Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMJ Open ; 12(12): e065790, 2022 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-36564107

RESUMO

OBJECTIVE: Patient monitoring in general wards primarily involves intermittent observation of temperature, heart rate (HR), respiratory rate (RR) and blood pressure performed by the nursing staff. Several hours can lapse between such measurements, and the patient may go unobserved. Despite the growing widespread use of sensors to monitor vital signs and physical activities of healthy individuals, most acutely ill hospitalised patients remain unmonitored, leaving them at an increased risk. We investigated whether a contactless monitoring system could measure vital parameters, such as HR and RR, in a real-world hospital setting. DESIGN: A cross-sectional prospective study. SETTING AND PARTICIPANTS: We examined the suitability of employing a non-contact monitoring system in a low-acuity setup at a tertiary care hospital in India. Measurements were performed on 158 subjects, with data acquired through contactless monitoring from the general ward and dialysis unit. OUTCOME MEASURES: Vital parameters (RR and HR) were measured using a video camera in a non-acuity setting. RESULTS: Three distinct combinations of contactless monitoring afforded excellent accuracy. Contactless RR monitoring was linearly correlated with Alice NightOne and manual counts, presenting coefficients of determination of 0.88 and 0.90, respectively. Contactless HR monitoring presented a coefficient of determination of 0.91. The mean absolute errors were 0.84 and 2.15 beats per minute for RR and HR, respectively. CONCLUSIONS: Compared with existing Food and Drug Administration-approved monitors, the findings of the present study revealed that contactless monitoring of RR and HR accurately represented study populations in non-acuity settings. Contactless video monitoring is an unobtrusive and dependable method for monitoring and recording RR and HR. Further research is needed to validate its dependability and utility in other settings, including acute care. TRIAL REGISTRATION NUMBER: CTRI/2018/11/016246.


Assuntos
Diálise Renal , Taxa Respiratória , Humanos , Frequência Cardíaca/fisiologia , Taxa Respiratória/fisiologia , Estudos Transversais , Estudos Prospectivos , Monitorização Fisiológica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...