings suggested that the application of 3VmrMLM may provide new insights into better understanding FAA accumulation and facilitate the molecular breeding of rice with high FAA level.

7.
BMC Ophthalmol ; 22(1): 161, 2022 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-35392841

RESUMO

BACKGROUND: To evaluate the effects of 0.02% and 0.01% atropine eye drops on ocular and corneal astigmatism over 2 years. METHODS: A prospective clinic-controlled trail. The cohort study assessed 400 myopic children and divided them into three groups: 138 and 142 children were randomized to use either 0.02% or 0.01% atropine eye drops, respectively. They wore single-vision (SV) spectacles, with one drop of atropine applied to both eyes once nightly. Control children (n = 120) only wore SV spectacles. Spherical equivalent refractive errors (SER) and corneal curvature were measured every 4 months. The SER and corneal curvature were assessed by cycloplegic autorefraction and IOLMaster. Ocular and corneal astigmatism were calculated by Thibos vector analysis and then split into its power vector components, J0 (with-the-rule astigmatism) and J45 (oblique). RESULTS: After 2 years, the ocular astigmatism increased by -0.38 ± 0.29 D, -0.47 ± 0.38 D, -0.41 ± 0.35 D in the 0.02%, 0.01% atropine groups and control group, respectively (p = 0.15). The corresponding corneal astigmatism increased by -0.20 ± 0.34 D, -0.28 ± 0.35 D and -0.26 ± 0.26 D (p = 0.18). The ocular astigmatism J0 increased by 0.19 ± 0.28 D, 0.22 ± 0.36 D, 0.18 ± 0.31 D in the 0.02% atropine, 0.01% atropine and control groups, respectively (p = 0.65). The corresponding corneal astigmatism J0 increased by -0.05 ± 0.34 D, -0.11 ± 0.37 D and -0.13 ± 0.30 D (p = 0.23). There was a small but significant increase in ocular astigmatism (including J0) (all P < 0.05), but there were no changes in the ocular astigmatism J45 and corneal astigmatism (including J0 and J45) in the three groups over time (all p > 0.05). However, there were no significant differences in the changes in ocular astigmatism (including J0) among the three groups. CONCLUSIONS: Treatment with 0.02% and 0.01% atropine had no clinically significant effect on ocular and corneal astigmatism over 2 years. TRIAL REGISTRATION: The First Affiliated Hospital of Zhengzhou University, ChiCTR-IPD-16008844 . Registered 14/07/2016.


Assuntos
Astigmatismo , Doenças da Córnea , Astigmatismo/tratamento farmacológico , Atropina/uso terapêutico , Criança , Estudos de Coortes , Córnea , Humanos , Soluções Oftálmicas , Estudos Prospectivos , Refração Ocular
8.
IEEE Trans Med Imaging ; 41(6): 1383-1399, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35020591

RESUMO

The interpretation and analysis of Magnetic resonance imaging (MRI) benefit from high spatial resolution. Unfortunately, direct acquisition of high spatial resolution MRI is time-consuming and costly, which increases the potential for motion artifact, and suffers from reduced signal-to-noise ratio (SNR). Super-resolution reconstruction (SRR) is one of the most widely used methods in MRI since it allows for the trade-off between high spatial resolution, high SNR, and reduced scan times. Deep learning has emerged for improved SRR as compared to conventional methods. However, current deep learning-based SRR methods require large-scale training datasets of high-resolution images, which are practically difficult to obtain at a suitable SNR. We sought to develop a methodology that allows for dataset-free deep learning-based SRR, through which to construct images with higher spatial resolution and of higher SNR than can be practically obtained by direct Fourier encoding. We developed a dataset-free learning method that leverages a generative neural network trained for each specific scan or set of scans, which in turn, allows for SRR tailored to the individual patient. With the SRR from three short duration scans, we achieved high quality brain MRI at an isotropic spatial resolution of 0.125 cubic mm with six minutes of imaging time for T2 contrast and an average increase of 7.2 dB (34.2%) in SNR to these short duration scans. Motion compensation was achieved by aligning the three short duration scans together. We assessed our technique on simulated MRI data and clinical data acquired from 15 subjects. Extensive experimental results demonstrate that our approach achieved superior results to state-of-the-art methods, while in parallel, performed at reduced cost as scans delivered with direct high-resolution acquisition.


