Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
J Glaucoma ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38874528

RESUMO

PRCIS: About 1/4th of survey respondents from an ASCRS database initiate treatment for primary open-angle glaucoma (POAG) with laser trabeculoplasty. Factors impacting physicians' choice of laser versus topical treatment for POAG were explored. PURPOSE: To characterize primary treatment preferences (topical medication vs. laser trabeculoplasty or intracameral sustained release implants) in primary open-angle glaucoma (POAG) patients and determine factors related to primary intervention selection. METHODS: A 33-question survey was distributed to an American Society of Cataract and Refractive Surgery database on treatment choices made by ophthalmologists for POAG. Data collected included country of practice, years of practice, completion of glaucoma fellowship training, type of practice, and preference for first line of treatment of POAG. Multiple logit regression was used to compare the effect of covariates on physicians' choice of either topical medication or laser trabeculoplasty for POAG. RESULTS: A total of 252/19,246 (1.3%) of surveys were returned. Almost three-quarters of respondents utilized topical medication as first line of treatment for POAG (73.6%) while 26.4% preferred to start with laser treatment. Significant variables associated with the selection of laser (vs. drops) are practicing in the U.S. (odds ratio [OR] 2.85, 95% confidence interval [CI] 1.33-6.10), more recent completion of ophthalmology residency (OR 1.95, 95% CI 1.00-3.77), greater volume of minimally invasive glaucoma surgeries (MIGS) (OR 1.68, 95% CI 1.18-2.40), and a glaucoma patient base greater than 25% (OR 2.21, 95% CI 1.09-4.48). CONCLUSIONS: For the first line treatment of POAG, laser trabeculoplasty is more likely to be preferred, over topical drops, by U.S. physicians who are relatively new in practice, who have a larger glaucoma patient base and who perform more MIGS.

2.
Eye Contact Lens ; 48(11): 449-454, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36282872

RESUMO

ABSTRACT: Contact lenses are a safe and effective method for correction of refractive error and worn by an estimated 45 million Americans. Because of the widespread availability and commercial popularity of contact lenses, it is not well appreciated by the public that contact lenses are U.S. Food and Drug Administration (FDA)-regulated medical devices. Contact lenses are marketed in numerous hard and soft materials that have been improved over decades, worn in daily or extended wear, and replaced in range of schedules from daily to yearly or longer. Lens materials and wear and care regimens have impact on the risks of contact lens-related corneal inflammatory events and microbial keratitis. This article reviews contact lens safety, with specific focus on the correction of refractive error in healthy eyes.


Assuntos
Lentes de Contato de Uso Prolongado , Lentes de Contato Hidrofílicas , Lentes de Contato , Ceratite , Erros de Refração , Humanos , Erros de Refração/terapia , Córnea , Lentes de Contato Hidrofílicas/efeitos adversos
3.
Cornea ; 41(12): 1539-1544, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36036663

RESUMO

PURPOSE: The purpose of this study was to evaluate outcomes of Descemet stripping automated endothelial keratoplasty comparing exchange with fresh intermediate-term cold storage solution after lenticule preparation versus reuse of the original solution in the Cornea Preservation Time Study. METHODS: In the Cornea Preservation Time Study, 508 donor corneas had lenticules prepared by the eye bank with fresh solution exchange (Fresh group) and 283 with reuse of the original solution (Original group). Storage time for all donors was ≤11 days. Graft success rates, central endothelial cell loss at 3 years, and frequency of positive donor rim cultures were compared between the 2 groups. RESULTS: The 3-year graft success rate (95% confidence interval) was 93.4% (90.7%-95.3%) in the Fresh group and 95.2% (91.8%-97.2%) in the Original group (adjusted hazard ratio for graft failure = 0.64, 95% confidence interval, 0.33-1.24, P = 0.19). The mean percentage endothelial cell loss was significantly greater in the Fresh group versus Original group (45% ± 22% vs. 38% ± 20%, respectively, P = 0.004). Cultures were positive in 4 (1.5%) of 267 donor rims (3 fungal and 1 bacterial) in the Fresh group and in 4 (2.5%) of 158 in the Original group ( P = 0.57). There were 2 postoperative infections in the Original group and none in the Fresh group. CONCLUSIONS: The use of the original intermediate-term cold storage solution did not reduce the 3-year graft success rate compared with exchanging with fresh solution after lenticule preparation for Descemet stripping automated endothelial keratoplasty, while the frequency of positive donor rim cultures did not significantly differ between groups.


