Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 21347, 2023 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-38049493

RESUMO

This study aimed to test the efficacy of different silica-based toothpastes with or without chitosan, as a method of cleaning the acrylic surfaces of denture prostheses. Acrylic resin specimens were prepared to evaluate surface roughness and gloss (n = 10), and Candida albicans adhesion/inhibition (n = 2). Two toothpastes with different degrees of abrasiveness were used: Colgate (CT) and Elmex (EX), with or without 0.5% chitosan (Ch) microparticles (CTCh or EXCh, respectively). The negative control was brushed with distilled water. Brushing was simulated with a machine. Surface roughness and gloss were analyzed before and after brushing. Candida albicans incidence/inhibition was tested qualitatively to determine the acrylic resin antifungal activity. The roughness and gloss data were analyzed with a generalized linear model, and the Kruskal Wallis and Dunn tests, respectively (α = 5%). Brushing with toothpastes increased roughness and reduced gloss, compared with the negative control (p < 0.05). CT showed a more significantly different change in roughness and gloss, in relation to the other groups (p < 0.05). Addition of chitosan to CT reduced its abrasive potential, and yielded results similar to those of EX and EXCh. Specimens brushed with CT showed a higher potential for Candida albicans adherence, despite its higher antifungal action. Addition of chitosan to the toothpaste made both toothpaste and brushing more effective in inhibiting Candida albicans. CT had the potential to increase roughness, reduce gloss, and increase Candida albicans adherence. In contrast, chitosan added to CT showed greater antifungal potential, and a higher synergistic effect than EX.


Assuntos
Quitosana , Cremes Dentais , Cremes Dentais/farmacologia , Antifúngicos/farmacologia , Quitosana/farmacologia , Propriedades de Superfície , Resinas Acrílicas/farmacologia , Candida albicans , Fluoreto de Sódio
2.
J Appl Oral Sci ; 31: e20230181, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37820182

RESUMO

The effectiveness of at-home dental bleaching treatments depends on the time that bleaching products are in contact with the teeth surface and, consequently, on the adequate use of associated custom acetate trays. OBJECTIVE: This randomized single-blinded trial aimed to analyze if the daily usage time of these products influences the patient's compliance behavior when submitted to monitored at-home dental bleaching. Secondary outcomes were color change and tooth sensitivity. METHODOLOGY: Sixty-six volunteers were randomly distributed into three groups (n=22): patients were instructed to use the trays for 2 (G2), 4 (G4), and 8 (G8) hours daily. The daily dental bleaching compliance behavior was measured using a microsensor inserted into the trays. Subjective and objective color evaluation assessments were adopted at baseline (T0), one (T1), two (T2), and three weeks (T3) after the beginning of the bleaching treatment, as well as two weeks after the treatment (T4). Tooth sensitivity was analyzed using the VAS scale, ranging from T1 to T4. RESULTS: G2 showed a greater degree of cooperation than G8 and cooperation was inversely proportional to the recommended usage time. Significantly higher color change was observed in the upper arch for G8 when compared to G2 in subjective analysis, from T1 to T4. There were no statistical differences between the groups in objective analysis. CONCLUSION: Shorter recommended usage time of the bleaching product may improve the patient's compliance with at-home dental bleaching treatments. However, increased daily usage time may promote better subjective color change. Bleaching sensitivity was more significant in the first week for a longer time of use.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Peróxido de Hidrogênio , Resultado do Tratamento
3.
J. appl. oral sci ; 31: e20230181, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1514415

