Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Braz Dent J ; 35: 5746, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39045986

RESUMO

This study aimed to evaluate the bond strength between relined fiberglass posts with different composite resin opacities in different thirds of the intraradicular dentin. Thirty single-rooted premolars were endodontically treated and divided into three groups (n=10): fiberglass posts relined with translucent composite resin, fiberglass posts relined with opaque composite resin, and fiberglass posts without relining. After cementation of the posts, the specimens were cut perpendicular to the long axis of the tooth in slices of approximately 1.3 mm of each third to be analyzed (cervical, middle, and apical) and then subjected to the push-out test. The bond strength (MPa) data were subjected to Shapiro-Wilk normality tests and two-way repeated measures analysis of variance, considering the experimental groups and different regions as study factors. Tukey's post-hoc test (p<.05) was applied for comparisons between the groups. In the cervical third, higher values of bond strength were found for the group relined with translucent resin, with a statistically significant difference for the other groups. In the other regions, both opaque and translucent resins showed similar results, but both showed higher values of bond strength compared to fiberglass posts without relining. The bond strength of fiberglass posts to different thirds of intraradicular dentin is influenced by composite resin relining as well as the opacity of the resin. The use of translucent composite resin is a more effective alternative for fiberglass posts relining.


Assuntos
Resinas Compostas , Colagem Dentária , Dentina , Vidro , Técnica para Retentor Intrarradicular , Humanos , Resinas Compostas/química , Colagem Dentária/métodos , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície , Materiais Dentários/química , Dente não Vital
2.
Biofouling ; 40(2): 99-113, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38425046

RESUMO

This scoping review focused on exploring the efficacy of flavonoids against bacteria associated with dental caries and periodontal diseases. Inclusion criteria comprise studies investigating the antibacterial effects of flavonoids against bacteria linked to caries or periodontal diseases, both pure or diluted in vehicle forms. The search, conducted in August 2023, in databases including PubMed/MEDLINE, Scopus, Web of Science, Embase, LILACS, and Gray Literature. Out of the initial 1125 studies, 79 met the inclusion criteria, majority in vitro studies. Prominent flavonoids tested included epigallocatechin-gallate, apigenin, quercetin, and myricetin. Predominant findings consistently pointed to bacteriostatic, bactericidal, and antibiofilm activities. The study primarily investigated bacteria associated with dental caries, followed by periodontopathogens. A higher number of publications presented positive antibacterial results against Streptococcus mutans in comparison to Porphyromonas gingivalis. These encouraging findings underline the potential applicability of commercially available flavonoids in materials or therapies, underscoring the need for further exploration in this field.


Assuntos
Cárie Dentária , Doenças Periodontais , Humanos , Cárie Dentária/prevenção & controle , Biofilmes , Doenças Periodontais/tratamento farmacológico , Doenças Periodontais/microbiologia , Porphyromonas gingivalis , Flavonoides/farmacologia , Antibacterianos/farmacologia , Streptococcus mutans
3.
Braz Oral Res ; 37: e092, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38055513

RESUMO

This study aimed to evaluate surface roughness (Sa), roughness profile (Rv), and enamel wear after brushing with different whitening toothpastes and charcoal powders. Sixty (n = 10) bovine enamel blocks (6 × 6 × 3 mm) were randomly distributed into six groups according to toothpaste type: regular toothpaste (CONT), toothpaste containing 2% hydrogen peroxide (HP), toothpaste containing titanium dioxide (TiO2), toothpaste containing charcoal (COAL), toothpaste containing charcoal and TiO2 (COAL+TiO2), and activated charcoal powder (COAL_PWD). Each block was subjected to 30,000 reciprocal cycles at a 1:3 proportion slurry. After brushing, the blocks were analyzed using an optical profilometer to determine Sa, Rv, and enamel wear. In addition, representative 3D images of each group and wear profiles were obtained. Sa was analyzed using generalized linear models followed by Bonferroni correction, whereas Rv was analyzed using one-way analysis of variance. After brushing, COAL and COAL+TiO2 showed higher Sa values than COAL_PWD. However, no significant difference was observed in Sa between whitening toothpaste and COAL_PWD, and CONT (p > 0.05). In addition, no differences were observed among the groups in Rv (p > 0.05). Conversely, enamel wear was higher for TiO2, COAL, COAL+TiO2, and COAL_PWD than for CONT. CONT showed the least enamel wear, whereas HP showed intermediate values. Representative 3D images and line profiles showed lower step-height and lower mean surface losses for the CONT and HP groups than for the other groups. Whitening toothpastes and COAL_PWD did not increase Sa or Rv compared with CONT, while CONT demonstrated lower enamel wear.


