Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Angew Chem Int Ed Engl ; 60(35): 19144-19154, 2021 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-34062043

RESUMO

We investigated the material properties of Cremonese soundboards using a wide range of spectroscopic, microscopic, and chemical techniques. We found similar types of spruce in Cremonese soundboards as in modern instruments, but Cremonese spruces exhibit unnatural elemental compositions and oxidation patterns that suggest artificial manipulation. Combining analytical data and historical information, we may deduce the minerals being added and their potential functions-borax and metal sulfates for fungal suppression, table salt for moisture control, alum for molecular crosslinking, and potash or quicklime for alkaline treatment. The overall purpose may have been wood preservation or acoustic tuning. Hemicellulose fragmentation and altered cellulose nanostructures are observed in heavily treated Stradivari specimens, which show diminished second-harmonic generation signals. Guarneri's practice of crosslinking wood fibers via aluminum coordination may also affect mechanical and acoustic properties. Our data suggest that old masters undertook materials engineering experiments to produce soundboards with unique properties.

2.
Anal Chem ; 92(20): 13997-14005, 2020 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-32856458

RESUMO

Recent research has revealed the use of graphene oxide (GO) and its derivatives as a potential biomaterial because of their attractive physicochemical characteristics and functional properties. However, if GO and related derivatives are to become useful materials for biomedical applications, it will be necessary to evaluate their biodistribution for health and safety considerations. To obtain a more accurate biodistribution for GO, we (i) developed a postadministration labeling strategy employing DNA-conjugated gold nanoparticles (DNA-AuNPs) to selectively label administered GO in Solvable-treated tissue samples and (ii) constructed an automatic sample pretreatment scheme (using a C18-packed minicolumn) to effectively separate the DNA-AuNP-labeled GO from the unbound DNA-AuNPs and the dissolved tissue matrices, thereby enabling ultrasensitive, interference-free quantification of GO through measurement (inductively coupled plasma mass spectrometry) of the Au signal intensities. The DNA-AuNPs can bind to GO in a concentration- and time-dependent manner. After optimizing the labeling conditions (DNA length, incubation pH, DNA-AuNP concentration, and incubation time) and the separation scheme (sample loading flow rate, rinsing volume, and eluent composition), we found that A20R20-AuNPs (R20: random DNA sequence including A, T, C, and G) had the strongest binding affinity for labeling of the administered GO (dissociation constant: 36.0 fM) and that the method's detection limit reached 9.3 ag L-1 with a calibration curve having a working range from 10-1 to 1010 fg L-1. Moreover, this approach revealed that the intravenously administered GO accumulated predominantly in the liver and spleen at 1 and 12 h post administration, with apparent discrepancies in the concentrations measured using pre- and postadministration labeling strategies.


Assuntos
DNA/química , Ouro/química , Grafite/análise , Espectrometria de Massas/métodos , Nanopartículas Metálicas/química , Animais , Grafite/administração & dosagem , Grafite/farmacocinética , Limite de Detecção , Masculino , Gases em Plasma/química , Ratos , Ratos Sprague-Dawley , Distribuição Tecidual
3.
Biomater Sci ; 8(7): 1934-1950, 2020 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-32039412

RESUMO

An aptamer-conjugated gold nanostar (dsDDA-AuNS) has been developed for targeting nucleolin present in both tumor cells and tumor vasculature for conducting a drug-resistant cancer therapy. AuNS with its strong absorption in the near-infrared (NIR) region was assembled with a layer of the anti-nucleolin aptamer AS1411. An anticancer drug, namely doxorubicin (DOX), was specifically conjugated on deoxyguanosine residues employing heat and acid labile methylene linkages. In response to NIR irradiation, dsDDA-AuNS allowed on-demand therapeutics. AS1411 played an active role in drug cargo-nucleus interactions, enhancing drug accumulation in the nuclei of drug-resistant breast cancer cells. The intravenous injection of dsDDA-AuNS allowed higher drug accumulation in drug-resistant tumors over naked drugs, leading to greater therapeutic efficacy even at a 54-fold less equivalent drug dose. The in vivo triggered release of DOX from dsDDA-AuNS was achieved by NIR irradiation, resulting in simultaneous photothermal and chemotherapeutic actions, yielding superior tumor growth inhibition than those obtained from either type of monotherapy for overcoming drug resistance in cancers.