RESUMO

Abstract The effectiveness of at-home dental bleaching treatments depends on the time that bleaching products are in contact with the teeth surface and, consequently, on the adequate use of associated custom acetate trays. Objective This randomized single-blinded trial aimed to analyze if the daily usage time of these products influences the patient's compliance behavior when submitted to monitored at-home dental bleaching. Secondary outcomes were color change and tooth sensitivity. Methodology Sixty-six volunteers were randomly distributed into three groups (n=22): patients were instructed to use the trays for 2 (G2), 4 (G4), and 8 (G8) hours daily. The daily dental bleaching compliance behavior was measured using a microsensor inserted into the trays. Subjective and objective color evaluation assessments were adopted at baseline (T0), one (T1), two (T2), and three weeks (T3) after the beginning of the bleaching treatment, as well as two weeks after the treatment (T4). Tooth sensitivity was analyzed using the VAS scale, ranging from T1 to T4. Results G2 showed a greater degree of cooperation than G8 and cooperation was inversely proportional to the recommended usage time. Significantly higher color change was observed in the upper arch for G8 when compared to G2 in subjective analysis, from T1 to T4. There were no statistical differences between the groups in objective analysis. Conclusion Shorter recommended usage time of the bleaching product may improve the patient's compliance with at-home dental bleaching treatments. However, increased daily usage time may promote better subjective color change. Bleaching sensitivity was more significant in the first week for a longer time of use.

4.
J Prosthet Dent ; 2022 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-35843750

RESUMO

STATEMENT OF PROBLEM: Achieving accurate tooth color is important in esthetic dental treatments; however, clinical studies evaluating how ceramic veneer procedures affect color alterations are lacking. PURPOSE: The purpose of this clinical study was to assess the color alteration during treatment with ceramic veneers and to correlate these changes with the tooth treated and veneer thickness. MATERIAL AND METHODS: Ten patients who underwent esthetic treatment were enrolled as participants. Color analysis with the VITA spectrophotometer was performed at baseline, after tooth preparation, immediately after cementation (Final 1), and after 6 to 12 months of follow-up (Final 2). Data of L∗, a∗, b∗, shade guide unit (SGU), ΔEab, ΔE00, and variation in SGU (ΔSGU) were obtained. Thickness of the veneer was also recorded. Each participant was considered as a statistical block, and the mean results for each tooth (maxillary central incisors, lateral incisors, and canines) were presented. Data were evaluated by the mixed model for repeated measures and Tukey-Kramer post hoc test (L∗, a∗, b∗), generalized linear models (thickness, ΔEab, ΔE00, SGU), Friedman test (ΔSGU), and the Pearson test was used to correlate veneer thickness and color change (ΔEab, ΔE00, ΔSGU) (α=.05). RESULTS: Among the teeth treated, no differences were found in ceramic thicknesses. The mean thickness was 1.03 mm for central incisors, 0.96 for lateral incisors, and 0.89 for canines. The b∗ values increased significantly after preparation and decreased after cementation (P<.001). For ΔEab, ΔE00, and ΔSGU, there was no statistically significant difference between the types of tooth at each respective time of analysis (P>.05). Regardless of the tooth, a decrease in the SGU score was detected after cementation (P=.015). After tooth preparation, there was significant correlation (P<.05) between ceramic thickness and ΔSGU (r=0.36). CONCLUSIONS: Treatment with ceramic veneers resulted in color change, mainly with respect to the b∗ axis (yellow), producing objective differences in the ΔE analysis. Although ceramic thickness correlated with the VITA scale change (ΔSGU) after tooth wear or preparation, ceramic thickness did not differ among tooth types and did not correlate with changes in color parameters after cementation. (P>.05).

