Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Exp Astron (Dordr) ; 56(2-3): 355-370, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38145002

RESUMO

POLAR-2, a plastic scintillator based Compton polarimeter, is currently under development and planned for a launch to the China Space Station in 2025. It is intended to shed a new light on our understanding of Gamma-Ray Bursts by performing high precision polarization measurements of their prompt emission. The instrument will be orbiting at an average altitude of 383 km with an inclination of 42° and will be subject to background radiation from cosmic rays and solar events. In this work, we tested the performance of plastic scintillation bars, EJ-200 and EJ-248M from Eljen Technology, under space-like conditions, that were chosen as possible candidates for POLAR-2. Both scintillator types were irradiated with 58 MeV protons at several doses from 1.89 Gy(corresponding to about 13 years in space for POLAR-2) up to 18.7 Gy, that goes far beyond the expected POLAR-2 life time. Their respective properties, expressed in terms of light yield, emission and absorption spectra, and activation analysis due to proton irradiation are discussed. Scintillators activation analyses showed a dominant contribution of ß + decay with a typical for this process gamma-ray energy line of 511 keV.

2.
Radiat Prot Dosimetry ; 199(15-16): 1937-1940, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819291

RESUMO

The radioluminescence (RL) emitted by LiMgPO4 detector under proton beam irradiation was investigated in real time at the radiotherapy facility in the Institute of Nuclear Physics Polish Academy of Sciences in Krakow. The facility uses protons accelerated by the AIC-144 isochronous cyclotron up to the energy of 60 MeV. The measurements of RL were carried out using a remote optical fiber device with a luminophore detector and photomultiplier located at opposite ends of the optical fiber. A thin slice of LiMgPO4 doped with Tm (1.2 mol%) crystal was exposed to the proton beam. The tested detector allowed for the measurement of proton beam current, flux fluence and determination of proton beam time structure parameters. The investigation of LiMgPO4 crystal showed its high sensitivity, fast reaction time to irradiation and possibility of application as the detector for control of proton beam parameters.


Assuntos
Ciclotrons , Terapia com Prótons , Controle de Qualidade , Dosagem Radioterapêutica , Radioterapia , Ciclotrons/instrumentação , Ciclotrons/normas , Luminescência , Polônia , Terapia com Prótons/instrumentação , Terapia com Prótons/normas , Prótons , Radioatividade , Radioterapia/normas , Dosagem Radioterapêutica/normas , Metais Leves
3.
Radiat Prot Dosimetry ; 199(14): 1616-1619, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37721070

RESUMO

Quality control of therapeutic photon beams in the form of postal dose audits based on passive dosemeters is widely used in photon radiotherapy. On the other hand, no standardised dosimetry audit programme for proton centres has been established in Europe so far. We evaluated alanine/EPR dosimetry systems developed at the Istituto Superiore di Sanità (Italy), the Hasselt Universiteit (Belgium) and the Henryk Niewodniczanski Institute of Nuclear Physics Polish Academy of Sciences (Poland) for their applicability as a potential tool for routine mailed dose audits of passively scattered therapeutic proton beams. The evaluation was carried out in the form of an intercomparison. Dosemeters were irradiated in the 70 MeV proton beam at ocular proton therapy facility in the Cyclotron Centre Bronowice at the Henryk Niewodniczanski Institute of Nuclear Physics Polish Academy of Sciences in Krakow. A very good agreement was found between the dose measured by three laboratories and the delivered dose determined with an ionisation chamber. This, together with the inherent properties of alanine, such as non-destructive readout, tissue equivalence, weak energy dependence, dose rate independence and insignificant fading, makes alanine a good candidate for a dosemeter used in postal auditing in proton ocular radiotherapy.


