Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Anesth ; 95: 111465, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38581926

RESUMO

OBJECTIVE: Test the hypothesis that one-lung ventilation with variable tidal volume improves intraoperative oxygenation and reduces postoperative pulmonary complications after lung resection. BACKGROUND: Constant tidal volume and respiratory rate ventilation can lead to atelectasis. Animal and human ARDS studies indicate that oxygenation improves with variable tidal volumes. Since one-lung ventilation shares characteristics with ARDS, we tested the hypothesis that one-lung ventilation with variable tidal volume improves intraoperative oxygenation and reduces postoperative pulmonary complications after lung resection. DESIGN: Randomized trial. SETTING: Operating rooms and a post-anesthesia care unit. PATIENTS: Adults having elective open or video-assisted thoracoscopic lung resection surgery with general anesthesia were randomly assigned to intraoperative ventilation with fixed (n = 70) or with variable (n = 70) tidal volumes. INTERVENTIONS: Patients assigned to fixed ventilation had a tidal volume of 6 ml/kgPBW, whereas those assigned to variable ventilation had tidal volumes ranging from 6 ml/kg PBW ± 33% which varied randomly at 5-min intervals. MEASUREMENTS: The primary outcome was intraoperative oxygenation; secondary outcomes were postoperative pulmonary complications, mortality within 90 days of surgery, heart rate, and SpO2/FiO2 ratio. RESULTS: Data from 128 patients were analyzed with 65 assigned to fixed-tidal volume ventilation and 63 to variable-tidal volume ventilation. The time-weighted average PaO2 during one-lung ventilation was 176 (86) mmHg in patients ventilated with fixed-tidal volume and 147 (72) mmHg in the patients ventilated with variable-tidal volume, a difference that was statistically significant (p < 0.01) but less than our pre-defined clinically meaningful threshold of 50 mmHg. At least one composite complication occurred in 11 (17%) of patients ventilated with variable-tidal volume and in 17 (26%) of patients assigned to fixed-tidal volume ventilation, with a relative risk of 0.67 (95% CI 0.34-1.31, p = 0.24). Atelectasis in the ventilated lung was less common with variable-tidal volumes (4.7%) than fixed-tidal volumes (20%) in the initial three postoperative days, with a relative risk of 0.24 (95% CI 0.01-0.8, p = 0.02), but there were no significant late postoperative differences. No other secondary outcomes were both statistically significant and clinically meaningful. CONCLUSION: One-lung ventilation with variable tidal volume does not meaningfully improve intraoperative oxygenation, and does not reduce postoperative pulmonary complications.


Assuntos
Anestesia Geral , Ventilação Monopulmonar , Complicações Pós-Operatórias , Volume de Ventilação Pulmonar , Humanos , Ventilação Monopulmonar/métodos , Ventilação Monopulmonar/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Anestesia Geral/métodos , Oxigênio/sangue , Cirurgia Torácica Vídeoassistida/métodos , Cirurgia Torácica Vídeoassistida/efeitos adversos , Resultado do Tratamento , Pneumonectomia/efeitos adversos , Pneumonectomia/métodos , Pulmão/cirurgia , Frequência Cardíaca , Atelectasia Pulmonar/prevenção & controle , Atelectasia Pulmonar/etiologia , Atelectasia Pulmonar/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...