Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Aesthetic Plast Surg ; 41(4): 887-892, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28389724

RESUMO

Postural bowleg is a subclinical entity with both aesthetic and functional outcomes and appears to be common in East Asian countries. Internal rotation of the hip joint is associated with varus alignment at the knee joint of the bowleg. Strengthening exercise for the hip external rotator muscles seems to be effective in improving varus alignment of bowleg, but no standardized exercise program exists. A standardized active resistance strengthening exercise for hip external rotator muscles could improve varus alignment of the lower limb in bowlegged Korean women. In this article, a case series study was conducted to observe changes following a standardized 3-month program using equipment designed for strengthening of the hip external rotator muscles. Photogrammetric and radiographic data were used to compare the gap between knees and tibiofemoral (TF) angles before and after the exercise program. As a result, on average, the knee gap decreased by 1.6 cm. The TF angle decreased by 1.5°. Regression analysis revealed a statistically significant association between changes in knee gap and TF angle. The standardized 3-month active resistance strengthening exercise program of hip external rotator muscles was effective in improving postural deviation and cosmetic outcomes in bowlegged Korean women. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Terapia por Exercício/organização & administração , Genu Varum/reabilitação , Força Muscular/fisiologia , Treinamento Resistido/métodos , Adulto , Estudos de Coortes , Terapia por Exercício/métodos , Feminino , Seguimentos , Genu Varum/diagnóstico por imagem , Articulação do Quadril , Humanos , Postura/fisiologia , Músculos Psoas/fisiologia , Radiografia , República da Coreia , Índice de Gravidade de Doença , Resultado do Tratamento , Adulto Jovem
2.
Plast Reconstr Surg ; 134(5): 707e-716e, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25347645

RESUMO

BACKGROUND: In Asia, one of the most important factors in being physically attractive is to have aesthetically pleasing legs, which has made calf contouring surgery an issue nowadays. When one leg is abnormally changed because of various factors (e.g., iatrogenic causes, poliomyelitis, cerebral palsy, trauma, and tumor resection), the tissue atrophies. Such asymmetric calves can be corrected by various surgical methods. METHODS: Calf asymmetry is defined as a difference in the maximal circumference greater than 2.0 cm between both calves. From 2005 to 2012, the authors carried out calf contouring operations on 68 patients. For patients with mild or moderate asymmetry, selective neurectomy with or without liposuction was performed on the hypertrophic calf according to shape and severity. For patients with severe asymmetry, selective neurectomy with liposuction was performed for the hypertrophic calf, whereas the hypotrophic calf was treated with fat injection or silicone implantation. RESULTS: At a minimum of 3 months' follow-up, the mild group patients had a size difference less than 0.5 cm. The moderate and severe asymmetry groups showed size differences less than 1.2 and 2.3 cm, respectively. No functional problems or major complications were shown. Minor complications included five cases of wound dehiscence, three cases of hematoma, and six cases of hypertrophic scar at the incision site. CONCLUSION: Classifying patients into three groups according to the maximal circumferential difference between both legs and treating them separately using different surgical methods could significantly provide satisfying outcomes in both functional and aesthetic aspects. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.


Assuntos
Povo Asiático , Extremidade Inferior/cirurgia , Músculo Esquelético/cirurgia , Cirurgia Plástica/métodos , Adulto , Estudos de Coortes , Estética , Feminino , Humanos , Hipertrofia/classificação , Hipertrofia/cirurgia , Lipectomia/métodos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/patologia , Atrofia Muscular/classificação , Atrofia Muscular/cirurgia , Próteses e Implantes , República da Coreia , Medição de Risco , Resultado do Tratamento , Adulto Jovem
3.
J Craniofac Surg ; 25(4): e352-6, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25006944

