Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PeerJ ; 12: e17658, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39006011

RESUMO

Background: Vertical jumping is an important evaluation tool to measure muscle strength and power as well as lower limb symmetry. It is of practical importance and value to develop and utilize a portable and low-cost mobile application (APP) to evaluate jumping. The "My Jump 2" app is an iPhone camera-based application for measuring jumping movements, which is applied to the countermovement jump (CMJ) vertical jumps of the lower limbs of athletes in different sports. The validity of this application and previous versions applied to different forms of vertical jump tests has been preliminarily demonstrated in different population, which has an obvious progress in research. Therefore, the reliability and validity of the jump height, time of flight parameters and symmetry of the CMJ vertical jump of athletes in different sports are needed to be verified by more experiments. Purpose: The purpose of this study is to verify whether "My Jump 2" can effectively and reliably assess jump height, flight practice and lower limb symmetry in CMJAM (countermovement jump free arm) tests in fencing, swimming and diving athletes. Methods: Seventy-nine fencers, swimmers and divers with training experience participated in this study. They completed a total of three CMJAM vertical jump and lower limb symmetry tests in 1 day, while being assessed by using the "My Jump 2" application and a force platform. The intra-group correlation coefficient (ICC) was used to verify reliability, while the Cronbach's alpha and coefficient of variation (CV%) was used to analyze the stability of the CMJAM vertical jump test over three jumps. The Pearson correlation coefficient was used to verify the strength of the relationship between methods (i.e., concurrent validity), and the Bland-Altman plot was used to represent consistency, meanwhile, the t-test was used to determine the systematic bias between methods. Results: Compared with the force platform, the cumulative height values of the total number of jumps (r = 0.999; p = 0.000), the cumulative time to vacate (r = 0.999; p = 0.000) for the CMJAM test obtained by the "My Jump 2" application, the height (ICC = 0.999-1, p = 0.000), the time to vacate flight (ICC = 0.999-1, p = 0.000), contact time symmetry (ICC = 0.976-0.994, p = 0.000), and flight time symmetry (ICC = 0.921-0.982, p = 0.000), respectively. Showed high correlation between the results of "my jump 2" app and the force platform. Conclusion: The "My Jump 2" application is a valid tool to assess CMJAM vertical jump and lower limb symmetry in fencing, swimming and diving athletes with training experience.


Assuntos
Atletas , Humanos , Reprodutibilidade dos Testes , Masculino , Feminino , Adulto , Adulto Jovem , Força Muscular/fisiologia , Teste de Esforço/métodos , Teste de Esforço/instrumentação , Aplicativos Móveis , Esportes/fisiologia , Extremidade Inferior/fisiologia , Desempenho Atlético/fisiologia
2.
World J Clin Cases ; 10(31): 11549-11554, 2022 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-36387807

RESUMO

BACKGROUND: Ganglioneuromas are rare tumors of the sympathetic nervous system that originate from neural crest sympathogonia. Since the cervical spine has rarely been reported as a site for ganglioneuroma, we present a case report on this uncommon manifestation. CASE SUMMARY: A 34-year-old male presented with a 4-month history of progressive paralysis of both upper limbs along with an unsteady gait. The touch sensitivity of both hands was reduced, and there was conspicuously high muscle tonus in his upper and lower limbs, along with hyperactive physiological reflection and deep reflexes. Magnetic resonance imaging showed several nodules around the C2-7 intervertebral foramena, among which the masses lying between C1 and C2 were obviously bilaterally compressing the spinal cord. Successful posterior decompression was performed without fixation and the tumors in the upper cervical spine were removed intact, with rapid relief of symptoms. The pathological diagnosis was ganglioneuroma. CONCLUSION: Multiple and bilateral ganglioneuroams are a rare occurrence in the cervical spine. In this case report, timely resection of the neoplasms around C1 and C2 resulted in spinal cord decompression, with rapid relief of symptoms and a good prognosis. Including the current case, we are aware of only seven such cases in the literature, of which four arose from Japan, one from China, and one from Spain. We suppose that ethnicity and geographic associations with this rare disease presentation may be an aspect for future consideration and investigation.

