1.
Sci Rep ; 10(1): 9405, 2020 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-32523085

RESUMO

This study investigates the x-ray scattering characteristics of microsphere particles in x-ray-grating-based interferometric imaging at different concentrations, bubble sizes and tube voltages (kV). Attenuation (ATI), dark-field (DFI) and phase-contrast (PCI) images were acquired. Signal-to-noise (SNR) and contrast-to-noise ratios with water (CNRw) and air as reference (CNRa) were determined. In all modalities, a linear relationship between SNR and microbubbles concentration, respectively, microsphere size was found. A significant gain of SNR was found when varying kV. SNR was significantly higher in DFI and PCI than ATI. The highest gain of SNR was shown at 60 kV for all media in ATI and DFI, at 80 kV for PCI. SNR for all media was significantly higher compared to air and was slightly lower compared to water. A linear relationship was found between CNRa, CNRw, concentration and size. With increasing concentration and decreasing size, CNRa and CNRw increased in DFI, but decreased in PCI. Best CNRa and CNRw was found at specific combination of kV and concentration/size. Highest average CNRa and CNRw was found for microspheres in ATI and PCI, for microbubbles in DFI. Microspheres are a promising contrast-media for grating-based-interferometry, if kV, microsphere size and concentration are appropriately combined.


Assuntos
Meios de Contraste/química , Radiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Microbolhas , Doses de Radiação , Raios X
2.
Phys Med Biol ; 64(6): 065013, 2019 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-30731447

RESUMO

X-ray dark-field imaging is a promising technique for lung diagnosis. Due to the alveolar structure of lung tissue, a higher contrast is obtained by the dark-field image compared to the attenuation image. Animal studies indicate an enhancement regarding the detection of lung diseases in early stages. In this publication, we focus on the influence of different Talbot-Lau interferometer specifications while maintaining the x-ray source, sample magnification and detector system. By imaging the same porcine lung with three different grating sets, we analyze the contrast-to-noise ratio of the obtained dark-field images with respect to visibility and correlation length. We demonstrate that relatively large grating periods of the phase and of the analyzer grating are sufficient for high quality lung imaging at reasonable dose levels.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Interferometria/métodos , Pulmão/diagnóstico por imagem , Animais , Interferometria/instrumentação , Suínos , Raios X
3.
Phys Med Biol ; 63(18): 185010, 2018 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-30117437

RESUMO

Talbot-Lau x-ray imaging provides additionally to the conventional attenuation image, two further images: the differential phase-contrast image which is especially sensitive to differences in refractive properties and the dark-field image which is showing the x-ray scattering properties of the object. Thus, in the dark-field image sub-pixeled object information can be observed. As it has been shown in recent studies, this is of special interest for lung imaging. Changes in the alveoli structure, which are in the size of one detector pixel, can be seen in the dark-field images. A fast acquisition process is crucial to avoid motion artifacts due to heartbeat and breathing of the patient. Using moiré imaging the images can be acquired with a single-shot exposure. Nevertheless, the spatial resolution is reduced compared to the phase-stepping acquisition. We evaluate the results of both imaging techniques towards their feasibility in clinical routine. Furthermore, we analyse the influence of artificial linear object movement on the image quality, in order to simulate the heartbeat of a patient.


Assuntos
Interferometria/métodos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia/métodos , Animais , Interferometria/instrumentação , Movimento , Radiografia/instrumentação , Suínos , Raios X
4.
Phys Med Biol ; 63(13): 135018, 2018 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-29968576

RESUMO

Talbot-Lau x-ray imaging (TLXI) is an innovative and promising imaging technique providing information about the x-ray attenuation, scattering, and refraction features of objects. However, the method is susceptible to vibrations and system component imprecisions, which are inevitable in clinical and industrial practice. Those influences provoke grating displacements and hence errors in the acquired raw data, which cause moiré artifacts in the reconstructed images. We developed an enhanced reconstruction algorithm capable of compensating these errors by adjusting the grating positions and thus suppressing the occurrence of moiré artifacts. The algorithm has been developed with regard to a future application in medical practice. The capability of the algorithm is demonstrated on a medical data set of a human hand (post-mortem) acquired under clinical conditions using a pre-clinical TXLI prototype. It is shown that the algorithm reliably suppresses moiré artifacts, preserves image contrast, does not blur anatomical structures or prevent quantitative imaging, and is executable on low-dose data sets. In addition, the algorithm runs autonomously without the need of interaction or rework of the final results. In conclusion, the proposed reconstruction algorithm facilitates the use of TLXI in clinical practice and allows the exploitation of the method's full diagnostic potential in future medical applications.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Humanos , Processamento de Imagem Assistida por Computador/normas , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...