Assuntos
Imageamento por Ressonância Magnética , Redes Neurais de Computação , Encéfalo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Cintilografia , Razão Sinal-Ruído
9.
J Neuroimaging ; 32(1): 68-79, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34506677

RESUMO

BACKGROUND AND PURPOSE: Super-resolutionreconstruction (SRR) can be used to reconstruct 3-dimensional (3D) high-resolution (HR) volume from several 2-dimensional (2D) low-resolution (LR) stacks of MRI slices. The purpose is to compare lengthy 2D T2-weighted HR image acquisition of neonatal subjects with 3D SRR from several LR stacks in terms of image quality for clinical and morphometric assessments. METHODS: LR brain images were acquired from neonatal subjects to reconstruct isotropic 3D HR volumes by using SRR algorithm. Quality assessments were done by an experienced pediatric radiologist using scoring criteria adapted to newborn anatomical landmarks. The Wilcoxon signed-rank test was used to compare scoring results between HR and SRR images. For quantitative assessments, morphology-based segmentation was performed on both HR and SRR images and Dice coefficients between the results were computed. Additionally, simple linear regression was performed to compare the tissue volumes. RESULTS: No statistical difference was found between HR and SRR structural scores using Wilcoxon signed-rank test (p = .63, Z = .48). Regarding segmentation results, R2 values for the volumes of gray matter, white matter, cerebrospinal fluid, basal ganglia, cerebellum, and total brain volume including brain stem ranged between .95 and .99. Dice coefficients between the segmented regions from HR and SRR ranged between .83 ± .04 and .96 ± .01. CONCLUSION: Qualitative and quantitative assessments showed that 3D SRR of several LR images produces images that are of comparable quality to standard 2D HR image acquisition for healthy neonatal imaging without loss of anatomical details with similar edge definition allowing the detection of fine anatomical structures and permitting comparable morphometric measurement.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Algoritmos , Encéfalo/diagnóstico por imagem , Criança , Humanos , Imageamento Tridimensional/métodos , Recém-Nascido , Imageamento por Ressonância Magnética/métodos , Neuroimagem
10.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-928398

RESUMO

OBJECTIVE@#To assess the practical and health economical values of non-invasive prenatal test (NIPT) in Changsha Municipal Public Welfare Program.@*METHODS@#A retrospective analysis was carried out on 149 165 women undergoing NIPT test from April 9, 2018 to December 31, 2019. For pregnant women with high risks, invasive prenatal diagnosis and follow-up of pregnancy outcome were conducted. The cost-benefit of NIPT for Down syndrome was analyzed.@*RESULTS@#NIPT was carried out for 149 165 pregnant women and succeeded in 148 749 cases (99.72%), for which outcome were available in 148 538 (99.86%). 90% of pregnant women from the region accepted the screening with NIPT. 415 (0.27%) were diagnosed as high risk. Among these, 381 (91.81%) accepted amniocentesis, which led to the diagnosis of 212 cases of trisomy 21 (PPV=85.14%), 41 cases with trisomy 18 (PPV=48.81%) and 10 cases with trisomy 13 (PPV=20.83%). The sensitivity and specificity of NIPT for trisomy 21, trisomy 18 and trisomy 13 were (97.70%, 99.98%), (97.62%, 9.97%) and (100%, 99.97%), respectively. In addition, 213 and 30 cases were diagnosed with sex chromosomal aneuploidies (PPV=46.2%) and other autosomal anomalies (PPV=16.57%), respectively. For Down syndrome screening, the cost and benefit of the project was 120.79 million yuan and 1,056.95 million yuan, respectively. The cost-benefit ratio was 1: 8.75, and safety index was 0.0035.@*CONCLUSION@#NIPT is a highly accurate screening test for trisomy 21, which was followed by trisomy 18 and sex chromosomal aneuploidies, while it was less accurate for other autosomal aneuploidies. The application of NIPT screening has a high health economical value.