Assuntos
Terapia com Prótons , Prótons , Olho , Radiometria , Alanina
4.
Int J Mol Sci ; 24(15)2023 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-37569531

RESUMO

Radiotherapy is a cornerstone of cancer treatment, but tumor hypoxia and resistance to radiation remain significant challenges. Vascular normalization has emerged as a strategy to improve oxygenation and enhance therapeutic outcomes. In this study, we examine the radiosensitization potential of vascular normalization using metformin, a widely used anti-diabetic drug, and oxygen microbubbles (OMBs). We investigated the synergistic action of metformin and OMBs and the impact of this therapeutic combination on the vasculature, oxygenation, invasiveness, and radiosensitivity of murine 4T1 breast cancer. We employed in vivo Doppler ultrasonographic imaging for vasculature analysis, electron paramagnetic resonance oximetry, and immunohistochemical assessment of microvessels, perfusion, and invasiveness markers. Our findings demonstrate that both two-week metformin therapy and oxygen microbubble treatment normalize abnormal cancer vasculature. The combination of metformin and OMB yielded more pronounced and sustained effects than either treatment alone. The investigated therapy protocols led to nearly twice the radiosensitivity of 4T1 tumors; however, no significant differences in radiosensitivity were observed between the various treatment groups. Despite these improvements, resistance to treatment inevitably emerged, leading to the recurrence of hypoxia and an increased incidence of metastasis.


Assuntos
Neoplasias da Mama , Metformina , Camundongos , Humanos , Animais , Feminino , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/radioterapia , Microbolhas , Oxigênio , Metformina/farmacologia , Metformina/uso terapêutico , Hipóxia Tumoral
5.
Exp Astron (Dordr) ; 55(2): 343-371, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37063519

RESUMO

POLAR-2 is a space-borne polarimeter, built to investigate the polarization of Gamma-Ray Bursts and help elucidate their mechanisms. The instrument is targeted for launch in 2024 or 2025 aboard the China Space Station and is being developed by a collaboration between institutes from Switzerland, Germany, Poland and China. The instrument will orbit at altitudes between 340km and 450km with an inclination of 42 ∘ and will be subjected to background radiation from cosmic rays and solar events. It is therefore pertinent to better understand the performance of sensitive devices under space-like conditions. In this paper we focus on the radiation damage of the silicon photomultiplier arrays S13361-6075NE-04 and S14161-6050HS-04 from Hamamatsu. The S13361 are irradiated with 58MeV protons at several doses up to 4.96Gy, whereas the newer series S14161 are irradiated at doses of 0.254Gy and 2.31Gy. Their respective performance degradation due to radiation damage are discussed. The equivalent exposure time in space for silicon photomultipliers inside POLAR-2 with a dose of 4.96Gy is 62.9years (or 1.78years when disregarding the shielding from the instrument). Primary characteristics of the I-V curves are an increase in the dark current and dark counts, mostly through cross-talk events. Annealing processes at 25 ∘ C were observed but not studied in further detail. Biasing channels while being irradiated have not resulted in any significant impact. Activation analyses showed a dominant contribution of ß + particles around 511 keV. These resulted primarily from copper and carbon, mostly with decay times shorter than the orbital period.

6.
Free Radic Biol Med ; 199: 166-176, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36858326

RESUMO

The inadequate level of oxygenation in tumors has been shown to correlate not only with greater invasiveness of cancer cells, but also with a reduction in their sensitivity to anticancer therapies. Over the years, many attempts have been made to increase the oxygenation level of cancer, but most of them have been ineffective. We investigated the heterogeneous response of tumor tissue to phospholipid-coated oxygen microbubbles (OMB) in murine tumors in vivo using oxygen and hemoglobin saturation mapping and the influence of OMB treatment on microvasculature, perfusion, and radiotherapy effectiveness. Intravenous administration of OMB followed by ultrasound pulse leads to increased oxygenation of a tumor, found mainly in the vicinity of tumor vessels, while intratumoral delivery resulted in areas of increased pO2 more evenly distributed within the tumor. Furthermore, hemoglobin contributes little to the increase in tumor oxygenation caused by oxygen microbubbles. Extensive vasculature disruption was observed in the groups treated with both oxygen/nitrogen microbubbles and ultrasound pulse. This therapy also led to a reduction in the coverage of the vessels by pericytes, while the density of the microvessels was unchanged. Radiotherapy with a single dose of 12Gy reduced tumor growth by 50% in all treated groups. Unfortunately, at the same time, the number of macroscopic metastases in the lungs increased significantly after intravenous administration of oxygen/nitrogen microbubbles and the application of an ultrasound pulse. In conclusion, ultrasound-sensitive oxygen microbubbles are effective in delivering oxygen to tumor tissue, thus increasing the effectiveness of radiotherapy. However, cavitation effects and destruction of the integrity of tumor vessels result in greater spread of cancer cells in the host organism.


