Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ESC Heart Fail ; 9(3): 1584-1596, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35365936

RESUMO

AIMS: The HINODE study aimed to analyse rates of mortality, appropriately treated ventricular arrhythmias (VA), and heart failure in Japanese patients and compared with those in Western patients. METHODS AND RESULTS: After treatment decisions following contemporary practice in Japan, patients were prospectively enrolled into four cohorts: (i) internal cardioverter-defibrillator (ICD), (ii) cardiac resynchronization therapy (CRT) defibrillator (CRT-D), (iii) standard medical therapy ('non-device': ND), or (iv) pacing (indicated for CRT; received pacemaker or CRT pacing). Cohorts 1-3 required a left ventricular ejection fraction ≤35%, a history of heart failure, and a need for primary prevention of sudden cardiac death based on two to five previously identified risk factors. Endpoint outcomes were adjudicated by the independent committees. ICD and CRT-D cohorts, considered as high-voltage (HV) cohorts, were pooled for Kaplan-Meier analysis and propensity-matched to Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) arm B and C patients. The study enrolled 354 patients followed for 19.6 ± 6.5 months, with a minimum of 12 months. Propensity-matched HV cohorts showed comparable VA (P = 0.61) and mortality rates (P = 0.29) for HINODE and MADIT-RIT. The ND cohort presented a high crossover rate to ICD therapy (6.1%, n = 7/115), and the CRT-D cohort showed elevated mortality rates. The pacing cohort revealed that patients implanted with pacemakers had higher mortality (26.0%) than those with CRT-Pacing (8.4%, P = 0.05). CONCLUSIONS: The mortality and VA event rates of landmark trials are applicable to patients with primary prevention in Japan. Patients who did not receive guideline-indicated CRT devices had poor outcomes.


Assuntos
Insuficiência Cardíaca , Função Ventricular Esquerda , Arritmias Cardíacas , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Humanos , Japão/epidemiologia , Volume Sistólico , Resultado do Tratamento
2.
Circulation ; 128(7): 687-93, 2013 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-23868858

RESUMO

BACKGROUND: Atrial-based pacing is associated with lower risk of atrial fibrillation (AF) in sick sinus syndrome compared with ventricular pacing; nevertheless, the impact of site and rate of atrial pacing on progression of AF remains unclear. We evaluated whether long-term atrial pacing at the right atrial (RA) appendage versus the low RA septum with (ON) or without (OFF) a continuous atrial overdrive pacing algorithm can prevent the development of persistent AF. METHODS AND RESULTS: We randomized 385 patients with paroxysmal AF and sick sinus syndrome in whom a pacemaker was indicated to pacing at RA appendage ON (n=98), RA appendage OFF (n=99), RA septum ON (n=92), or RA septum OFF (n=96). The primary outcome was the occurrence of persistent AF (AF documented at least 7 days apart or need for cardioversion). Demographic data were homogeneous across both pacing site (RA appendage/RA septum) and atrial overdrive pacing (ON/OFF). After a mean follow-up of 3.1 years, persistent AF occurred in 99 patients (25.8%; annual rate of persistent AF, 8.3%). Alternative site pacing at the RA septum versus conventional RA appendage (hazard ratio=1.18; 95% confidence interval, 0.79-1.75; P=0.65) or continuous atrial overdrive pacing ON versus OFF (hazard ratio=1.17; 95% confidence interval, 0.79-1.74; P=0.69) did not prevent the development of persistent AF. CONCLUSIONS: In patients with paroxysmal AF and sick sinus syndrome requiring pacemaker implantation, an alternative atrial pacing site at the RA septum or continuous atrial overdrive pacing did not prevent the development of persistent AF. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. UNIQUE IDENTIFIER: NCT00419640.


Assuntos
Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial/métodos , Síndrome do Nó Sinusal/complicações , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Apêndice Atrial , Fibrilação Atrial/etiologia , Fibrilação Atrial/terapia , Doenças Cardiovasculares/mortalidade , Progressão da Doença , Cardioversão Elétrica , Feminino , Septos Cardíacos , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Estudos Prospectivos , Síndrome do Nó Sinusal/terapia , Acidente Vascular Cerebral/etiologia , Falha de Tratamento
SELEÇÃO DE REFERÊNCIAS