Assuntos
Feminino , Humanos , Gravidez , Aneuploidia , Análise Custo-Benefício , Teste Pré-Natal não Invasivo , Estudos Retrospectivos , Síndrome da Trissomía do Cromossomo 18/genética
11.
Artigo em Inglês | MEDLINE | ID: mdl-34713277

RESUMO

Spatial resolution plays a critically important role in MRI for the precise delineation of the imaged tissues. Unfortunately, acquisitions with high spatial resolution require increased imaging time, which increases the potential of subject motion, and suffers from reduced signal-to-noise ratio (SNR). Super-resolution reconstruction (SRR) has recently emerged as a technique that allows for a trade-off between high spatial resolution, high SNR, and short scan duration. Deconvolution-based SRR has recently received significant interest due to the convenience of using the image space. The most critical factor to succeed in deconvolution is the accuracy of the estimated blur kernels that characterize how the image was degraded in the acquisition process. Current methods use handcrafted filters, such as Gaussian filters, to approximate the blur kernels, and have achieved promising SRR results. As the image degradation is complex and varies with different sequences and scanners, handcrafted filters, unfortunately, do not necessarily ensure the success of the deconvolution. We sought to develop a technique that enables accurately estimating blur kernels from the image data itself. We designed a deep architecture that utilizes an adversarial scheme with a generative neural network against its degradation counterparts. This design allows for the SRR tailored to an individual subject, as the training requires the scan-specific data only, i.e., it does not require auxiliary datasets of high-quality images, which are practically challenging to obtain. With this technique, we achieved high-quality brain MRI at an isotropic resolution of 0.125 cubic mm with six minutes of imaging time. Extensive experiments on both simulated low-resolution data and clinical data acquired from ten pediatric patients demonstrated that our approach achieved superior SRR results as compared to state-of-the-art deconvolution-based methods, while in parallel, at substantially reduced imaging time in comparison to direct high-resolution acquisitions.

12.
Front Neurosci ; 15: 636268, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34220414

RESUMO

The brain of neonates is small in comparison to adults. Imaging at typical resolutions such as one cubic mm incurs more partial voluming artifacts in a neonate than in an adult. The interpretation and analysis of MRI of the neonatal brain benefit from a reduction in partial volume averaging that can be achieved with high spatial resolution. Unfortunately, direct acquisition of high spatial resolution MRI is slow, which increases the potential for motion artifact, and suffers from reduced signal-to-noise ratio. The purpose of this study is thus that using super-resolution reconstruction in conjunction with fast imaging protocols to construct neonatal brain MRI images at a suitable signal-to-noise ratio and with higher spatial resolution than can be practically obtained by direct Fourier encoding. We achieved high quality brain MRI at a spatial resolution of isotropic 0.4 mm with 6 min of imaging time, using super-resolution reconstruction from three short duration scans with variable directions of slice selection. Motion compensation was achieved by aligning the three short duration scans together. We applied this technique to 20 newborns and assessed the quality of the images we reconstructed. Experiments show that our approach to super-resolution reconstruction achieved considerable improvement in spatial resolution and signal-to-noise ratio, while, in parallel, substantially reduced scan times, as compared to direct high-resolution acquisitions. The experimental results demonstrate that our approach allowed for fast and high-quality neonatal brain MRI for both scientific research and clinical studies.

13.
IEEE Trans Comput Imaging ; 7: 1240-1253, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35252479

RESUMO

The trade-off between image resolution, signal-to-noise ratio (SNR), and scan time in any magnetic resonance imaging (MRI) protocol is inevitable and unavoidable. Super-resolution reconstruction (SRR) has been shown effective in mitigating these factors, and thus, has become an important approach in addressing the current limitations of MRI. In this work, we developed a novel, image-based MRI SRR approach based on anisotropic acquisition schemes, which utilizes a new gradient guidance regularization method that guides the high-resolution (HR) reconstruction via a spatial gradient estimate. Further, we designed an analytical solution to propagate the spatial gradient fields from the low-resolution (LR) images to the HR image space and exploited these gradient fields over multiple scales with a dynamic update scheme for more accurate edge localization in the reconstruction. We also established a forward model of image formation and inverted it along with the proposed gradient guidance. The proposed SRR method allows subject motion between volumes and is able to incorporate various acquisition schemes where the LR images are acquired with arbitrary orientations and displacements, such as orthogonal and through-plane origin-shifted scans. We assessed our proposed approach on simulated data as well as on the data acquired on a Siemens 3T MRI scanner containing 45 MRI scans from 14 subjects. Our experimental results demonstrate that our approach achieved superior reconstructions compared to state-of-the-art methods, both in terms of local spatial smoothness and edge preservation, while, in parallel, at reduced, or at the same cost as scans delivered with direct HR acquisition.

