1.
Int J Artif Organs ; 42(12): 717-724, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31250690

RESUMO

INTRODUCTION: The HeartMate 3™ has shown lower rates of adverse events compared to previous devices due to the design and absence of mechanical bearings. For previous devices, sound analysis emerged as a way to assess pump function. The aims of this study were to determine if sound analysis can be applied to the HeartMate 3 in vivo and in vitro and to evaluate an electronic stethoscope. METHOD: Sound recordings were performed with microphones and clinical accessible electronic stethoscope. The recordings were studied in both the time and the frequency domains. Recordings from four patients were performed to determine if in vivo and in vitro recordings are comparable. RESULTS: The results show that it is possible to detect sound from HeartMate 3 and the sound spectrum is clear. Pump frequency and frequency of the pulsatile mode are easily determined. Frequency spectra from in vitro and in vivo recordings have the same pattern, and the major proportion (96.7%) of signal power is located at the pump speed frequency ±40 Hz. The recordings from the patients show low inter-individual differences except from location of peaks originating from pump speed and harmonics. Electronic stethoscopes could be used for sound recordings, but the dedicated equipment showed a clearer sound spectrum. DISCUSSION: The results show that acoustic analysis can also be performed with the HeartMate 3 and that in vivo and in vitro sound spectrum is similar. The frequency spectra are different from previous devices, and methods for assessing pump function or thrombosis need further evaluation.


Assuntos
Análise de Falha de Equipamento , Coração Auxiliar , Som , Desenho de Equipamento , Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/métodos , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar/efeitos adversos , Coração Auxiliar/normas , Humanos , Magnetometria/métodos , Masculino , Pessoa de Meia-Idade , Melhoria de Qualidade , Análise Espectral/métodos
2.
Oxf Med Case Reports ; 2018(12): omy106, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30487991

RESUMO

Myocarditis is mostly caused by viral infections and rarely caused by bacterial pathogens, especially in immunocompetent individuals. Bacterial myocarditis due to Salmonella is rare, especially in countries with improved sanitation that minimize contamination of Salmonella typhi serotypes. We here present a case of a previous healthy 22-year-old male that came to the emergency room with chest pain. His symptoms occurred after a period of profuse diarrhea, fever and hematochezia. Magnetic resonance imaging confirmed the diagnosis of myocarditis. Stool culture was positive for Salmonella enteritidis. Myocarditis due to Salmonella is rare but may still occur in western countries. The inter-individual response to the pathogens and its virulence mechanisms and male gender is factors for developing myocarditis. We here add to the numbers of cases with myocarditis due to S. enteritidis. A higher suspicion and more frequent ECG and troponin testing might result in an increase of patients with subclinical myocarditis.

3.
Int J Artif Organs ; 41(5): 254-260, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29519192

RESUMO

INTRODUCTION: The use of left ventricular assist device (LVAD) has grown rapidly. Adverse events do continue to occur. In recent years, analysis of LVAD sound recordings emerged as a means to monitor pump function and detect pump thrombosis. The aim of this study was to characterize the sounds from HeartMate II and to evaluate the use of handheld iOS devices for sound recordings. METHOD: Signal analysis of LVAD sound recordings, with dedicated recording equipment and iOS devices, was performed. Two LVADs running in mock loop circuits were compared to an implanted LVAD. Spectral analysis and parametric signal models were explored to quantify the sound and potentially detect changes in it. RESULTS: The sound recordings of two LVADs in individual mock loop circuits and a third one implanted in a patient appeared to be similar. Qualitatively, sound characteristics were preserved following changes in pump speed. Recordings using dedicated equipment showed that HeartMate II sound comprises low-frequency components corresponding to pump impeller rotation, as well as high-frequency components due to a pulse width modulation of the electric power to the pump. These different signal components interact and result in a complicated frequency spectrum. The iPhone and iPod recordings could not reproduce the sounds as well as the dedicated equipment. In particular, lower frequencies were affected by outside disturbances. DISCUSSION: This article outlines a systematic approach to LVAD sound analysis using signal processing methods to quantify and potentially detect changes, and describes some of the challenges, for example, with the use of inexpensive recording devices.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Falha de Equipamento , Humanos
4.
Oxf Med Case Reports ; 2017(2): omx003, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28473916