Assuntos
Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs , Humanos , Distrofia Endotelial de Fuchs/cirurgia , Estudos de Tempo e Movimento , Córnea/cirurgia , Bancos de Olhos , Doadores de Tecidos , Endotélio Corneano
6.
Cont Lens Anterior Eye ; 44(2): 289-329, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33775381

RESUMO

The medical use of contact lenses is a solution for many complex ocular conditions, including high refractive error, irregular astigmatism, primary and secondary corneal ectasia, disfiguring disease, and ocular surface disease. The development of highly oxygen permeable soft and rigid materials has extended the suitability of contact lenses for such applications. There is consistent evidence that bandage soft contact lenses, particularly silicone hydrogel lenses, improve epithelial healing and reduce pain in persistent epithelial defects, after trauma or surgery, and in corneal dystrophies. Drug delivery applications of contact lens hold promise for improving topical therapy. Modern scleral lens practice has achieved great success for both visual rehabilitation and therapeutic applications, including those requiring retention of a tear reservoir or protection from an adverse environment. This report offers a practical and relevant summary of the current evidence for the medical use of contact lenses for all eye care professionals including optometrists, ophthalmologists, opticians, and orthoptists. Topics covered include indications for use in both acute and chronic conditions, lens selection, patient selection, wear and care regimens, and recommended aftercare schedules. Prevention, presentation, and management of complications of medical use are reviewed.


Assuntos
Lentes de Contato Hidrofílicas , Distrofias Hereditárias da Córnea , Erros de Refração , Humanos , Esclera , Acuidade Visual
7.
Optom Vis Sci ; 98(3): 182-198, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33771951

RESUMO

SIGNIFICANCE: Think Tank 2019 affirmed that the rate of infection associated with contact lenses has not changed in several decades. Also, there is a trend toward more serious infections associated with Acanthamoeba and fungi. The growing use of contact lenses in children demands our attention with surveillance and case-control studies. PURPOSE: The American Academy of Optometry (AAO) gathered researchers and key opinion leaders from around the world to discuss contact lens-associated microbial keratitis at the 2019 AAO Annual Meeting. METHODS: Experts presented within four sessions. Session 1 covered the epidemiology of microbial keratitis, pathogenesis of Pseudomonas aeruginosa, and the role of lens care systems and storage cases in corneal disease. Session 2 covered nonbacterial forms of keratitis in contact lens wearers. Session 3 covered future needs, challenges, and research questions in relation to microbial keratitis in youth and myopia control, microbiome, antimicrobial surfaces, and genetic susceptibility. Session 4 covered compliance and communication imperatives. RESULTS: The absolute rate of microbial keratitis has remained very consistent for three decades despite new technologies, and extended wear significantly increases the risk. Improved oxygen delivery afforded by silicone hydrogel lenses has not impacted the rates, and although the introduction of daily disposable lenses has minimized the risk of severe disease, there is no consistent evidence that they have altered the overall rate of microbial keratitis. Overnight orthokeratology lenses may increase the risk of microbial keratitis, especially secondary to Acanthamoeba, in children. Compliance remains a concern and a significant risk factor for disease. New insights into host microbiome and genetic susceptibility may uncover new theories. More studies such as case-control designs suited for rare diseases and registries are needed. CONCLUSIONS: The first annual AAO Think Tank acknowledged that the risk of microbial keratitis has not decreased over decades, despite innovation. Important questions and research directions remain.


