1.
Phys Chem Chem Phys ; 25(10): 7170-7175, 2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36810448

RESUMO

Understanding and controlling the sintering behavior of gold nanoparticles is important for applications such as printed electronics, catalysis and sensing that utilise these materials. Here we examine the processes by which thiol-protected gold nanoparticles thermally sinter under a variety of atmospheres. We find that upon sintering, the surface-bound thiyl ligands exclusively form the corresponding disulfide species when released from the gold surface. Experiments conducted using air, hydrogen, nitrogen, or argon atmospheres revealed no significant differences between the temperatures of the sintering event nor on the composition of released organic species. When conducted under high vacuum, the sintering event occurred at lower temperatures compared to ambient pressures in cases where the resulting disulfide had relatively high volatility (dibutyl disulfide). Hexadecylthiol-stabilized particles exhibited no significant differences in the temperatures of the sintering event under ambient pressures compared to high vacuum conditions. We attribute this to the relatively low volatility of the resultant dihexadecyl disulfide product.

2.
J Appl Clin Med Phys ; 15(3): 4742, 2014 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-24892351

RESUMO

As part of the approval process for the use of scattered or uniform scanning proton therapy in National Cancer Institute (NCI)-sponsored clinical trials, the Radiological Physics Center (RPC) mandates irradiation of two RPC anthropomorphic proton phantoms (prostate and spine). The RPC evaluates these irradiations to ensure that they agree with the institutions' treatment plans within criteria of the NCI-funded cooperative study groups. The purpose of this study was to evaluate the use of an anthropomorphic spine phantom for proton matched-field irradiation, and to assess its use as a credentialing tool for proton therapy beams. We used an anthropomorphic spine phantom made of human vertebral bodies embedded in a tissue substitute material called Muscle Substitute/Solid Rigid Number 4 (MS/SR4) comprising three sections: a posterior section containing the posterior surface and the spinous processes, and left and right (L/R) sections containing the vertebral bodies and the transverse processes. After feasibility studies at three institutions, the phantom, containing two thermoluminescent dosimeters (TLDs) for absolute dose measurements and two sheets of radiochromic film for relative dosimetry, was shipped consecutively to eight proton therapy centers participating in the approval study. At each center, the phantom was placed in a supine or prone position (according to the institution's spine treatment protocol) and imaged with computed tomography (CT). The images then were used with the institution's treatment planning system (TPS) to generate two matched fields, and the phantom was irradiated accordingly. The irradiated phantom was shipped to the RPC for analysis, and the measured values were compared with the institution's TPS dose and profiles using criteria of ± 7% for dose agreement and 5 mm for profile distance to agreement. All proton centers passed the dose criterion with a mean agreement of 3% (maximum observed agreement, 7%). One center failed the profile distance-to-agreement criterion on its initial irradiation, but its second irradiation passed the criterion. Another center failed the profile distance-to-agreement criterion, but no repeat irradiation was performed. Thus, seven of the eight institutions passed the film profile distance-to-agreement criterion with a mean agreement of 1.2 mm (maximum observed agreement 5 mm). We conclude that an anthropomorphic spine phantom using TLD and radiochromic film adequately verified dose delivery and field placement for matched-field treatments.


Assuntos
Materiais Biomiméticos/normas , Ensaios Clínicos como Assunto/instrumentação , Radiometria/instrumentação , Radiometria/normas , Radioterapia de Alta Energia/instrumentação , Radioterapia de Alta Energia/normas , Coluna Vertebral/efeitos da radiação , Antropometria/instrumentação , Materiais Biomiméticos/economia , Ensaios Clínicos como Assunto/economia , Ensaios Clínicos como Assunto/normas , Aprovação de Equipamentos/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , National Cancer Institute (U.S.)/economia , National Cancer Institute (U.S.)/normas , Terapia com Prótons , Radiometria/economia , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos
3.
J Appl Clin Med Phys ; 15(2): 4523, 2014 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-24710437

