Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Monit Assess ; 184(3): 1471-86, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21509510

RESUMO

Airborne particulate matter (PM) has become one of the dominant pollutants with the increasing material and energy demand due to global economic growth. The main objective of this research is to provide a comprehensive receptor level characterisation of the particulate matter collected in a city environment. Particulate matter samples were collected on Tapered Element Oscillating Microbalance (TEOM) filters from five monitoring sites over a period of 1 year. An Andersen eight-stage cascade impactor was also used to collect airborne PM samples from three other locations to compare with the samples collected by TEOM. All the samples were then subjected to individual particle morphology and chemical composition analysis by SEM/EDS. Bulk chemical composition of the samples were also analysed through ICP-OES. Based on these analyses, possible sources of the PM samples were identified. The results showed that the monitoring sites in residential environments were dominated by transportation-derived particles and other migratory particulates. Monitoring sites near the city centre were dominant by particles from transportation, with biological particles abundant for the site closer to a river. The monitoring station located close to the industrial area, despite only 200 m away from a motorway, has low contribution of non-exhaust particulates from vehicles. Instead, the particulates collected from this site were dominated by industrial sources. An air dispersion modelling package was also used to model the particulate matter dispersion in the city area for the period of sampling. The results from the model showed that the points of high emissions were around industrial areas.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental , Material Particulado/análise , Poluentes Atmosféricos/química , Poluição do Ar/estatística & dados numéricos , Cidades/estatística & dados numéricos , Meio Ambiente , Modelos Químicos , Tamanho da Partícula , Material Particulado/química
2.
J Hazard Mater ; 186(1): 218-26, 2011 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-21146293

RESUMO

The deposition of ash - combustion residues - on superheaters and heat exchanger surfaces reduce their efficiency; this phenomenon was investigated for a large-scale waste-to-energy incineration facility. Over a period of six months, ash samples were collected from the plant, which included the bottom ash and deposits from the superheater, as well as flyash from the convective heat exchanger, the economiser and fabric filters. These were analysed for particle size, unburned carbon, elemental composition and surface morphology. Element partitioning was evident in the different combustion residues, as volatile metals, such as cadmium, antimony and arsenic, were found to be depleted in the bottom ash by the high combustion temperatures (1000+°C) and concentrated/enriched in the fabric filter ash (transferred by evaporation). Non-volatile elements by contrast were distributed equally in all locations (transported by particle entrainment). The heat exchanger deposits and fabric filter ash had elevated levels of alkali metals. 82% of flyash particles from the fabric filter were in the submicron range.


Assuntos
Incineração , Eliminação de Resíduos , Microscopia Eletrônica de Varredura , Tamanho da Partícula , Propriedades de Superfície
3.
Bioresour Technol ; 100(1): 310-5, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18625549

RESUMO

Thermal treatment technologies were compared to determine an appropriate method of recovering energy from two wastes - spent mushroom compost and coal tailings. The raw compost and pellets of these wastes were combusted in a fluidised-bed and a packed-bed, and contrasted to pyrolysis and gasification. Quantitative combustion parameters were compared to assess the differences in efficiency between the technologies. Fluidised-bed combustion was more efficient than the packed-bed in both instances and pellet combustion was superior to that of the compost alone. Acid gas emissions (NO(x), SO(x) and HCl) were minimal for the fluidised-bed, thus little gas cleaning would be required. The fuels' high ash content (34%) also suggests fluidised-bed combustion would be preferred. The Alkali Index of the ash indicates the possibility of fouling/slagging within the system, caused by the presence of alkali metal oxides. Pyrolysis produced a range of low-calorific value-products, while gasification was not successful.


Assuntos
Agaricales/química , Fontes de Energia Bioelétrica , Biotecnologia/métodos , Carvão Mineral/análise , Conservação de Recursos Energéticos/métodos , Solo/análise , Transferência de Energia , Temperatura Alta
4.
Waste Manag ; 28(11): 2245-58, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18513938

RESUMO

Fluidised bed combustor (FBC) is one of the key technologies for sewage sludge incineration. In this paper, a mathematical model is developed for the simulation of a large-scale sewage sludge incineration plant. The model assumes the bed consisting of a fast-gas phase, an emulsion phase and a fuel particle phase with specific consideration for thermally-thick fuel particles. The model further improves over previous works by taking into account throughflow inside the bubbles as well as the floating and random movement of the fuel particles inside the bed. Validation against both previous lab-scale experiments and operational data of a large-scale industrial plant was made. Calculation results indicate that combustion split between the bed and the freeboard can range from 60/40 to 90/10 depending on the fuel particle distribution across the bed height under the specific conditions. The bed performance is heavily affected by the variation in sludge moisture level. The response time to variation in feeding rate is different for different parameters, from 6 min for outlet H2O, 10 min for O2, to 34 min for bed temperature.


