Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 191: 113463, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34198171

RESUMO

An osmium-coated lensed fiber (OLF) probe combined with a silver-coated black silicon (SBS) substrate was used to generate a dielectrophoretic (DEP) force that traps bacteria and enables Raman signal detection from bacteria. The lensed fiber coated with a 2-nm osmium layer was used as an electrode for the DEP force and also as a lens to excite Raman signals. The black silicon coated with a 150-nm silver layer was used both as the surface-enhanced Raman scattering (SERS) substrate and the counter electrode. The enhanced Raman signal was collected by the same OLF probe and further analyzed with a spectrometer. For Raman measurements, a drop of bacterial suspension was placed between the OLF probe and the SBS substrate. By controlling the frequency of an AC voltage on the OLF probe and SBS substrate, a DEP force at 1 MHz concentrated bacteria on the SBS surface and removed the unbound micro-objects in the solution at 1 kHz. A bacteria concentration of 6 × 104 CFU/mL (colony forming units per mL) could be identified in less than 15 min, using a volume of only 1 µL, by recording the variation of the Raman peak at 740 cm-1.


Assuntos
Técnicas Biossensoriais , Silício , Bactérias , Análise Espectral Raman
2.
Biosens Bioelectron ; 170: 112677, 2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-33032197

RESUMO

In recent years, imidacloprid and fipronil have been reported to harm beneficial insects, such as honey bees, and to potentially pose risks to mammals, including humans. Considering their widespread use and potential minimum toxic range from 10 ppb to 1 ppm (species dependent), a simple, rapid, sensitive, and reliable method for screening and detection is urgently needed. Here, we present a surface plasmon resonance (SPR)-based nanoplasmonic chip integrated with a multichannel spectral imaging system to detect ecosystem-harming pesticides. The pre-modification of the designed mercapto-haptens reduced detection time to 2.5 h. Moreover, owing to the multichannel configuration, it was possible to introduce an internal standard analytical method to effectively reduce matrix interference in real samples; thus, the concentration of the target pesticide could be determined more precisely. The strong linearity of the spiked sample test results indicated high accuracy in quantifying target pesticides. Considering the limit of detection (~10 ppb), the cutoffs for detection and quantification were set at 15 and 45 ppb, respectively, and were used as the detection criteria. The detection results of the blind tests of real samples were also compared with those of liquid chromatography electrospray ionization tandem mass spectrometry (standard method) and were highly consistent. The custom-made integrated SPR system allows much simpler, label-free, high-throughput, and reliable on-site identification and quantification of imidacloprid and fipronil. All test results validated the platform's capability in the on-site rapid screening and detection of pesticide residues at the parts per billion and parts per million levels.


Assuntos
Técnicas Biossensoriais , Resíduos de Praguicidas , Animais , Abelhas , Ecossistema , Neonicotinoides , Nitrocompostos , Resíduos de Praguicidas/análise , Pirazóis
3.
Sensors (Basel) ; 19(22)2019 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-31717912

RESUMO

An axicon fiber tip combined with a camera device is developed to sensitively detect refractive indexes in solutions. The transparent axicon tips were made by etching optical fibers through a wet end-etching method at room temperature. When the axicon fiber tip was immersed in various refractive index media, the angular spectrum of the emitted light from the axicon fiber tip was changed. Using a low numerical aperture lens to collect the directly transmitted light, a high intensity sensitivity was achieved when the tip cone angle was about 35 to 40 degrees. We combined the axicon fiber tip with a laser diode and a smartphone into a portable refractometer. The front camera of the smartphone was used to collect the light emitted from the axicon fiber tip. By analyzing the selected area of the captured images, the refractive index can be distinguished for various solutions. The refractive index sensitivity was up to 56,000%/RIU, and the detection limit was 1.79 × 10-5 RIU. By measuring the refractive index change via the axicon fiber tip, the concentration of different mediums can be sensitively detected. The detection limits of the measurement for sucrose solutions, saline solutions, and diluted wine were 8.86 × 10-3 °Bx, 0.12‱, and 0.35%, respectively.

