Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Nanobioscience ; 23(1): 157-166, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37549091

RESUMO

This paper reports a sensor architecture for continuous monitoring of biomarkers directly in the blood, especially for ICU/CCU patients requiring critical care and rapid biomarker measurement. The sensor is based on a simple optical fiber that can be inserted through a catheter into the bloodstream, wherein gold nanoparticles are attached at its far distal end as a plasmonic material for highly sensitive opto-chemical sensing of target biomolecules (glucose in our application) via the excitation of surface plasmon polaritons. For specificity, the nanoparticles are functionalized with a specific receptor enzyme that enables the localized surface plasmon resonance (LSPR)-based targeted bio-sensing. Further, a micro dialysis probe is introduced in the proposed architecture, which facilitates continuous monitoring for an extended period without fouling the sensor surface with cells and blood debris present in whole blood, leading to prolonged enhanced sensitivity and limit of detection, relative to existing state-of-the-art continuous monitoring devices that can conduct direct measurements in blood. To establish this proof-of-concept, we tested the sensor device to monitor glucose in-vivo involving an animal model, where continuous monitoring was done directly in the circulation of living rats. The sensor's sensitivity to glucose was found to be 0.0354 a.u./mg.dl-1 with a detection limit of 50.89 mg/dl.


Assuntos
Nanopartículas Metálicas , Fibras Ópticas , Humanos , Animais , Ratos , Glicemia , Automonitorização da Glicemia , Ouro/química , Nanopartículas Metálicas/química , Ressonância de Plasmônio de Superfície , Glucose , Unidades de Terapia Intensiva
2.
Sensors (Basel) ; 23(15)2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37571634

RESUMO

Identifying disease biomarkers and detecting hazardous, explosive, flammable, and polluting gases and chemicals with extremely sensitive and selective sensor devices remains a challenging and time-consuming research challenge. Due to their exceptional characteristics, semiconducting metal oxides (SMOxs) have received a lot of attention in terms of the development of various types of sensors in recent years. The key performance indicators of SMOx-based sensors are their sensitivity, selectivity, recovery time, and steady response over time. SMOx-based sensors are discussed in this review based on their different properties. Surface properties of the functional material, such as its (nano)structure, morphology, and crystallinity, greatly influence sensor performance. A few examples of the complicated and poorly understood processes involved in SMOx sensing systems are adsorption and chemisorption, charge transfers, and oxygen migration. The future prospects of SMOx-based gas sensors, chemical sensors, and biological sensors are also discussed.

3.
Sci Rep ; 13(1): 9848, 2023 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-37330620

RESUMO

This work reports a first-of-its-kind hybrid wearable physicochemical sensor suite that we call PlantFit for simultaneous measurement of two key phytohormones, salicylic acid, and ethylene, along with vapor pressure deficit and radial growth of stem in live plants. The sensors are developed using a low-cost and roll-to-roll screen printing technology. A single integrated flexible patch that contains temperature, humidity, salicylic acid, and ethylene sensors, is installed on the leaves of live plants. The strain sensor with in-built pressure correction capability is wrapped around the plant stem to provide pressure-compensated stem diameter measurements. The sensors provide real-time information on plant health under different amounts of water stress conditions. The sensor suite is installed on bell pepper plants for 40 days and measurements of salicylic acid, ethylene, temperature, humidity, and stem diameter are recorded daily. In addition, sensors are installed on different parts of the same plant to investigate the spatiotemporal dynamics of water transport and phytohormone responses. Subsequent correlation and principal component analyses demonstrate the strong association between hormone levels, vapor pressure deficit, and water transport in the plant. Our findings suggest that the mass deployment of PlantFit in agricultural settings will aid growers in detecting water stress/deficiency early and in implementing early intervention measures to reduce stress-induced yield decline.


Assuntos
Desidratação , Etilenos , Humanos , Temperatura , Reguladores de Crescimento de Plantas , Ácido Salicílico
4.
Micromachines (Basel) ; 14(1)2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36677256

RESUMO

Plant-microbe interactions are critical for ecosystem functioning and driving rhizosphere processes. To fully understand the communication pathways between plants and rhizosphere microbes, it is crucial to measure the numerous processes that occur in the plant and the rhizosphere. The present review first provides an overview of how plants interact with their surrounding microbial communities, and in turn, are affected by them. Next, different optical biosensing technologies that elucidate the plant-microbe interactions and provide pathogenic detection are summarized. Currently, most of the biosensors used for detecting plant parameters or microbial communities in soil are centered around genetically encoded optical and electrochemical biosensors that are often not suitable for field applications. Such sensors require substantial effort and cost to develop and have their limitations. With a particular focus on the detection of root exudates and phytohormones under biotic and abiotic stress conditions, novel low-cost and in-situ biosensors must become available to plant scientists.

