Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Drug Deliv Rev ; 204: 115157, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38104896

RESUMO

Over the last decades, ionic liquids (IL) have shown great potential in non-invasive delivery starting from synthetic small molecules to biological large molecules. ILs are emerging as a particular class of drug delivery systems due to their unique physiochemical properties, simple surface modification, and functionalization. These features of IL help achieve specific design principles that are essential for a non-invasive drug delivery system. In this review, we have discussed IL and their applications in non-invasive drug delivery systems. We evaluated state-of-the-art development and advances of IL aiming to mitigate the biological and physical barriers to improve transdermal and oral delivery, summarized in this review. We also provided an overview of the various factors determining the systemic transportation of IL-based formulation. Additionally, we have emphasized how the ILs facilitate the transportation of therapeutic molecules by overcoming biological barriers.


Assuntos
Líquidos Iônicos , Humanos , Líquidos Iônicos/química , Sistemas de Liberação de Medicamentos , Administração Cutânea
2.
Biosensors (Basel) ; 12(9)2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36140116

RESUMO

After the COVID-19 pandemic, the development of an accurate diagnosis and monitoring of diseases became a more important issue. In order to fabricate high-performance and sensitive biosensors, many researchers and scientists have used many kinds of nanomaterials such as metal nanoparticles (NPs), metal oxide NPs, quantum dots (QDs), and carbon nanomaterials including graphene and carbon nanotubes (CNTs). Among them, CNTs have been considered important biosensing channel candidates due to their excellent physical properties such as high electrical conductivity, strong mechanical properties, plasmonic properties, and so on. Thus, in this review, CNT-based biosensing systems are introduced and various sensing approaches such as electrochemical, optical, and electrical methods are reported. Moreover, such biosensing platforms showed excellent sensitivity and high selectivity against not only viruses but also virus DNA structures. So, based on the amazing potential of CNTs-based biosensing systems, healthcare and public health can be significantly improved.


Assuntos
Técnicas Biossensoriais , COVID-19 , Grafite , Nanoestruturas , Nanotubos de Carbono , Técnicas Biossensoriais/métodos , COVID-19/diagnóstico , DNA Viral , Humanos , Nanoestruturas/química , Nanotubos de Carbono/química , Óxidos , Pandemias
3.
Membranes (Basel) ; 11(3)2021 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-33673539

RESUMO

Improved proton conductivity and high durability are now a high concern for proton exchange membranes (PEMs). Therefore, highly proton conductive PEMs have been synthesized from branched sulfonimide-based poly(phenylenebenzophenone) (SI-branched PPBP) with excellent thermal and chemical stability. The branched polyphenylene-based carbon-carbon backbones of the SI-branched PPBP membranes were attained from the 1,4-dichloro-2,5-diphenylenebenzophenone (PBP) monomer using 1,3,5-trichlorobenzene as a branching agent (0.1%) via the Ni-Zn catalyzed C-C coupling reaction. The as-synthesized SI-branched PPBP membranes showed 1.00~1.86 meq./g ion exchange capacity (IEC) with unique dimensional stability. The sulfonimide groups of the SI-branched PPBP membranes had improved proton conductivity (75.9-121.88 mS/cm) compared to Nafion 117 (84.74 mS/cm). Oxidation stability by thermogravimetric analysis (TGA) and Fenton's test study confirmed the significant properties of the SI-branched PPBP membranes. Additionally, a very distinct microphase separation between the hydrophobic and hydrophilic moieties was observed using atomic force microscopic (AFM) analysis. The properties of the synthesized SI-branched PPBP membranes demonstrate their viability as an alternative PEM material.

4.
Membranes (Basel) ; 11(1)2021 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-33445796

RESUMO

Polymer membranes, having improved conductivity with enhanced thermal and chemical stability, are desirable for proton exchange membranes fuel cell application. Hence, poly(benzophenone)s membranes (SI-PBP) containing super gas-phase acidic sulfonyl imide groups have been prepared from 2,5-dichlorobenzophenone (DCBP) monomer by C-C coupling polymerization using Ni (0) catalyst. The entirely aromatic C-C coupled polymer backbones of the SI-PBP membranes provide exceptional dimensional stability with rational ion exchange capacity (IEC) from 1.85 to 2.30 mS/cm. The as-synthesized SI-PBP membranes provide enhanced proton conductivity (107.07 mS/cm) compared to Nafion 211® (104.5 mS/cm). The notable thermal and chemical stability of the SI-PBP membranes have been assessed by the thermogravimetric analysis (TGA) and Fenton's test, respectively. The well distinct surface morphology of the SI-PBP membranes has been confirmed by the atomic force microscopy (AFM). These results of SI-PBP membranes comply with all the requirements for fuel cell applications.

5.
Biosens Bioelectron ; 126: 381-388, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30469076

RESUMO

This research demonstrated the electrochemical modification of low-cost titanium (Ti) metal substrate with gold nanoparticles (AuNPs) for the aptamer-based detection of cardiac troponin I (cTnI). AuNPs were deposited onto Ti sheets by the potential-step deposition method with high density and homogeneity as well as good crystallinity. It was then applied as a transducer to immobilize a thiol-functionalized DNA aptamer via the self-assembled monolayer mechanism for the specific binding of cTnI. This was verified through electrochemical and morphological analyses. The aptasensor could detect cTnI in a linear range of 1-1100 pM with a detection limit of ca. 0.18 pM. The aptasensor showed high sensitivity and specificity to cTnI over other interfering compounds with good recoveries in the diluted human serum samples.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Troponina I/isolamento & purificação , Aptâmeros de Nucleotídeos/química , Ouro/química , Grafite/química , Humanos , Limite de Detecção , Nanopartículas Metálicas/química , Troponina I/sangue , Troponina I/química
6.
Mikrochim Acta ; 185(1): 23, 2017 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-29594658

RESUMO

2,4-Dinitrophenylhydrazine (DNPH) was electropolymerized on the surface of an anodized glassy carbon electrode by cyclic voltammetry. The anodized electrode has a highly electroactive surface due to the creation of chemically functionalized graphitic nanoparticles, and this facilitates the formation of poly-DNPH via radical polymerization. Poly-DNPH displays excellent redox activity due to the presence of nitro groups on its backbone. These catalyze the electro-oxidation of hydroquinone (HQ) and catechol (CT). The peak-to-peak separation is around 109 mV, while a bare GCE cannot resolve the peaks (located at 165 and 274 mV vs. Ag/AgCl). Sensitivity is also enhanced to ∼1.20 and 1.19 µA·cm-2·µM-1, respectively. The sensor has a linear response that covers the 20-250 µM concentration range for both HQ and CT, with 0.75 and 0.76 µM detection limits, respectively, at simultaneous detection. Commonly present species do not interfere. Graphical abstract A novel conducting poly(2,4-dinitrophenylhydrazine)-modified anodized glassy carbon electrode (pDNPH/AGCE) was developed by electrochemical method. The electro-catalytic activity of pDNPH/AGCE sensor was investigated for the selective and simultaneous electrochemical detection of hydroquinone (HQ) and catechol (CT), which revealed high sensitivities and low detection limits with excellent stability.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...