Assuntos
Carvão Vegetal , Cremes Dentais , Animais , Bovinos , Carvão Vegetal/farmacologia , Esmalte Dentário , Peróxido de Hidrogênio , Pós/farmacologia , Escovação Dentária
4.
Braz. oral res. (Online) ; 37: e092, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1520518

RESUMO

Abstract This study aimed to evaluate surface roughness (Sa), roughness profile (Rv), and enamel wear after brushing with different whitening toothpastes and charcoal powders. Sixty (n = 10) bovine enamel blocks (6 × 6 × 3 mm) were randomly distributed into six groups according to toothpaste type: regular toothpaste (CONT), toothpaste containing 2% hydrogen peroxide (HP), toothpaste containing titanium dioxide (TiO2), toothpaste containing charcoal (COAL), toothpaste containing charcoal and TiO2 (COAL+TiO2), and activated charcoal powder (COAL_PWD). Each block was subjected to 30,000 reciprocal cycles at a 1:3 proportion slurry. After brushing, the blocks were analyzed using an optical profilometer to determine Sa, Rv, and enamel wear. In addition, representative 3D images of each group and wear profiles were obtained. Sa was analyzed using generalized linear models followed by Bonferroni correction, whereas Rv was analyzed using one-way analysis of variance. After brushing, COAL and COAL+TiO2 showed higher Sa values than COAL_PWD. However, no significant difference was observed in Sa between whitening toothpaste and COAL_PWD, and CONT (p > 0.05). In addition, no differences were observed among the groups in Rv (p > 0.05). Conversely, enamel wear was higher for TiO2, COAL, COAL+TiO2, and COAL_PWD than for CONT. CONT showed the least enamel wear, whereas HP showed intermediate values. Representative 3D images and line profiles showed lower step-height and lower mean surface losses for the CONT and HP groups than for the other groups. Whitening toothpastes and COAL_PWD did not increase Sa or Rv compared with CONT, while CONT demonstrated lower enamel wear.

5.
Gerontology ; 68(1): 80-85, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33853063

RESUMO

Elderly patients with systemic disorders and immunocompromised patients seem to have a higher risk of developing morbidity from COVID-19. Candida albicans (C. albicans) is a potentially dangerous pathogen for these patients, especially for denture wearers with prosthetic stomatitis who require mechanical ventilation. C. albicans infection, the main candidiasis infection associated with denture wear, can complicate COVID-19 and increase the associated morbidity and mortality. Therefore, early diagnosis of C. albicans infection in COVID-19 patients is important to establish more effective antifungal treatment methods and prophylaxis strategies. Hospitalized COVID-19 patients should undergo an oral examination to assess their oral health, and those with poor oral health should receive the appropriate care and monitoring.


Assuntos
COVID-19 , Candidíase Bucal , Estomatite sob Prótese , Idoso , Candidíase Bucal/diagnóstico , Candidíase Bucal/etiologia , Dentaduras , Humanos , SARS-CoV-2
6.
J Mech Behav Biomed Mater ; 123: 104762, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34371332