5.
Eur J Dent ; 14(S 01): S14-S19, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32882738

RESUMO

OBJECTIVE: This survey aimed to assess the effects of coronavirus disease 2019 (COVID-19) on elective and urgency/emergency dental care and dentists concerned. MATERIALS AND METHODS: A web-based survey was performed using Google forms questionnaire sent to dentists in Brazil. Questions included: personal information, type of dental care provided during quarantine, if emergencies increased, the dental office biosafety routine, among others. The levels of concern about the impact of quarantine on dental care and patient oral health conditions and the economic impact on dental practices were evaluated using a 0- to 10-point scale. Statistical analysis included descriptive, percentages, one-way ANOVA, Tukey, and chi-square tests. RESULTS: During quarantine, 64.6% of the dentists attended only urgency/emergency treatments, while 26.1% maintained routine appointments, and 9.3% closed the dental offices. A higher percentage of dentists from the least affected states continued routine dental treatment; dentists were younger and presented a significantly lower level of concern about dental treatments and oral health conditions of their patients. An increase in urgency/emergency procedures was reported by 44.1% of the dentists, mostly due to the unavailability of routine/elective dental care and increased patient anxiety and stress. The main causes of urgency/emergency appointments were toothache, dental trauma, and broken restorations, besides the breakage of orthodontic appliances and temporomandibular disorders. Dentists reported a high level of concern about the economic impact caused by quarantine. CONCLUSIONS: The pandemic/quarantine has negatively affected the clinical routine. Personal protection/hygiene care must be adopted and reinforced by dental professionals/staff to make dental procedures safer.

6.
J Conserv Dent ; 22(4): 401-405, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31802828

RESUMO

This clinical report describes the enamel microabrasion technique for removing maxillary and mandibular hard fluorotic enamel stains followed by home-monitored home dental bleaching. The removal of fluorotic enamel stains utilized macroabrasion with a water-cooled, fine-tapered 3195 FF diamond bur followed microabrasion with the application of Prema Compound (Premier Dental Products Co, Norristown, PA, USA). Home-monitored dental bleaching was performed 14 days after enamel microabrasion using a 10% carbamide peroxide gel for 2 h/day. The wearing time of the acetate tray/dental bleaching was quantified by a microsensor from TheraMon microelectronic system (Sales Agency Gschladt, Hargelsberg, Austria) that was completely embedded in the acetate trays. The teeth were bleached effectively during 23 days. The mean wearing time of the acetate trays/dental bleaching product was 1.54 h/day, for the upper and lower arches. The patient reported satisfaction with the treatment. The association of enamel microabrasion and home dental bleaching was an excellent clinical treatment for teeth affected with enamel fluorosis.

7.
Sci Rep ; 9(1): 2286, 2019 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-30783177

RESUMO

Stress of polymerization is one of the most significant drawbacks of dental resin composites, since it is related to poor marginal adaptation, postoperative pain, and secondary caries. Previous studies have shown that thiourethane oligomers incorporated into the organic matrix represents a promising strategy to reduce stress and increase fracture toughness in dental composites. However, this strategy promotes a significant increase of the viscosity system, which may represent a challenge for clinical application. The objective of this study was to functionalize the surface of inorganic filler particles with thiouretanes and evaluate the impact on mechanical properties and kinetics of polymerization. Our results showed that composites filled with thiourethane-silanized inorganic fillers showed up to 35% lower stress while doubling mechanical properties values. This was achieved with no prejudice to the viscosity of the material and following a clinically acceptable photoactivation protocol.


Assuntos
Resinas Acrílicas/química , Resinas Compostas/química , Poliuretanos/química , Uretana/química , Teste de Materiais , Microscopia , Polimerização
8.
Clin Oral Investig ; 23(1): 321-326, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29679230