RESUMO

The delivery of accurate proton dose for clinical trials requires that the appropriate conversion function from Hounsfield unit (HU) to relative linear stopping power (RLSP) be used in proton treatment planning systems (TPS). One way of verifying that the TPS is calculating the correct dose is an end-to-end test using an anthropomorphic phantom containing tissue equivalent materials and dosimeters. Many of the phantoms in use for such end-to-end tests were originally designed using tissue-equivalent materials that had physical characteristics to match patient tissues when irradiated with megavoltage photon beams. The aim of this study was to measure the RLSP of materials used in the phantoms, as well as alternative materials to enable modifying phantoms for use at proton therapy centers. Samples of materials used and projected for use in the phantoms were measured and compared to the HU assigned by the treatment planning system. A percent difference in RLSP of 5% was used as the cutoff for materials deemed acceptable for use in proton therapy (i.e., proton equivalent). Until proper tissue-substitute materials are identified and incorporated, institutions that conduct end-to-end tests with the phantoms are instructed to override the TPS with the measured stopping powers we provide. To date, the RLSPs of 18 materials have been measured using a water phantom and/or multilayer ion chamber (MLIC). Nine materials were identified as acceptable for use in anthropomorphic phantoms. Some of the failing tissue substitute materials are still used in the current phantoms. Further investigation for additional appropriate tissue substitute materials in proton beams is ongoing. Until all anthropomorphic phantoms are constructed of appropriate materials, a unique HU-RLSP phantom has been developed to be used during site visits to verify the proton facility's treatment planning HU-RLSP calibration curve.


Assuntos
Imagens de Fantasmas , Terapia com Prótons/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia/instrumentação , Antropometria , Calibragem , Humanos , Terapia com Prótons/métodos , Garantia da Qualidade dos Cuidados de Saúde , Controle de Qualidade , Radioterapia/métodos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
4.
Med Phys ; 40(9): 092102, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24007171

RESUMO

PURPOSE: The measurement of percentage depth-dose (PDD) distributions for the quality assurance of clinical proton beams is most commonly performed with a computerized water tank dosimetry system with ionization chamber, commonly referred to as water tank. Although the accuracy and reproducibility of this method is well established, it can be time-consuming if a large number of measurements are required. In this work the authors evaluate the linearity, reproducibility, sensitivity to field size, accuracy, and time-savings of another system: the Zebra, a multilayer ionization chamber system. METHODS: The Zebra, consisting of 180 parallel-plate ionization chambers with 2 mm resolution, was used to measure depth-dose distributions. The measurements were performed for scattered and scanned proton pencil beams of multiple energies delivered by the Hitachi PROBEAT synchrotron-based delivery system. For scattered beams, the Zebra-measured depth-dose distributions were compared with those measured with the water tank. The principal descriptors extracted for comparisons were: range, the depth of the distal 90% dose; spread-out Bragg peak (SOBP) length, the region between the proximal 95% and distal 90% dose; and distal-dose fall off (DDF), the region between the distal 80% and 20% dose. For scanned beams, the Zebra-measured ranges were compared with those acquired using a Bragg peak chamber during commissioning. RESULTS: The Zebra demonstrated better than 1% reproducibility and monitor unit linearity. The response of the Zebra was found to be sensitive to radiation field sizes greater than 12.5 × 12.5 cm; hence, the measurements used to determine accuracy were performed using a field size of 10 × 10 cm. For the scattered proton beams, PDD distributions showed 1.5% agreement within the SOBP, and 3.8% outside. Range values agreed within -0.1 ± 0.4 mm, with a maximum deviation of 1.2 mm. SOBP length values agreed within 0 ± 2 mm, with a maximum deviation of 6 mm. DDF values agreed within 0.3 ± 0.1 mm, with a maximum deviation of 0.6 mm. For the scanned proton pencil beams, Zebra and Bragg peak chamber range values demonstrated agreement of 0.0 ± 0.3 mm with a maximum deviation of 1.3 mm. The setup and measurement time for all Zebra measurements was 3 and 20 times less, respectively, compared to the water tank measurements. CONCLUSIONS: Our investigation shows that the Zebra can be useful not only for fast but also for accurate measurements of the depth-dose distributions of both scattered and scanned proton beams. The analysis of a large set of measurements shows that the commonly assessed beam quality parameters obtained with the Zebra are within the acceptable variations specified by the manufacturer for our delivery system.