RESUMO

PURPOSE: Studies evaluating different features of cold plasma action on dentin surface characteristics are lacking. Thus, this in vitro study aimed to determine the effect of cold plasma under different protocols of exposure time, distance to plasma source, and the association of argon gas with distinct concentrations of oxygen on the wettability, surface energy, total free interaction energy, surface roughness, morphology and chemical composition of dentin. MATERIAL AND METHODS: One hundred and twenty-five bovine dentin samples were used and divided into twenty-five groups according to the exposure time to plasma (15, 30, or 60 s); distance between plasma source and dentin surface (3 or 6 mm); argon gas without plasma generation; and plasma generated by argon gas and association of argon gas with distinct concentrations of oxygen (2 % or 3 %) (n = 5). Contact angle (θ), surface energy (γs) and total free interaction energy (ΔG) were measured using a goniometer (Krüss), while surface roughness (Ra) was evaluated by a profilometer (Mitutoyo). Representative samples were submitted to scanning electron microscopy (JEOL) to ilustrate the morphology and chemical composition of dentin. Data comparing control group with all experimental groups were submitted to ANOVA followed by Tukey's test (α = .05). Data comparing oxygen gas action at different concentrations and argon gas on dentin characteristics were submitted to non-parametric Kruskal-Wallis test, followed by Dunn test for comparison between the groups and methods (α = 0.05). RESULTS: In general, argon gas without plasma generation promoted no significant difference on dentin surface characteristics compared to control group (P > .05), differently for the cold plasma that significantly reduced contact angle values and increased total free interaction energy of dentin surface (P < .05). Overall, feeding of oxygen at distinct concentrations promoted significant difference on dentin surface characteristics compared to control group (P < .05). Exposure time and distance protocols interfered with contact angle, surface energy and total free interaction energy analyses for each gas. There was no significant difference on surface roughness (P > .05), morphology and chemical composition of dentin submitted to argon gas, cold plasma, and distinct concentrations of oxygen. CONCLUSION: In conclusion, plasma generated by argon gas and its feeding with 2 % and 3 % oxygen gas improved the dentin surface characteristics about wettability, surface energy and total free interaction energy. Such treatments preserved the surface roughness, morphology and chemical composition of dentin. The protocols of groups Ar-6mm-15sec, ArO2-3mm-30sec and ArO3-3mm-15sec are recommended for improvement of dentin surface characteristics.


Assuntos
Gases em Plasma , Animais , Argônio , Bovinos , Dentina , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Molhabilidade
7.
Oral Health Prev Dent ; 18(1): 145-152, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32238986

RESUMO

PURPOSE: To evaluate the microtensile bond strength of dentine/self-adhesive resin cement interface after several treatments on a dentine surface. MATERIALS AND METHODS: Twenty-eight human molars were selected and divided into four groups: no treatment (control (C)); 2% chlorhexidine digluconate (CHX); 25% polyacrylic acid (PA); and 23 ppm dispersive solution of silver nanoparticle (SN). Prepolymerised TPH resin composite (Dentsply) blocks were luted on the dentine surface using RelyX U200 self-adhesive resin cement (3M ESPE). Microtensile bond strength was measured (MPa) in a universal testing machine 24 h and 6 months after the bonding process. The fractured specimens were examined in an optical microscope and classified according to the fracture pattern. A representative sample of each group was observed by scanning electronic microscope. Data were submitted to analysis of variance (ANOVA) and Tukey's test to compare the mean among the groups (p <0.05). RESULTS: The highest microtensile bond strength values after 24 h were found for the PA group (13.34 ± 6.36 MPa), with no statistically significant difference for the C group (9.76 ± 3.11 Mpa). After 6 months, the highest microtensile bond strength values were found for the C group (9.09 ± 3.27 Mpa), with statistically significant difference only for the CHX group (2.94 ± 1.66 MPa). There was statistically significant difference only for the PA group when comparing the periods studied. Regardless of the surface treatment applied, there were more adhesive failures in both periods of time. CONCLUSION: Dentinal pretreatment with PA, as well as use of SN before the bonding procedure of self-adhesive resin cement to dentine, may be alternative bonding protocols.


Assuntos
Colagem Dentária , Nanopartículas Metálicas , Resinas Compostas , Cimentos Dentários , Análise do Estresse Dentário , Dentina , Adesivos Dentinários , Humanos , Teste de Materiais , Cimentos de Resina , Prata , Propriedades de Superfície , Resistência à Tração
8.
Restor Dent Endod ; 45(1): e12, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32110540

RESUMO

OBJECTIVES: The aim of this in vitro study was to evaluate the microhardness and surface roughness of composite resins before and after tooth bleaching procedures. MATERIALS AND METHODS: Sixty specimens were prepared of each composite resin (Filtek Supreme XT and Opallis), and BisCover LV surface sealant was applied to half of the specimens. Thirty enamel samples were obtained from the buccal and lingual surfaces of human molars for use as the control group. The surface roughness and microhardness were measured before and after bleaching procedures with 35% hydrogen peroxide or 16% carbamide (n = 10). Data were analyzed using 1-way analysis of variance and the Fisher test (α = 0.05). RESULTS: Neither hydrogen peroxide nor carbamide peroxide treatment significantly altered the hardness of the composite resins, regardless of surface sealant application; however, both treatments significantly decreased the hardness of the tooth samples (p < 0.05). The bleaching did not cause any change in surface roughness, with the exception of the unsealed Opallis composite resin and dental enamel, both of which displayed an increase in surface roughness after bleaching with carbamide peroxide (p < 0.05). CONCLUSIONS: The microhardness and surface roughness of enamel and Opallis composite resin were influenced by bleaching procedures.