Assuntos
Esgotos/análise , Emulsões , Gases/análise , Incineração , Cinética , Matemática , Modelos Teóricos , Eliminação de Resíduos/métodos , Termodinâmica , Eliminação de Resíduos Líquidos/métodos
5.
Waste Manag ; 28(8): 1290-300, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-17697769

RESUMO

Packed bed combustion is still the most common way to burn municipal solid wastes. In this paper, a dispersion model for particle mixing, mainly caused by the movement of the grate in a moving-burning bed, has been proposed and transport equations for the continuity, momentum, species, and energy conservation are described. Particle-mixing coefficients obtained from model tests range from 2.0x10(-6) to 3.0x10(-5)m2/s. A numerical solution is sought to simulate the combustion behaviour of a full-scale 12-tonne-per-h waste incineration furnace at different levels of bed mixing. It is found that an increase in mixing causes a slight delay in the bed ignition but greatly enhances the combustion processes during the main combustion period in the bed. A medium-level mixing produces a combustion profile that is positioned more at the central part of the combustion chamber, and any leftover combustible gases (mainly CO) enter directly into the most intensive turbulence area created by the opposing secondary-air jets and thus are consumed quickly. Generally, the specific arrangement of the impinging secondary-air jets dumps most of the non-uniformity in temperature and CO into the gas flow coming from the bed-top, while medium-level mixing results in the lowest CO emission at the furnace exit and the highest combustion efficiency in the bed.


Assuntos
Eliminação de Resíduos/métodos , Monóxido de Carbono , Cidades , Simulação por Computador , Gases , Incineração , Modelos Químicos , Modelos Teóricos , Tamanho da Partícula , Medição de Risco , Temperatura
6.
Waste Manag ; 27(5): 645-55, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-16730435

RESUMO

Waste incineration is a politically sensitive issue in the UK. The major current technology is based on direct combustion of wastes in a moving-grate furnace. However, general public opinion prefers non-direct burning technologies. Waste gasification is one of those nearest technologies available. By reducing the primary air-flow rate through the grate of a packed-bed system, operation of the existing solid-waste incineration equipment can be easily converted from combustion mode to gasification mode without major modification of the hardware. The potential advantages of this are lower dust carry-over in the flue gases, lower bed temperature (and therefore lower NO(x) formation in the bed), simplified gas-treatment procedures and lower running cost, among other benefits. The major disadvantages are, however, reduced throughput of the wastes and possibly higher carbon in the ash at exit. In this study, numerical simulation of both combustion and gasification of municipal solid wastes in a full-scale moving grate furnace is carried out employing advanced mathematical models. Burning characteristics, including burning rate, gas composition, temperature and burning efficiency as a function of operating parameters are investigated. Detailed comparisons between the combustion mode and gasification mode are made. The study helps to explore new incineration technology and optimise furnace operating conditions.


Assuntos
Simulação por Computador , Incineração/instrumentação , Modelos Teóricos , Carbono , Gases , Eliminação de Resíduos , Temperatura
7.
Waste Manag ; 27(6): 802-10, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-16790338

RESUMO

Recent developments in national recycling and re-use programmes for municipal waste have led to segregation of an increasing proportion of waste to enhance material recovery. Several of the segregated streams contain materials that can not viably be re-used or recycled but can be used for energy recovery. In this study, the combustion of cardboard and waste wood was investigated in a small-scale packed bed reactor in order to provide fundamental data for the design/operation of moving bed furnaces. Key parameters of combustion including the ignition and burning rates were evaluated for various air flowrates and compared to the modelling results. Two successive stages of combustion were identified for both samples: the propagation of ignition front into the bed and combustion of the fuel above the ignition front. The burning rate of cardboard reached a peak of about 300 kg/m(2)h at the air flowrate of 936 kg/m(2)h and decreased at higher air flowrates. For waste wood, both the ignition and burning rates increased in the tested range of the air flowrate up to 702 kg/m(2)h, of which the values were very close to those for the cardboard. The model prediction was in good agreement with the test results for waste wood. However, the burning rate for cardboard was under-predicted due to strongly irregular shapes of the fuel.


Assuntos
Incineração/métodos , Ar , Conservação de Recursos Energéticos/métodos , Modelos Teóricos , Temperatura , Fatores de Tempo , Madeira
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...