Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
IEEE Trans Med Imaging ; 31(8): 1557-72, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22531755

RESUMO

A 2D/3D nonrigid registration method is proposed that brings a 3D centerline model of the coronary arteries into correspondence with bi-plane fluoroscopic angiograms. The registered model is overlaid on top of interventional angiograms to provide surgical assistance during image-guided chronic total occlusion procedures, thereby reducing the uncertainty inherent in 2D interventional images. The proposed methodology is divided into two parts: global structural alignment and local nonrigid registration. In both cases, vessel centerlines are automatically extracted from the 2D fluoroscopic images, and serve as the basis for the alignment and registration algorithms. In the first part, an energy minimization method is used to estimate a global affine transformation that aligns the centerline with the angiograms. The performance of nine general purpose optimizers has been assessed for this problem, and detailed results are presented. In the second part, a fully nonrigid registration method is proposed and used to compensate for any local shape discrepancy. This method is based on a variational framework, and uses a simultaneous matching and reconstruction process to compute a nonrigid registration. With a typical run time of less than 3 s, the algorithms are fast enough for interactive applications. Experiments on five different subjects are presented and show promising results.


Assuntos
Vasos Coronários/anatomia & histologia , Fluoroscopia/métodos , Imageamento Tridimensional/métodos , Modelos Cardiovasculares , Cirurgia Assistida por Computador/métodos , Algoritmos , Simulação por Computador , Angiografia Coronária , Humanos , Tomografia Computadorizada por Raios X
2.
J Pathol Inform ; 2: S8, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22811964

RESUMO

Several applications such as multiprojector displays and microscopy require the mosaicing of images (tiles) acquired by a camera as it traverses an unknown trajectory in 3D space. A homography relates the image coordinates of a point in each tile to those of a reference tile provided the 3D scene is planar. Our approach in such applications is to first perform pairwise alignment of the tiles that have imaged common regions in order to recover a homography relating the tile pair. We then find the global set of homographies relating each individual tile to a reference tile such that the homographies relating all tile pairs are kept as consistent as possible. Using these global homographies, one can generate a mosaic of the entire scene. We derive a general analytical solution for the global homographies by representing the pair-wise homographies on a connectivity graph. Our solution can accommodate imprecise prior information regarding the global homographies whenever such information is available. We also derive equations for the special case of translation estimation of an X-Y microscopy stage used in histology imaging and present examples of stitched microscopy slices of specimens obtained after radical prostatectomy or prostate biopsy. In addition, we demonstrate the superiority of our approach over tree-structured approaches for global error minimization.

3.
Med Image Comput Comput Assist Interv ; 13(Pt 3): 287-94, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20879411

RESUMO

We present a new image-based respiratory motion compensation method for coronary roadmapping in fluoroscopic images. A temporal analysis scheme is proposed to identify static structures in the image gradient domain. An extended Lucas-Kanade algorithm involving a weighted sum-of-squared-difference (WSSD) measure is proposed to estimate the soft tissue motion in the presence of static structures. A temporally compositional motion model is used to deal with large image motion incurred by deep breathing. Promising results have been shown in the experiments conducted on clinical data.


Assuntos
Artefatos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Fluoroscopia/métodos , Reconhecimento Automatizado de Padrão/métodos , Intensificação de Imagem Radiográfica/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Algoritmos , Humanos , Movimento , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade
4.
Pattern Recognit ; 42(11): 2514-2526, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-20379351

RESUMO

A method for spatio-temporally smooth and consistent estimation of cardiac motion from MR cine sequences is proposed. Myocardial motion is estimated within a 4-dimensional (4D) registration framework, in which all 3D images obtained at different cardiac phases are simultaneously registered. This facilitates spatio-temporally consistent estimation of motion as opposed to other registration-based algorithms which estimate the motion by sequentially registering one frame to another. To facilitate image matching, an attribute vector (AV) is constructed for each point in the image, and is intended to serve as a "morphological signature" of that point. The AV includes intensity, boundary, and geometric moment invariants (GMIs). Hierarchical registration of two image sequences is achieved by using the most distinctive points for initial registration of two sequences and gradually adding less-distinctive points to refine the registration. Experimental results on real data demonstrate good performance of the proposed method for cardiac image registration and motion estimation. The motion estimation is validated via comparisons with motion estimates obtained from MR images with myocardial tagging.

5.
Med Image Comput Comput Assist Interv ; 12(Pt 2): 257-65, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20426120

RESUMO

We propose a method for the analysis of cardiac images with the goal of reconstructing the motion of the ventricular walls. The main feature of our method is that the inversion parameter field is the active contraction of the myocardial fibers. This is accomplished with a biophysically-constrained, four-dimensional (space plus time) formulation that aims to complement information that can be gathered from the images by a priori knowledge of cardiac mechanics. Our main hypothesis is that by incorporating biophysical information, we can generate more informative priors and thus, more accurate predictions of the ventricular wall motion. In this paper, we outline the formulation, discuss the computational methodology for solving the inverse motion estimation, and present preliminary validation using synthetic and tagged MR images. The overall method uses patient-specific imaging and fiber information to reconstruct the motion. In these preliminary tests, we verify the implementation and conduct a parametric study to test the sensitivity of the model to material properties perturbations, model errors, and incomplete and noisy observations.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Movimento/fisiologia , Contração Miocárdica/fisiologia , Função Ventricular Esquerda/fisiologia , Algoritmos , Ventrículos do Coração/anatomia & histologia , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Artigo em Inglês | MEDLINE | ID: mdl-20426135

