Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Phys Eng Express ; 5(2): 025006, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31057946

RESUMO

Autosegmentation of image guidance (IG) scans is crucial for streamlining and optimising delivered dose calculation in radiotherapy. By accounting for interfraction motion, daily delivered dose can be accumulated and incorporated into automated systems for adaptive radiotherapy. Autosegmentation of IG scans is challenging due to poorer image quality than typical planning kilovoltage computed tomography (kVCT) systems, and the resulting reduction of soft tissue contrast in regions such as the pelvis makes organ boundaries less distinguishable. Current autosegmentation solutions generally involve propagation of planning contours to the IG scan by deformable image registration (DIR). Here, we present a novel approach for primary autosegmentation of the rectum on megavoltage IG scans acquired during prostate radiotherapy, based on the Chan-Vese algorithm. Pre-processing steps such as Hounsfield unit/intensity scaling, identifying search regions, dealing with air, and handling the prostate, are detailed. Post-processing features include identification of implausible contours (nominally those affected by muscle or air), 3D self-checking, smoothing, and interpolation. In cases where the algorithm struggles, the best estimate on a given slice may revert to the propagated kVCT rectal contour. Algorithm parameters were optimised systematically for a training cohort of 26 scans, and tested on a validation cohort of 30 scans, from 10 patients. Manual intervention was not required. Comparing Chan-Vese autocontours with contours manually segmented by an experienced clinical oncologist achieved a mean Dice Similarity Coefficient of 0.78 (SE < 0.011). This was comparable with DIR methods for kVCT and CBCT published in the literature. The autosegmentation system was developed within the VoxTox Research Programme for accumulation of delivered dose to the rectum in prostate radiotherapy, but may have applicability to further anatomical sites and imaging modalities.

2.
R Soc Open Sci ; 5(3): 172334, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29657819

RESUMO

Field crickets are extensively used as a model organism to study female phonotactic walking behaviour, i.e. their attraction to the male calling song. Laboratory-based phonotaxis experiments generally rely on arena or trackball-based settings; however, no attention has been paid to the effect of substrate texture on the response. Here, we tested phonotaxis in female Gryllus bimaculatus, walking on trackballs machined from methyl-methacrylate foam with different cell sizes. Surface height variations of the trackballs, due to the cellular composition of the material, were measured with profilometry and characterized as smooth, medium or rough, with roughness amplitudes of 7.3, 16 and 180 µm. Female phonotaxis was best on a rough and medium trackball surface, a smooth surface resulted in a significant lower phonotactic response. Claws of the cricket foot were crucial for effective walking. Females insert their claws into the surface pores to allow mechanical interlocking with the substrate texture and a high degree of attachment, which cannot be established on smooth surfaces. These findings provide insight to the biomechanical basis of insect walking and may inform behavioural studies that the surface texture on which walking insects are tested is crucial for the resulting behavioural response.

3.
Phys Med Biol ; 62(15): 6062-6073, 2017 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-28573978

RESUMO

To determine delivered dose to the spinal cord, a technique has been developed to propagate manual contours from kilovoltage computed-tomography (kVCT) scans for treatment planning to megavoltage computed-tomography (MVCT) guidance scans. The technique uses the Elastix software to perform intensity-based deformable image registration of each kVCT scan to the associated MVCT scans. The registration transform is then applied to contours of the spinal cord drawn manually on the kVCT scan, to obtain contour positions on the MVCT scans. Different registration strategies have been investigated, with performance evaluated by comparing the resulting auto-contours with manual contours, drawn by oncologists. The comparison metrics include the conformity index (CI), and the distance between centres (DBC). With optimised registration, auto-contours generally agree well with manual contours. Considering all 30 MVCT scans for each of three patients, the median CI is [Formula: see text], and the median DBC is ([Formula: see text]) mm. An intra-observer comparison for the same scans gives a median CI of [Formula: see text] and a DBC of ([Formula: see text]) mm. Good levels of conformity are also obtained when auto-contours are compared with manual contours from one observer for a single MVCT scan for each of 30 patients, and when they are compared with manual contours from six observers for two MVCT scans for each of three patients. Using the auto-contours to estimate organ position at treatment time, a preliminary study of 33 patients who underwent radiotherapy for head-and-neck cancers indicates good agreement between planned and delivered dose to the spinal cord.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Processamento de Imagem Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Medula Espinal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Automação , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Variações Dependentes do Observador
4.
Radiother Oncol ; 123(3): 466-471, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28460825