Assuntos
Ceratite por Acanthamoeba/epidemiologia , Lentes de Contato/efeitos adversos , Infecções Oculares Bacterianas/epidemiologia , Infecções Oculares Fúngicas/epidemiologia , Infecções Oculares Parasitárias/epidemiologia , Ceratite/epidemiologia , Optometria/organização & administração , Academias e Institutos , Ceratite por Acanthamoeba/parasitologia , Estudos Epidemiológicos , Infecções Oculares Bacterianas/microbiologia , Infecções Oculares Fúngicas/microbiologia , Infecções Oculares Parasitárias/parasitologia , Humanos , Incidência , Ceratite/microbiologia , Fatores de Risco , Estados Unidos/epidemiologia
8.
Commun Biol ; 4(1): 266, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33649486

RESUMO

Keratoconus is characterised by reduced rigidity of the cornea with distortion and focal thinning that causes blurred vision, however, the pathogenetic mechanisms are unknown. It can lead to severe visual morbidity in children and young adults and is a common indication for corneal transplantation worldwide. Here we report the first large scale genome-wide association study of keratoconus including 4,669 cases and 116,547 controls. We have identified significant association with 36 genomic loci that, for the first time, implicate both dysregulation of corneal collagen matrix integrity and cell differentiation pathways as primary disease-causing mechanisms. The results also suggest pleiotropy, with some disease mechanisms shared with other corneal diseases, such as Fuchs endothelial corneal dystrophy. The common variants associated with keratoconus explain 12.5% of the genetic variance, which shows potential for the future development of a diagnostic test to detect susceptibility to disease.


Assuntos
Diferenciação Celular/genética , Colágeno/metabolismo , Matriz Extracelular/metabolismo , Loci Gênicos , Ceratocone/genética , Polimorfismo de Nucleotídeo Único , Austrália/epidemiologia , Estudos de Casos e Controles , Europa (Continente)/epidemiologia , Matriz Extracelular/patologia , Predisposição Genética para Doença , Estudo de Associação Genômica Ampla , Humanos , Ceratocone/diagnóstico , Ceratocone/etnologia , Ceratocone/metabolismo , Fenótipo , Medição de Risco , Fatores de Risco
9.
JAMA Ophthalmol ; 139(2): 191-197, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33355637

RESUMO

Importance: A new analytic method can evaluate factors of interest associated with graft failure after Descemet stripping automated endothelial keratoplasty (DSAEK) or more generally in any ophthalmic surgical setting with a time-to-event outcome. Objective: To reanalyze types of intraoperative complications associated with DSAEK graft failure in the Cornea Preservation Time Study using random survival forests. Design, Setting, and Participants: This cohort study, initially conceived in April 2019, used a prediction model to conduct a post hoc secondary analysis of data collected in a multicenter, double-masked, randomized clinical trial. Forty US clinical sites with 70 surgeons participated, with donor corneas provided by 23 US eye banks. The study included 1090 participants, representing 1330 eyes, undergoing DSAEK for Fuchs dystrophy (1255 eyes [94.4%]) or pseudophakic or aphakic corneal edema (75 eyes [5.6%]). Enrollment occurred between April 16, 2012, and February 20, 2014, and follow-up ended June 5, 2017. Statistical analysis was performed from July 10, 2019, to May 29, 2020. Intervention: Descemet stripping automated endothelial keratoplasty with random assignment of a donor cornea with preservation time of 7 days or less or 8 to 14 days. Main Outcomes and Measures: Ranked variable importance for intraoperative complications among 50 donor, recipient, and eye bank variables and restricted mean survival time through 47 months (1434 days) after DSAEK were examined. Random survival forests, a nonparametric method (with less restrictive model assumptions) that is far more flexible in its ability to model nonlinear effects and interactions, was used to analyze the data. Results: This study included 1090 participants (663 women [60.8%]; median age, 70 years [range, 42-90 years]), representing 1330 eyes. Random survival forests ranked a DSAEK intraoperative complication as the third most predictive factor of graft failure, after surgeon and eye bank, in the final model with 5 predictors. In the first 47 months after DSAEK, the estimated mean difference in restricted mean survival time for grafts that experienced a DSAEK intraoperative complication vs those that did not was -227 days (99% CI, -352 to -70 days) based on the final RSF model. Conclusions and Relevance: These findings, while post hoc, support the hypothesis that random survival forests allow for an improved analytic approach for identifying factors predictive of graft failure and for obtaining adjusted graft survival estimates. Random survival forests offer the opportunity to guide the development of future population-based cohort ophthalmic surgical studies, establishing definitive factors for procedural success.


