Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Invest Ophthalmol Vis Sci ; 62(6): 20, 2021 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-34010957

RESUMO

Purpose: In diabetic subjects, early visual functional alterations such as color vision deficiencies (CVDs) are known to precede clinically apparent diabetic retinopathy. Prominent photoreceptor outer segment degeneration and an increase in the number of retinal dual cones (co-expressing S- and M-opsins simultaneously) have been described in diabetic rat models, suggesting a connection with the development of CVDs. As cone opsin expression is controlled by thyroid hormones, we investigated the diabetic retina in association with thyroid hormone alterations. Methods: In rat models of type 1 and 2 diabetes, dual cones were labeled by immunohistochemistry, and their numbers were analyzed in relation to free triiodothyronine (fT3) and free thyroxine (fT4) levels. Quantification of dual cones was also performed in human postmortem retinas. Additionally, a cross-sectional case-control study was performed where thyroid hormone levels were measured and color vision was assessed with Lanthony desaturated D15 discs. Results: A higher number of dual cones was detectable in diabetic rats, correlating with fT4 levels. Dual cones were also present in postmortem human retinas, with higher numbers in the three diabetic retinas. As expected, age was strongly associated with CVDs in human patients, and the presence of diabetes also increased the risk. However, the current study failed to detect any effect of thyroid hormones on the development of CVDs. Conclusions: Our results point toward the involvement of thyroid homeostasis in the opsin expression changes in diabetic rats and human samples. The evaluation of the possible clinical consequences warrants further research.


Assuntos
Diabetes Mellitus Experimental/sangue , Retinopatia Diabética/sangue , Células Fotorreceptoras Retinianas Cones/patologia , Hormônios Tireóideos/sangue , Adulto , Idoso , Animais , Glicemia/metabolismo , Estudos de Casos e Controles , Visão de Cores/fisiologia , Opsinas dos Cones/metabolismo , Estudos Transversais , Diabetes Mellitus Experimental/patologia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/patologia , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/patologia , Retinopatia Diabética/patologia , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Ratos , Ratos Sprague-Dawley , Ratos Zucker , Células Fotorreceptoras Retinianas Cones/metabolismo , Adulto Jovem
2.
J Biophotonics ; 9(5): 478-89, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27159849

RESUMO

Over the past two decades a significant number of OCT segmentation approaches have been proposed in the literature. Each methodology has been conceived for and/or evaluated using specific datasets that do not reflect the complexities of the majority of widely available retinal features observed in clinical settings. In addition, there does not exist an appropriate OCT dataset with ground truth that reflects the realities of everyday retinal features observed in clinical settings. While the need for unbiased performance evaluation of automated segmentation algorithms is obvious, the validation process of segmentation algorithms have been usually performed by comparing with manual labelings from each study and there has been a lack of common ground truth. Therefore, a performance comparison of different algorithms using the same ground truth has never been performed. This paper reviews research-oriented tools for automated segmentation of the retinal tissue on OCT images. It also evaluates and compares the performance of these software tools with a common ground truth.


Assuntos
Retina/diagnóstico por imagem , Software , Tomografia de Coerência Óptica , Algoritmos , Humanos , Reprodutibilidade dos Testes
3.
Exp Dermatol ; 25(7): 519-25, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26910301

RESUMO

Artificial UV irradiation of murine skin is a frequently used method for testing photosensitivity, study carcinogenesis and photoprotective effects of different compounds. However, doses of UV radiation and mouse strains used in experiments vary greatly. The genetic background of mice may influence the photosensitivity as melanin content, pigmentation and hair cycle parameters are dissimilar. Doses of UV are often expressed in relation to the minimal erythema dose (MED) that was not necessarily determined for the given strain. We set out to standardize the method of measuring photosensitivity in three commonly used mouse strains, C57BL/6N, Balb/c and SKH-1. We found that MED may not be determined for some strains as erythema development in mice with diverse genotypes differs greatly. We measured the oedema response in vivo and ex vivo by using OCT. Given the strain-specific variability of erythema, we introduced Clinically Relevant Dose (CRD) as a new term to replace MED in experiments, to describe the lowest dose that triggers a perceptible skin reaction in mice. Not only the CRD but the proportion of erythema and oedema were different in strains examined. C57BL/6N mice display skin reactions at the lowest UVB dose, while SKH-1 hairless mice show changes, mostly oedema, after higher doses of UVB. The cellular composition and skin thickness were examined by histopathology. IL-1beta and IL-6 levels in skin correlated with the increasing doses of UVB. Despite the variations in the degree of erythema and oedema, no major differences in cytokine expressions were seen among various strains of mice.