RESUMO

After restoration of orbit wall fracture, preventing sequelae is important. An absorbable mesh is commonly used in orbit wall fracture, yet it has limitation due to orbit sagging when bony defect is larger than the moderate size (1 × 1 cm2). In this study, the authors present a satisfactory result in treating orbit wall fracture larger than the moderate size with a combination of absorbable mesh and demineralized bone matrix.From 2009 to 2012, 63 patients with bony defect larger than the moderate size, who were treated with a combination of absorbable mesh and demineralized bone matrix, were reviewed retrospectively. The site of bony defect, size, and applied amount of demineralized bone matrix were reviewed, and a 2-year follow-up was done. Facial computed tomography scans were checked preoperative, immediate postoperative, and 2-year postoperative.Among the 63 patients, there were 52 men and 11 women. Mean age was 33.3 years. The most common cause was blunt blow (35 cases); mean defect size was 13.36 × 12.82 mm2 in inferior wall fracture and 20.69 × 14.41 mm2 in medial wall fracture. There was no complication except for 3 cases of infraorbital nerve hypoesthesia. A 2-year follow-up computed tomography showed that the surgical site preserved bony formation without herniation. In treating moderate-sized bony defect in orbit wall fracture, absorbable mesh and demineralized bone matrix can maintain structural stability through good bony formation even after degradation of absorbable mesh.


Assuntos
Implantes Absorvíveis , Técnica de Desmineralização Óssea , Matriz Óssea , Hérnia/prevenção & controle , Doenças Orbitárias/prevenção & controle , Fraturas Orbitárias/cirurgia , Telas Cirúrgicas , Adulto , Feminino , Humanos , Masculino , Órbita/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
4.
Arch Plast Surg ; 40(5): 610-5, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24086818

RESUMO

BACKGROUND: Cephalometric analysis is essential for planning treatment in maxillofacial and aesthetic facial surgery. Although photometric analysis of the Korean nose has been attempted in the past, anthropometry of the deeper nasal structures in the same population based on computerized tomography (CT) has not been published. We therefore measured three anthropometric parameters of the nose on CT scans in our clinical series of patients. METHODS: We conducted the current retrospective study of a total of 100 patients (n=100) who underwent a CT-guided radiological measurement at our institution during a period ranging from January of 2008 to August of 2010. In these patients, we took three anthropometric measurements: the nasofrontal angle, the pyramidal angle, and the linear distance between the nasion and the tip of the nasal bone. RESULTS: The mean nasofrontal angle was 131.14° in the male patients and 140.70° in the female patients. The mean linear distance between the nasion and the tip of the nasal bone was 21.28 mm and 18.02 mm, respectively. The mean nasal pyramidal angle was 112.89° and 103.25° at the level of the nasal root, 117.49° and 115.60° at the middle level of the nasal bone, and 127.99° and 125.04° at the level of the tip of the nasal bone, respectively. CONCLUSIONS: In conclusion, our data will be helpful in the preparation of silicone implants for augmentation and/or corrective rhinoplasty in ethnic Korean people.

5.
Arch Plast Surg ; 39(1): 51-4, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22783492

RESUMO

With the gradual increase of cases using fillers, cases of patients treated by non-medical professionals or inexperienced physicians resulting in complications are also increasing. We herein report 2 patients who experienced acute complications after receiving filler injections and were successfully treated with adipose-derived stem cell (ADSCs) therapy. Case 1 was a 23-year-old female patient who received a filler (Restylane) injection in her forehead, glabella, and nose by a non-medical professional. The day after her injection, inflammation was observed with a 3×3 cm skin necrosis. Case 2 was a 30-year-old woman who received a filler injection of hyaluronic acid gel (Juvederm) on her nasal dorsum and tip at a private clinic. She developed erythema and swelling in the filler-injected area A solution containing ADSCs harvested from each patient's abdominal subcutaneous tissue was injected into the lesion at the subcutaneous and dermis levels. The wounds healed without additional treatment. With continuous follow-up, both patients experienced only fine linear scars 6 months postoperatively. By using adipose-derived stem cells, we successfully treated the acute complications of skin necrosis after the filler injection, resulting in much less scarring, and more satisfactory results were achieved not only in wound healing, but also in esthetics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...