14.
Med Image Comput Comput Assist Interv ; 12262: 136-146, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33163994

RESUMO

In MRI practice, it is inevitable to appropriately balance between image resolution, signal-to-noise ratio (SNR), and scan time. It has been shown that super-resolution reconstruction (SRR) is effective to achieve such a balance, and has obtained better results than direct high-resolution (HR) acquisition, for certain contrasts and sequences. The focus of this work was on constructing images with spatial resolution higher than can be practically obtained by direct Fourier encoding. A novel learning approach was developed, which was able to provide an estimate of the spatial gradient prior from the low-resolution (LR) inputs for the HR reconstruction. By incorporating the anisotropic acquisition schemes, the learning model was trained over the LR images themselves only. The learned gradients were integrated as prior knowledge into a gradient-guided SRR model. A closed-form solution to the SRR model was developed to obtain the HR reconstruction. Our approach was assessed on the simulated data as well as the data acquired on a Siemens 3T MRI scanner containing 45 MRI scans from 15 subjects. The experimental results demonstrated that our approach led to superior SRR over state-of-the-art methods, and obtained better images at lower or the same cost in scan time than direct HR acquisition.

15.
Am J Sports Med ; 48(14): 3515-3524, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33141598

RESUMO

BACKGROUND: The biomechanical and tendon-bone incorporation properties of allograft-augmented hybrid grafts for anterior cruciate ligament (ACL) reconstruction compared with traditional autografts are unknown. HYPOTHESIS: Using an autograft for ACL reconstruction yields better results on biomechanical testing, radiographic analysis, and histological evaluation versus using a hybrid graft. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 66 adult male Sprague Dawley rats underwent unilateral ACL reconstruction with an autograft (AT group; n = 33) or a hybrid graft (HB group; n = 33). The grafts used in both groups were harvested from the peroneus longus tendon and were fixed by suturing to the surrounding periosteum. Samples were harvested for biomechanical testing, micro-computed tomography (CT), and histological evaluation at 4, 8, and 12 weeks postoperatively. Bone tunnels on the femoral and tibial sides were divided into 3 subregions: intra-articular (IA), midtunnel (MT), and extra-articular (EA). A cylinder-like volume of interest in the bone tunnel and a tubular-like volume of interest around the bone tunnel were used to evaluate new bone formation and bone remodeling, respectively, via micro-CT. RESULTS: In the AT group, there were significantly higher failure loads and stiffness at 8 weeks (failure load: 3.04 ± 0.40 vs 2.09 ± 0.54 N, respectively; P = .006) (stiffness: 3.43 ± 0.56 vs 1.75 ± 0.52 N/mm, respectively; P < .001) and 12 weeks (failure load: 9.10 ± 1.13 vs 7.14 ± 0.94 N, respectively; P = .008) (stiffness: 4.45 ± 0.75 vs 3.36 ± 0.29 N/mm, respectively; P = .008) than in the HB group. With regard to new bone formation in the bone tunnel, in the AT group, the bone volume/total volume (BV/TV) was significantly higher than in the HB group on the tibial side at 8 weeks (IA: 22.21 ± 4.98 vs 5.16 ± 3.98, respectively; P < .001) (EA: 19.66 ± 7.19 vs 10.85 ± 2.16, respectively; P = .030) and 12 weeks (IA: 30.50 ± 5.04 vs 17.11 ± 7.31, respectively; P = .010) (MT: 21.15 ± 2.58 vs 15.55 ± 4.48, respectively; P = .041) (EA: 20.75 ± 3.87 vs 10.64 ± 3.94, respectively; P = .003). With regard to bone remodeling around the tunnel, the BV/TV was also significantly higher on the tibial side at 8 weeks (MT: 33.17 ± 8.05 vs 15.21 ± 7.60, respectively; P = .007) (EA: 25.19 ± 6.38 vs 13.94 ± 7.10, respectively; P = .030) and 12 weeks (IA: 69.46 ± 4.45 vs 47.80 ± 6.16, respectively; P < .001) (MT: 33.15 ± 3.88 vs 13.76 ± 4.07, respectively; P < .001) in the AT group than in the HB group. Sharpey-like fibers had formed at 8 weeks in the AT group. A large number of fibroblasts withdrew at 12 weeks. In the AT group, the width of the interface was significantly narrower at 4 weeks (85.86 ± 17.49 vs 182.97 ± 14.35 µm, respectively; P < .001), 8 weeks (58.86 ± 10.99 vs 90.15 ± 11.53 µm, respectively; P = .002), and 12 weeks (42.70 ± 7.96 vs 67.29 ± 6.55 µm, respectively; P = .001) than in the HB group. CONCLUSION: Using an autograft for ACL reconstruction may result in improved biomechanical properties and tendon-bone incorporation compared with a hybrid graft. CLINICAL RELEVANCE: Augmenting small autografts with allograft tissue may result in decreased biomechanical performance and worse tendon-bone incorporation, increasing the risk of graft failure.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Tendões/transplante , Animais , Ligamento Cruzado Anterior/diagnóstico por imagem , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Autoenxertos , Masculino , Ratos , Ratos Sprague-Dawley , Microtomografia por Raio-X
16.
Neuroimage ; 223: 117280, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32853815