Assuntos
Neoplasias da Mama , Camundongos , Humanos , Animais , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/tratamento farmacológico , Microbolhas , Oxigênio , Ultrassonografia , Oximetria
7.
Materials (Basel) ; 16(5)2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36903093

RESUMO

Modern radiotherapy (RT) techniques, such as proton therapy, require more and more sophisticated dosimetry methods and materials. One of the newly developed technologies is based on flexible sheets made of a polymer, with the embedded optically stimulated luminescence (OSL) material in the form of powder (LiMgPO4, LMP) and a self-developed optical imaging setup. The detector properties were evaluated to study its potential application in the proton treatment plan verification for eyeball cancer. The data showed a well-known effect of lower luminescent efficiency of the LMP material response to proton energy. The efficiency parameter depends on a given material and radiation quality parameters. Therefore, the detailed knowledge of material efficiency is crucial in establishing a calibration method for detectors exposed to mixed radiation fields. Thus, in the present study, the prototype of the LMP-based silicone foil material was tested with monoenergetic uniform proton beams of various initial kinetic energies constituting the so-called spread-out Bragg peak (SOBP). The irradiation geometry was also modelled using the Monte Carlo particle transport codes. Several beam quality parameters, including dose and the kinetic energy spectrum, were scored. Finally, the obtained results were used to correct the relative luminescence efficiency response of the LMP foils for monoenergetic and spread-out proton beams.

8.
Radiat Prot Dosimetry ; 198(19): 1471-1475, 2022 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-36138419

RESUMO

The Maastro Proton Therapy Centre is the first European facility housing the Mevion S250i Hyperscan synchrocyclotron. The proximity of the accelerator to the patient, the presence of an active pencil beam delivery system downstream of a passive energy degrader and the pulsed structure of the beam make the Mevion stray neutron field unique amongst proton therapy facilities. This paper reviews the results of a rem-counter intercomparison experiment promoted by the European Radiation Dosimetry Group at Maastro and compares them with those at other proton therapy facilities. The Maastro neutron H*(10) in the room (100-200 µSv/Gy at about 2 m from the isocentre) is in line with accelerators using purely passive or wobbling beam delivery modalities, even though Maastro shows a dose gradient peaked near the accelerator. Unlike synchrotron- and cyclotron-based facilities, the pulsed beam at Maastro requires the employment of rem-counters specifically designed to withstand pulsed neutron fields.


Assuntos
Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Doses de Radiação , Nêutrons , Radiometria/métodos , Ciclotrons , Dosagem Radioterapêutica
9.
Phys Med Biol ; 2022 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-35259730