RESUMO

OBJECTIVES: The present dental bleaching case report describes a new method that precisely quantifies the daily wearing-times of the bleaching product by inserting a microsensor in the acetate custom tray. The bleaching efficacy was also discussed since the patient was previously submitted to enamel microabrasion. METHODS: The patient was submitted to enamel microabrasion in 1987, and bleaching treatment was performed in 2005. In 2017, re-bleaching was executed using 10% peroxide carbamide. The electronic microsensor, TheraMon (TheraMon® microelectronic system; Sales Agency Gschladt, Hargelsberg, Austria), was embedded in the labial region of the upper and lower acetate trays to evaluate the wearing-times of the acetate trays/bleaching product. The patient was instructed to wear the tray for 6 to 8 h/day while sleeping. After 24 days of bleaching treatment, the data obtained from the TheraMon electronic devices was collected and interpreted. RESULTS: The patient did not entirely follow the bleaching treatment as recommended, as there was no evidence of use of the upper and lower trays for some days; additionally, the bleaching product was used for shorter and longer periods than was instructed. CONCLUSIONS: The TheraMon microeletronic device precisely measured the wearing-times of the acetate tray/bleaching product during the bleaching treatment. Teeth submitted to enamel microabrasion presented with a healthy clinical appearance after 30 years. CLINICAL SIGNIFICANCE: Measuring the length and frequency of use of an acetate tray/bleaching product can be important to clinicians and patients for obtaining a controlled and adequate bleaching treatment.


Assuntos
Microabrasão do Esmalte , Cooperação do Paciente , Clareamento Dental/métodos , Adolescente , Feminino , Humanos , Tecnologia de Sensoriamento Remoto
9.
Braz Oral Res ; 32: e43, 2018 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-29846386

RESUMO

To investigate how the hydrofluoric acid (HF) concentrations applied to a lithium disilicate glass-ceramic (EMX) affects the surface morphology and microtensile bond strength (µTBS) of ceramics to dentin, using light-cured resin cements with or without UDMA. Sixty-three EMX square ceramic blocks were etched for 20 seconds using different HF concentrations (1%, 5% and 10%) and luted to dentin using two types of resin cement combinations: BisGMA/TEGDMA and BisGMA/TEGDMA/UDMA (n = 10). Each bonded EMX-dentin block was sectioned to obtain 1 mm2 sticks for µTBS evaluation. Half of the sticks were tested after 24 hours and the other half was assessed after 6 months of water storage. Data were statistically assessed using split-plot three-way ANOVA and multiple comparisons were performed using the Tukey's post hoc test (α = 0.05). One EMX sample from each HF concentration was analyzed using field-emission scanning electron microscope (FE-SEM) to characterize the etching pattern. According to the FE-SEM images, increasing the concentration of HF from 1 to 5 and then to 10% led to increased removal of glassy matrix and greater exposure of lithium disilicate crystals. The 10% HF concentration yielded higher µTBS when compared to 1% for BisGMA/TEGDMA formulation (p < 0.05); whereas HF 1% and 5% showed similar µTBS values when compared to 10% HF for BisGMA/TEGDMA/UDMA resin matrix (p > 0.05) at both storage times. Water aging decreased the µTBS values (p < 0.05), except when 10% HF was associated with BisGMA/TEGDMA resin cement. Resin cement formulation and hydrofluoric acid concentrations can interfere with the immediate and long-term glass-ceramic bond strength to dentin.


Assuntos
Cerâmica/química , Colagem Dentária/métodos , Porcelana Dentária/química , Ácido Fluorídrico/química , Cimentos de Resina/química , Análise do Estresse Dentário , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Resistência à Tração
10.
Braz. oral res. (Online) ; 32: e43, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889490