Assuntos
Modelos Animais de Doenças , Transtornos de Fotossensibilidade/genética , Pele/efeitos da radiação , Raios Ultravioleta/efeitos adversos , Animais , Edema/etiologia , Eritema/etiologia , Feminino , Interleucina-1beta/metabolismo , Interleucina-6/metabolismo , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Pele/metabolismo , Pele/patologia
4.
PLoS One ; 10(11): e0143711, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26619298

RESUMO

PURPOSE: To assess the differences in texture descriptors and optical properties of retinal tissue layers in patients with multiple sclerosis (MS) and to evaluate their usefulness in the detection of neurodegenerative changes using optical coherence tomography (OCT) image segmentation. PATIENTS AND METHODS: 38 patients with MS were examined using Stratus OCT. The raw macular OCT data were exported and processed using OCTRIMA software. The enrolled eyes were divided into two groups, based on the presence of optic neuritis (ON) in the history (MSON+ group, n = 36 and MSON- group, n = 31). Data of 29 eyes of 24 healthy subjects (H) were used as controls. A total of seven intraretinal layers were segmented and thickness as well as optical parameters such as contrast, fractal dimension, layer index and total reflectance were measured. Mixed-model ANOVA analysis was used for statistical comparisons. RESULTS: Significant thinning of the retinal nerve fiber layer (RNFL), ganglion cell/inner plexiform layer complex (GCL+IPL) and ganglion cell complex (GCC, RNFL+GCL+IPL) was observed between study groups in all comparisons. Significant difference was found in contrast in the RNFL, GCL+IPL, GCC, inner nuclear layer (INL) and outer plexiform layer when comparing MSON+ to the other groups. Higher fractal dimension values were observed in GCL+IPL and INL layers when comparing H vs. MSON+ groups. A significant difference was found in layer index in the RNFL, GCL+IPL and GCC layers in all comparisons. A significant difference was observed in total reflectance in the RNFL, GCL+IPL and GCC layers between the three examination groups. CONCLUSION: Texture and optical properties of the retinal tissue undergo pronounced changes in MS even without optic neuritis. Our results may help to further improve the diagnostic efficacy of OCT in MS and neurodegeneration.


Assuntos
Esclerose Múltipla/patologia , Retina/patologia , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Tomografia de Coerência Óptica
5.
PLoS One ; 10(11): e0142383, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26544553

RESUMO

PURPOSE: The aim of this study was to evaluate the effect of axial length (AL) on the thickness of intraretinal layers in the macula using optical coherence tomography (OCT) image analysis. METHODS: Fifty three randomly selected eyes of 53 healthy subjects were recruited for this study. The median age of the participants was 29 years (range: 6 to 67 years). AL was measured for each eye using a Lenstar LS 900 device. OCT imaging of the macula was also performed by Stratus OCT. OCTRIMA software was used to process the raw OCT scans and to determine the weighted mean thickness of 6 intraretinal layers and the total retina. Partial correlation test was performed to assess the correlation between the AL and the thickness values. RESULTS: Total retinal thickness showed moderate negative correlation with AL (r = -0.378, p = 0.0007), while no correlation was observed between the thickness of the retinal nerve fiber layer (RNFL), ganglion cell layer (GCC), retinal pigment epithelium (RPE) and AL. Moderate negative correlation was observed also between the thickness of the ganglion cell layer and inner plexiform layer complex (GCL+IPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL) and AL which were more pronounced in the peripheral ring (r = -0.402, p = 0.004; r = -0.429, p = 0.002; r = -0.360, p = 0.01; r = -0.448, p = 0.001). CONCLUSIONS: Our results have shown that the thickness of the nuclear layers and the total retina is correlated with AL. The reason underlying this could be the lateral stretching capability of these layers; however, further research is warranted to prove this theory. Our results suggest that the effect of AL on retinal layers should be taken into account in future studies.