Assuntos
Edema da Córnea/cirurgia , Técnicas de Apoio para a Decisão , Lâmina Limitante Posterior/cirurgia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/efeitos adversos , Endotélio Corneano/transplante , Distrofia Endotelial de Fuchs/cirurgia , Sobrevivência de Enxerto , Complicações Intraoperatórias/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Edema da Córnea/diagnóstico , Método Duplo-Cego , Feminino , Distrofia Endotelial de Fuchs/diagnóstico , Humanos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Falha de Tratamento , Estados Unidos
10.
Cont Lens Anterior Eye ; 44(1): 108-114, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33160831

RESUMO

PURPOSE: To report three cases of acute corneal edema occurring decades after penetrating keratoplasty (PK) for keratoconus in eyes wearing scleral contact lenses (ScCLs) with previously clear corneal grafts. METHODS: Retrospective chart review of three ScCL wearers presenting for sudden onset pain and blurred vision. Data extracted included clinical presentation, year and reason for PK, ocular medications and comorbidities, contact lens wearing history, results of any ancillary testing available including corneal topography, anterior segment optical coherence tomography (OCT), and specular microscopy surrounding the event, treatment and outcomes of intervention. The number of PK eyes fit with ScCLs in the author's practice was determined to estimate the prevalence of this event. RESULTS: The three patients each had a longstanding PK for keratoconus performed between 33-35 years prior to presentation and recurrent ectasia. Each patient presented with an acute, painful eye and reduced vision either 3 days, 4 months or 9 years after refitting into ScCLs. Each eye had well demarcated focal microcystic epithelial and stromal edema within the graft and crossing the wound margin onto the host cornea. Although a definitive break or detachment of Descemet's membrane was not visualized, the presentations suggest these were episodes of acute hydrops. CONCLUSIONS: Longstanding PKs with recurrent ectasia and acute focal edema suggestive of corneal hydrops is demonstrated in this case series of ScCL wearers. Although similar events have occurred as part of the natural history of post-PK corneas for keratoconus, the proximity of ScCL refitting to two of the events suggests some association.


Assuntos
Lentes de Contato , Edema da Córnea , Ceratocone , Lentes de Contato/efeitos adversos , Córnea , Edema da Córnea/diagnóstico , Edema da Córnea/etiologia , Edema , Humanos , Ceratocone/diagnóstico , Ceratocone/cirurgia , Ceratoplastia Penetrante/efeitos adversos , Estudos Retrospectivos
12.
Eye Contact Lens ; 46(6): 327-328, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33119983
13.
Transl Vis Sci Technol ; 9(5): 25, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32821497

RESUMO

Purpose: Correlate climate, weather parameters, and environmental exposures with the severity of symptoms and signs of dry eye disease (DED) in Dry Eye Assessment and Management (DREAM) study participants. Methods: Participants from five distinct climates completed the Ocular Surface Disease Index (OSDI) and were examined for corneal and conjunctival staining, tear breakup time (TBUT), and Schirmer's testing at baseline, 3, 6, and 12 months. Climate, weather parameters, and pollutants including ozone (O3), carbon monoxide (CO), nitrous oxides (NO2, NOx, NOy), sulfur dioxide (SO2), particulate matter, and optical depth were obtained from governmental databases. Multivariate analysis and partial correlation coefficients (ρ) were used to assess associations, adjusted for age, sex, and the presence of Sjögren disease. Results: Among 535 participants, 81% were female and mean age was 58 years. Participants from the Mediterranean climate demonstrated better corneal fluorescein staining, better TBUT, and higher Schirmer's test scores throughout the calendar year (each P < 0.0001). Greater corneal fluorescein staining was associated with lower humidity (P < 0.0038). TBUT measurements positively correlated with temperature, humidity, and dewpoint and inversely correlated with NO2 levels (P < 0.0038). Paradoxically, some airborne pollutants were associated with less severe signs of dry eye (P < 0.0038). Windspeed was not correlated with signs of DED, and OSDI scores did not correlate with individual environmental exposures. Conclusions: Dry eye signs differed between climates and local humidity levels. With the exception of NO2, airborne pollutants were not associated with detrimental dry eye features. Translational Relevance: These results support limiting dry air exposure for patients with DED.