Assuntos
Antineoplásicos/administração & dosagem , Aptâmeros de Nucleotídeos/administração & dosagem , Neoplasias da Mama/tratamento farmacológico , Doxorrubicina/administração & dosagem , Resistencia a Medicamentos Antineoplásicos/efeitos dos fármacos , Ouro/química , Oligodesoxirribonucleotídeos/administração & dosagem , Administração Intravenosa , Animais , Antineoplásicos/química , Antineoplásicos/farmacologia , Aptâmeros de Nucleotídeos/química , Aptâmeros de Nucleotídeos/farmacologia , Neoplasias da Mama/genética , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Doxorrubicina/química , Doxorrubicina/farmacologia , Feminino , Humanos , Células MCF-7 , Nanopartículas Metálicas , Camundongos , Oligodesoxirribonucleotídeos/química , Oligodesoxirribonucleotídeos/farmacologia , Fosfoproteínas/efeitos dos fármacos , Fosfoproteínas/genética , Proteínas de Ligação a RNA/efeitos dos fármacos , Proteínas de Ligação a RNA/genética , Ensaios Antitumorais Modelo de Xenoenxerto , Nucleolina
4.
Anal Chim Acta ; 1063: 82-90, 2019 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-30967189

RESUMO

In this study, a novel automatic analytical methodology using a titanium dioxide (TiO2)-assisted preconcentration/on-site vapor-generation (VG) chip hyphenated with inductively coupled plasma-mass spectrometry (ICP-MS) for online determination of mercuric ions (Hg2+) was developed. Interestingly, the TiO2 nanoparticle (nano-TiO2) coating on the channel surface acted not only as a sorbent for preconcentration but also as a catalyst for photocatalyst-assisted VG. Under optimum operation conditions, the developed method was validated by analyzing the certified reference material (CRM) Seronorm™ Trace Elements Urine L-2 (freeze-dried human urine). Based on the obtained results, the dramatic reduction of "hands-on" manipulation and the elimination of hazardous materials (e.g., sodium borohydride (NaBH4) and stannous chloride (SnCl2)) from the process enabled a simple and ultraclean procedure with an extremely low detection limit of 0.75 ng L-1 for Hg2+ in urine samples. To the best of our knowledge, this is the first study to report the direct exploitation of a nano-TiO2-coated microfluidic device for online sample preconcentration and on-site VG prior to ICP-MS measurement.


Assuntos
Mercúrio/urina , Titânio/química , Humanos , Íons/urina , Espectrometria de Massas/instrumentação , Volatilização
5.
Theranostics ; 7(12): 3034-3052, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28839462

RESUMO

Recently, living cells with tumor-homing properties have provided an exciting opportunity to achieve optimal delivery of nanotherapeutic agents. However, premature payload leakage may impair the host cells, often leading to inadequate in vivo investigations or therapeutic efficacy. Therefore, a nanoplatform that provides a high drug-loading capacity and the precise control of drug release is required. In the present study, a robust one-step synthesis of a doxorubicin (DOX)-loaded gold nanorod/albumin core-shell nanoplatform (NR@DOX:SA) was designed for effective macrophage-mediated delivery to demonstrate how nanoparticle-loaded macrophages improve photothermal/chemodrug distribution and retention ability to achieve enhanced antitumor effects. The serum albumin shell of these nanoagents served as a drug reservoir to delay the intracellular DOX release and drug-related toxicity that impairs the host cell carriers. Near-infrared laser irradiation enabled on-demand payload release to destroy neighboring tumor cells. A series of in vivo quantitative analyses demonstrated that the nanoengineered macrophages delivered the nanodrugs through tumor-tropic migration to tumor tissues, resulting in the twice homogenous and efficient photothermal activations of drug release to treat prostate cancer. By contrast, localized pristine NR@DOX:SAs exhibit limited photothermal drug delivery that further reduces their retention ability and therapeutic efficacy after second combinational treatment, leading to a failure of cancer therapy. Moreover, the resultant unhealable wounds impair quality of life. Free DOX has rapid clearance and therefore exhibits limited antitumor effects. Our findings suggest that in comparison with pristine nanoparticles or free DOX, the nanoengineered macrophages effectively demonstrate the importance and effect of homogeneous drug distribution and retention ability in cancer therapy.