Assuntos
Comprimento Axial do Olho , Retina/anatomia & histologia , Adolescente , Adulto , Idoso , Criança , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica
6.
BMC Ophthalmol ; 14: 148, 2014 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-25428608

RESUMO

BACKGROUND: To investigate the influence of scan distance on retinal boundary detection errors (RBDEs) and retinal thickness measurements by spectral domain optical coherence tomography (SD-OCT). METHODS: 10 eyes of healthy subjects, 10 eyes with diabetic macular edema (DME) and 10 eyes with neovascular age-related macular degeneration (AMD) were examined with RTVue SD-OCT. The MM5 protocol was used in two consecutive sessions to scan the macula. For the first session, the device was set 3.5 cm from the eye in order to obtain detectable signal with low fundus image quality (suboptimal setting) while in the second session a distance of 2.5 cm was set with a good quality fundus image. The signal strength (SSI) value was recorded. The score for retinal boundary detection errors (RBDE) was calculated for ten scans of each examination. RBDE scores were recorded for the whole scan and also for the peripheral 1.0 mm region. RBDE scores, regional retinal thickness values and SSI values between the two sessions were compared. The correlation between SSI and the number of RBDEs was also examined. RESULTS: The SSI was significantly lower with suboptimal settings compared to optimal settings (63.9±12.0 vs. 68.3±12.2, respectively, p = 0.001) and the number of RBDEs was significantly higher with suboptimal settings in the "all-eyes" group along with the group of healthy subjects and eyes with DME (9.1±6.5 vs. 6.8±6.3, p = 0.007; 4.4±2.6 vs. 2.5±1.6, p = 0.035 and 9.7±3.3 vs. 5.1±3.7, p = 0.008, respectively). For these groups, significant negative correlation was found between the SSI and the number of RBDEs. In the AMD group, the number of RBDEs was markedly higher compared to the other groups and there was no difference in RBDEs between optimal and suboptimal settings with the errors being independent of the SSI. There were significantly less peripheral RBDEs with optimal settings in the "all-eyes" group and the DME subgroup (2.7±2.6 vs. 4.2±2.8, p = 0.001 and 1.4±1.7 vs. 4.1±2.2, p = 0.007, respectively). Retinal thickness in the two settings was significantly different only in the outer-superior region in DME. CONCLUSIONS: Optimal distance settings improve SD-OCT SSI with a decrease in RBDEs while retinal thickness measurements are independent of scanning distance.


Assuntos
Retinopatia Diabética/diagnóstico , Erros de Diagnóstico , Edema Macular/diagnóstico , Retina/patologia , Tomografia de Coerência Óptica/métodos , Degeneração Macular Exsudativa/diagnóstico , Estudos Transversais , Voluntários Saudáveis , Humanos , Tamanho do Órgão , Estudos Prospectivos
7.
BMC Bioinformatics ; 15: 295, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-25178846