Assuntos
Síndromes do Olho Seco , Túnica Conjuntiva , Córnea , Síndromes do Olho Seco/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença , Lágrimas
14.
Optom Vis Sci ; 97(8): 565-572, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32769842

RESUMO

SIGNIFICANCE: Lotrafilcon B lenses packaged in and cared for with block copolymer-containing (polyoxyethylene-polyoxybutylene; EOBO) lens care solutions resulted in lower cholesterol extraction than each of the habitual silicone hydrogel lens/multipurpose solution (MPS) regimens tested. PURPOSE: This study aimed to compare the extracted cholesterol of lotrafilcon B lenses packaged in and cared for with EOBO-containing lens care solutions with the extracted cholesterol of habitual silicone hydrogel lenses cared for with MPS not containing EOBO. METHODS: In this prospective, randomized, observer-masked parallel study, habitual wearers of senofilcon C, senofilcon A, comfilcon A, and samfilcon A contact lenses using a non-EOBO MPS were randomized 1:1 to lotrafilcon B lenses packaged in and cared for with EOBO-containing solutions or to their habitual lenses and MPS. Subjects randomized to lotrafilcon B were further randomized to one of two EOBO-containing lens care solutions, OPTI-FREE PUREMOIST or CLEAR CARE PLUS with HydraGlyde (Alcon Laboratories, Inc., Fort Worth, TX). A subset of right eye lenses was collected after wear, and total cholesterol was extracted and measured using a fluorometric enzymatic assay. RESULTS: Of 143 lenses analyzed, 95 were from subjects randomized to their habitual lenses/MPS and 48 to lotrafilcon B + EOBO lenses plus CLEAR CARE PLUS with HydraGlyde or OPTI-FREE PUREMOIST. The mean amounts of cholesterol extracted from lotrafilcon B + EOBO lenses cared for with CLEAR CARE PLUS with HydraGlyde (0.28 ± 0.18 µg/lens) and OPTI-FREE PUREMOIST (0.28 ± 0.48 µg/lens) were significantly lower than those extracted from senofilcon C (4.18 ± 3.25 µg/lens), senofilcon A (2.19 ± 2.69 µg/lens), comfilcon A (2.17 ± 1.47 µg/lens), and samfilcon A (2.07 ± 1.48 µg/lens) lenses used with MPS (P < .0001 each). CONCLUSIONS: Cholesterol sorption was significantly lower in wearers of lotrafilcon B lenses cared for with polyoxyethylene-polyoxybutylene-containing lens care solutions than in users of habitual silicone hydrogel lenses cared for with non-polyoxyethylene-polyoxybutylene MPS.


Assuntos
Colesterol/análise , Soluções para Lentes de Contato/química , Lentes de Contato Hidrofílicas , Hidrogéis/química , Elastômeros de Silicone/química , Silicones/química , Lágrimas/química , Adulto , Alcenos , Método Duplo-Cego , Feminino , Fluorometria , Humanos , Masculino , Polietilenoglicóis , Embalagem de Produtos , Estudos Prospectivos
15.
Optom Vis Sci ; 97(8): 544-548, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32769840

RESUMO

SIGNIFICANCE: Standardized guidelines that are clinically practical are needed to assist the prescriber in minimizing the risk of conveying infection through multiuse diagnostic contact lens use and reuse.Contact lens prescribers face the specter of transferring potential pathogens from one patient to another when reusing diagnostic (trial) contact lenses on multiple patients because infectious organisms have been recovered from worn contact lenses, although there is no evidence of transmission through this mechanism. These pathogens can be introduced into the system from one patient to another, or they may be introduced by clinician lens handling, storage, or both. These pathogens can cause acute or chronic systemic or ocular infection that can lead to significant morbidity (temporary or permanent) that includes vision loss.