4.
Sensors (Basel) ; 18(7)2018 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-29986468

RESUMO

A spectral integration combined with a threshold method for the analysis of spectral scanning surface plasmon resonance (SPR) images can significantly increase signal recognition at low concentration of antibody solution. The 12-well SPR sensing plates consisted of gold-capped nanowire arrays with 500-nm period, 80-nm linewidth and 50-nm gold thickness which were used for generating multiple SPR images. A threshold method is introduced to eliminate background noises in spectral scanning images. Combining spectral integration and the threshold method, the detection limit of antibody concentration was 1.23 ng/mL. Using multiple-well SPR sensing plates and the proposed analytical method, multiple kinetic responses with spectral and spatial information on different sensing areas can be sensitively measured.

5.
ACS Sens ; 3(6): 1196-1202, 2018 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-29771118

RESUMO

A sensitive tapered optical fiber tip combined with dielectrophoretic (DEP) trapping was used for rapid and label-free detection of bacteria in water. The angular spectrum of the optical field at the fiber tip was changed with the surrounding refractive index (RI). By measuring far-field intensity change at the defocus plane, the intensity sensitivity was up to 95 200%/RIU (RI unit), and the detection limit was 5.2 × 10-6 RIU at 0.5% intensity stability. By applying an AC voltage to a Ti/Al coated fiber tip and an indium-tin-oxide glass, the DEP force effectively trapped the Escherichia coli ( E. coli) near the fiber tip. Those bacteria can be directly measured from optical intensity change due to the increase of surrounding RI. By immobilizing the antibody on the Ti/Al fiber tip, the tests for specific K12 bacteria and nonspecific BL21 bacteria verified the specificity. The antibody-immobilized Ti/Al coated fiber tip with DEP trapping can detect bacteria at a concentration about 100 CFU/mL.


Assuntos
Alumínio/química , Técnicas Biossensoriais , Eletroforese , Escherichia coli/isolamento & purificação , Fibras Ópticas , Titânio/química
6.
Sensors (Basel) ; 16(3): 303, 2016 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-26927128

RESUMO

This work presents using a tapered fiber tip coated with thin metallic film to detect small particles in water with high sensitivity. When an AC voltage applied to the Ti/Al coated fiber tip and indium tin oxide (ITO) substrate, a gradient electric field at the fiber tip induced attractive/repulsive force to suspended small particles due to the frequency-dependent dielectrophoresis (DEP) effect. Such DEP force greatly enhanced the concentration of the small particles near the tip. The increase of the local concentration also increased the scattering of surface plasmon wave near the fiber tip. Combined both DEP effect and scattering optical near-field, we show the detection limit of the concentration for 1.36 µm polystyrene beads can be down to 1 particle/mL. The detection limit of the Escherichia coli (E. coli) bacteria was 20 CFU/mL. The fiber tip sensor takes advantages of ultrasmall volume, label-free and simple detection system.

7.
Nano Lett ; 15(4): 2746-50, 2015 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-25798810

RESUMO

Nanocavities inscribed in a gold thin film are optimized and designed to form a metasurface. We demonstrate both numerically and experimentally the creation of surface plasmon (SP) vortex carrying orbital angular momentum in the metasurface under linearly polarized optical excitation that carries no optical angular momentum. Moreover, depending on the orientation of the exciting linearly polarized light, we show that the metasurface is capable of providing dynamic switching between SP vortex formation or SP subwavelength focusing. The resulting SP intensities are experimentally measured using a near-field scanning optical microscope and are found in excellent quantitative agreements as compared to the numerical results.

8.
Opt Lett ; 35(7): 944-6, 2010 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-20364178

RESUMO

An optical fiber sensor based on the change of optical confinement in a subwavelength tip is presented. The optical spot is substantially increased when the environmental refractive index (RI) increases from 1.3 to 1.4. By measuring the intensity of low angular spectral components, an intensity sensitivity up to 8000% per RI unit is achieved. The fiber tip sensors take advantage of the small detection volume and real-time responses. We demonstrate the application of the nanofiber sensors for measuring concentrations of acids and evaporation rates of aqueous mixtures.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Refratometria/instrumentação , Soluções/química , Transdutores , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...