RESUMO

Abstract To investigate how the hydrofluoric acid (HF) concentrations applied to a lithium disilicate glass-ceramic (EMX) affects the surface morphology and microtensile bond strength (μTBS) of ceramics to dentin, using light-cured resin cements with or without UDMA. Sixty-three EMX square ceramic blocks were etched for 20 seconds using different HF concentrations (1%, 5% and 10%) and luted to dentin using two types of resin cement combinations: BisGMA/TEGDMA and BisGMA/TEGDMA/UDMA (n = 10). Each bonded EMX-dentin block was sectioned to obtain 1 mm2 sticks for μTBS evaluation. Half of the sticks were tested after 24 hours and the other half was assessed after 6 months of water storage. Data were statistically assessed using split-plot three-way ANOVA and multiple comparisons were performed using the Tukey's post hoc test (α = 0.05). One EMX sample from each HF concentration was analyzed using field-emission scanning electron microscope (FE-SEM) to characterize the etching pattern. According to the FE-SEM images, increasing the concentration of HF from 1 to 5 and then to 10% led to increased removal of glassy matrix and greater exposure of lithium disilicate crystals. The 10% HF concentration yielded higher μTBS when compared to 1% for BisGMA/TEGDMA formulation (p < 0.05); whereas HF 1% and 5% showed similar μTBS values when compared to 10% HF for BisGMA/TEGDMA/UDMA resin matrix (p > 0.05) at both storage times. Water aging decreased the μTBS values (p < 0.05), except when 10% HF was associated with BisGMA/TEGDMA resin cement. Resin cement formulation and hydrofluoric acid concentrations can interfere with the immediate and long-term glass-ceramic bond strength to dentin.


Assuntos
Cerâmica/química , Colagem Dentária/métodos , Cimentos de Resina/química , Porcelana Dentária/química , Ácido Fluorídrico/química , Propriedades de Superfície , Resistência à Tração , Teste de Materiais , Microscopia Eletrônica de Varredura , Análise do Estresse Dentário
11.
Caries Res ; 51(6): 543-553, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28977796

RESUMO

The study aim was to investigate the effect of antierosive agents on enamel under normal and hyposalivatory conditions. This double-blind crossover in situ pilot study evaluated 4 toothpastes: placebo (0 ppm F), sodium fluoride (NaF, 1,450 ppm), stannous/sodium fluoride (SnF/NaF, 1,450 ppm F-, 1,090 ppm Sn2+), and sodium fluoride, stannous chloride and chitosan (NaF/Sn/Ch, 1,450 ppm F-, 3,500 ppm Sn2+, 0.5% Ch). Twenty participants were assigned to 2 groups (n = 10 each): normal and low salivary flow. Participants wore palatal appliances holding 4 bovine enamel specimens previously eroded in vitro (D1) for 20 min prior to an in situ phase after which they were eroded again (D2). Surface microhardness was determined at baseline (BL), after D1, in situ phase and D2 to assess hardness loss (%SMH), residual hardness loss (%RHL) and erosion resistance (%RER). Additional specimens were evaluated by scanning electron microscopy after the in situ phase. ANOVA and a factorial analysis for between-subject effects were performed. Sn-based toothpastes showed the best effects (p < 0.05). Under normal flow, SnF/NaF showed higher efficacy, with a significant difference compared to NaF/Sn/Ch, NaF, and placebo (p < 0.05). Under low flow, SnF/NaF and NaF/Sn/Ch were comparable (p > 0.05); NaF and placebo were statistically similar. Comparing salivary conditions, there were significant differences for SnF/NaF for %SMH after the in situ phase (%SMHtotal)), %RHL and for all toothpastes in case of %RER. Factorial analysis revealed interactions between toothpaste and saliva flow for %SMHtotal and %RHL. Salivary flow can influence the efficacy of the antierosive toothpastes; however, Sn2+ preparations show even under low salivary flow conditions the highest efficacy in the prevention of enamel erosion.