RESUMO

BACKGROUND AND PURPOSE: For the first time, delivered dose to the rectum has been calculated and accumulated throughout the course of prostate radiotherapy using megavoltage computed tomography (MVCT) image guidance scans. Dosimetric parameters were linked with toxicity to test the hypothesis that delivered dose is a stronger predictor of toxicity than planned dose. MATERIAL AND METHODS: Dose-surface maps (DSMs) of the rectal wall were automatically generated from daily MVCT scans for 109 patients within the VoxTox research programme. Accumulated-DSMs, representing total delivered dose, and planned-DSMs, from planning CT data, were parametrised using Equivalent Uniform Dose (EUD) and 'DSM dose-width', the lateral dimension of an ellipse fitted to a discrete isodose cluster. Associations with 6 toxicity endpoints were assessed using receiver operator characteristic curve analysis. RESULTS: For rectal bleeding, the area under the curve (AUC) was greater for accumulated dose than planned dose for DSM dose-widths up to 70Gy. Accumulated 65Gy DSM dose-width produced the strongest spatial correlation (AUC 0.664), while accumulated EUD generated the largest AUC overall (0.682). For proctitis, accumulated EUD was the only reportable predictor (AUC 0.673). Accumulated EUD was systematically lower than planned EUD. CONCLUSIONS: Dosimetric parameters extracted from accumulated DSMs have demonstrated stronger correlations with rectal bleeding and proctitis, than planned DSMs.


Assuntos
Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Reto/efeitos da radiação , Idoso , Hemorragia Gastrointestinal/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica
5.
J Biomech ; 42(11): 1650-5, 2009 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-19464014

RESUMO

Eleven carotid atherothrombotic plaque samples were harvested from patients. Three samples that were highly calcified were discarded, while eight yielded results. The elastic properties of the material were estimated by fitting the measured indentation response to finite element simulations. The methodology was refined and its accuracy quantified using a synthetic rubber. The neo-Hookean form of the material model gave a good fit to the measured response of the tissue. The inferred shear modulus mu was found to be in the range 7-100 kPa, with a median value of 11 kPa. A review of published materials data showed a wide range of material properties for human atherothrombotic tissue. The effects of anisotropy and time dependency in these published results were highlighted. The present measurements were comparable to the static radial compression tests of Lee et al, 1991 [Structure-dependent dynamic behaviour of fibrous caps from human atherosclerotic plaques. Circulation 83, 1764-1770].


Assuntos
Artérias Carótidas/fisiopatologia , Trombose/fisiopatologia , Anisotropia , Fenômenos Biomecânicos , Artérias Carótidas/patologia , Força Compressiva , Elasticidade , Análise de Elementos Finitos , Humanos , Pressão , Estresse Mecânico , Resistência à Tração , Fatores de Tempo , Suporte de Carga
6.
Vet Comp Orthop Traumatol ; 21(5): 391-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19011701

RESUMO

Six different double loop configurations which could be applied to the lateral fabella suture (LFS) technique were subjected to in vitro mechanical testing. Three double loop, single strand and three double loop, double strand configurations were tested. The strongest configuration, with a significantly higher mean ultimate load and load at yield, was the interlocking loop configuration. This is a novel configuration which has not previously been reported. The three double loop, single strand configurations all had higher mean ultimate loads than the double loop, double strand configurations. The double strand group with uneven loop length performed very poorly, with significantly lower mean stiffness and ultimate load than all of the single strand groups. This group also developed unacceptably high levels of elongation during high level cyclic loading.


Assuntos
Lesões do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Técnicas de Sutura/veterinária , Resistência à Tração , Análise de Variância , Animais , Ligamento Cruzado Anterior/fisiopatologia , Cadáver , Cães , Estresse Mecânico , Técnicas de Sutura/normas , Falha de Tratamento , Suporte de Carga/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...