RESUMO

BACKGROUND: The sensitivity of Optical Coherence Tomography (OCT) images to identify retinal tissue morphology characterized by early neural loss from normal healthy eyes is tested by calculating structural information and fractal dimension. OCT data from 74 healthy eyes and 43 eyes with type 1 diabetes mellitus with mild diabetic retinopathy (MDR) on biomicroscopy was analyzed using a custom-built algorithm (OCTRIMA) to measure locally the intraretinal layer thickness. A power spectrum method was used to calculate the fractal dimension in intraretinal regions of interest identified in the images. ANOVA followed by Newman-Keuls post-hoc analyses were used to test for differences between pathological and normal groups. A modified p value of <0.001 was considered statistically significant. Receiver operating characteristic (ROC) curves were constructed to describe the ability of each parameter to discriminate between eyes of pathological patients and normal healthy eyes. RESULTS: Fractal dimension was higher for all the layers (except the GCL + IPL and INL) in MDR eyes compared to normal healthy eyes. When comparing MDR with normal healthy eyes, the highest AUROC values estimated for the fractal dimension were observed for GCL + IPL and INL. The maximum discrimination value for fractal dimension of 0.96 (standard error =0.025) for the GCL + IPL complex was obtained at a FD ≤ 1.66 (cut off point, asymptotic 95% Confidence Interval: lower-upper bound = 0.905-1.002). Moreover, the highest AUROC values estimated for the thickness measurements were observed for the OPL, GCL + IPL and OS. Particularly, when comparing MDR eyes with control healthy eyes, we found that the fractal dimension of the GCL + IPL complex was significantly better at diagnosing early DR, compared to the standard thickness measurement. CONCLUSIONS: Our results suggest that the GCL + IPL complex, OPL and OS are more susceptible to initial damage when comparing MDR with control healthy eyes. Fractal analysis provided a better sensitivity, offering a potential diagnostic predictor for detecting early neurodegeneration in the retina.


Assuntos
Fractais , Processamento de Imagem Assistida por Computador/métodos , Retina/patologia , Tomografia de Coerência Óptica/métodos , Adulto , Algoritmos , Estudos de Casos e Controles , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/patologia , Diagnóstico Precoce , Feminino , Humanos , Masculino , Curva ROC , Análise de Ondaletas
8.
BMC Bioinformatics ; 15: 106, 2014 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-24725911

RESUMO

BACKGROUND: Artificial neural networks (ANNs) have been used to classify eye diseases, such as diabetic retinopathy (DR) and glaucoma. DR is the leading cause of blindness in working-age adults in the developed world. The implementation of DR diagnostic routines could be feasibly improved by the integration of structural and optical property test measurements of the retinal structure that provide important and complementary information for reaching a diagnosis. In this study, we evaluate the capability of several structural and optical features (thickness, total reflectance and fractal dimension) of various intraretinal layers extracted from optical coherence tomography images to train a Bayesian ANN to discriminate between healthy and diabetic eyes with and with no mild retinopathy. RESULTS: When exploring the probability as to whether the subject's eye was healthy (diagnostic condition, Test 1), we found that the structural and optical property features of the outer plexiform layer (OPL) and the complex formed by the ganglion cell and inner plexiform layers (GCL + IPL) provided the highest probability (positive predictive value (PPV) of 91% and 89%, respectively) for the proportion of patients with positive test results (healthy condition) who were correctly diagnosed (Test 1). The true negative, TP and PPV values remained stable despite the different sizes of training data sets (Test 2). The sensitivity, specificity and PPV were greater or close to 0.70 for the retinal nerve fiber layer's features, photoreceptor outer segments and retinal pigment epithelium when 23 diabetic eyes with mild retinopathy were mixed with 38 diabetic eyes with no retinopathy (Test 3). CONCLUSIONS: A Bayesian ANN trained on structural and optical features from optical coherence tomography data can successfully discriminate between healthy and diabetic eyes with and with no retinopathy. The fractal dimension of the OPL and the GCL + IPL complex predicted by the Bayesian radial basis function network provides better diagnostic utility to classify diabetic eyes with mild retinopathy. Moreover, the thickness and fractal dimension parameters of the retinal nerve fiber layer, photoreceptor outer segments and retinal pigment epithelium show promise for the diagnostic classification between diabetic eyes with and with no mild retinopathy.