9.
Oral Health Prev Dent ; 18(1): 71-76, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32051973

RESUMO

PURPOSE: The aim of this in vitro study was to evaluate the influence of preapplication of 2% chlorhexidine gluconate on the immediate microtensile bond strength of a universal adhesive system on dentine subjected to different bonding protocols. MATERIALS AND METHODS: Twenty human molars were used in this study, and the tooth surface was abraded to expose the dentine. The teeth were randomly divided into four groups according to the surface treatment (n = 5): SBU group: Single Bond Universal without acid etching; SBUPA group: 37% phosphoric acid + Single Bond Universal; SBUCG group: 2% chlorhexidine gluconate + Single Bond Universal; and SBUPACG group: 37% phosphoric acid + 2% chlorhexidine gluconate + Single Bond Universal. The microtensile bond strengths were measured using a microtensile tester 24 h after bonding. The bond strength data were subjected to analysis of variance (ANOVA) and Sheffé's least statistically significant difference test (α = 0.05). RESULTS: No statistically significant differences between the analysed groups were observed (p > 0.05). However, conditioning with phosphoric acid without the action of the chlorhexidine gluconate group resulted in higher numerical values of bond strengths than that for the chlorhexidine gluconate without the acid conditioning group. CONCLUSION: The preapplication of 2% chlorhexidine gluconate did not reduce the immediate bond strength of the Single Bond Universal adhesive system under different bonding protocols.


Assuntos
Colagem Dentária , Adesivos Dentinários , Condicionamento Ácido do Dente , Clorexidina/análogos & derivados , Resinas Compostas , Cimentos Dentários , Dentina , Humanos , Teste de Materiais , Projetos Piloto , Propriedades de Superfície , Resistência à Tração
10.
Gen Dent ; 68(1): 72-77, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31859667

RESUMO

This study evaluated the Martens hardness (HM) and elastic modulus (EIT) of resin cement and dentin underlying the bonding interface of customized glass fiber posts luted to intraradicular dentin and subjected to mechanical cycling. Two null hypotheses were tested: (1) no differences in the mechanical properties (HM and EIT) of the resin cement and underlying dentin would be found between customized and noncustomized glass fiber post groups, with or without mechanical cycling; and (2) no differences in the mechanical properties of the resin cement or underlying dentin would be found between the cervical, middle, and apical thirds of the intraradicular dentin. Forty single-rooted premolars were divided into 4 groups: customized or noncustomized glass fiber post, with or without mechanical cycling. The noncustomized posts were cemented in their original state to prepared canals, while the customized posts were modified with composite resin according to the geometry of the root canal. The specimens in the mechanical cycling groups were positioned at a 45-degree angle in an electromechanical fatigue testing machine and subjected to loading with a steel tip with a 4-mm diameter for 1,200,000 cycles at 50 N. After the specimens were prepared according to the appropriate group protocol, they were sectioned into thirds, and HM and EIT values of the resin cement and dentin underlying the bonding interface were determined using an ultramicrohardness tester under a load of 5 mN. A 2-way repeated-measures analysis of variance with post hoc Tukey test was performed. For resin cement in the cervical region, the highest HM and EIT values were observed in the noncustomized group after mechanical cycling. Similarly, in the underlying dentin, specimens in the noncustomized group after mechanical cycling had the highest HM values in the cervical region. Therefore, customization of glass fiber posts with composite resin is not essential for bonding to intraradicular dentin.


Assuntos
Colagem Dentária , Vidro , Técnica para Retentor Intrarradicular , Cimentos de Resina , Resinas Compostas , Materiais Dentários , Cavidade Pulpar , Dentina , Teste de Materiais , Estresse Mecânico
11.
PLoS One ; 14(6): e0217750, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31242198

RESUMO

This study evaluated the influence of silver nanoparticle on mechanical properties of the components of underlying dentin and resin cement in different regions of intraradicular dentin. Ninety extracted single-rooted human teeth were used in this study. After endodontic preparation, the teeth were divided into five groups, according to the irrigating agents: distilled water, 5.25% sodium hypochlorite, 25% polyacrylic acid, 2% chlorhexidine and 23 ppm silver nanoparticles dispersion. Then, the groups were divided in 3 subgroups (n = 6) according to the technique adopted for adhesive cementation: SUA group: Scotchbond Universal Adhesive + RelyX ARC; U200 group: RelyX U200; and MCE group: MaxCem Elite. The mechanical properties of hardness and elastic modulus were measured in resin cement and underlying dentin in ultra-micro hardness tester in different thirds of radicular dentin surface. Data were subjected to ANOVA and Fisher's test (p = 0.05). In the underlying dentin, in general, there was no statistically significant difference in different thirds of intraradicular dentin according to the different solutions used. In the resin cements, higher hardness values were found, in general, for the cervical third. When silver nanoparticle solution was used, higher mechanical properties were generally obtained for resin cement for the SBU and U200 groups, with little or no changes in mechanical properties for the dentin. Silver nanoparticle application is a viable option for irrigation the intraradicular dentin previously through the cementation process of glass fiber posts. The mechanical properties are influenced by irrigant solutions used and the depth intraradical analyzed area.


Assuntos
Dentina/química , Nanopartículas Metálicas/química , Cimentos de Resina/química , Prata/química , Cimentação , Teste de Materiais , Preparo de Canal Radicular , Propriedades de Superfície
12.
J Indian Prosthodont Soc ; 19(2): 197-200, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31040556

RESUMO

This case report aimed to describe the clinical considerations in oral rehabilitation with prostheses on implants in the anterior region, using emergence profile customization technique during implant transfer. A patient presented with a missing left upper central incisor and with not satisfactory esthetic in the other upper incisors. After diagnosis, a treatment plan was elaborated: implant placement in this region; ceramic laminates for teeth 11 and 22, and full crown for tooth 12. During the impression procedure, the implant transfer was customized by copying the gingival profile. The prostheses were made using IPS e.max ceramic system and luted with resin cement. The patient was submitted to annual follow-up examinations that did not show any irregularity or deficiency in the prostheses. The technique performed is a viable alternative that can be used in oral rehabilitation with implants involving anterior teeth because it allows a predictable level of adaptation.

13.
Braz Dent J ; 30(2): 106-116, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30970052

RESUMO

The aim of this study was to evaluate the push-out bond strength and interface permeability of glass-fiber posts in different regions of post space (cervical, middle, and apical) submitted to different irrigation solutions. Ninety single-rooted human teeth were submitted to endodontic treatment and divided into five groups, according to irrigation solutions: distilled water, 5.25% NaOCl, 25% polyacrylic acid, 2% chlorhexidine, and 23 ppm Ag NP dispersion. Each group was divided in 3 subgroups (n=6) according to cementation: SBU: Adper Scotchbond Universal + RelyX ARC; U200: RelyX U200; MCE: MaxCem Elite. Bond strength and sealing ability were measured in different areas of post space. The data was subjected to ANOVA and Fisher's test (a=0,05). The silver nanoparticle solution showed highest bond strength values and lowest interface permeability in all thirds analyzed for SBU group. In the U200 group, the highest bond strength values were found for sodium hypochlorite solution, with significant difference between this solution and polyacrylic acid. A decrease in bond strength values in cervical to apical direction was found for MCE group and the same behavior were found for others groups. Regarding interface permeability, use of silver nanoparticle solution resulted in lower values in cervical and apical thirds. There was a decrease in bond strength in cervical to apical direction. Different irrigation solutions and intraradicular depth influenced the bond strength and interface permeability of adhesive material to dentin substrate. Silver nanoparticle solution can effectively be used as an irrigation agent in post space prior to fiber post cementation process.