Assuntos
Prótons , Radiometria/instrumentação , Modelos Lineares , Controle de Qualidade , Reprodutibilidade dos Testes , Espalhamento de Radiação , Fatores de Tempo
5.
Int J Radiat Oncol Biol Phys ; 78(5): 1579-85, 2010 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-20472357

RESUMO

PURPOSE: To determine planning target volume margins for prostate intensity-modulated radiotherapy based on inter- and intrafraction motion using four daily localization techniques: three-point skin mark alignment, volumetric imaging with bony landmark registration, volumetric imaging with implanted fiducial marker registration, and implanted electromagnetic transponders (beacons) detection. METHODS AND MATERIALS: Fourteen patients who underwent definitive intensity-modulated radiotherapy for prostate cancer formed the basis of this study. Each patient was implanted with three electromagnetic transponders and underwent a course of 39 treatment fractions. Daily localization was based on three-point skin mark alignment followed by transponder detection and patient repositioning. Transponder positioning was verified by volumetric imaging with cone-beam computed tomography of the pelvis. Relative motion between the prostate gland and bony anatomy was quantified by offline analyses of daily cone-beam computed tomography. Intratreatment organ motion was monitored continuously by the Calypso® System for quantification of intrafraction setup error. RESULTS: As expected, setup error (that is, inter- plus intrafraction motion, unless otherwise stated) was largest with skin mark alignment, requiring margins of 7.5 mm, 11.4 mm, and 16.3 mm, in the lateral (LR), longitudinal (SI), and vertical (AP) directions, respectively. Margin requirements accounting for intrafraction motion were smallest for transponder detection localization techniques, requiring margins of 1.4 mm (LR), 2.6 mm (SI), and 2.3 mm (AP). Bony anatomy alignment required 2.1 mm (LR), 9.4 mm (SI), and 10.5 mm (AP), whereas image-guided marker alignment required 2.8 mm (LR), 3.7 mm (SI), and 3.2 mm (AP). No marker migration was observed in the cohort. CONCLUSION: Clinically feasible, rapid, and reliable tools such as the electromagnetic transponder detection system for pretreatment target localization and, subsequently, intratreatment target location monitoring allow clinicians to reduce irradiated volumes and facilitate safe dose escalation, where appropriate.


Assuntos
Marcadores Fiduciais , Movimento , Neoplasias da Próstata , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Carga Tumoral , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Adenocarcinoma/radioterapia , Fracionamento da Dose de Radiação , Campos Eletromagnéticos , Humanos , Masculino , Posicionamento do Paciente , Pelve/diagnóstico por imagem , Imagens de Fantasmas , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Garantia da Qualidade dos Cuidados de Saúde , Radiografia , Estudos Retrospectivos
6.
Radiat Oncol ; 4: 22, 2009 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-19591687

RESUMO

PURPOSE: To assess the impact of two multileaf collimator (MLC) systems (2.5 and 5 mm leaf widths) on three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and dynamic conformal arc techniques for stereotactic body radiation therapy (SBRT) of liver and lung lesions. METHODS: Twenty-nine SBRT plans of primary liver (n=11) and lung (n=18) tumors were the basis of this study. Five-millimeter leaf width 120-leaf Varian Millennium (M120) MLC-based plans served as reference, and were designed using static conformal beams (3DCRT), sliding-window intensity-modulated beams (IMRT), or dynamic conformal arcs (DCA). Reference plans were either re-optimized or recomputed, with identical planning parameters, for a 2.5-mm width 120-leaf BrainLAB/Varian high-definition (HD120) MLC system. Dose computation was based on the anisotropic analytical algorithm (AAA, Varian Medical Systems) with tissue heterogeneity taken into account. Each plan was normalized such that 100% of the prescription dose covered 95% of the planning target volume (PTV). Isodose distributions and dose-volume histograms (DVHs) were computed and plans were evaluated with respect to target coverage criteria, normal tissue sparing criteria, as well as treatment efficiency. RESULTS: Dosimetric differences achieved using M120 and the HD120 MLC planning were generally small. Dose conformality improved in 51.7%, 62.1% and 55.2% of the IMRT, 3DCRT and DCA cases, respectively, with use of the HD120 MLC system. Dose heterogeneity increased in 75.9%, 51.7%, and 55.2% of the IMRT, 3DCRT and DCA cases, respectively, with use of the HD120 MLC system. DVH curves demonstrated a decreased volume of normal tissue irradiated to the lower (90%, 50% and 25%) isodose levels with the HD120 MLC. CONCLUSION: Data derived from the present comparative assessment suggest dosimetric merit of the high definition MLC system over the millennium MLC system. However, the clinical significance of these results warrants further investigation in order to determine whether the observed dosimetric advantages translate into outcome improvements.


Assuntos
Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirurgia , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional/métodos , Algoritmos , Desenho de Equipamento/instrumentação , Desenho de Equipamento/métodos , Humanos , Imageamento Tridimensional , Doses de Radiação , Equipamentos e Provisões para Radiação , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada