RESUMO
An alternative to the time-consuming and error-prone pharmacopoeial gas chromatography method for the analysis of fatty acids (FAs) is urgently needed. The objective was therefore to propose a robust liquid chromatography method with charged aerosol detection for the analysis of polysorbate 80 (PS80) and magnesium stearate. FAs with different numbers of carbon atoms in the chain necessitated the use of a gradient method with a Hypersil Gold C18 column and acetonitrile as organic modifier. The risk-based Analytical Quality by Design approach was applied to define the Method Operable Design Region (MODR). Formic acid concentration, initial and final percentages of acetonitrile, gradient elution time, column temperature, and mobile phase flow rate were identified as critical method parameters (CMPs). The initial and final percentages of acetonitrile were fixed while the remaining CMPs were fine-tuned using response surface methodology. Critical method attributes included the baseline separation of adjacent peaks (α-linolenic and myristic acid, and oleic and petroselinic acid) and the retention factor of the last compound eluted, stearic acid. The MODR was calculated by Monte Carlo simulations with a probability equal or greater than 90%. Finally, the column temperature was set at 33 °C, the flow rate was 0.575 mL/min, and acetonitrile linearly increased from 70 to 80% (v/v) within 14.2 min.
RESUMO
Resolving complex sample mixtures by liquid chromatography in a single run is challenging. The so-called mixed-mode liquid chromatography (MMLC) which combines several retention mechanisms within a single column, can provide resource-efficient separation of solutes of diverse nature. The Acclaim Mixed-Mode WCX-1 column, encompassing hydrophobic and weak cation exchange interactions, was employed for the analysis of small drug molecules. The stationary phase's interaction abilities were assessed by analysing molecules of different ionisation potentials. Mixed Quantitative Structure-Retention Relationship (QSRR) models were developed for revealing significant experimental parameters (EPs) and molecular features governing molecular retention. According to the plan of Face-Centred Central Composite Design, EPs (column temperature, acetonitrile content, pH and buffer concentration of aqueous mobile phase) variations were included in QSRR modelling. QSRRs were developed upon the whole data set (global model) and upon discrete parts, related to similarly ionized analytes (local models) by applying gradient boosted trees as a regression tool. Root mean squared errors of prediction for global and local QSRR models for cations, anions and neutrals were respectively 0.131; 0.105; 0.102 and 0.042 with the coefficient of determination 0.947; 0.872; 0.954 and 0.996, indicating satisfactory performances of all models, with slightly better accuracy of local ones. The research showed that influences of EPs were dependant on the molecule's ionisation potential. The molecular descriptors highlighted by models pointed out that electrostatic and hydrophobic interactions and hydrogen bonds participate in the retention process. The molecule's conformation significance was evaluated along with the topological relationship between the interaction centres, explicitly determined for each molecular species through local models. All models showed good molecular retention predictability thus showing potential for facilitating the method development.