Assuntos
Albuminas/metabolismo , Antineoplásicos/farmacocinética , Doxorrubicina/farmacocinética , Portadores de Fármacos/metabolismo , Ouro/metabolismo , Macrófagos/metabolismo , Nanotubos , Animais , Modelos Animais de Doenças , Tratamento Farmacológico/métodos , Hipertermia Induzida/métodos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Neoplasias da Próstata/terapia , Células RAW 264.7
6.
J Sep Sci ; 40(19): 3866-3872, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28748649

RESUMO

A vortex-assisted liquid-liquid microextraction method was developed for the chromatographic determination of strontium in aqueous samples. In the method, strontium was complexed with 4',4″(5″)-di-(tert-butylcyclohexano)-18-crown-6 in the presence of tetraphenylborate as the counter anion, which increased the hydrophobicity of the ion-association complex, resulting in its improved extraction into 1-octanol. Strontium from the organic phase was stripped with nitric acid back to aqueous solution and determined by ion chromatography. The optimum microextraction conditions were as follows: 2.0 mL aqueous samples with 3 mM tetraphenylborate; 150 µL of 1-octanol as the extractant phase with 10 mM DtBuCH18C6; vortex extraction time for 10 s; centrifugation at 6000 rpm for 4 min; stripping by 0.1 M nitric acid. Under the optimum conditions, the detection limit for strontium was 0.005 mg/L. The calibration curves showed good linearity over the range between 0.01 and 2.5 mg/L. Intra- and interday precisions of the present method were satisfactory with relative standard deviations of 1.7 and 2.1%, respectively.

7.
Anal Chem ; 89(11): 5891-5899, 2017 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-28459544

RESUMO

To selectively and sensitively determine the trace inorganic As species, As(III) and As(V), we developed a nanocomposite-coated microfluidic-based photocatalyst-assisted reduction device (PCARD) as a vapor generation (VG) device to couple high-performance liquid chromatography (HPLC) separation and inductively coupled plasma-mass spectrometry (ICPMS) detection. Au nanoparticles were deposited on TiO2 nanoparticles to strengthen the conversion efficiency of the nanocomposite photocatalytic reduction. The sensitivity for As was significantly enhanced by employing the nanocomposite photocatalyst and using prereduction and signal-enhancement reagents. Under the optimal operating conditions, the analytical detection limits (based on 3σ) of the proposed online HPLC/nanocomposite-coated microfluidic-based PCARD/ICPMS system for As(III) and As(V) were 0.23 and 0.34 µg·L-1, respectively. The results were validated using a certified reference material (NIST SRM 1643e) and groundwater sample analysis, indicating the good reliability and applicability of our proposed system for the determination of inorganic As species in natural fresh water.

8.
Anal Chim Acta ; 956: 24-31, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28093122

RESUMO

Probing tumor extracellular metabolites is a vitally important issue in current cancer biology. In this study an analytical system was constructed for the in vivo monitoring of mouse tumor extracellular hydrogen peroxide (H2O2), lactate, and glucose by means of microdialysis (MD) sampling and fluorescence determination in conjunction with a smart sequential enzymatic derivatization scheme-involving a loading sequence of fluorogenic reagent/horseradish peroxidase, microdialysate, lactate oxidase, pyruvate, and glucose oxidase-for step-by-step determination of sampled H2O2, lactate, and glucose in mouse tumor microdialysate. After optimization of the overall experimental parameters, the system's detection limit reached as low as 0.002 mM for H2O2, 0.058 mM for lactate, and 0.055 mM for glucose, based on 3 µL of microdialysate, suggesting great potential for determining tumor extracellular concentrations of lactate and glucose. Spike analyses of offline-collected mouse tumor microdialysate and monitoring of the basal concentrations of mouse tumor extracellular H2O2, lactate, and glucose, as well as those after imparting metabolic disturbance through intra-tumor administration of a glucose solution through a prior-implanted cannula, were conducted to demonstrate the system's applicability. Our results evidently indicate that hyphenation of an MD sampling device with an optimized sequential enzymatic derivatization scheme and a fluorescence spectrometer can be used successfully for multi-analyte monitoring of tumor extracellular metabolites in living animals.


Assuntos
Glucose/análise , Peróxido de Hidrogênio/análise , Ácido Láctico/análise , Microdiálise , Neoplasias/química , Animais , Camundongos
9.
Anal Chim Acta ; 953: 87-94, 2017 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-28010747

RESUMO

Exploration of brain extracellular non-protein-bound/diffusible iron species remains a critically important issue in investigations of free radical biology and neurodegenerative diseases. In this study, a facile sample pretreatment scheme, involving poly(vinyl chloride)-metal ion interactions as a selective extraction procedure, was optimized in conjunction with microdialysis (MD) sampling and inductively coupled plasma mass spectrometry (ICP-MS) in cool-plasma mode for in vivo online monitoring of rat brain extracellular Fe(II) and Fe(III) species. Optimization of the system provided detection limits in the range 0.9-6.9 µg Fe L-1, based on a 12-µL microdialysate, for the tested iron species; relative standard deviations of the signal intensities during 7.8 h of continuous measurement were less than 9.4%-sufficient to determine the basal concentrations of rat brain extracellular Fe(II) and Fe(III) species and to describe their dynamic actions. The method's applicability was verified through (i) spike analyses of offline-collected rat brain microdialysates, (ii) determination of the basal Fe(II) and Fe(III) concentrations of living rat brain extracellular fluids, and (iii) monitoring of the dynamic changes in the Fe(II) and Fe(III) concentrations in response to perfusion of a high-K+ medium. This proposed sample pretreatment scheme, based on polymer-metal ion interactions and hyphenation to an MD sampling device and an ICP-MS system, appears to have great practicality for the online monitoring of rat brain extracellular diffusible iron species.


Assuntos
Encéfalo , Líquido Extracelular/química , Compostos Férricos/análise , Compostos Ferrosos/análise , Extração em Fase Sólida , Animais , Ferro , Ratos
10.
J Vis Exp ; (114)2016 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-27584954

RESUMO

This paper describes a fabrication protocol for a dipole-assisted solid phase extraction (SPE) microchip available for trace metal analysis in water samples. A brief overview of the evolution of chip-based SPE techniques is provided. This is followed by an introduction to specific polymeric materials and their role in SPE. To develop an innovative dipole-assisted SPE technique, a chlorine (Cl)-containing SPE functionality was implanted into a poly(methyl methacrylate) (PMMA) microchip. Herein, diverse analytical techniques including contact angle analysis, Raman spectroscopic analysis, and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) analysis were employed to validate the utility of the implantation protocol of the C-Cl moieties on the PMMA. The analytical results of the X-ray absorption near-edge structure (XANES) analysis also demonstrated the feasibility of the Cl-containing PMMA used as an extraction medium by virtue of the dipole-ion interactions between the highly electronegative C-Cl moieties and the positively charged metal ions.


Assuntos
Espectrometria de Massas/métodos , Metais/análise , Polímeros/análise , Extração em Fase Sólida/métodos , Oligoelementos/análise
11.
Anal Chem ; 88(12): 6265-73, 2016 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-27232384

RESUMO

In this study we constructed a highly sensitive system for in vivo monitoring of the concentrations of rat brain extracellular glucose and lactate. This system involved microdialysis (MD) sampling and fluorescence determination in conjunction with a novel sample derivatization scheme in which glucose oxidase and lactate oxidase were immobilized in ABS flow bioreactors (manufactured through low-cost three-dimensional printing (3DP)), via fused deposition modeling, for online oxidization of sampled glucose and lactate, respectively, in rat brain microdialysate. After optimizing the experimental conditions for MD sampling, the manufacture of the designed flow reactors, the enzyme immobilization procedure, and the online derivatization scheme, the available sampling frequency was 15 h(-1) and the system's detection limits reached as low as 0.060 mM for glucose and 0.059 mM for lactate, based on a 20-µL conditioned microdialysate; these characteristics were sufficient to reliably determine the concentrations of extracellular glucose and lactate in the brains of living rats. To demonstrate the system's applicability, we performed (i) spike analyses of offline-collected rat brain microdialysate and (ii) in vivo dynamic monitoring of the extracellular glucose and lactate in living rat brains, in addition to triggering neuronal depolarization by perfusing a high-K(+) medium from the implanted MD probe. Our analytical results and demonstrations confirm that postprinting functionalization of analytical devices manufactured using 3DP technology can be a powerful strategy for extending the diversity and adaptability of currently existing analytical configurations.


Assuntos
Encéfalo/metabolismo , Glucose Oxidase/metabolismo , Glucose/análise , Ácido Láctico/análise , Oxigenases de Função Mista/metabolismo , Impressão Tridimensional , Espectrometria de Fluorescência , Animais , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Glucose Oxidase/química , Limite de Detecção , Masculino , Microdiálise , Oxigenases de Função Mista/química , Ratos , Ratos Sprague-Dawley
12.
Anal Chim Acta ; 914: 110-6, 2016 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-26965333

RESUMO

Whether silver nanoparticles (AgNPs) persist or release silver ions (Ag(+)) when discharged into a natural environment has remained an unresolved issue. In this study, we employed a low-cost stereolithographic three-dimensional printing (3DP) technology to fabricate the angle-defined knotted reactors (KRs) to construct a simple differentiation scheme for quantitative assessment of Ag(+) ions and AgNPs in municipal wastewater samples. We chose xanthan/phosphate-buffered saline as a dispersion medium for in situ stabilization of the two silver species, while also facilitating their extraction from complicated wastewater matrices. After method optimization, we measured extraction efficiencies of 54.5 and 32.3% for retaining Ag(+) ions and AgNPs, respectively, in the printed KR (768-turn), with detection limits (DLs) of 0.86 and 0.52 ng L(-1) when determining Ag(+) ions and AgNPs, respectively (sample run at pH 11 without a rinse solution), and 0.86 ng L(-1) when determining Ag(+) ions alone (sample run at pH 12 with a 1.5-mL rinse solution). The proposed scheme is tolerant of the wastewater matrix and provides more reliable differentiation between Ag(+)/AgNPs than does a conventional filtration method. The concept and applicability of adopting 3DP technology to renew traditional KR devices were evidently proven by means of these significantly improved analytical performance. Our analytical data suggested that the concentrations of Ag(+) ions and AgNPs in the tested industrial wastewater sample were both higher than those in domestic wastewater, implying that industrial activity might be a main source of environmental silver species, rather than domestic discharge from AgNP-containing products.


Assuntos
Nanopartículas Metálicas/química , Prata/química , Águas Residuárias/química , Poluentes da Água/análise
13.
Anal Chim Acta ; 916: 24-32, 2016 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-27016435

RESUMO

Herein, a hyphenated system combining a high-throughput solid-phase extraction (htSPE) microchip with inductively coupled plasma-mass spectrometry (ICP-MS) for rapid determination of trace heavy metals was developed. Rather than performing multiple analyses in parallel for the enhancement of analytical throughput, we improved the processing speed for individual samples by increasing the operation flow rate during SPE procedures. To this end, an innovative device combining a micromixer and a multi-channeled extraction unit was designed. Furthermore, a programmable valve manifold was used to interface the developed microchip and ICP-MS instrumentation in order to fully automate the system, leading to a dramatic reduction in operation time and human error. Under the optimized operation conditions for the established system, detection limits of 1.64-42.54 ng L(-1) for the analyte ions were achieved. Validation procedures demonstrated that the developed method could be satisfactorily applied to the determination of trace heavy metals in natural water. Each analysis could be readily accomplished within just 186 s using the established system. This represents, to the best of our knowledge, an unprecedented speed for the analysis of trace heavy metal ions.