Assuntos
Colagem Dentária , Nanopartículas Metálicas , Técnica para Retentor Intrarradicular , Dentina , Vidro , Humanos , Teste de Materiais , Cimentos de Resina , Prata
14.
Braz Oral Res ; 33: e024, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30970089

RESUMO

The aim of this study is to evaluate the effect of chitosan or nanodiamond incorporation on the color stability and surface roughness of a bisacrylic resin subjected to artificial aging. Four bisacrylic resins were evaluated, namely, control, chitosan-modified material, nanodiamond-modified material, and chitosan-nanodiamond-modified material. Twenty-four specimens were prepared for each material. The surface roughness was determined using a profilometer with a cut-off of 0.25 mm. The baseline color was measured according to the CIE L*a*b* system using a reflectance spectrophotometer. After these tests, the specimens were individually immersed in cola soft drink, red wine, or distilled water (n = 8) for 28 days. After the aging, the surface roughness and final color were re-evaluated. The color stability was determined using the difference between the coordinates obtained before and after the aging process. The data on roughness and color change were evaluated using ANOVA and the Tukey test (α = 0.05). The results show that the incorporation of nanodiamonds and chitosan into a bisacrylic resin provided a better color stability to the materials (p = 0.007). The storage in red wine resulted in a higher variation in the surface roughness values, especially when only the nanodiamond was incorporated to the material (p < 0.05). The incorporation of both chitosan and nanodiamonds are promising in providing an improvement in the properties of the bisacrylic resin when they are simultaneously incorporated in the product.


Assuntos
Resinas Acrílicas/química , Quitosana/química , Cor , Resinas Compostas/química , Nanodiamantes/química , Análise de Variância , Bebidas Gaseificadas , Teste de Materiais , Microscopia Eletrônica de Varredura , Valores de Referência , Reprodutibilidade dos Testes , Espectrofotometria , Estatísticas não Paramétricas , Propriedades de Superfície , Fatores de Tempo , Água/química , Vinho
15.
Braz. j. oral sci ; 18: e191451, jan.-dez. 2019. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1087501

RESUMO

Aim The aim of this study is to evaluate the degree of conversion (DC) of resin cements polymerized under different thicknesses of feldspathic dental ceramic. Methods: Forty samples of RelyX ARC and RelyX Veneer resin cements were polymerized under Starlight feldspathic ceramic discs (DeguDent Gmbh) with 0.5 mm, 1.2 mm, 1.8 mm, and 2.4 mm in thickness. The control group was cured without the interposition of ceramic. The DC measurements were performed 10 minutes, 1 hour, and 24 hours after the light-activation in a Nexus 670 FTIR spectrophotometer. Data were analyzed by two-way repeated measure ANOVA and Fisher PLSD test. Results: The RelyX ARC showed higher DC for all ceramic thicknesses. There was significant decrease in DC related to an increase in ceramic thickness. For RelyX ARC, the values of DC obtained after 1 hour and 24 hours did not differ statistically between them, but they were higher than those analyzed after 10 minutes. For RelyX Veneer cement, there was gradual increase in the DC up to 24 hours. Conclusion: The higher the thicknesses of ceramic, the lower DC of the resin cement


Assuntos
Cerâmica , Cimentos de Resina , Polimerização
16.
Eur J Dent ; 12(4): 559-565, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30369803

RESUMO

OBJECTIVE: This study aims to evaluate the effect of acidic solutions (AS) on surface roughness (Ra) and microhardness of restorative materials (RM). MATERIALS AND METHODS: Eight volunteers wore intraoral palatal devices (IPD) containing samples of RM: Ketac Nano (KN); Ketac Nano + Biscover LV (KN-B); Esthet-X (EX); Esthet-X + Biscover LV (EX-B); Supreme XT (SXT); Supreme XT + Biscover LV (SXT-B); and bovine enamel. The samples were submitted to three phases: (1) immersion in 0.01M hydrochloric acid (HCl) - 10 min, three times/day (14 days); (2) immersion in soft drink (Sprite®) - 10 min, three times/day (14 days); and (3) keeping in saliva (14 days). Changes in Ra/microhardness were measured before/after the three phases. STATISTICAL ANALYSIS: ANOVA (α = 0.05) and Fisher's test. RESULTS: Materials sealed with Biscover LV (B) presented lowest values in all periods. KN glass ionomer cement showed highest Ra values after exposure in AS. Application of B did not reduce the Ra for the composites studied, except for EX after immersion in HCl. AS promoted changes in Ra/microhardness of RM, except for sealed materials. CONCLUSIONS: The acids used were able to change the Ra and microhardness of RM, except of the sealed materials. The resin-modified GIC showed the most significant changes after immersion in AS; and the composites sealed with B, even after immersion in acidic solutions (AS), showed the lowest Ra values and the least degradation in microhardness, especially when subjected to low pH solutions.

