Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 132: 173-183, 2017 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-27744176

RESUMO

Fluoroquinolones are the drugs of choice in the prevention of bacterial infections after transrectal ultrasound guided prostate biopsy. In order to improve assessment of antibacterial efficacy in the target tissue a simple, selective, rapid and robust HPLC-ESI-MS/MS method for the determination of levofloxacin and ciprofloxacin concentrations in human prostate bioptates was developed and validated. Preparation procedure for prostate samples (10mg) was carried out using homogenization and filtration steps. Analyses were performed within 3.5min using RP C18 column in the isocratic elution mode with mobile phase composed of a mixture of 0.1% formic acid aqueous solution and 0.1% formic acid methanol solution (v/v; 79:21). The method was linear between 0.3µg/g and 15µg/g for levofloxacin and ciprofloxacin with coefficient of correlation (r) ≥0.999. The limit of detection and the limit of quantification for levofloxacin were 0.06µg/g and 0.2µg/g and for ciprofloxacin were 0.04µg/g and 0.13µg/g, respectively. Average concentrations (±SD) of levofloxacin and ciprofloxacin obtained from patients tissue were 5.4±2.2µg/g and 3.9±1.5µg/g, respectively. Additionally, during validation procedure a novel, experimental design approach was applied for the robustness study. For evaluation of analytical method robustness, Plackett-Burman design was employed and for sample preparation method robustness Fractional Factorial design was used. The developed and validated method was successfully applied to examine prostate tissue samples obtained from patients enrolled into a clinical study. Up to now, there has been no other HPLC-ESI-MS/MS method reported for the simultaneous determination of levofloxacin and ciprofloxacin in human prostatic tissue.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Ciprofloxacina/análise , Ciprofloxacina/farmacocinética , Levofloxacino/análise , Levofloxacino/farmacocinética , Próstata/efeitos dos fármacos , Espectrometria de Massas em Tandem/métodos , Antibacterianos/análise , Calibragem , Fluoroquinolonas/análise , Humanos , Limite de Detecção , Masculino , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray , Temperatura
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1029-1030: 48-59, 2016 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-27423043

RESUMO

Fluoroquinolones are considered as gold standard for the prevention of bacterial infections after transrectal ultrasound guided prostate biopsy. However, recent studies reported that fluoroquinolone- resistant bacterial strains are responsible for gradually increasing number of infections after transrectal prostate biopsy. In daily clinical practice, antibacterial efficacy is evaluated only in vitro, by measuring the reaction of bacteria with an antimicrobial agent in culture media (i.e. calculation of minimal inhibitory concentration). Such approach, however, has no relation to the treated tissue characteristics and might be highly misleading. Thus, the objective of this study was to develop, with the use of Design of Experiments approach, a reliable, specific and sensitive ultra-high performance liquid chromatography- diode array detection method for the quantitative analysis of levofloxacin in plasma and prostate tissue samples obtained from patients undergoing prostate biopsy. Moreover, correlation study between concentrations observed in plasma samples vs prostatic tissue samples was performed, resulting in better understanding, evaluation and optimization of the fluoroquinolone-based antimicrobial prophylaxis during transrectal ultrasound guided prostate biopsy. Box-Behnken design was employed to optimize chromatographic conditions of the isocratic elution program in order to obtain desirable retention time, peak symmetry and resolution of levofloxacine and ciprofloxacine (internal standard) peaks. Fractional Factorial design 2(4-1) with four center points was used for screening of significant factors affecting levofloxacin extraction from the prostatic tissue. Due to the limited number of tissue samples the prostatic sample preparation procedure was further optimized using Central Composite design. Design of Experiments approach was also utilized for evaluation of parameter robustness. The method was found linear over the range of 0.030-10µg/mL for human plasma and 0.300-30µg/g for human prostate tissue samples. The intra-day and inter-day variability for levofloxacine from both plasma and prostate samples were less than 10%, with accuracies between 93 and 108% of the nominal values. The limit of detection and the limit of quantification for human plasma were 0.01µg/mL and 0.03µg/mL, respectively. For the prostate tissue, the limit of detection and the limit of quantification were 0.1µg/g and 0.3µg/g, respectively. The average recoveries of levofloxacin were in the range from 99 to 106%. Also, the method fulfills requirements of robustness what was determined and proved by Design of Experiments. The developed method was successfully applied to examine prostate tissue and plasma samples from 140 hospitalized patients enrolled into the clinical study, 12h after oral administration of LVF at a dose of 500mg. The mean (±SD) LVF concentration in prostate was 6.22±3.52µg/g and in plasma 2.54±1.14µg/mL. Due to simplicity of the method and relative small amount of sample needed for the assay, the method can be applied in clinical practice for monitoring of LVF concentrations in plasma and prostate gland.


Assuntos
Antibacterianos/farmacocinética , Infecções Bacterianas/prevenção & controle , Cromatografia Líquida de Alta Pressão/métodos , Levofloxacino/farmacocinética , Próstata/patologia , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/sangue , Infecções Bacterianas/etiologia , Endossonografia/efeitos adversos , Humanos , Biópsia Guiada por Imagem/efeitos adversos , Levofloxacino/sangue , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Próstata/metabolismo , Próstata/microbiologia
SELEÇÃO DE REFERÊNCIAS