14.
Anal Chem ; 87(13): 6945-50, 2015 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-26101898

RESUMO

In this study, we used a stereolithographic 3D printing technique and polyacrylate polymers to manufacture a solid phase extraction preconcentrator for the selective extraction of trace elements and the removal of unwanted salt matrices, enabling accurate and rapid analyses of trace elements in seawater samples when combined with a quadrupole-based inductively coupled plasma mass spectrometer. To maximize the extraction efficiency, we evaluated the effect of filling the extraction channel with ordered cuboids to improve liquid mixing. Upon automation of the system and optimization of the method, the device allowed highly sensitive and interference-free determination of Mn, Ni, Zn, Cu, Cd, and Pb, with detection limits comparable with those of most conventional methods. The system's analytical reliability was further confirmed through analyses of reference materials and spike analyses of real seawater samples. This study suggests that 3D printing can be a powerful tool for building multilayer fluidic manipulation devices, simplifying the construction of complex experimental components, and facilitating the operation of sophisticated analytical procedures for most sample pretreatment applications.


Assuntos
Impressão Tridimensional , Água do Mar/química , Oligoelementos/análise , Extração em Fase Sólida
15.
J Chromatogr A ; 1402: 1-7, 2015 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-26004654

RESUMO

The extravasation of administered nano-drug carriers is a critical process for determining their distributions in target and non-target organs, as well as their pharmaceutical efficacies and side effects. To evaluate the extravasation behavior of gold nanoparticles (AuNPs), currently the most popular drug delivery system, in a mouse tumor model, in this study we employed push-pull perfusion (PPP) as a means of continuously sampling tumor extracellular AuNPs. To facilitate quantification of the extravasated AuNPs through inductively coupled plasma mass spectrometry, we also developed a novel online open-tubular fractionation scheme to allow interference-free determination of the sampled extracellular AuNPs from the coexisting biological matrix. After optimizing the flow-through volume and flow rate of this proposed fractionation scheme, we found that (i) the system's temporal resolution was 7.5h(-1), (ii) the stability presented by the coefficient of variation was less than 10% (6-h continuous measurement), and (iii) the detection limits for the administered AuNPs were in the range 0.057-0.068µgL(-1). Following an intravenous dosage of AuNPs (0.3mgkg(-1) body weight), in vivo acquired profiles indicated that the pegylated AuNPs (PEG-AuNPs) had greater tendency toward extravasating into the tumor extracellular space. We also observed that the accumulation of nanoparticles in the whole tumor tissues was higher for PEG-AuNPs than for non-pegylated ones. Overall, pegylation appears to promote the extravasation and accumulation of AuNPs for nano-drug delivery applications.


Assuntos
Ouro/análise , Nanopartículas/análise , Neoplasias/química , Animais , Fracionamento Químico , Modelos Animais de Doenças , Portadores de Fármacos , Sistemas de Liberação de Medicamentos/normas , Espaço Extracelular/química , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Neoplasias/metabolismo
16.
Analyst ; 140(2): 600-8, 2015 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25426495

RESUMO

We employed a polymeric material, poly(methyl methacrylate) (PMMA), for fabricating a microdevice and then implanted the chlorine (Cl)-containing solid-phase extraction (SPE) functionality into the PMMA chip to develop an innovative on-chip dipole-assisted SPE technique. Instead of the ion-ion interactions utilized in on-chip SPE techniques, the dipole-ion interactions between the highly electronegative C-Cl moieties in the channel interior and the positively charged metal ions were employed to facilitate the on-chip SPE procedures. Furthermore, to avoid labor-intensive manual manipulation, a programmable valve manifold was designed as an interface combining the dipole-assisted SPE microchip and inductively coupled plasma-mass spectrometry (ICP-MS) to achieve the fully automated operation. Under the optimized operation conditions for the established system, the detection limits for each analyte ion were obtained based on three times the standard deviation of seven measurements of the blank eluent solution. The limits ranged from 3.48 to 20.68 ng L(-1), suggesting that this technique appears uniquely suited for determining the levels of heavy metal ions in natural water. Indeed, a series of validation procedures demonstrated that the developed method could be satisfactorily applied to the determination of trace heavy metals in natural water. Remarkably, the developed device was durable enough to be reused more than 160 times without any loss in its analytical performance. To the best of our knowledge, this is the first study reporting on the combination of a dipole-assisted SPE microchip and elemental analysis instrument for the online determination of trace heavy metal ions.