RESUMO

Functional MRI (fMRI) is extremely challenging to perform in subjects who move because subject motion disrupts blood oxygenation level dependent (BOLD) signal measurement. It has become common to use retrospective framewise motion detection and censoring in fMRI studies to eliminate artifacts arising from motion. Data censoring results in significant loss of data and statistical power unless the data acquisition is extended to acquire more data not corrupted by motion. Acquiring more data than is necessary leads to longer than necessary scan duration, which is more expensive and may lead to additional subject non-compliance. Therefore, it is well established that real-time prospective motion monitoring is crucial to ensure data quality and reduce imaging costs. In addition, real-time monitoring of motion allows for feedback to the operator and the subject during the acquisition, to enable intervention to reduce the subject motion. The most widely used form of motion monitoring for fMRI is based on volume-to-volume registration (VVR), which quantifies motion as the misalignment between subsequent volumes. However, motion is not constrained to occur only at the boundaries of volume acquisition, but instead may occur at any time. Consequently, each slice of an fMRI acquisition may be displaced by motion, and assessment of whole volume to volume motion may be insensitive to both intra-volume and inter-volume motion that is revealed by displacement of the slices. We developed the first slice-by-slice self-navigated motion monitoring system for fMRI by developing a real-time slice-to-volume registration (SVR) algorithm. Our real-time SVR algorithm, which is the core of the system, uses a local image patch-based matching criterion along with a Levenberg-Marquardt optimizer, all accelerated via symmetric multi-processing, with interleaved and simultaneous multi-slice acquisition schemes. Extensive experimental results on real motion data demonstrated that our fast motion monitoring system, named Slice Localization Integrated MRI Monitoring (SLIMM), provides more accurate motion measurements than a VVR based approach. Therefore, SLIMM offers improved online motion monitoring which is particularly important in fMRI for challenging patient populations. Real-time motion monitoring is crucial for online data quality control and assurance, for enabling feedback to the subject and the operator to act to mitigate motion, and in adaptive acquisition strategies that aim to ensure enough data of sufficient quality is acquired without acquiring excess data.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Adolescente , Adulto , Algoritmos , Artefatos , Criança , Pré-Escolar , Movimentos da Cabeça , Humanos , Razão Sinal-Ruído , Adulto Jovem
17.
IEEE Trans Med Imaging ; 39(5): 1511-1523, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31714218

RESUMO

Surgical resection is the main clinical method for the treatment of bone tumors. A critical procedure for bone tumor resection is to plan a set of cut planes that enable resecting the bone tumor with a safe margin while preserving the maximum amount of healthy bone. Currently, the surgeons rely on manual methods to plan the cut planes, which highly depend on the surgeons' experiences and have been demonstrated to be error-prone, and in turn, increase the recurrence rate or resect much healthy bone. This study targets on improving the precision of cut plane planning for the image guided pelvis tumor resection surgeries. A semi-automatic approach to cut plane planning was proposed via a coarse-to-fine strategy. It can efficiently identify a dangerous region in the 3D space, which contains the bone tumor and its surrounding normal tissue with a safe margin. By projecting the dangerous region into an appropriate 2D space, a segmented boundary-constrained linear regression method was leveraged to plan a set of 3D cut planes that ensure the minimum area of the resected specimen in the 2D space while having the dangerous region cleared. Further, a coarse-to-fine 3D cut plane planning method was developed by incorporating a 3D cut plane refinement scheme with our 2D planning method. Extensive experiments, on the surgical data from nine previous pelvis tumor resection surgeries, demonstrated that our proposed approach substantially improved the localization precision of cut planes ( ) and decreased the amount of resected specimen ( ), as compared to the manual method.