RESUMO

We propose a novel method to detect the current state of the quasi-periodic system from image sequences which in turn will enable us to synchronize/gate the image sequences to obtain images of the organ system at similar configurations. The method uses the cumulated phase shift in the spectral domain of successive image frames as a measure of the net motion of objects in the scene. The proposed method is applicable to 2D and 3D time varying sequences and is not specific to the imaging modality. We demonstrate its effectiveness on X-Ray Angiographic and Cardiac and Liver Ultrasound sequences. Knowledge of the current (cardiac or respiratory) phase of the system, opens up the possibility for a purely image based cardiac and respiratory gating scheme for interventional and radiotherapy procedures.


Assuntos
Algoritmos , Inteligência Artificial , Técnicas de Imagem de Sincronização Cardíaca/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Oscilometria/métodos , Humanos , Reprodutibilidade dos Testes , Técnicas de Imagem de Sincronização Respiratória , Sensibilidade e Especificidade
7.
Artigo em Inglês | MEDLINE | ID: mdl-18051150

RESUMO

We present a new method for the fast and robust computation of information theoretic similarity measures for alignment of multi-modality medical images. The proposed method defines a non-uniform, adaptive sampling scheme for estimating the entropies of the images, which is less vulnerable to local maxima as compared to uniform and random sampling. The sampling is defined using an octree partition of the template image, and is preferable over other proposed methods of non-uniform sampling since it respects the underlying data distribution. It also extends naturally to a multi-resolution registration approach, which is commonly employed in the alignment of medical images. The effectiveness of the proposed method is demonstrated using both simulated MR images obtained from the BrainWeb database and clinical CT and SPECT images.


Assuntos
Inteligência Artificial , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Armazenamento e Recuperação da Informação/métodos , Reconhecimento Automatizado de Padrão/métodos , Técnica de Subtração , Algoritmos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
J Thorac Cardiovasc Surg ; 130(5): 1364, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16256790

RESUMO

BACKGROUND: Previously, we used cardiopulmonary bypass with incomplete cardiac isolation and antegrade administration of vector for global cardiac gene delivery. Here we present a translatable cardiac surgical procedure that allows for complete surgical isolation of the heart in situ with retrograde (through the coronary venous circulation) administration of both vector and endothelial permeabilizing agents to increase myocyte transduction efficiency. METHODS: In 6 adult dogs the heart was completely isolated with tourniquets placed around both vena cavae and cannulas and all pulmonary veins. On cardiopulmonary bypass, the aorta and pulmonary artery were crossclamped, and the heart was isolated. Crystalloid cardioplegia at 4 degrees C containing 10(13) particles of adenovirus encoding LacZ and 15 microg of vascular endothelial growth factor was infused retrograde into the coronary sinus and recirculated for a total of 30 minutes. The dogs were then weaned from cardiopulmonary bypass and allowed to recover. With a catheter, 3 control dogs underwent retrograde infusion of the same cocktail without cardiac isolation or cardiopulmonary bypass. RESULTS: Beta-galactosidase activities in the cardiopulmonary bypass group were several orders of magnitude higher in both the right and left ventricles when compared with those in the control group (P < .05). X-gal staining from the cardiopulmonary bypass group showed unequivocal evidence of myocyte gene expression globally in a significant proportion of cardiac myocytes. No myocyte gene expression was observed in the control group. CONCLUSION: A novel cardiac surgical technique has been developed. This approach with cardiac isolation and retrograde delivery of vector through the coronary sinus results in efficient myocyte transduction in an adult large animal in vivo.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Terapia Genética/métodos , Miócitos Cardíacos , Animais , Cães
9.
Artigo em Inglês | MEDLINE | ID: mdl-16686046

RESUMO

A 4D image registration method is proposed for consistent estimation of cardiac motion from MR image sequences. Under this 4D registration framework, all 3D cardiac images taken at different time-points are registered simultaneously, and motion estimated is enforced to be spatiotemporally smooth, thereby overcoming potential limitations of some methods that typically estimate cardiac deformation sequentially from one frame to another, instead of treating the entire set of images as a 4D volume. To facilitate our image matching process, an attribute vector is designed for each point in the image to include intensity, boundary and geometric moment invariants (GMIs). Hierarchical registration of two image sequences is achieved by using the most distinctive points for initial registration of two sequences and gradually adding less-distinctive points for refinement of registration. Experimental results on real data demonstrate good performance of the proposed method in registering cardiac images and estimating motions from cardiac image sequences.


Assuntos
Artefatos , Coração/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Armazenamento e Recuperação da Informação/métodos , Imagem Cinética por Ressonância Magnética/métodos , Técnica de Subtração , Algoritmos , Imageamento Tridimensional/métodos , Movimento (Física) , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...