Assuntos
Automação , Retinopatia Diabética/diagnóstico , Tomografia de Coerência Óptica , Adulto , Teorema de Bayes , Diagnóstico Precoce , Feminino , Humanos , Masculino , Tomografia de Coerência Óptica/métodos
9.
PLoS One ; 9(2): e88363, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24516641

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the possible structural changes of the macula in patients with unilateral amblyopia using optical coherence tomography (OCT) image segmentation. PATIENTS AND METHODS: 38 consecutive patients (16 male; mean age 32.4±17.6 years; range 6-67 years) with unilateral amblyopia were involved in this study. OCT examinations were performed with a time-domain OCT device, and a custom-built OCT image analysis software (OCTRIMA) was used for OCT image segmentation. The axial length (AL) was measured by a LenStar LS 900 device. Macular layer thickness, AL and manifest spherical equivalent refraction (MRSE) of the amblyopic eye were compared to that of the fellow eye. We studied if the type of amblyopia (strabismus without anisometropia, anisometropia without strabismus, strabismus with anisometropia) had any influence on macular layer thickness values. RESULTS: There was significant difference between the amblyopic and fellow eyes in MRSE and AL in all subgroups. Comparing the amblyopic and fellow eyes, we found a statistically significant difference only in the thickness of the outer nuclear layer in the central region using linear mixed model analysis keeping AL and age under control (p = 0.032). There was no significant difference in interocular difference in the thickness of any macular layers between the subgroups with one-way between-groups ANCOVA while statistically controlling for interocular difference in AL and age. CONCLUSIONS: According to our results there are subtle changes in amblyopic eyes affecting the outer nuclear layer of the fovea suggesting the possible involvement of the photoreceptors. However, further studies are warranted to support this hypothesis.


Assuntos
Ambliopia/patologia , Processamento de Imagem Assistida por Computador , Retina/patologia , Tomografia de Coerência Óptica/métodos , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Macula Lutea/patologia , Masculino , Pessoa de Meia-Idade , Refratometria , Análise de Regressão , Software , Acuidade Visual , Adulto Jovem
11.
J Cataract Refract Surg ; 38(6): 941-6, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22624892

RESUMO

PURPOSE: To evaluate and compare thickness changes in the retinal layers in the macula with optical coherence tomography (OCT) segmentation software after femtosecond laser-assisted phacoemulsification (study group) and conventional phacoemulsification (control group). SETTING: Department of Ophthalmology, Semmelweis University, Budapest, Hungary. DESIGN: Case-control study. METHODS: Total retinal thickness of the macula was evaluated using Stratus OCT 4 to 8 weeks postoperatively. The OCT images were segmented using OCT retinal image analysis software. Regional thickness data in the central area, inner rings, and outer rings were obtained and absolute and relative thicknesses of the individual retinal layers in the 2 study groups compared. Relative thickness was calculated as the ratio of the retinal layer to the total retinal thickness. RESULTS: All surgeries were uneventful. Statistically significant differences were found in absolute outer nuclear layer thickness and relative outer nuclear layer thickness in the inner and outer macular rings between the 2 groups. After adjusting for effective phaco time in multivariate modeling, type of surgery showed a significantly lower relative outer nuclear layer ratio in the inner retinal ring (0.26 with 95% confidence interval [CI], 0.25-0.27 versus 0.28 with 95% CI, 0.27-0.29; P=.03) and in the outer retinal ring (0.27 with 95% CI, 0.25-0.28 versus 0.29 with 95% CI, 0.28-0.31; P=.02) in the study group. CONCLUSION: After cataract surgery, macular edema was detectable mainly in the outer nuclear layer in both groups but was significantly less using the femtosecond laser platform.