Assuntos
Metais Pesados/análise , Procedimentos Analíticos em Microchip/métodos , Poluentes Químicos da Água/análise , Água/análise , Dispositivos Lab-On-A-Chip , Limite de Detecção , Espectrometria de Massas/métodos , Polimetil Metacrilato , Extração em Fase Sólida/métodos , Poluição Química da Água/análise
17.
Biosens Bioelectron ; 64: 535-41, 2015 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-25310485

RESUMO

In this study we developed a facile and sensitive method for continuous monitoring of extracellular glucose concentration in living rat brain through microdialysis (MD) sampling in conjunction with (i) online sample derivatization using glucose oxidase to generate H2O2, which converted a reactive oxygen species-responsive fluorescent dye, 2',7'-dichlorodihydrofluorescein (DCFH), into fluorescent species, and (ii) a novel non-immobilized enzyme-based fluorescence assay strategy, featuring copper ion (Cu(2+))-facilitated amplification of the fluorescence intensity. After evaluating the experimental conditions for glucose oxidation and fluorescence generation, the introduction of Cu(2+) ions to this system resulted in an additional 51-fold amplification of the net fluorescence intensity. By sequentially loading brain microdialysate into the dual sample collection loops, the sampling frequency was 7.5h(-1). Based on a 40-µL sample volume, the system's detection limit reached as low as 0.18 mM, sufficiently accurate to determine the extracellular glucose concentrations in living rat brains. To demonstrate the proposed system's practical performance and applicability, we conducted (i) spike analyses of biomolecule-rich fetal bovine serum sample, confirming that the analytical reliability was similar to that of a commercial glucose kit, and (ii) in vivo dynamic monitoring of the extracellular glucose concentrations in living rat brains after inducing neural depolarization by perfusing a high-K(+) medium from the MD probe.


Assuntos
Encéfalo/metabolismo , Cobre/química , Glucose Oxidase/química , Glucose/metabolismo , Monitorização Fisiológica/métodos , Espécies Reativas de Oxigênio/química , Espectrometria de Fluorescência/métodos , Animais , Líquido Extracelular/metabolismo , Íons , Masculino , Sistemas On-Line , Ratos , Ratos Sprague-Dawley
18.
Anal Chem ; 86(16): 8267-74, 2014 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-25025651

RESUMO

Whether silver nanoparticles (AgNPs) degrade and release silver ions (Ag(+)) in vivo has remained an unresolved issue. To evaluate the biodistribution and dissolution behavior of intravenously administered AgNPs in living rats, we employed a knotted reactor (KR) device to construct a differentiation scheme for quantitative assessment of residual AgNPs and their released Ag(+) ions in complicated animal tissues; to do so, we adjusted the operating parameters of the KR, namely, the presence/absence of a rinse solution and the sample acidity. After optimization, our proposed differentiation system was confirmed to be tolerant to rat tissue and organ matrix and provide superior reliability of differentiating AgNPs/Ag(+) than the conventional centrifugal filtration method. We then applied this differentiation strategy to investigate the biodistribution and dissolution of AgNPs in rats 1, 3, and 5 days postadministration, and it was found that the administered AgNPs accumulated predominantly in the liver and spleen, then dissolved and released Ag(+) ions that were gradually excreted, resulting in almost all of the Ag(+) ions becoming deposited in the kidney, lung, and brain. Histopathological data also indicated that toxic responses were specifically located in the AgNP-rich liver, not in the Ag(+)-dominated tissues and organs. Thus, the full-scale chemical fate of AgNPs in vivo should be integrated into future assessments of the environmental health effects and utilization of AgNP-containing products.