RESUMO

Progressive multifocal leukoencephalopathy (PML), caused by reactivation of JC-virus is a relatively rare complication seen in patients with compromised immune system. There are no evidence-based treatment available and prognosis is poor. Withdrawal of immunosuppressant can result in further neurological deterioration and for patients with solid organ transplantations, fatal graft rejection. We report a 52-year-old women that presented with seizures within 1 month after heart transplantation. Initial diagnosis was vascular disease. After clinical deterioration 10 months after transplantation, further examinations led to the diagnosis. Minimizing tacrolimus, to a concentration of 2 ng/ml, and extensive physical therapy has improved the physical capacity of the patient. The patient has now been clinically stable for 4 years and extended survival for 5 years. This case adds to the limited adult cases of PML within the population of heart transplant recipients and the need for increased awareness to minimize diagnosis delay.

5.
ASAIO J ; 60(6): e3-4, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25232773

RESUMO

Cardiotoxicity is a multifactorial problem, which has emerged with the improvement of cancer therapies and survival. Heart transplantation is relatively contraindicated in patients with breast cancer, until at least 5 years after complete remission. We present a case where a young woman who in 2001, at the age of 31, was diagnosed with breast cancer. She was considered cured, but 4 years later she suffered a relapse. During her second treatment, in 2006, she suffered from severe heart failure. She received a HeartMate II, as a long-term bridge to transplantation and 6 years later she was successfully transplanted. In this case report we discuss the use of mechanical circulatory support in cancer patients with drug-induced heart failure.


Assuntos
Neoplasias da Mama/complicações , Carcinoma Ductal de Mama/complicações , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Adulto , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Neoplasias da Mama/terapia , Carcinoma Ductal de Mama/terapia , Feminino , Transplante de Coração , Humanos , Recidiva Local de Neoplasia/complicações , Recidiva Local de Neoplasia/terapia , Fatores de Tempo
6.
Artif Organs ; 38(7): 593-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24372095

RESUMO

Mechanical circulatory support technology is continually improving. However, adverse complications do occur with devastating consequences, for example, pump thrombosis that may develop in several parts of the pump system. The aim of this study was to design an experimental clot/thrombosis model to register and analyze acoustic signals from the left ventricular assist device (LVAD) HeartMate II (HMII) (Thoratec Corporation, Inc., Pleasanton, CA, USA) and detect changes in sound signals correlating to clots in the inflow, outflow, and pump housing. Using modern telecom techniques, it was possible to register and analyze the HMII pump-specific acoustic fingerprint in an experimental model of LVAD support using a mock loop. Increase in pump speed significantly (P<0.005) changed the acoustic fingerprint at certain frequency (0-23,000 Hz) intervals (regions: R1-3 and peaks: P1,3-4). When the ball valves connected to the tubing were narrowed sequentially by ∼50% of the inner diameter (to mimic clot in the out- and inflow tubing), the frequency spectrum changed significantly (P<0.005) in P1 and P2 and R1 when the outflow tubing was narrowed. This change was not seen to the same extent when the lumen of the ball valve connected to the inflow tube was narrowed by ∼50%. More significant (P<0.005) acoustic changes were detected in P1 and P2 and R1 and R3, with the largest dB figs. in the lower frequency ranges in R1 and P2, when artificial clots and blood clots passed through the pump system. At higher frequencies, a significant change in dB figs. in R3 and P4 was detected when clots passed through the pump system. Acoustic monitoring of pump sounds may become a valuable tool in LVAD surveillance.


Assuntos
Acústica/instrumentação , Coração Auxiliar/efeitos adversos , Trombose/diagnóstico , Trombose/etiologia , Humanos