Assuntos
Terapia a Laser , Lasers de Excimer , Edema Macular/diagnóstico , Facoemulsificação/métodos , Complicações Pós-Operatórias/diagnóstico , Retina/patologia , Tomografia de Coerência Óptica , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Edema Macular/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
12.
PLoS One ; 7(1): e30922, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22292076

RESUMO

OBJECTIVE: To evaluate macular morphology in the eyes of patients with multiple sclerosis (MS) with or without optic neuritis (ON) in previous history. METHODS: Optical coherence tomography (OCT) examination was performed in thirty-nine patients with MS and in thirty-three healthy subjects. The raw macular OCT data were processed using OCTRIMA software. The circumpapillary retinal nerve fiber layer (RNFL) thickness and the weighted mean thickness of the total retina and 6 intraretinal layers were obtained for each eye. The eyes of MS patients were divided into a group of 39 ON-affected eyes, and into a group of 34 eyes with no history of ON for the statistical analyses. Receiver operating characteristic (ROC) curves were constructed to determine which parameter can discriminate best between the non-affected group and controls. RESULTS: The circumpapillary RNFL thickness was significantly decreased in the non-affected eyes compared to controls group only in the temporal quadrant (p = 0.001) while it was decreased in the affected eyes of the MS patients in all quadrants compared to the non-affected eyes (p<0.05 in each comparison). The thickness of the total retina, RNFL, ganglion cell layer and inner plexiform layer complex (GCL+IPL) and ganglion cell complex (GCC, comprising the RNFL and GCL+IPL) in the macula was significantly decreased in the non-affected eyes compared to controls (p<0.05 for each comparison) and in the ON-affected eyes compared to the non-affected eyes (p<0.001 for each comparison). The largest area under the ROC curve (0.892) was obtained for the weighted mean thickness of the GCC. The EDSS score showed the strongest correlation with the GCL+IPL and GCC thickness (p = 0.007, r = 0.43 for both variables). CONCLUSIONS: Thinning of the inner retinal layers is present in eyes of MS patients regardless of previous ON. Macular OCT image segmentation might provide a better insight into the pathology of neuronal loss and could therefore play an important role in the diagnosis and follow-up of patients with MS.


Assuntos
Esclerose Múltipla/diagnóstico , Degeneração Neural/diagnóstico , Degeneração Retiniana/diagnóstico , Adulto , Estudos de Casos e Controles , Estudos Transversais , Técnicas de Diagnóstico Oftalmológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/complicações , Degeneração Neural/complicações , Nervo Oftálmico/patologia , Neurite Óptica/complicações , Neurite Óptica/diagnóstico , Neurite Óptica/patologia , Retina/patologia , Degeneração Retiniana/complicações , Adulto Jovem
13.
Invest Ophthalmol Vis Sci ; 52(11): 8425-32, 2011 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-21948552

RESUMO

PURPOSE: To assess the structure and function of the macula in advanced retinitis pigmentosa (RP). METHODS: Twenty-nine eyes of 22 patients with RP were compared against 17 control eyes. Time-domain optical coherence tomography (OCT) data were processed using OCTRIMA (optical coherence tomography retinal image analysis) as a means of quantifying commercial OCT system images. The thickness of the retinal nerve fiber layer (RNFL), ganglion cell layer and inner plexiform layer complex (GCL+IPL), inner nuclear layer and outer plexiform layer complex (INL+OPL), and the outer nuclear layer (ONL) were measured. Multifocal electroretinography (mfERG) was performed; two groups were formed based on the mfERG findings. Fourteen eyes had no detectable central retinal function (NCRF) on mfERG; detectable but abnormal retinal function (DRF) was present in the mfERG of the other 15 eyes. RESULTS: The thickness of the ONL in the central macular region was significantly less in the NCRF eyes compared with that in both DRF eyes and controls. The ONL was significantly thinner in the pericentral region in both patient groups compared with that in controls, whereas the thickness of the GCL+IPL and INL+OPL was significantly decreased only in the NCRF eyes. The RNFL in the peripheral region was significantly thicker, whereas the thickness of the GCL+IPL and ONL was significantly thinner in both patient groups compared with that in controls. CONCLUSIONS: The results are consistent with degeneration of the outer retina preceding inner retinal changes in RP. OCT image segmentation enables objective evaluation of retinal structural changes in RP, with potential use in the planning of therapeutic interventions and conceivably as an outcome measure.


Assuntos
Macula Lutea/fisiopatologia , Fibras Nervosas/patologia , Células Fotorreceptoras Retinianas Cones/patologia , Células Ganglionares da Retina/patologia , Retinose Pigmentar/fisiopatologia , Adolescente , Adulto , Eletrorretinografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia , Adulto Jovem
14.
J Biomed Opt ; 16(5): 056004, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21639572

RESUMO

PURPOSE: To compare thickness measurements between Fourier-domain optical coherence tomography (FD-OCT) and time-domain OCT images analyzed with a custom-built OCT retinal image analysis software (OCTRIMA). METHODS: Macular mapping (MM) by StratusOCT and MM5 and MM6 scanning protocols by an RTVue-100 FD-OCT device are performed on 11 subjects with no retinal pathology. Retinal thickness (RT) and the thickness of the ganglion cell complex (GCC) obtained with the MM6 protocol are compared for each early treatment diabetic retinopathy study (ETDRS)-like region with corresponding results obtained with OCTRIMA. RT results are compared by analysis of variance with Dunnett post hoc test, while GCC results are compared by paired t-test. RESULTS: A high correlation is obtained for the RT between OCTRIMA and MM5 and MM6 protocols. In all regions, the StratusOCT provide the lowest RT values (mean difference 43 ± 8 µm compared to OCTRIMA, and 42 ± 14 µm compared to RTVue MM6). All RTVue GCC measurements were significantly thicker (mean difference between 6 and 12 µm) than the GCC measurements of OCTRIMA. CONCLUSION: High correspondence of RT measurements is obtained not only for RT but also for the segmentation of intraretinal layers between FD-OCT and StratusOCT-derived OCTRIMA analysis. However, a correction factor is required to compensate for OCT-specific differences to make measurements more comparable to any available OCT device.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Retina/patologia , Retinoscopia/métodos , Tomografia de Coerência Óptica/métodos , Idoso , Feminino , Análise de Fourier , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Ideggyogy Sz ; 63(9-10): 320-6, 2010 Sep 30.
Artigo em Húngaro | MEDLINE | ID: mdl-21033421

RESUMO

Neuromyelitis optica (NMO, Devic-syndrome) is a rare, relapsing autoimmune disease of the central nervous system, which is distinguished from other demyelinating disorders by a recently identified, specific autoantibody. By demonstrating the anti-aquaporin-4 IgG in the serum, a heterogenous group of syndromes can be defined, called NMO-spectrum. In the future, optical coherence tomography may support this diagnosis besides the clinical features, imaging examinations and presence of serum antibody. Early recognition and treatment can improve clinical outcome even in serious condition. Long-term immunosuppressive therapy is advised to prevent further relapses and to stabilize or improve clinical status. Hereby, we report a case of a 51-year-old woman, under treatment for one and a half years. We summarize the current knowledge about the pathomechanism, diagnostic strategy and therapy of neuromyelitis optica. We review recent findings and the diagnostic value of a new, non-invasive ophtalmological examination, the optical coherence tomography. According to the first results, this method may be helpful in the early differential diagnosis of optic neuritis.


Assuntos
Neuromielite Óptica/diagnóstico , Neuromielite Óptica/terapia , Diagnóstico Precoce , Feminino , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Neuromielite Óptica/líquido cefalorraquidiano , Tomografia de Coerência Óptica
16.
Ophthalmic Surg Lasers Imaging ; 41(6): 593-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20839667

RESUMO

BACKGROUND AND OBJECTIVE: Diabetic macular edema has several patterns on optical coherence tomography. This retrospective study aimed to assess which retinal layers show thickness changes in type 1 diffuse diabetic macular edema with preserved vision. PATIENTS AND METHODS: Eleven eyes with diffuse diabetic macular edema on optical coherence tomography and eight control eyes with 20/20 best-corrected visual acuity were enrolled. Optical coherence tomography images were segmented using an algorithm of the authors' design (OCTRIMA): regional thickness data in the central area, pericentral rings, and peripheral rings were obtained for the retinal cellular layers. RESULTS: The retinal nerve fiber layer showed no changes, the ganglion cell and inner plexiform composite layer and the ganglion cell complex were thicker only in the pericentral regions, and all other layers were thicker in all regions in diffuse diabetic macular edema. Macular thickness was normal in the peripheral region. CONCLUSION: The results show that the outer retina in the foveal area is the most affected in diffuse diabetic macular edema.