Assuntos
Cátions Monovalentes/farmacocinética , Química Farmacêutica/instrumentação , Nanopartículas Metálicas/análise , Prata/farmacocinética , Administração Intravenosa , Animais , Cátions Monovalentes/administração & dosagem , Cátions Monovalentes/análise , Cátions Monovalentes/toxicidade , Desenho de Equipamento , Masculino , Nanopartículas Metálicas/administração & dosagem , Nanopartículas Metálicas/toxicidade , Ratos Sprague-Dawley , Prata/administração & dosagem , Prata/análise , Prata/toxicidade , Solubilidade , Distribuição Tecidual
19.
Anal Chim Acta ; 838: 58-63, 2014 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-25064244

RESUMO

We have developed a simple and low-cost flow injection system coupled to a quadruple ICP-MS for the direct and continuous determination of multi-element in microdialysates. To interface microdialysis sampling to an inductively coupled plasma mass spectrometer (ICP-MS), we employed 3D printing to manufacture an as-designed sample load/inject valve featuring an in-valve sample loop for precise handling of microliter samples with a dissolved solids content of 0.9% NaCl (w/v). To demonstrate the practicality of our developed on-line system, we applied the 3D printed valve equipped a 5-µL sample loop to minimize the occurrence of salt matrix effects and facilitate an online dynamic monitoring of extracellular calcium and zinc ions in living rat brains. Under the practical condition (temporal resolution: 10h(-1)), dynamic profiling of these two metal ions in living rat brain extracellular fluid after probe implantation (the basal values for Ca and Zn were 12.11±0.10mg L(-1) and 1.87±0.05µg L(-1), respectively) and real-time monitoring of the physiological response to excitotoxic stress elicited upon perfusing a solution of 2.5mM N-methyl-d-aspartate were performed.


Assuntos
Encéfalo/metabolismo , Cálcio/metabolismo , Impressão Tridimensional , Zinco/metabolismo , Animais , Desenho Assistido por Computador , Masculino , Ratos , Ratos Sprague-Dawley
20.
Toxicol Lett ; 227(2): 84-90, 2014 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-24704564

RESUMO

With the increasing prevalence of silver nanoparticles (AgNPs) in various products, whether such AgNPs will introduce new injury mechanisms from new pathologies remains to be determined. From the toxicokinetic viewpoint, it is vital to have in-depth knowledge of their in vivo transport kinetics and extravasation phenomenon. By combining push-pull perfusion sampling, in-tube solid phase extraction, and inductively coupled plasma mass spectrometry, we used an in vivo push-pull-based continuous monitoring system to investigate in vivo transport kinetics of extracellular AgNPs in living rat liver with a detection limit and temporal resolution of 0.64µgL(-1) and 10min, respectively. Before administration into living rats, the pre-incubation in DMEM with 10% FBS for 8h was adopted as the optimized exposure condition for the used AgNPs. After repeated-dose treatments, we observed a higher concentration of AgNPs in the liver extracellular space, suggesting that AgNP clearance by the reticuloendothelial system (RES) may be blocked by a prior administration of AgNPs. Future studies on AgNP distribution in different liver compartments (blood stream, extracellular space and Kupffer cells/hepatocytes) are necessary for defining the risks and benefits of AgNP applications.


Assuntos
Espaço Extracelular/química , Fígado/metabolismo , Nanopartículas Metálicas/toxicidade , Monitorização Fisiológica/instrumentação , Prata/farmacocinética , Extração em Fase Sólida/instrumentação , Animais , Estabilidade de Medicamentos , Extravasamento de Materiais Terapêuticos e Diagnósticos , Fígado/química , Fígado/citologia , Masculino , Nanopartículas Metálicas/administração & dosagem , Microscopia Eletrônica de Transmissão , Monitorização Fisiológica/métodos , Ratos , Ratos Sprague-Dawley , Prata/administração & dosagem , Prata/toxicidade , Extração em Fase Sólida/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...