Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Medicine (Baltimore) ; 100(20): e26016, 2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34011103

RESUMO

ABSTRACT: To examine potential risk factors associated with biochemical alterations in renal function in a population diagnosed with HIV/AIDS undergoing antiretroviral treatment.This is an observational, transversal, and relational design study that included 179 HIV-seropositive subjects. Glucose serum, cholesterol, triglycerides, total proteins, albumin, creatine, urea, blood urea nitrogen (BUN), and electrolytes levels were determined for each individual. Renal function was evaluated through the glomerular filtration rate (GFR), using the CKD-EPI equation. Chronic kidney disease (CKD) was defined as estimated glomerular filtration rate  < 60 mL/min/1.73 m2. Univariate model significant variables, with a 95% confidence interval (CI), were included in a multivariate logistic regression analysis.CKD prevalence in patients was 7.3%, with comorbidities of 7.8% for type 2 diabetes mellitus, 7.3% for arterial hypertension, and 35.2% for dyslipidemia. Additionally, both hypernatremia and hypophosphatemia were detected in 57% (n = 102) of the patients. Multivariate logistic regression suggested that CD4+ T cell count < 200 (P = .02; OR 0.2; CI 95% 0.08-0.8) was associated to hyponatremia; similarly, detectable viral load was associated to hypokalemia (P = .02; OR 5.1; CI 95% 1.2-21.3), hypocalcemia (P = .01; OR 4.1; CI 95% 1.3-12.3), and hypermagnesemia (OR 3.9; CI 95% 1.1-13.6). Patient age was associated to both hypophosphatemia (P = .01; OR 2.4; CI 95% 1.1-5.0) and hypermagnesemia (P = .01; OR 2.8; IC 95% 1.1-7.0), and high creatinine levels were associated to nucleoside reverse transcriptase inhibitor treatment (P = .001; OR 42.5; CI 95% 2.2-806.9). Lastly, high BUN levels were associated to age (P = .03; OR 3.8; CI 95% 1.0-14.4), while GFR 60 to 89 mL/min/1.73 m2 was associated to dyslipidemia (P = .02; OR 2.2; CI 95% 1.1-4.5).CD4+ T cell and viral load were the main factors associated with renal biochemical alterations.


Assuntos
Eletrólitos/sangue , Taxa de Filtração Glomerular/fisiologia , Soropositividade para HIV/sangue , Soropositividade para HIV/complicações , Insuficiência Renal Crônica/epidemiologia , Adulto , Idoso , Antirretrovirais/uso terapêutico , Feminino , Soropositividade para HIV/tratamento farmacológico , Humanos , Masculino , México , Pessoa de Meia-Idade , Prevalência , Insuficiência Renal Crônica/diagnóstico , Fatores de Risco , Adulto Jovem
2.
JAMA ; 295(16): 1901-6, 2006 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-16639048

RESUMO

CONTEXT: Pacemakers and implantable cardioverter-defibrillators (ICDs) are complex medical devices proven to reduce mortality in specific high-risk patient populations. It is not known if increasing device complexity is associated with decreased reliability. OBJECTIVES: To analyze postapproval annual reports submitted to the US Food and Drug Administration (FDA) by manufacturers of pacemakers and ICDs to determine the reported number and rate of pacemaker and ICD malfunctions and to assess trends in device performance. DESIGN AND SETTING: Pacemaker and ICD annual reports submitted to the FDA for the years 1990-2002 were reviewed. A pacemaker or ICD generator was defined as having malfunctioned if it was explanted due to an observed malfunction, returned to the manufacturer, and confirmed by the manufacturer to be functioning inappropriately. Leads and biventricular devices were not included in the study. Deaths were attributed to device malfunction only if they were witnessed, the malfunction immediately led to the death, and the malfunction was confirmed by the manufacturer. MAIN OUTCOME MEASURES: Number of implanted pacemaker and ICD generators; number of reported malfunctions; and annual malfunction replacement rates. Generator malfunction replacement rates were defined as the annual number of replacements due to confirmed malfunction divided by the annual number of implants. RESULTS: During the study period, 2.25 million pacemakers and 415,780 ICDs were implanted in the United States. Overall, 17,323 devices (8834 pacemakers and 8489 ICDs) were explanted due to confirmed malfunction. Battery/capacitor abnormalities (4085 malfunctions [23.6%]) and electrical issues (4708 malfunctions [27.1%]) accounted for half of the total device failures. The annual pacemaker malfunction replacement rate per 1000 implants decreased significantly during the study, from a peak of 9.0 in 1993 to a low of 1.4 in 2002 (P = .006 for trend). In contrast, the ICD malfunction replacement rate per 1000 implants, after decreasing from 38.6 in 1993 to 7.9 in 1996, increased markedly during the latter half of the study, peaking in 2001 at 36.4 (P = .04 for trend). More than half of the reported ICD malfunctions occurred in the last 3 years of the study. Overall, the annual ICD malfunction replacement rate was significantly higher than the pacemaker malfunction replacement rate (mean [SD], 20.7 [11.6] vs 4.6 [2.2] replacements per 1000 implants; P<.001; rate ratio, 5.9 [95% confidence interval, 2.7-9.1]). Sixty-one deaths (30 pacemaker patients, 31 ICD patients) were attributable to device malfunction. CONCLUSIONS: This study demonstrates that thousands of patients have been affected by pacemaker and ICD malfunctions, the pacemaker malfunction replacement rate has decreased, the ICD malfunction replacement rate increased during the latter half of the study, and the ICD malfunction replacement rate is significantly higher than that for pacemakers. Although pacemakers and ICDs are important life-sustaining devices that have saved many lives, careful monitoring of device performance is still required.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Vigilância de Produtos Comercializados , Desfibriladores Implantáveis/efeitos adversos , Falha de Equipamento , Humanos , Marca-Passo Artificial/efeitos adversos , Estados Unidos , United States Food and Drug Administration
3.
J Cardiovasc Electrophysiol ; 15(10): 1207-11, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15485449

RESUMO

INTRODUCTION: Issues in transthoracic defibrillation, including waveform shape, fixed versus escalating dose protocol, and low- versus high-energy shocks, can be addressed by examining the defibrillation dose-response curve. We tested the hypothesis that, for commonly used defibrillation waveforms, the steepness of the overall defibrillation dose-response curve, measured as normalized curve width, correlates with the probability of a successful defibrillation being immediate at the shock intensity producing 50% success. METHODS AND RESULTS: We used 16 isolated rabbit hearts to determine probability of overall success as a function of shock intensity and probability that a successful defibrillation is immediate rather than progressive (followed by several extrasystoles) at the shock intensity producing 50% overall defibrillation success. Two waveform pairs were tested--a monophasic damped sine versus a biphasic truncated exponential waveform commonly used for transthoracic defibrillation, and a monophasic/biphasic truncated exponential waveform pair similar to those used in internal cardioverter defibrillators. There was a close correlation between probability of a successful defibrillation being immediate at 150 and normalized curve width for the defibrillation dose-response curve. CONCLUSION: Our findings suggest that a high probability of successful defibrillation being immediate at low shock intensities is correlated with a narrow normalized curve width for the defibrillation dose-response curve.


Assuntos
Cardioversão Elétrica/métodos , Potenciais de Ação , Animais , Desfibriladores , Técnicas In Vitro , Probabilidade , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...