17.
Braz. j. oral sci ; 17: e18127, 2018. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-963817

RESUMO

Aim: The aim of this study was to verify the microshear bond strength of conventional and self-adhesive resin cements to feldsphatic ceramic. Methods: Twenty discs of Starlight ceramic (Degudent) were made (15mm x 2mm). The bonding procedure was accomplished by insertion of resin cements into tubes of 0.7mm internal diameter in contact with the ceramic. The resin cements used were: RelyX ARC (3M Espe), Panavia F (Kuraray), RelyX Unicem (3M Espe) and seT (SDI). Total of six tubes of each material on each ceramic disc. The specimens were tested for microshear in a universal testing machine, 24hours and 6months after bonding procedure. Values of microshear bonding strength (MPa) were subjected to ANOVA and Fisher PLSD test (p<0.05). Results: For 24hours analysis, RelyX ARC showed the highest microshear bonding strength without statistical difference to RelyX Unicem and seT. Panavia F showed the lowest values of microshear bonding strength in both periods. In the analysis after 6months there was a significant increase in the microshear bonding strength values for all cements compared to 24hours. Only for RelyX ARC, the increase was not statistically significant. Conclusion: In conclusion, the bond strength depends mainly on the type of resin cement used, and the self-adhesive cements behave similarly to conventional resin cement


Assuntos
Cerâmica , Adesivos Dentinários , Cimentos de Resina , Resistência ao Cisalhamento
18.
J Investig Clin Dent ; 8(2)2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-26748677

RESUMO

AIM: In the present study, we evaluated the influence of surface sealing on color stability and surface roughness of a composite resin after accelerated artificial aging. METHODS: Thirty-two specimens of a composite were prepared. After 24 h, the specimens were polished and divided into four groups (n = 8), according to the surface sealant used, including the control, which had no sealant application. Baseline color was measured according to the CIELab system using a reflection spectrophotometer. Surface roughness was determined using a profilometer with a cut-off of 0.25 mm. After these tests, specimens were aged for 252 h in an ultraviolet (UV)-accelerated aging chamber. Color stability was determined by difference between coordinates obtained before and after the aging procedure. Data of color change and roughness were evaluated by anova and Fisher's exact test (α = 0.05). RESULTS: The results showed that the unsealed group had the highest color change compared to other groups (P = 0.0289), and there was no significant difference between groups sealed with surface sealant (P > 0.05). The artificial aging caused an increase in roughness values independent of the experimental group studied (P = 0.0015). CONCLUSION: The sealed composites showed lower color change after UV aging, but all groups showed clinically-acceptable color change, and only liquid polish decreased roughness.


Assuntos
Cor , Resinas Compostas/química , Selantes de Fossas e Fissuras , Resinas Compostas/efeitos da radiação , Teste de Materiais , Selantes de Fossas e Fissuras/efeitos da radiação , Propriedades de Superfície , Raios Ultravioleta
19.
Braz Dent J ; 27(2): 153-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27058377

RESUMO

The aim of the study was to evaluate the effect of erosive pH cycling with solutions that simulate dental erosion on Martens hardness (HMV) and elastic modulus (Eit) of dentin restored with fluoride-releasing adhesive systems. Twenty-seven bovine dentin slabs were restored with three adhesive systems: Adper Single Bond 2 total-etch adhesive system, One Up Bond F and Clearfil SE Protect fluoride-containing self-etching adhesive systems. The restorations were made with Filtek Z250. The HMV and Eit values at distances of 10, 30, 50 and 70 µm from the interface were evaluated using a dynamic ultra microhardness tester before and after immersion in deionized water, citric acid and hydrochloric acid (n=9). Data were submitted to repeated-measures ANOVA and Fisher's PLSD tests (=0.05). After erosive cycling, HMV values of dentin decreased in all groups. For dentin restored with Adper Single Bond 2, the lowest values were found closer to the hybrid layer, while for One Up Bond F and Clearfil SE Protect, the values remained unaltered at all distances. For dentin restored with fluoride-releasing adhesive systems, a decrease in Eit was found, but after 30 µm this difference was not significant. The acid substances were able to alter HMV and Eit of the underlying dentin. For fluoride-releasing adhesives, the greater the distance from bonded interface, the lower the Eit values. The fluoride in One Up Bond F and Clearfil SE Protect was able to protect the underlying dentin closer to the materials. In this way, the fluoride from adhesive systems could have some positive effect in the early stages of erosive lesions.