5.
Sensors (Basel) ; 22(18)2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36146243

RESUMO

Performance of photonic devices critically depends upon their efficiency on controlling the flow of light therein. In the recent past, the implementation of plasmonics, two-dimensional (2D) materials and metamaterials for enhanced light-matter interaction (through concepts such as sub-wavelength light confinement and dynamic wavefront shape manipulation) led to diverse applications belonging to spectroscopy, imaging and optical sensing etc. While 2D materials such as graphene, MoS2 etc., are still being explored in optical sensing in last few years, the application of plasmonics and metamaterials is limited owing to the involvement of noble metals having a constant electron density. The capability of competently controlling the electron density of noble metals is very limited. Further, due to absorption characteristics of metals, the plasmonic and metamaterial devices suffer from large optical loss. Hence, the photonic devices (sensors, in particular) require that an efficient dynamic control of light at nanoscale through field (electric or optical) variation using substitute low-loss materials. One such option may be plasmonic metasurfaces. Metasurfaces are arrays of optical antenna-like anisotropic structures (sub-wavelength size), which are designated to control the amplitude and phase of reflected, scattered and transmitted components of incident light radiation. The present review put forth recent development on metamaterial and metastructure-based various sensors.

6.
Sensors (Basel) ; 22(14)2022 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-35890880

RESUMO

Metabolic syndrome (MS) is a cluster of conditions that increases the probability of heart disease, stroke, and diabetes, and is very common worldwide. While the exact cause of MS has yet to be understood, there is evidence indicating the relationship between MS and the dysregulation of the immune system. The resultant biomarkers that are expressed in the process are gaining relevance in the early detection of related MS. However, sensing only a single analyte has its limitations because one analyte can be involved with various conditions. Thus, for MS, which generally results from the co-existence of multiple complications, a multi-analyte sensing platform is necessary for precise diagnosis. In this review, we summarize various types of biomarkers related to MS and the non-invasively accessible biofluids that are available for sensing. Then two types of widely used sensing platform, the electrochemical and optical, are discussed in terms of multimodal biosensing, figure-of-merit (FOM), sensitivity, and specificity for early diagnosis of MS. This provides a thorough insight into the current status of the available platforms and how the electrochemical and optical modalities can complement each other for a more reliable sensing platform for MS.


Assuntos
Técnicas Biossensoriais , Doenças Metabólicas , Biomarcadores , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Humanos , Doenças Metabólicas/diagnóstico
7.
Opt Express ; 26(5): 6331-6344, 2018 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-29529825

RESUMO

We present an effective yet simple approach to study the dynamic variations in optical properties (such as the refractive index (RI)) of graphene oxide (GO) when exposed to gases in the visible spectral region, using the thin-film interference method. The dynamic variations in the complex refractive index of GO in response to exposure to a gas is an important factor affecting the performance of GO-based gas sensors. In contrast to the conventional ellipsometry, this method alleviates the need of selecting a dispersion model from among a list of model choices, which is limiting if an applicable model is not known a priori. In addition, the method used is computationally simpler, and does not need to employ any functional approximations. Further advantage over ellipsometry is that no bulky optics is required, and as a result it can be easily integrated into the sensing system, thereby allowing the reliable, simple, and dynamic evaluation of the optical performance of any GO-based gas sensor. In addition, the derived values of the dynamically changing RI values of the GO layer obtained from the method we have employed are corroborated by comparing with the values obtained from ellipsometry.

8.
Lab Chip ; 18(5): 803-817, 2018 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-29431801

RESUMO

This paper reports an integrated dual-modality microfluidic sensor chip, consisting of a patterned periodic array of nanoposts coated with gold (Au) and graphene oxide (GO), to detect target biomarker molecules in a limited sample volume. The device generates both electrochemical and surface plasmon resonance (SPR) signals from a single sensing area of Au-GO nanoposts. The Au-GO nanoposts are functionalized with specific receptor molecules, serving as a spatially well-defined nanostructured working electrode for electrochemical sensing, as well as a nanostructured plasmonic crystal for SPR-based sensing via the excitation of surface plasmon polaritons. High sensitivity of the electrochemical measurement originates from the presence of the nanoposts on the surface of the working electrode where radial diffusion of redox species occurs. Complementarily, the SPR detection allows convenient tracking of dynamic antigen-antibody interactions, to describe the association and dissociation phases occurring at the sensor surface. The soft-lithographically formed nanoposts provide high reproducibility of the sensor response to epidermal growth factor receptor (ErbB2) molecules even at a femtomolar level. Sensitivities of the electrochemical measurements to ErbB2 are found to be 20.47 µA µM-1 cm-2 in a range from 1 fM to 0.1 µM, and those of the SPR measurements to be 1.35 nm µM-1 in a range from 10 pM to 1 nM, and 0.80 nm µM-1 in a range from 1 nM to 0.1 µM. The integrated dual-modality sensor offers higher sensitivity (through higher surface area and diffusions from nanoposts for electrochemical measurements), as well as the dynamic measurements of antigen-antibody bindings (through the SPR measurement), while operating simultaneously in a same sensing area using the same sample volume.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Receptor ErbB-2/análise , Ressonância de Plasmônio de Superfície , Biomarcadores/análise , Técnicas Eletroquímicas , Eletrodos , Ouro/química , Grafite/química , Humanos , Nanoestruturas/química , Óxidos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...