Assuntos
Soluções para Lentes de Contato/uso terapêutico , Lentes de Contato Hidrofílicas/normas , Desinfecção/métodos , Contaminação de Equipamentos/prevenção & controle , Higiene/normas , Prescrições/normas , Manejo de Espécimes/métodos , Lentes de Contato Hidrofílicas/microbiologia , Transmissão de Doença Infecciosa/prevenção & controle , Infecções Oculares/prevenção & controle , Desinfecção das Mãos , Humanos , Procedimentos Ortoceratológicos
16.
Cont Lens Anterior Eye ; 43(3): 285-297, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32278644

RESUMO

Frequent replacement contact lenses made from the etafilcon A hydrogel lens material were introduced onto the market over 30 years ago, and etafilcon A remains the most widely used hydrogel lens material today. Although the prescribing of silicone hydrogel lenses is increasing, millions of lens wearers globally have been wearing hydrogel lenses for many years and exhibit a physiologically-stable 'quiet eye', with a low profile of adverse events. Hydrogel lenses are demonstrated to maintain a low inflammatory response and infection risk profile during daily wear, which in the case of etafilcon A, may be related to its low modulus, and the naturally-protective, anti-microbial, non-denatured lysozyme absorbed into the lens from the tear fluid. Although improved corneal physiology from decreased hypoxia with silicone hydrogel lenses is well accepted, equivalent levels of corneal oxygenation are maintained during daily wear of low to medium powered hydrogel lenses, which do not impede the daily corneal de-swelling process, and do not induce clinically significant changes in ocular health. Therefore, hydrogel lenses remain an important alternative for daily wear in modern contact lens practice.


Assuntos
Lentes de Contato de Uso Prolongado , Córnea/metabolismo , Erros de Refração/terapia , Lágrimas/metabolismo , Visão Ocular/fisiologia , Humanos , Erros de Refração/metabolismo , Erros de Refração/fisiopatologia
17.
J Cataract Refract Surg ; 46(3): 355-359, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32050222

RESUMO

PURPOSE: To determine whether intracameral moxifloxacin 500 µg is noninferior to 250 µg for central endothelial cell loss (ECL) after phacoemulsification. SETTING: Aravind Eye Care System. DESIGN: Prospective masked randomized study. METHODS: Eyes with bilateral nuclear cataracts, central endothelial cell density (ECD) of more than 2000 cells/mm, and ECD not differing between eyes by more than 200 cells/mm underwent phacoemulsification at least 14 days apart. Intraoperatively, the first eye was randomized to receive either a 500 or 250 µg dose of moxifloxacin intracamerally and received the other dose for the second-eye surgery. Postoperative course was monitored at 1 day, 1 week, 1 month, and 3 months. Preoperative and 30-day and 90-day postoperative central ECD was determined by a reading center for a masked analysis of ECL at 3 months postoperatively. RESULTS: Fifty eyes of 25 patients (aged 48 to 69 years) underwent uneventful surgery and had normal postoperative courses. The point estimate (PE) and 95% CI for the mean difference in % ECL between the 500 µg and 250 µg doses at 3 months postoperatively was 0.8% (-5.8%, 7.4%). Upon identifying and removing 2 outliers, noninferiority was proven with a mean difference of the PE, -2.2% (CI, -6.5%, 2.1%). CONCLUSIONS: Clinical and corneal endothelial cell were comparable in this study population for the 250 µg and 500 µg doses of intracameral moxifloxacin. Both doses were well tolerated clinically, supporting the use of the higher dose for improved antimicrobial coverage for the prevention of postoperative endophthalmitis.


Assuntos
Antibacterianos/toxicidade , Endoftalmite/prevenção & controle , Endotélio Corneano/efeitos dos fármacos , Moxifloxacina/toxicidade , Facoemulsificação , Complicações Pós-Operatórias/prevenção & controle , Idoso , Câmara Anterior/efeitos dos fármacos , Antibacterianos/administração & dosagem , Antibioticoprofilaxia , Perda de Células Endoteliais da Córnea/induzido quimicamente , Perda de Células Endoteliais da Córnea/diagnóstico , Método Duplo-Cego , Feminino , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Moxifloxacina/administração & dosagem , Nível de Efeito Adverso não Observado , Estudos Prospectivos , Acuidade Visual
19.
Cornea ; 38(9): 1069-1076, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31180926