RESUMO

Objective Proton therapy is gaining popularity because of the improved dose delivery over conventional radiation therapy. The secondary dose to healthy tissues is dominated by secondary neutrons. Commercial rem-counters are valuable instruments for the on-line assessment of neutron ambient dose equivalent (H*(10)). In general, however, a priori knowledge of the type of facility and of the radiation field is required for the proper choice of any survey meter. The novel Mevion S250i Hyperscan synchrocyclotron mounts the accelerator directly on the gantry. It provides a scanned 227 MeV proton beam, delivered in pulses with a pulse width of 10 µs at 750 Hz frequency, which is afterwards degraded in energy by a range shifter modulator system. This environment is particularly challenging for commercial rem-counters; therefore, we tested the reliability of some of the most widespread rem-counters to understand their limits in the Mevion S250i stray neutron field. Approach This work, promoted by the European Radiation Dosimetry Group (EURADOS), describes a rem-counter intercomparison at the Maastro Proton Therapy centre in the Netherlands, which houses the novel Mevion S250i Hyperscan system. Several rem-counters were employed in the intercomparison (LUPIN, LINUS, WENDI-II, LB6411, NM2B-458, NM2B-495Pb), which included simulation of a patient treatment protocol employing a water tank phantom. The outcomes of the experiment were compared with models and data from the literature. Main results We found that only the LUPIN allowed for a correct assessment of H*(10) within a 20% uncertainty. All other rem-counters underestimated the reference H*(10) by factors from 2 to more than 10, depending on the detector model and on the neutron dose per pulse. In pulsed fields, the neutron dose per pulse is a fundamental parameter, while the average neutron dose rate is a secondary quantity. An average 150-200 µSv/GyRBE neutron H*(10) at various positions around the phantom and at distances between 186 cm and 300 cm from it was measured per unit therapeutic dose delivered to the target. Significance Our results are partially in line with results obtained at similar Mevion facilities employing passive energy modulation. Comparisons with facilities employing active energy modulation confirmed that the neutron H*(10) can increase up to more than a factor of 10 when passive energy modulation is employed. The challenging environment of the Mevion stray neutron field requires the use of specific rem-counters sensitive to high-energy neutrons (up to a few hundred MeV) and specifically designed to withstand pulsed neutron fields.

10.
Phys Med Biol ; 67(1)2022 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-34933289

RESUMO

Objective. Treatment planning based on computer simulations wasproposed to account for the increased relative biological effectiveness (RBE) of proton radiotherapy beams near to the edges of the irradiated volume. Since silicon detectors could be used to validate the results of these simulations, it is important to explore the limitations of this comparison.Approach. Microdosimetric measurements with a MicroPlus Bridge V2 silicon detector (thickness = 10µm) were performed along the Bragg peak of a clinical proton beam. The lineal energy distributions, the dose-mean values, and the RBE calculated with a biological weighting function were compared with PHITS simulations (microdosimetric target = 1µm water sphere), and published clonogenic survivalin vitroRBE data for the V79 cell line. The effect of the silicon-to-water conversion was also investigated by comparing three different methodologies (conversion based on a single value, novel bin-to-bin conversions based on SRIM and PSTAR).Main results. Mainly due to differences in the microdosimetric targets, the experimental dose-mean lineal energy and RBE values at the distal edge were respectively up to 53% and 28% lower than the simulated ones. Furthermore, the methodology chosen for the silicon-to-water conversion was proven to affect the dose-mean lineal energy and the RBE10up to 32% and 11% respectively. The best methodology to compensate for this underestimation was the bin-to-bin silicon-to-water conversion based on PSTAR.Significance. This work represents the first comparison between PHITS-simulated lineal energy distributions in water targets and corresponding experimental spectra measured with silicon detectors. Furthermore, the effect of the silicon-to-water conversion on the RBE was explored for the first time. The proposed methodology based on the PSTAR bin-to-bin conversion appears to provide superior results with respect to commonly used single scaling factors and is recommended for future studies.


Assuntos
Terapia com Prótons , Método de Monte Carlo , Terapia com Prótons/métodos , Prótons , Silício , Água
11.
Sensors (Basel) ; 21(18)2021 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-34577220

RESUMO

A direct verification of the three-dimensional (3D) proton clinical treatment plan prepared for tumor in the eyeball, using the Eclipse Ocular Proton Planning system (by Varian Medical Systems), has been presented. To achieve this, a prototype of the innovative two-dimensional (2D) circular silicone foils, made of a polymer with the embedded optically stimulated luminescence (OSL) material in powder form (LiMgPO4), and a self-developed optical imaging system, consisting of an illuminating light source and a high-sensitive CCD camera has been applied. A specially designed lifelike eyeball phantom has been used, constructed from 40 flat sheet LMP-based silicone foils stacked and placed together behind a spherical phantom made by polystyrene, all to reflect the curvature of the real eyeball. Two-dimensional OSL signals were captured and further analyzed from each single silicone foil after irradiation using a dedicated patient collimator and a 58.8 MeV modulated proton beam. The reconstructed 3D proton depth dose distribution matches very well with the clinical treatment plan, allowing for the consideration of the new OSL system for further 3D dosimetry applications within the proton radiotherapy area.


