Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 130(22): 221802, 2023 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-37327426

RESUMO

We present the results of a search for heavy QCD axions performed by the ArgoNeuT experiment at Fermilab. We search for heavy axions produced in the NuMI neutrino beam target and absorber decaying into dimuon pairs, which can be identified using the unique capabilities of ArgoNeuT and the MINOS near detector. This decay channel is motivated by a broad class of heavy QCD axion models that address the strong CP and axion quality problems with axion masses above the dimuon threshold. We obtain new constraints at a 95% confidence level for heavy axions in the previously unexplored mass range of 0.2-0.9 GeV, for axion decay constants around tens of TeV.


Assuntos
Tetranitrato de Pentaeritritol , Argônio
2.
Phys Rev Lett ; 129(2): 021801, 2022 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-35867467

RESUMO

We report the first results of a search for leptophobic dark matter (DM) from the Coherent-CAPTAIN-Mills (CCM) liquid argon (LAr) detector. An engineering run with 120 photomultiplier tubes (PMTs) and 17.9×10^{20} protons on target (POT) was performed in fall 2019 to study the characteristics of the CCM detector. The operation of this 10-ton detector was strictly light based with a threshold of 50 keV and used coherent elastic scattering off argon nuclei to detect DM. Despite only 1.5 months of accumulated luminosity, contaminated LAr, and nonoptimized shielding, CCM's first engineering run has already achieved sensitivity to previously unexplored parameter space of light dark matter models with a baryonic vector portal. With an expected background of 115 005 events, we observe 115 005+16.5 events which is compatible with background expectations. For a benchmark mediator-to-DM mass ratio of m_{V_{B}}/m_{χ}=2.1, DM masses within the range 9 MeV≲m_{χ}≲50 MeV are excluded at 90% C. L. in the leptophobic model after applying the Feldman-Cousins test statistic. CCM's upgraded run with 200 PMTs, filtered LAr, improved shielding, and 10 times more POT will be able to exclude the remaining thermal relic density parameter space of this model, as well as probe new parameter space of other leptophobic DM models.

3.
Phys Rev Lett ; 127(12): 121801, 2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34597110

RESUMO

A search for heavy neutral leptons has been performed with the ArgoNeuT detector exposed to the NuMI neutrino beam at Fermilab. We search for the decay signature N→νµ^{+}µ^{-}, considering decays occurring both inside ArgoNeuT and in the upstream cavern. In the data, corresponding to an exposure to 1.25×10^{20} POT, zero passing events are observed consistent with the expected background. This measurement leads to a new constraint at 90% confidence level on the mixing angle |U_{τN}|^{2} of tau-coupled Dirac heavy neutral leptons with masses m_{N}=280-970 MeV, assuming |U_{eN}|^{2}=|U_{µN}|^{2}=0.

4.
Phys Rev Lett ; 124(13): 131801, 2020 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-32302167

RESUMO

A search for millicharged particles, a simple extension of the standard model, has been performed with the ArgoNeuT detector exposed to the Neutrinos at the Main Injector beam at Fermilab. The ArgoNeuT liquid argon time projection chamber detector enables a search for millicharged particles through the detection of visible electron recoils. We search for an event signature with two soft hits (MeV-scale energy depositions) aligned with the upstream target. For an exposure of the detector of 1.0×10^{20} protons on target, one candidate event has been observed, compatible with the expected background. This search is sensitive to millicharged particles with charges between 10^{-3}e and 10^{-1}e and with masses in the range from 0.1 to 3 GeV. This measurement provides leading constraints on millicharged particles in this large unexplored parameter space region.

5.
Phys Rev Lett ; 113(26): 261801, 2014 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-25615307

RESUMO

We report on the first cross section measurements for charged current coherent pion production by neutrinos and antineutrinos on argon. These measurements are performed using the ArgoNeuT detector exposed to the NuMI beam at Fermilab. The cross sections are measured to be 2.6(-1.0)(+1.2)(stat)(-0.4)(+0.3)(syst)×10(-38) cm(2)/Ar for neutrinos at a mean energy of 9.6 GeV and 5.5(-2.1)(+2.6)(stat)(-0.7)(+0.6)(syst)×10(-39) cm(2)/Ar for antineutrinos at a mean energy of 3.6 GeV.

6.
Phys Rev Lett ; 108(16): 161802, 2012 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-22680709

RESUMO

The ArgoNeuT Collaboration presents the first measurements of inclusive muon neutrino charged current differential cross sections on argon. Obtained in the NuMI neutrino beam line at Fermilab, the flux-integrated results are reported in terms of outgoing muon angle and momentum. The data are consistent with the Monte Carlo expectation across the full range of kinematics sampled, 0°<θ(µ)<36° and 0

7.
J Res Natl Inst Stand Technol ; 110(3): 173-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308117

RESUMO

For highly sensitive magnetic measurements, e.g., a measurement of the neutron electric dipole moment (EDM), the magnetic field has to be stable in time on a level below picoTesla. One of several measures we employ to achieve this uses an external field coil system which can stabilize the ambient external field at a predefined value. Here we report on the construction and characterization of such a system in the magnetic test facility at PSI. The system actively stabilizes the field along the axis of the EDM experiment by means of four coils in a Helmholtz-like configuration. Additional coils serve to compensate for transverse ambient field components. Because of the long integration times in the EDM experiment (about 100 s or more) only slow disturbances have to be corrected for. The performance of the system has been measured using static and moving magnetic sources and suppression factors in excess of 200 have been observed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...