3.
Medicine (Baltimore) ; 101(31): e30023, 2022 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-35945791

RESUMO

This study aimed to analyze the most influential publications on vertebral augmentation for treating osteoporotic vertebral compression fracture. The Web of Science database was searched using the key words "percutaneous vertebroplasty," "percutaneous kyphoplasty," "balloon kyphoplasty," "vertebroplasty," "kyphoplasty," and "vertebral augmentation." The top 100 publications were arranged by citations per year and descriptively and visually analyzed. The top 100 publications were cited 25,482 times, with an average of 14.4 citations per paper per year. The corresponding authors of the publications represented 17 nations, with most authors being American (46 authors). Thirty-two journals were involved, with SPINE issuing the most publications (24 papers of the 100). Clinical research (73 of the 100 papers) outnumbered basic studies (14 papers) and systematic reviews (13 papers), and the most publications were published between 2000 and 2004. Co-citation analysis of the key words indicated that the top 5 focus areas were "complication," "balloon kyphoplasty," "vertebral compression fracture," "biomechanics," and "calcium phosphate cement." The top 3 keywords with the strongest citation bursts were "compression fracture," "cement," and "balloon kyphoplasty." The keywords with persistent strong citation bursts are "balloon kyphoplasty" and "augmentation." There are still contrary opinions about vertebral augmentation; new research should be conducted with more deliberate design and longer follow-up.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Vertebroplastia , Cimentos Ósseos/uso terapêutico , Fraturas por Compressão/complicações , Humanos , Cifoplastia/efeitos adversos , Fraturas por Osteoporose/complicações , Fraturas da Coluna Vertebral/etiologia , Resultado do Tratamento , Vertebroplastia/efeitos adversos
4.
Orthop Surg ; 13(5): 1556-1562, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34105261

RESUMO

OBJECTIVE: To analyze the anatomical variations of V3 and V2 segments of the vertebral artery in the Chinese population. METHODS: The current retrospective study was an observational, anatomical, radiological research. Between 1 January 2018 to 31 December 2019, the data of 589 continuous head-and-neck three-dimensional computed tomography angiography were observed and analyzed using the open-source software of Horos. There were 415 males and 174 females with an average age of 44.63 ± 2.5(18-74) years. The variations of the V3 segment were defined as persistent first intersegmental artery (PFIA) and paracondylar processes (PP). The variations of V2 segments were unusual vertebral artery entrance transverse foreman (UE-V2S) and midline migration (MM). The incidences of all variations were summarized and the gender, side characters were compared. RESULTS: Among the patients, 4.34% (18/415) males and 4.60% (8/174) females were with the variation of PFIA. Meanwhile, 12.29% (51/415) males and 10.92% (19/174) females were with the variation of PP. Then 18.80% (78/415) males and 16.67% (29/174) females were with UE-V2S. All the variations above were not different in genders. As for the variation of MM, 3.86% (16/415) males and 8.62% (15/174) females were identified, and the difference of genders was significant for this type of variation (P < 0.05). The differences between each side were also observed and analyzed for all variations and no differences were found. CONCLUSION: There are several variations of V3 and V2 segments of the vertebral artery are associated with the cervical surgeries, most were without differences in genders and sides, except the variation of MM.


Assuntos
Variação Anatômica , Artéria Vertebral/anatomia & histologia , Artéria Vertebral/diagnóstico por imagem , Adolescente , Adulto , Idoso , China , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
5.
Entropy (Basel) ; 20(6)2018 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-33265518

RESUMO

According to the fact that high frequency will be abnormally attenuated when seismic signals travel across reservoirs, a new method, which is named high-precision time-frequency entropy based on synchrosqueezing generalized S-transform, is proposed for hydrocarbon reservoir detection in this paper. First, the proposed method obtains the time-frequency spectra by synchrosqueezing generalized S-transform (SSGST), which are concentrated around the real instantaneous frequency of the signals. Then, considering the characteristics and effects of noises, we give a frequency constraint condition to calculate the entropy based on time-frequency spectra. The synthetic example verifies that the entropy will be abnormally high when seismic signals have an abnormal attenuation. Besides, comparing with the GST time-frequency entropy and the original SSGST time-frequency entropy in field data, the results of the proposed method show higher precision. Moreover, the proposed method can not only accurately detect and locate hydrocarbon reservoirs, but also effectively suppress the impact of random noises.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...