Assuntos
Neoplasias , Prótons , Humanos , Luminescência , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Silicones
12.
Int J Radiat Biol ; 96(10): 1238-1244, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32780616

RESUMO

PURPOSE: Conventional X-ray radiotherapy induces a pro-inflammatory response mediated by altered expression of inflammation-regulating cytokines. Proton scanning and X-ray irradiation produce distinct changes to cytokine gene expression in vitro suggesting that proton beam therapy may induce an inflammatory response dissimilar to that of X-ray radiation. The purpose of the present study was to determine whether proton scanning beam radiation and conventional X-ray photon radiation would induce differential regulation of circulating cytokines in vivo. MATERIALS AND METHODS: Female CDF1 mice were irradiated locally at the right hind leg using proton pencil beam scanning or X-ray photons. Blood samples were obtained from two separate mice groups. Samples from one group were drawn by retro-orbital puncture 16 months post irradiation, while samples from the other group were drawn 5 and 30 days post irradiation. Concentration of the cytokines IL-6, IL-1ß, IL-10, IL-17A, IFN-γ, and TNFα was measured in plasma using bead-based immunoassays. RESULTS: The cytokines IL-6, IL-1ß, IL-10, IFN-γ, and TNFα were expressed at lower levels in plasma samples from proton-irradiated mice compared with X-ray-irradiated mice 16 months post irradiation. The same cytokines were downregulated in proton-irradiated mice 5 days post irradiation when compared to controls, while at day 30 expression had increased to the same level or higher. X-ray radiation did not markedly change expression levels at days 5 and 30. CONCLUSIONS: The inflammatory response to proton and X-ray irradiation seem to be distinct as the principal pro-inflammatory cytokines are differentially regulated short- and long-term following irradiation. Both the development of normal tissue damage and efficacy of immunotherapy could be influenced by an altered inflammatory response to irradiation.


Assuntos
Citocinas/metabolismo , Prótons , Animais , Feminino , Inflamação/metabolismo , Camundongos , Pele/metabolismo , Pele/efeitos da radiação , Fatores de Tempo , Raios X
13.
Phys Med Biol ; 65(1): 015008, 2020 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-31569080

RESUMO

Changes in the relative biological effectiveness (RBE) of the radiation-induced cell killing of human salivary glands (HSG) were assessed along the Bragg peak of a 60 MeV clinical proton beam by means of coupling biophysical models with the results of Monte Carlo radiation transport simulations and experimental measurements with luminescent detectors. The fluence- and dose-mean unrestricted proton LET were determined along the Bragg peak using a recently developed methodology based on the combination of the response of 7LiF:Mg,Ti (MTS-7) and 7LiF:Mg,Cu,P (MCP-7) thermoluminescent detectors. The experimentally assessed LET values were compared with the results of radiation transport simulations using the Monte Carlo code PHITS, showing a good agreement. The cell survival probabilities and RBE were then calculated using the linear-quadratic model with the linear term derived using a phenomenological LET-based model (Carabe A et al 2012 Phys. Med. Biol. 57 1159) in combination with the experimentally-assessed or PHITS-simulated dose mean proton LET values. To the same aim, PHITS simulated microdosimetric spectra were used as input to the modified microdosimetric kinetic model (modified MKM, (Kase et al 2006 Radiat. Res. 166 629-38)). The RBE values calculated with the three aforementioned approaches were compared and found to be in very good agreement between each other, proving that by using dedicated pairs of thermoluminescent detectors it is possible to determine ionization density quantities of therapeutic proton beams which can be applied to predict the local value of the RBE.


