Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(5)2024 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-38475032

RESUMO

We are currently investigating the ultrasound imaging of a sensor that consists of a randomized encoding mask attached to a single lead zirconate titanate (PZT) oscillator for a puncture microscope application. The proposed model was conducted using a finite element method (FEM) simulator. To increase the number of measurements required by a single element system that affects its resolution, the transducer was rotated at different angles. The image was constructed by solving a linear equation of the image model resulting in a poor quality. In a previous work, the phase information was extracted from the echo signal to improve the image quality. This study proposes a strategy by integrating the weighted frequency subbands compound and a super-resolution technique to enhance the resolution in range and lateral direction. The image performance with different methods was also evaluated using the experimental data. The results indicate that better image resolution and speckle suppression were obtained by applying the proposed method.

2.
Sensors (Basel) ; 19(10)2019 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-31137819

RESUMO

We are studying a method based on the carrier frequency sweep for axial high resolution ultrasonic imaging to provide the range resolution that corresponds to the carrier wavelength. The first proposal for this type of method was based on the focused pulse transmission. Then, to improve the frame rate, the method was extended to a synthetic aperture-type method that transmits divergent pulses. While the method is effective in terms of the frame rate, degradation of the enhanced axial resolution performance is a concern. Therefore, using finite element method simulations and simple experiments, the performance of the synthetic aperture method with high axial resolution is evaluated via comparison with the original method using focused pulses. The evaluation confirmed that the performance degradation of the synthetic aperture method is caused by weakness in the transmitted wave intensity and deterioration of the phase coherence in the reception beamforming. Based on this result, we propose a method that is less affected by the latter cause and show its effectiveness.

3.
Langmuir ; 28(8): 3814-20, 2012 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-22292931

RESUMO

The adhesion and friction properties of molecularly thin perfluoropolyether (PFPE) lubricant films dip-coated on a diamond-like carbon (DLC) overcoat of magnetic disks were studied using a pin-on-disk-type micro-tribotester that we developed. The load and friction forces were simultaneously measured on a rotating disk surface under an increasing/decreasing load cycle and slow sliding conditions. Experiments were performed using two types of PFPE lubricants: Fomblin Z-tetraol2000S with functional end-groups and Fomblin Z-03 without any end-group. The curves of the friction force as a function of the applied load agree with the curves estimated using the Johnson-Kendall-Roberts (JKR) model. The friction forces on the Z-03 films having different thicknesses were not found to decrease drastically; however, the friction forces on the Z-tetraol film were found to decrease drastically when the film thickness is more than ~1.2 nm. This drastic change in the case of the Z-tetraol film is estimated to be affected by the coverage of the lubricant film.

4.
J Med Ultrason (2001) ; 38(3): 119-27, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27278499

RESUMO

PURPOSE: This paper describes an investigation into direct observation of microscopic images of tissue using a thin acoustic wave guide. METHODS: First, the characteristics of the ultrasonic wave propagated in a fused quartz fiber were measured using the reflection method in order to study the insertion loss and the frequency shift of the ultrasonic wave transmitted from the transducer. Next, a receiving transducer was placed close to the end of the fiber, and the characteristics of the ultrasonic waves propagated through the acoustic coupling medium were measured using the penetration method in order to study the insertion loss and the frequency-dependent attenuation of the penetrated waves. Finally, a C-mode image was obtained by optimizing the measuring conditions using the results of the above measurements and scanning the ultrasonic beams on a target (coin) in water. RESULTS: A reflected wave with a peak frequency of approximately 220 MHz was obtained from the end of the fiber. The transmitted ultrasonic waves propagated through the acoustic coupling medium were detected with a frequency range of approximately 125-170 MHz, and the maximum detectable distance of the waves was approximately 1.2 mm within the 100-MHz frequency range. Finally, a high-frequency C-mode image of a coin in water was obtained using a tapered fused quartz fiber. CONCLUSION: The results suggest that it is necessary to improve the signal-to-noise ratio and reduce the insertion loss in the experimental system in order to make it possible to obtain microscopic images of tissue.

5.
Neural Comput ; 14(6): 1261-6, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12020445

RESUMO

The expectation-maximization (EM) algorithm with split-and-merge operations (SMEM algorithm) proposed by Ueda, Nakano, Ghahramani, and Hinton (2000) is a nonlocal searching method, applicable to mixture models, for relaxing the local optimum property of the EM algorithm. In this article, we point out that the SMEM algorithm uses the acceptance-rejection evaluation method, which may pick up a distribution with smaller likelihood, and demonstrate that an increase in likelihood can then be guaranteed only by comparing log likelihoods.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...