Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 15(3): 4495, 2014 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-24892330

RESUMO

The aim of this study was to assess the performance of a gantry-mounted detector system and a couch set detector system using a systematic multileaf collimator positional error manually introduced for volumetric-modulated arc therapy. Four head and neck and esophagus VMAT plans were evaluated by measurement using an electronic portal imaging device and an ion chamber array. Each plan was copied and duplicated with a 1 mm systematic MLC positional error in the left leaf bank. Direct comparison of measurements for plans with and without the error permitted observational characteristics for quality assurance performance between detectors. A total of 48 different plans were evaluated for this testing. The mean percentage planar dose differences required to satisfy a 95% match between plans with and without the MLCPE were 5.2% ± 0.5% for the chamber array with gantry motion, 8.12% ± 1.04% for the chamber array with a static gantry at 0°, and 10.9%± 1.4% for the EPID with gantry motion. It was observed that the EPID was less accurate due to overresponse of the MLCPE in the left leaf bank. The EPID always images bank-A on the ipsilateral side of the detector, whereas for a chamber array or for a patient, that bank changes as it crosses the -90° or +90° position. A couch set detector system can reproduce the TPS calculated values most consistently. We recommend it as the most reliable patient specific QA system for MLC position error testing. This research is highlighted by the finding of up to 12.7% dose variation for H/N and esophagus cases for VMAT delivery, where the mere source of error was the stated clinically acceptability of 1 mm MLC position deviation of TG-142.


Assuntos
Leitos , Análise de Falha de Equipamento/instrumentação , Posicionamento do Paciente/instrumentação , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Desenho de Equipamento , Radiometria/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Med Phys ; 33(6): 1552-61, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16872062

RESUMO

The present work is primarily focused on the estimation of relative dose distribution and effective transmission around a shielded vaginal cylinder with an 192Ir source using the Monte Carlo technique. The MCNP4B code was used to evaluate the dose distribution around a tungsten shielded vaginal cylinder as a function of thickness and angular shielding. The dose distribution and effective transmission of 192Ir by 0.8 cm thickness tungsten were also compared with that for gold and lead. Dose distributions were evaluated for different distances starting from 1.35 cm to 10.15 cm from the center of the cylinder. Dose distributions were also evaluated sequentially from 0 degrees to 180 degrees for every 5 degrees interval. Studies show that all the shielding material at 0.8 cm thickness contribute tolerable doses to normal tissues and also protect the critical organs such as the rectum and bladder. However, the computed dose values are in good agreement with the reported experimental values. It was also inferred that the higher the shielding angles, the more the protection of the surrounding tissues. Among the three shielding materials, gold has been observed to have the highest attenuation and hence contribute lowest transmission in the shielded region. Depending upon the shielding angle and thickness, it is possible to predict the dose distribution using the MCNP4B code. In order to deliver the higher dose to the unshielded region, lead may be considered as the shielding material and further it is highly economic over other materials.


Assuntos
Método de Monte Carlo , Proteção Radiológica/métodos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Vaginais/radioterapia , Feminino , Humanos , Proteção Radiológica/economia , Proteção Radiológica/instrumentação , Reto/lesões , Reto/efeitos da radiação , Valores de Referência , Eficiência Biológica Relativa , Medição de Risco , Fatores de Risco , Bexiga Urinária/lesões , Bexiga Urinária/efeitos da radiação , Vagina/lesões , Vagina/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...