Assuntos
Morte Celular , Simulação por Computador , Modelos Estatísticos , Prótons , Glândulas Salivares/patologia , Dosimetria Termoluminescente/instrumentação , Células Cultivadas , Relação Dose-Resposta à Radiação , Humanos , Cinética , Método de Monte Carlo , Eficiência Biológica Relativa , Glândulas Salivares/efeitos da radiação
14.
Sci Rep ; 9(1): 7008, 2019 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-31065009

RESUMO

Cellular response to non-lethal radiation stress include perturbations in DNA repair, angiogenesis, migration, and adhesion, among others. Low-LET proton beam radiation has been shown to induce somewhat different biological response than photon radiation. For example, we have shown that non-lethal doses of proton beam radiation inhibited migration of cells and that this effect persisted long-term. Here, we have examined cellular elasticity and actin cytoskeleton organization in BLM cutaneous melanoma and Mel270 uveal melanoma cells. Proton beam radiation increased cellular elasticity to a greater extent than X-rays and both types of radiation induced changes in actin cytoskeleton organization. Vimentin level increased in BLM cells after both types of radiation. Our data show that cell elasticity increased substantially after low-LET proton beam and persisted long after radiation. This may have significant consequences for the migratory properties of melanoma cells, as well as for the cell susceptibility to therapy.


Assuntos
Citoesqueleto de Actina/efeitos da radiação , Melanoma/metabolismo , Terapia com Prótons/métodos , Neoplasias Cutâneas/metabolismo , Neoplasias Uveais/metabolismo , Vimentina/metabolismo , Citoesqueleto de Actina/metabolismo , Linhagem Celular Tumoral , Movimento Celular/efeitos da radiação , Proliferação de Células/efeitos da radiação , Sobrevivência Celular/efeitos da radiação , Elasticidade/efeitos da radiação , Regulação Neoplásica da Expressão Gênica/efeitos da radiação , Humanos , Melanoma/radioterapia , Neoplasias Cutâneas/radioterapia , Regulação para Cima , Neoplasias Uveais/radioterapia , Melanoma Maligno Cutâneo
15.
Int J Radiat Oncol Biol Phys ; 103(5): 1203-1211, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30529373

RESUMO

PURPOSE: To identify differential cellular responses after proton and photon irradiation by comparing transcriptomes of primary fibroblasts irradiated with either radiation type. METHODS AND MATERIALS: A panel of primary dermal fibroblast cultures was irradiated with low and higher linear energy transfer (LET) proton beams. Cobalt-60 photon irradiation was used as reference. Dose was delivered in 3 fractions of 3.5 Gy (relative biological effectiveness) using a relative biological effectiveness of 1.1 for proton doses. Cells were harvested 2 hours after the final fraction was delivered, and RNA was purified. RNA sequencing was performed using Illumina NextSeq 500 with high-output kit. The edgeR package in R was used for differential gene expression analysis. RESULTS: Pairwise comparisons of the transcriptomes in the 3 treatment groups showed that there were 84 and 56 differentially expressed genes in the low LET group compared with the Cobalt-60 group and the higher LET group, respectively. The higher LET proton group and the Cobalt-60 group had the most distinct transcriptome profiles, with 725 differentially regulated genes. Differentially regulated canonical pathways and various regulatory factors involved in regulation of biological mechanisms such as inflammation, carcinogenesis, and cell cycle control were identified. CONCLUSIONS: Inflammatory regulators associated with the development of normal tissue complications and malignant transformation factors seem to be differentially regulated by higher LET proton and Cobalt-60 photon irradiation. The reported transcriptome differences could therefore influence the progression of adverse effects and the risk of developing secondary cancers.