RESUMO

PURPOSE: To identify donor and recipient factors, including eye bank tissue observations, predictive of operative complications in the Cornea Preservation Time Study. METHODS: One thousand three hundred thirty study eyes undergoing Descemet stripping automated endothelial keratoplasty for Fuchs dystrophy or pseudophakic/aphakic corneal edema were randomized to receive a donor cornea with preservation time (PT) of 0 to 7 days (N = 675) or 8 to 14 days (N = 655). Donor factors included demographics, prelamellar corneal and postlamellar lenticule dissection thickness, central endothelial cell density, and tissue processing time. Recipient factors included demographics, intraocular pressure, and glaucoma medications or surgery (trabeculectomy, laser trabeculoplasty). Eye bank observations included donor tissue folds, pleomorphism/polymegethism, and endothelial cell abnormalities. Possible tissue-related operative complications were recorded including difficult donor lenticule unfolding and positioning. Multivariable logistic regression with backward selection was used to identify statistically significant (P < 0.01) associations between factors and operative complications. RESULTS: The only factor predictive of operative complications [58 (4.4%) of 1330 surgeries] was prelamellar dissection donor corneal thickness (P = 0.002). For every 50 µm of donor corneal thickness prior to lamellar dissection, operative complication odds increased by 40% (odds ratio [99% confidence interval (CI)]: 1.40 [1.06-1.83]) adjusting for PT and whether the epithelium was on or off. The estimated mean prelamellar dissection donor corneal thickness for PT 0 to 7 days was 537 µm (99% CI: 516 µm-558 µm) compared with 567 µm (99% CI: 546 µm-588 µm) for PT 8 to 14 days (P < 0.001). CONCLUSIONS: Thicker donor tissue (prelamellar dissection) is associated with operative complications and should be considered in tissue selection for Descemet stripping automated endothelial keratoplasty lenticule preparation.


Assuntos
Edema da Córnea/cirurgia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Distrofia Endotelial de Fuchs/cirurgia , Adolescente , Adulto , Idoso , Criança , Córnea/patologia , Feminino , Humanos , Complicações Intraoperatórias/etiologia , Masculino , Pessoa de Meia-Idade , Razão de Chances , Adulto Jovem
20.
Optom Vis Sci ; 96(6): 387-396, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31116166

RESUMO

SIGNIFICANCE: Identification of the association of specific signs of dry eye disease with specific visual function deficits may allow for more targeted approaches to treatment. PURPOSE: The purpose of this study was to explore the association of dry eye signs and symptoms with visual acuity (VA) and contrast sensitivity in the Dry Eye Assessment and Management study. METHODS: Baseline data from participants in the Dry Eye Assessment and Management study were used in this secondary cross-sectional analysis. Standardized procedures were used to obtain results on the Ocular Surface Disease Index (OSDI), high-contrast logMAR VA, contrast sensitivity, tear film debris, tear breakup time (TBUT), corneal fluorescein staining, meibomian gland evaluation, conjunctival lissamine green staining, and Schirmer test scores. Generalized linear models that included age, refractive error status, and cataract status were used to assess the association between VA and contrast sensitivity with OSDI score and each dry eye sign. The Hochberg procedure was used to account for multiple comparisons. RESULTS: Among 487 participants (974 eyes), worse VA was associated with worse mean score on the OSDI vision subscale (39.4 for VA 20/32 or worse vs. 32.4 for VA 20/16 or better; adjusted linear trend, P = .02); scores were not associated with contrast sensitivity. Severe meibomian gland plugging and abnormal secretions were associated with worse mean log contrast sensitivity (1.48 for severe vs. 1.54 for not plugged [P = .04] and 1.49 for obstructed vs. 1.57 for clear [P = .002], respectively). Longer TBUT was associated with better mean log contrast sensitivity (1.57 for TBUT >5 seconds and 1.51 for TBUT ≤2 seconds, P < .0001). CONCLUSIONS: Worse VA rather than worse contrast sensitivity drives vision-related symptoms in dry eye. Greater tear film instability was associated with worse contrast sensitivity.


Assuntos
Sensibilidades de Contraste/fisiologia , Síndromes do Olho Seco/fisiopatologia , Acuidade Visual/fisiologia , Adulto , Idoso , Estudos Transversais , Ácidos Docosa-Hexaenoicos/uso terapêutico , Método Duplo-Cego , Combinação de Medicamentos , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/tratamento farmacológico , Ácido Eicosapentaenoico/uso terapêutico , Feminino , Humanos , Masculino , Glândulas Tarsais/fisiopatologia , Pessoa de Meia-Idade , Lágrimas/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...