12.
Braz Dent J ; 27(6): 727-733, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27982186

RESUMO

The aim of this study was to evaluate the effects of hydrofluoric acid (HF) concentration and previous heat treatment (PHT) on the surface morphology and micro-shear bond strength (mSBS) of a lithium disilicate glass ceramic (EMX) to resin cement. One hundred four EMX specimens were randomly assigned to two groups (n=52) according to the HF concentration: 5% and 10%. A new random distribution was made according to the PHTs (n=13): control (no PHT); previously heated HF (70 °C); previously heated EMX surface (85 °C); the combination of heated HF + heated EMX surface. The etching time was set at 20 s. All EMX blocks were silanated and received a thin layer of an unfilled resin. Five resin cement cylinders were made on each EMX surface using Tygon tubes as matrices, and then stored for 24 h at 37 °C. One random etched EMX sample from each group was analyzed using field-emission scanning electron microscopy (FE-SEM). The data were subjected to two-way ANOVA and multiple comparisons were performed using the Tukey post hoc test (a=0.05). For the control groups, 5% HF showed statistically lower mSBS values when compared to 10% HF (p<0.05). PHT increased the mSBS values for 5% HF, yielding statistically similar results to non-PHT 10% HF (p<0.05). FE-SEM images showed increased glassy matrix removal when PHT was applied to HF 5%, but not to the same degree as for 10% HF. PHT has the potential to improve the bond strength of 5% HF concentration on lithium disilicate glass ceramic.


Assuntos
Cerâmica , Colagem Dentária , Porcelana Dentária/química , Temperatura Alta , Ácido Fluorídrico/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina
13.
Braz. dent. j ; 27(6): 727-733, Nov.-Dec. 2016. graf
Artigo em Inglês | LILACS | ID: biblio-828060

RESUMO

Abstract The aim of this study was to evaluate the effects of hydrofluoric acid (HF) concentration and previous heat treatment (PHT) on the surface morphology and micro-shear bond strength (mSBS) of a lithium disilicate glass ceramic (EMX) to resin cement. One hundred four EMX specimens were randomly assigned to two groups (n=52) according to the HF concentration: 5% and 10%. A new random distribution was made according to the PHTs (n=13): control (no PHT); previously heated HF (70 °C); previously heated EMX surface (85 °C); the combination of heated HF + heated EMX surface. The etching time was set at 20 s. All EMX blocks were silanated and received a thin layer of an unfilled resin. Five resin cement cylinders were made on each EMX surface using Tygon tubes as matrices, and then stored for 24 h at 37 °C. One random etched EMX sample from each group was analyzed using field-emission scanning electron microscopy (FE-SEM). The data were subjected to two-way ANOVA and multiple comparisons were performed using the Tukey post hoc test (a=0.05). For the control groups, 5% HF showed statistically lower mSBS values when compared to 10% HF (p<0.05). PHT increased the mSBS values for 5% HF, yielding statistically similar results to non-PHT 10% HF (p<0.05). FE-SEM images showed increased glassy matrix removal when PHT was applied to HF 5%, but not to the same degree as for 10% HF. PHT has the potential to improve the bond strength of 5% HF concentration on lithium disilicate glass ceramic.


Resumo O objetivo deste estudo foi avaliar os efeitos das concentrações de ácido fluorídrico (AF) e do prévio tratamento térmico (PTT) na morfologia da superfície e resistência de união ao microcisalhamento (mRUM) de uma cerâmica vítrea de dissilicato de lítio (EMX) ao cimento resinoso. Cento e quatro espécimes de EMX foram aleatoriamente distribuídos em dois grupos (n=52) de acordo com a concentração do AF: 5% e 10%. Os espécimes foram novamente distribuídos de forma aleatória de acordo com o PTT (n=13): controle (sem PTT); AF previamente aquecido (70 °C); superfície do EMX previamente aquecida (85 °C); combinação entre AF e EMX aquecidos. O tempo de condicionamento foi fixado em 20 s. Todos os espécimes de EMX foram silanizados e receberam a aplicação de uma fina camada de um adesivo sem carga. Cinco cilindros de cimento resinoso foram confeccionados usando tubos Tygon como matrizes e então armazenados por 24 h a 37 °C. Uma amostra condicionada de cada grupo foi aleatoriamente selecionada e analisada em um microscópio eletrônico de varredura em emissão de campo (MEVEC). Os dados foram submetidos ao teste ANOVA de dois fatores e múltiplas comparações foram feitas pelo teste de Tukey (a=0.05). Para os grupos controle, AF 5% mostrou valor de mRUM estatisticamente menor do que AF 10% (p<0.05). PTT aumentou os valores de mRUM para o AF 5%, proporcionando resultados estatisticamente similares ao grupo AF 10% controle (p<0.05). MEVEC mostrou um aumento na remoção da matriz vítrea quando o PTT foi aplicado ao grupo AF 5%, no entanto esse efeito não foi visto no grupo AF 10%. O PTT tem o potencial de melhorar a resistência de união do AF 5% na cerâmica vítrea reforçada por disilicato de lítio.