Assuntos
Retinopatia Diabética/diagnóstico , Edema Macular/diagnóstico , Fibras Nervosas/patologia , Retina/patologia , Tomografia de Coerência Óptica , Acuidade Visual , Adulto , Idoso , Diabetes Mellitus Tipo 1 , Retinopatia Diabética/fisiopatologia , Feminino , Fundo de Olho , Humanos , Edema Macular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Células Ganglionares da Retina/patologia , Estudos Retrospectivos
17.
J Biomed Opt ; 15(4): 046015, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20799817

RESUMO

We demonstrate quantitative analysis and error correction of optical coherence tomography (OCT) retinal images by using a custom-built, computer-aided grading methodology. A total of 60 Stratus OCT (Carl Zeiss Meditec, Dublin, California) B-scans collected from ten normal healthy eyes are analyzed by two independent graders. The average retinal thickness per macular region is compared with the automated Stratus OCT results. Intergrader and intragrader reproducibility is calculated by Bland-Altman plots of the mean difference between both gradings and by Pearson correlation coefficients. In addition, the correlation between Stratus OCT and our methodology-derived thickness is also presented. The mean thickness difference between Stratus OCT and our methodology is 6.53 microm and 26.71 microm when using the inner segment/outer segment (IS/OS) junction and outer segment/retinal pigment epithelium (OS/RPE) junction as the outer retinal border, respectively. Overall, the median of the thickness differences as a percentage of the mean thickness is less than 1% and 2% for the intragrader and intergrader reproducibility test, respectively. The measurement accuracy range of the OCT retinal image analysis (OCTRIMA) algorithm is between 0.27 and 1.47 microm and 0.6 and 1.76 microm for the intragrader and intergrader reproducibility tests, respectively. Pearson correlation coefficients demonstrate R(2)>0.98 for all Early Treatment Diabetic Retinopathy Study (ETDRS) regions. Our methodology facilitates a more robust and localized quantification of the retinal structure in normal healthy controls and patients with clinically significant intraretinal features.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Retina/anatomia & histologia , Retinoscopia/métodos , Tomografia de Coerência Óptica/métodos , Inteligência Artificial , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
J Biomed Opt ; 14(6): 064023, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20059261

RESUMO

We determine the reliability and reproducibility of retinal thickness measurements with a custom-built OCT retinal image analysis software (OCTRIMA). Ten eyes of five healthy subjects undergo repeated standard macular thickness map scan sessions by two experienced examiners using a Stratus OCT device. Automatic/semi automatic thickness quantification of the macula and intraretinal layers is performed using OCTRIMA software. Intraobserver, interobserver, and intervisit repeatability and reproducibility coefficients, and intraclass correlation coefficients (ICCs) per scan are calculated. Intraobserver, interobserver, and intervisit variability combined account for less than 5% of total variability for the total retinal thickness measurements and less than 7% for the intraretinal layers except the outer segment/ retinal pigment epithelium (RPE) junction. There is no significant difference between scans acquired by different observers or during different visits. The ICCs obtained for the intraobserver and intervisit variability tests are greater than 0.75 for the total retina and all intraretinal layers, except the inner nuclear layer intraobserver and interobserver test and the outer plexiform layer, intraobserver, interobserver, and intervisit test. Our results indicate that thickness measurements for the total retina and all intraretinal layers (except the outer segment/RPE junction) performed using OCTRIMA are highly repeatable and reproducible.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Retina/anatomia & histologia , Tomografia de Coerência Óptica/métodos , Adulto , Análise de Variância , Humanos , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...