Assuntos
Radioisótopos de Cobalto/farmacologia , Fibroblastos/efeitos da radiação , Perfilação da Expressão Gênica/métodos , Transferência Linear de Energia , Fótons , Prótons , Transcriptoma/efeitos da radiação , Carcinogênese/genética , Pontos de Checagem do Ciclo Celular/genética , Células Cultivadas , Humanos , Inflamação/genética , Método de Monte Carlo , Reação em Cadeia da Polimerase em Tempo Real , Eficiência Biológica Relativa , Análise de Sequência de RNA/métodos , Transcriptoma/genética
16.
Int J Radiat Biol ; 94(12): 1085-1094, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30273081

RESUMO

Purpose: The aim of our study was to investigate the amount of initial DNA damage and cellular repair capacity of human peripheral blood lymphocytes exposed to the therapeutic proton beam and compare it to X-rays. Materials and methods: Lymphocytes from 10 healthy donors were irradiated in the Spread Out Bragg Peak of the 60 MeV proton beam or, as a reference, exposed to 250 kV X-rays. DNA damage level was assessed using the alkaline version of the comet assay method. For both sources of radiation, dose-DNA damage response (0-4 Gy) and DNA repair kinetics (0-120 min) were estimated. The observed DNA damage was then used to calculate the relative biological effectiveness (RBE) of the proton beam in comparison to that of X-rays. Results: Dose-response relationships for the DNA damage level showed linear dependence for both proton beam and X-rays (R2 = 0.995 for protons and R2 = 0.993 for X-rays). Within the dose range of 1-4 Gy, protons were significantly more effective in inducing DNA damage than were X-rays (p < .05). The average RBE, calculated from the proton and X-ray doses required for the iso-effective, internally standardized tail DNA parameter (sT-DNA) was 1.28 ± 0.57. Similar half-life time of residual damage and repair efficiency of induced DNA damage for both radiation types were observed. In the X-irradiated group, significant inter-individual differences were observed. Conclusions: Proton therapy was more effective at high radiation doses. However, DNA damage repair mechanism after proton irradiation seems to differ from that following X-rays.


Assuntos
Linfócitos/efeitos da radiação , Terapia com Prótons , Adulto , Dano ao DNA , Reparo do DNA , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Eficiência Biológica Relativa
17.
Int J Mol Sci ; 19(8)2018 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-30065179

RESUMO

Proton beam irradiation promises therapeutic utility in the management of uveal melanoma. Calcitriol (1,25(OH)2D3)-the biologically active metabolite of vitamin D3-and its precursor, calcidiol (25(OH)D3), exert pleiotropic effects on melanoma cells. The aim of the study was to evaluate the effect of both calcitriol and calcidiol on melanoma cell proliferation and their response to proton beam irradiation. Three melanoma cell lines (human SKMEL-188 and hamster BHM Ma and BHM Ab), pre-treated with 1,25(OH)2D3 or 25(OH)D3 at graded concentrations (0, 10, 100 nM), were irradiated with 0⁻5 Gy and then cultured in vitro. Growth curves were determined by counting the cell number every 24 h up to 120 h, which was used to calculate surviving fractions. The obtained survival curves were analysed using two standard models: linear-quadratic and multi-target single hit. Calcitriol inhibited human melanoma proliferation at 10 nM, while only calcidiol inhibited proliferation of hamster lines at 10 and 100 nM doses. Treatment with either 1,25(OH)2D3 or 25(OH)D3 radio sensitized melanoma cells to low doses of proton beam radiation. The strength of the effect increased with the concentration of vitamin D3. Our data suggest that vitamin D3 may be an adjuvant that modifies proton beam efficiency during melanoma therapy.


Assuntos
Calcifediol/farmacologia , Calcitriol/farmacologia , Melanoma/metabolismo , Animais , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Proliferação de Células/efeitos da radiação , Colecalciferol/farmacologia , Cricetinae , Humanos , Terapia com Prótons
18.
Sci Rep ; 8(1): 12688, 2018 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-30139945

RESUMO

The transcriptional response of cells exposed to proton radiation is not equivalent to the response induced by traditional photon beams. Changes in cellular signalling is most commonly studied using the method Quantitative polymerase chain reaction (qPCR). Stable reference genes must be used to accurately quantify target transcript expression. The study aim was to identify suitable reference genes for normalisation of gene expression levels in normal dermal fibroblasts irradiated with either proton or photon beams. The online tool RefFinder was used to analyse and identify the most stably expressed genes from a panel of 22 gene candidates. To assess the reliability of the identified reference genes, a selection of the most and least stable reference genes was used to normalise target transcripts of interest. Fold change levels varied considerably depending on the used reference gene. The top ranked genes IPO8, PUM1, MRPL19 and PSMC4 produced highly similar target gene expression, while expression using the worst ranked genes, TFRC and HPRT1, was clearly modified due to reference gene instability.