Assuntos
Neoplasias Pélvicas , Cirurgia Assistida por Computador , Humanos , Imageamento Tridimensional , Recidiva Local de Neoplasia , Osteotomia , Pelve/diagnóstico por imagem , Pelve/cirurgia
18.
Artigo em Inglês | MEDLINE | ID: mdl-32832937

RESUMO

In this work, we proposed a novel image-based MRI super-resolution reconstruction (SRR) approach based on anisotropic acquisition schemes. We achieved superior reconstruction to state-of-the-art work by introducing a new multi-scale gradient field prior that guides the reconstruction of the high-resolution (HR) image. The prior improves both spatial smoothness and edge preservation. The inverse of the forward model of image formation is used to propagate the gradient guidance from the low-resolution (LR) images to the HR image space. The gradient fields over multiple scales were exploited for more accurate edge localization in the reconstruction. The proposed SRR allows inter-volume motion during the MRI scans and can incorporate with the LR images with arbitrary orientations and displacements in the frequency space, such as orthogonal and origin-shifted scans. The proposed approach was evaluated on the synthetic data as well as the data acquired on a Siemens 3T MRI scanner containing 45 MRI scans from 14 subjects. The evaluation results demonstrate that our proposed prior leads to improved SRR as compared to state-of-the-art priors, and that the proposed SRR obtains better results at lower or the same cost in scan time than direct HR acquisition. In particular, the anatomical structures of hippocampus can be clearly shown in our reconstructed images. This is a significant improvement for the in vivo studies of the hippocampus.

19.
IEEE Trans Cybern ; 48(4): 1290-1303, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28422678

RESUMO

This paper presents a novel visual tracking approach to correlation filter learning toward peak strength of correlation response. Previous methods leverage all features of the target and the immediate background to learn a correlation filter. Some features, however, may be distractive to tracking, like those from occlusion and local deformation, resulting in unstable tracking performance. This paper aims at solving this issue and proposes a novel algorithm to learn the correlation filter. The proposed approach, by imposing an elastic net constraint on the filter, can adaptively eliminate those distractive features in the correlation filtering. A new peak strength metric is proposed to measure the discriminative capability of the learned correlation filter. It is demonstrated that the proposed approach effectively strengthens the peak of the correlation response, leading to more discriminative performance than previous methods. Extensive experiments on a challenging visual tracking benchmark demonstrate that the proposed tracker outperforms most state-of-the-art methods.

20.
Journal of Chinese Physician ; (12): 75-78, 2017.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-505380

RESUMO

Objective To explore the diagnostic significance of the uric acid in preeclampsia.Methods The samples were chosen between January 2008 and August 2015 in our hospital maternity clinic,at 24 to 28 weeks of gestation,singletons,1 357 cases of pregnant women,136 cases for the development of preeclampsia,and 1 221 cases of normal pregnancy.the clinical data of 1 357 cases were retrospectively analyzed.Results (1) The maternal age,birth gestational age,body mass index,systolic blood pressure,diastolic blood pressure,urine protein,cholesterol,creatinine,uric acid,and uric acid increased value of the control group of preeclampsia were significandy higher than the normal group (P < 0.05).The incidence of preeclampsia,cesarean delivery rate,fetal growth restriction,small gestational age,and newborn asphyxia rate of high uric acid hematic disease group were significandy higher than the normal group (P < 0.05).(2) Logistic regression analysis showed that systolic blood pressure,urinary protein and uric acid were the predictors,and uric acid was the best predictor.(3) By using receiver operating characteristic (ROC) curve,the growth of uric acid was 112 μmol/L,and the sensitivity was 85.2%,the specificity was 90.1%.Conclusions Uric acid level can be used as an important indicator to monitor the pathophysiology of preeclampsia,and uric acid value can be accurately predicted.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...