Assuntos
Cerâmica , Colagem Dentária , Porcelana Dentária/química , Temperatura Alta , Ácido Fluorídrico/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina
14.
Compend Contin Educ Dent ; 37(9): e1-e4, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27700126

RESUMO

This longitudinal study evaluated the clinical performance of 97 direct class I resin composite restorations after 3 years. The restorations were performed using 2 types of adhesive systems: (1) Adper™ Single Bond Plus (SB) (3M ESPE, 3mespe.com), which is a two-step etch-and-rinse system, and (2) Adper Scotchbond™ SE (SE) (3M ESPE), which is a two-step self-etching system. Two calibrated examiners evaluated the restorations using modified US Public Health Service criteria. The materials were applied following the manufacturer's instructions, and 15 patients received at least one of the two adhesive systems. The restorations were evaluated 7 days after placement (baseline) and again after 3 years. Statistical analysis was performed using a proportion t-test at a significance level of 5% (P < .05). At baseline, all restorations received an Alpha score for the variable marginal discoloration and marginal integrity. After 3 years, marginal discoloration received an Alpha score for 53.19% of the restorations performed with SB and 52.08% with SE. Marginal integrity was rated as Alpha for 65.96% and 68.75% of the restorations with SB and SE systems, respectively. The remaining restorations received Bravo scores for all variables. Eight restored teeth presented postoperative sensitivity at baseline (5 SB; 3 SE), but no sensitivity was found after 3 years. No secondary caries was verified. No statistically significant differences were observed between the teeth restored with the SB and SE systems for marginal discoloration (P = .7880) and marginal integrity (P = .8132) after 3 years. Direct class I resin composite restorations performed with a two-step etch-and-rinse and a two-step self-etching adhesive system demonstrated satisfactory clinical performance after 3 years.


Assuntos
Cimentos Dentários/uso terapêutico , Restauração Dentária Permanente , Resinas Acrílicas/uso terapêutico , Adolescente , Bis-Fenol A-Glicidil Metacrilato/uso terapêutico , Resinas Compostas/uso terapêutico , Cárie Dentária/cirurgia , Corrosão Dentária/métodos , Sensibilidade da Dentina , Adesivos Dentinários/uso terapêutico , Feminino , Humanos , Estudos Longitudinais , Masculino , Poliuretanos/uso terapêutico , Fatores de Tempo , Adulto Jovem
15.
Bioinformatics ; 32(8): 1238-40, 2016 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-26704597

RESUMO

MOTIVATION: Structured RNAs can be hard to search for as they often are not well conserved in their primary structure and are local in their genomic or transcriptomic context. Thus, the need for tools which in particular can make local structural alignments of RNAs is only increasing. RESULTS: To meet the demand for both large-scale screens and hands on analysis through web servers, we present a new multithreaded version of Foldalign. We substantially improve execution time while maintaining all previous functionalities, including carrying out local structural alignments of sequences with low similarity. Furthermore, the improvements allow for comparing longer RNAs and increasing the sequence length. For example, lengths in the range 2000-6000 nucleotides improve execution up to a factor of five. AVAILABILITY AND IMPLEMENTATION: The Foldalign software and the web server are available at http://rth.dk/resources/foldalign CONTACT: gorodkin@rth.dk SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Assuntos
RNA/química , Alinhamento de Sequência/métodos , Análise de Sequência de RNA/métodos , Software , Transcriptoma
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...