Assuntos
Fibroblastos/metabolismo , Fótons , Prótons , Reação em Cadeia da Polimerase em Tempo Real/métodos , Células Cultivadas , Fibroblastos/efeitos da radiação , Perfilação da Expressão Gênica , Regulação Neoplásica da Expressão Gênica/efeitos da radiação , Humanos , Método de Monte Carlo
19.
Radiat Prot Dosimetry ; 180(1-4): 351-354, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29529272

RESUMO

The aim of these studies was to investigate depth dose distribution of a 60 MeV proton beam formed by a set of dedicated mesh-formed collimators. The set of mini-beams formed by the mesh is scattered in the tissue and lead to uniform energy deposition in the target volume. The rationale is to protect the eyelid skin from complications after hypofractionated radiation therapy. The experimental verification of the depth dose distribution for collimators of 1-3 mm mesh size was performed in solid state and water phantoms on 60 MeV proton beam from the AIC-144 cyclotron. The measurements were accompanied by Monte Carlo calculations of proton transport using the FLUKA code. The result demonstrate that the smallest mesh diameter of 1 mm leads to fast broadening of the resulting mini-beams due to multiple proton scattering in the collimator. The effect is diminishing with growing collimator diameter.


Assuntos
Fracionamento da Dose de Radiação , Neoplasias Oculares/radioterapia , Imagens de Fantasmas , Terapia com Prótons/instrumentação , Terapia com Prótons/métodos , Radiometria/métodos , Pele/efeitos da radiação , Humanos , Proteção Radiológica
20.
PLoS One ; 12(10): e0186002, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29016654

RESUMO

PURPOSE: In recent years experimental data have indicated that low-energy proton beam radiation might induce a difference in cellular migration in comparison to photons. We therefore set out to compare the effect of proton beam irradiation and X-rays on the survival and long-term migratory properties of two cell lines: uveal melanoma Mel270 and skin melanoma BLM. MATERIALS AND METHODS: Cells treated with either proton beam or X-rays were analyzed for their survival using clonogenic assay and MTT test. Long-term migratory properties were assessed with time-lapse monitoring of individual cell movements, wound test and transpore migration, while the expression of the related proteins was measured with western blot. RESULTS: Exposure to proton beam and X-rays led to similar survival but the quality of the cell colonies was markedly different. More paraclones with a low proliferative activity and fewer highly-proliferative holoclones were found after proton beam irradiation in comparison to X-rays. At 20 or 40 days post-irradiation, migratory capacity was decreased more by proton beam than by X-rays. The beta-1-integrin level was decreased in Mel270 cells after both types of radiation, while vimentin, a marker of EMT, was increased in BLM cells only. CONCLUSIONS: We conclude that proton beam irradiation induced long-term inhibition of cellular motility, as well as changes in the level of beta-1 integrin and vimentin. If confirmed, the change in the quality, but not in the number of colonies after proton beam irradiation might favor tumor growth inhibition after fractionated proton therapy.


Assuntos
Movimento Celular/efeitos da radiação , Integrina beta1/genética , Melanócitos/efeitos da radiação , Terapia com Prótons , Vimentina/genética , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos da radiação , Células Clonais , Expressão Gênica/efeitos da radiação , Humanos , Integrina beta1/metabolismo , Melanócitos/metabolismo , Melanócitos/patologia , Especificidade de Órgãos , Imagem com Lapso de Tempo , Vimentina/metabolismo , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...