Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1312: 342780, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38834272

RESUMO

BACKGROUND: The convenient preparation and application of functionalized organic-inorganic hybrid monolithic materials have obtained substantial interest in the pretreatment of complex samples by solid-phase extraction (SPE). Compared to the in-tube solid-phase microextraction in fused-silica capillaries, micro SPE in plastic pipette tips have fascinating merits for the easily operated enrichment of trace target analytes from biological samples. However, the poor compatibility of organic-inorganic hybrid monoliths with plastics leads to the rare appearance of commercial hybrid monolithic pipette tips (HMPTs). Therefore, how to synthesize the organic-inorganic hybrid monolithic materials with better extraction performance in plastic pipette tips becomes a challenge. RESULTS: We develop a facile and cheap strategy to immobilize organic-inorganic hybrid monoliths in pipette tips. Melamine sponge was employed as the supporting skeleton to in situ assemble amine- and thiol-bifunctionalized hybrid monolithic material via "one pot" in a pipette tip, and gold nanoparticles (GNPs) and thiol-modified aptamer against human α-thrombin were sequentially attached to the hybrid monolith within the HMPTs. The average coverage density of the aptamer with GNPs as an intermediary reached as high as 818.5 pmol µL-1. The enriched thrombin concentration was determined by a sensitive enzymatic chromogenic assay with the limit of detection of 2 nM. The extraction recovery of thrombin at 10 nM in human serum was 86.1 % with a relative standard deviation of 6.1 %. This proposed protocol has been applied to the enrichment and determination of thrombin in real serum sample with strong anti-interference ability, low limit of detection and high recovery. SIGNIFICANCE: The amine- and thiol-bifunctionalized HMPTs prepared with sponge as the skeleton frame provided a novel substrate material to decorate aptamers for efficient enrichment of proteins. This enlightens us that we can take advantage of the tunability of sponge assisted HMPTs to produce and tailor a variety of micro SPE pipette tips for broader applications on the analysis of trace targets in complex biological, clinic and environmental samples.


Assuntos
Aptâmeros de Nucleotídeos , Trombina , Triazinas , Triazinas/química , Triazinas/isolamento & purificação , Aptâmeros de Nucleotídeos/química , Humanos , Trombina/análise , Trombina/isolamento & purificação , Ouro/química , Nanopartículas Metálicas/química , Extração em Fase Sólida/métodos
2.
Anal Chim Acta ; 1162: 338477, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33926696

RESUMO

In this work, a novel amino functionalized Cu(II) ion-imprinted organic-inorganic hybrid monolithic column (Cu(II)-IIHMC) was prepared via one-pot co-condensation and the combination of sol-gel and ion-imprinting techniques in a fused capillary. The Cu(II)-IIHMC was used as solid phase microextraction (SPME) matrix followed by inductively coupled plasma-mass spectrometry (ICP-MS) for the analysis of trace Cu(II). The prepared Cu(II)-IIHMC has good mechanical strength, stable imprinting sites and homogeneous structure of network skeleton with large flow-through pores by optimizing the synthesis process. Under the optimized conditions, the Cu(II)-IIHMC can selectively adsorb Cu(II) with the adsorption capacity of 3.13 mg g-1. With enrichment factor of 10-fold, the calibration curve was established in the range of 0.05-50 µg L-1 with r2 of 0.9992 and the detection limit was 0.008 µg L-1 for Cu(II). Compared with the non-imprinted hybrid monolithic column (Cu(II)-NIHMC), the Cu(II)-IIHMC possesses better selectivity, anti-interference ability and adsorption capacity. The Cu(II)-IIHMC can specifically capture the target ion in the presence of competitive ions, with the selectivity coefficients exceeding 39.4. The protocol was validated by analyzing Certified Reference Materials of standard sediment, soil and iron ore, and the results were in good agreement with certified values. Moreover, the proposed in-tube SPME procedure can not only preconcentrate trace Cu(II), but also effectively reduce the matrix effect and powerfully eliminate the interference from the main metals in real samples. Therefore, the developed SPME-ICP-MS method with facile preparation, specific selectivity, high sensitivity and efficient analysis, was applied in the determination of trace Cu(II) in environmental and mineral samples with the recoveries of 89.8-111.8% in all spiked samples.

3.
Talanta ; 225: 121993, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33592740

RESUMO

Organic-inorganic hybrid monolithic columns, due to the comprehensive advantages, have been applied as promising solid-phase separation matrices for pretreatment of complex samples in biomedical and environmental analyses, however, a tremendous time and efforts are cost to optimize the preparation methods of hybrid monolithic columns with different functional groups for various target analytes. Herein, we proposed a strategy to develop basic hybrid monolithic column materials for flexible and facile post-functionalization. Three kinds of single-functionalized (amine, thiol, and carboxyl) and two kinds of bi-functionalized (amine and thiol, and amine and carboxyl) hybrid monolithic columns were immobilized with gold nanoparticles (GNPs) as intermediary bridge to construct the universal substrates. The GNPs adsorption capacities of the five hybrid monoliths were compared through qualitative characterization and quantitative analysis. Thioglycolic acid (TGA) and an aptamer against human α-thrombin were respectively used for further functionalizing the substrates to select the most suitable hybrid monolith for optional post-functionalization. It was reported for the first time that the coverage density of TGA on functionalized monolithic column modified by GNPs was 168.41 nmol µL-1. Notably, the coverage density (2205.8 pmol µL-1) of the aptamer decorated on the hybrid monolithic column was significantly higher than most other similar materials in published works. After that, the aptamer functionalized hybrid monolithic column screened out was applied for the solid-phase microextraction of thrombin, which possessed excellent adsorption selectivity in interference experiment. Consequently, the developed GNPs modified amine- and thiol-bi-functionalized hybrid monolithic column is an attractive universal substrate to realize easy and efficient post-modification of separation materials for other target analytes in complex samples avoiding a lot of time and labor consumption in the optimization of process preparation.


Assuntos
Ouro , Nanopartículas Metálicas , Humanos , Microextração em Fase Sólida , Compostos de Sulfidrila , Trombina
4.
Anal Chim Acta ; 1137: 85-93, 2020 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-33153612

RESUMO

A novel carboxyl-functionalized hybrid monolithic column was developed based on "thiol-ene" click reaction via "one-pot" by choosing mercaptosuccinic acid, γ-methyl methacrylate trimethoxysilane and tetramethoxysilane as reaction monomers. The design of the hybrid monolithic column was assisted by the comparison in computational simulation with existing carboxyl-functionalized materials. The characterization by scanning electron microscopy, energy dispersive X-ray spectroscopy, N2 adsorption-desorption measurement, Fourier-transform infrared spectroscopy and elemental analysis showed that the carboxyl-functionalized material has the advantages of good permeability and high mechanical strength. Then, we used the prepared carboxyl-hybrid monolith column as solid phase microextraction adsorbent for separation of trace inorganic chromium species. Under pH 4.5, the hybrid monolith column can selectively enrich Cr(III) without adsorbing Cr(VI) and afterwards, Cr(III) can be eluted by 1.0 mol L-1 HCl. The chromium speciation separation method based on carboxyl-hybrid monolith column followed by inductively coupled plasma-mass spectrometry possessed the merits of facile preparation, low cost, simple and mild extraction condition, and sensitive detection, which has been successfully applied to the separation, enrichment and detection of inorganic chromium in environmental waters.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...