Assuntos
Adesivos , Dentina/química , Fluoretos/administração & dosagem , Animais , Bovinos , Elasticidade , Testes de Dureza , Concentração de Íons de Hidrogênio
20.
Braz. dent. j ; 27(2): 153-159, Mar.-Apr. 2016. tab
Artigo em Inglês | LILACS | ID: lil-778329

RESUMO

Abstract The aim of the study was to evaluate the effect of erosive pH cycling with solutions that simulate dental erosion on Martens hardness (HMV) and elastic modulus (Eit) of dentin restored with fluoride-releasing adhesive systems. Twenty-seven bovine dentin slabs were restored with three adhesive systems: Adper Single Bond 2 total-etch adhesive system, One Up Bond F and Clearfil SE Protect fluoride-containing self-etching adhesive systems. The restorations were made with Filtek Z250. The HMV and Eit values at distances of 10, 30, 50 and 70 µm from the interface were evaluated using a dynamic ultra microhardness tester before and after immersion in deionized water, citric acid and hydrochloric acid (n=9). Data were submitted to repeated-measures ANOVA and Fisher's PLSD tests (=0.05). After erosive cycling, HMV values of dentin decreased in all groups. For dentin restored with Adper Single Bond 2, the lowest values were found closer to the hybrid layer, while for One Up Bond F and Clearfil SE Protect, the values remained unaltered at all distances. For dentin restored with fluoride-releasing adhesive systems, a decrease in Eit was found, but after 30 µm this difference was not significant. The acid substances were able to alter HMV and Eit of the underlying dentin. For fluoride-releasing adhesives, the greater the distance from bonded interface, the lower the Eit values. The fluoride in One Up Bond F and Clearfil SE Protect was able to protect the underlying dentin closer to the materials. In this way, the fluoride from adhesive systems could have some positive effect in the early stages of erosive lesions.


Resumo O objetivo deste estudo foi avaliar o efeito da ciclagem de pH erosiva com soluções que simulam a erosão dental, na dureza Martens (HMV) e módulo de elasticidade (Eit) da dentina restaurada com sistemas adesivos contendo fluoretos. Vinte e sete blocos de dentina foram restaurados com três sistemas adesivos: sistema adesivo de condicionamento total Adper Single Bond 2 e sistemas adesivos autocondicionantes contendo fluoreto One Up Bond F e Clearfil SE Protect. As restaurações foram realizadas com resina Filtek Z250. Os valores de HMV e Eit nas distâncias de 10, 30, 50 e 70µm da interface foram avaliadas em ultramicrodurômetro dinâmico antes e após a imersão em água deionizada, ácido cítrico e ácido clorídrico (n=9). Dados foram submetidos à ANOVA para medidas repetidas e Fisher PLSD (α=0,05). Após a ciclagem erosiva, os valores de HMV da dentina diminuíram em todos os grupos. Para a dentina restaurada com Adper Single Bond 2, os menores valores foram encontrados próximo a camada híbrida enquanto que, para os sistemas adesivos One Up Bond F e Clearfil SE Protect, os valores permaneceram inalterados em todas as distâncias. Para a dentina restaurada com os materiais que liberam fluoretos, uma redução nos valores de Eit foi encontrada, mas após 30µm essa diferença não foi mais significante. As substâncias ácidas foram capazes de alterar a HMV e o Eit da dentina subjacente. Para os adesivos que liberam fluoretos, quanto maior a distância da interface adesiva, menor os valores de Eit. O fluoreto presente no One Up Bond F e Clearfil SE Protect foi capaz de proteger a dentina subjacente próxima aos materiais. Dessa maneira, a presença do flúor em sistemas adesivos pode ter algum efeito positivo em estágios iniciais de lesões erosivas.


Assuntos
Animais , Bovinos , Adesivos , Dentina/química , Fluoretos/administração & dosagem , Elasticidade , Testes de Dureza , Concentração de Íons de Hidrogênio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...