Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 23(4): 4641-9, 2015 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-25836501

RESUMO

We demonstrated an achromatic wave plate based on parallel metal plate waveguides in the high THz frequency region. The metal plates have periodic rough structures on the surface, which allow slow transverse magnetic wave propagation and fast transverse electric wave propagation. A numerical simulation showed that the height of the periodic roughness is important for optimizing the birefringence. We fabricated stacked metal plates containing two types of structures by chemical etching. An array of small pillars on the metal plates allows higher frequency optimization. We experimentally demonstrated an achromatic quarter-wave plate in the frequency region from 2.0 to 3.1 THz.

2.
J Pharm Sci ; 103(1): 256-61, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24282048

RESUMO

Nondestructive analysis of tablet is of great importance from the aspect of productivity and safety. In terahertz (THz) region, however, the analysis of core of coated tablet has not been progressed. In this study, we have measured a flat-surface push-pull osmotic pump tablet, having no orifice, having bilayer core and a coating film layer. The bilayer core was made from the drug layer and the push layer, and acetaminophen was contained in the drug layer as a model drug. To study its structure and components, we have obtained reflection spectra from the drug layer side and the push layer side measurements using THz time-domain reflection spectroscopy (THz-TDRS). From these results, detection of the peak of acetaminophen in the spectrum from the drug layer side measurements was confirmed. We have made ridges approximated toward the peak using a general method of linear regression analysis in both spectra. Two-sample t-test was applied to their gradients, and significant difference between the drug layer and the push layer was shown. These results suggested that THz-TDRS is applicable to the analysis of structure and component of a coated tablet.


Assuntos
Comprimidos/química , Acetaminofen/química , Osmose , Solubilidade , Espectroscopia Terahertz/métodos
3.
Opt Lett ; 39(1): 146-9, 2014 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-24365844

RESUMO

We propose a simple achromatic terahertz wave plate composed of stacked parallel metal plates with a hole array. It consists of an ensemble of designed parallel plate waveguides; the high and low propagation speeds of waves in TE and TM waveguide modes with the same group velocity cause a constant phase difference over a wide frequency region. Using that wave plate, we obtained intense single- and multi-cycle THz pulses with circular polarization.

4.
Appl Opt ; 52(34): 8305-9, 2013 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-24513831

RESUMO

We demonstrated broadband terahertz (THz) wave generation by satisfying the noncollinear phase-matching condition with a reflected signal beam. We constructed a dual-wavelength optical parametric oscillator with two potassium titanium oxide phosphate crystals pumped by a frequency-doubled Nd:YAG laser. The collinear pump and signal waves were irradiated into a lithium niobate crystal. The pump and the signal waves were reflected at the crystal surface. Because the pump and the signal waves have a finite beam diameter, when the reflected signal wave and unreflected pump wave were irradiated at the correct angle, the noncollinear phase-matching condition was satisfied. By changing the incident angle to the crystal, broadband THz-wave generation with a range of over 0.2-7.2 THz was achieved.

5.
Opt Express ; 17(9): 7549-55, 2009 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-19399131

RESUMO

High-resolution tomographic imaging is demonstrated using a reflection-type terahertz time-domain spectroscopy. To realize a practical system for general use, a robust all-fiber laser was used as the pump light source. Broadband terahertz waves were generated with the combination of optical pulses compressed to 17 fs using optical fibers and a DAST crystal. Using deconvolution signal processing, the wideband spectrum of the generated terahertz waves provided high-axial resolution leading to successful imaging of a multilayered structure containing a 2-microm-thin GaAs layer. To our knowledge, this is the first demonstration of terahertz tomographic imaging of such a thin layer.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Lasers , Análise Espectral/instrumentação , Tomografia Óptica/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Radiação Terahertz
6.
Opt Express ; 16(17): 12859-65, 2008 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-18711524

RESUMO

We describe the generation and detection of broadband terahertz radiation using an all-fiber laser. Optical pulses from a mode-locked fiber laser oscillator are compressed using nonlinear and dispersion effects induced in optical fibers, and 17-fs optical pulses with 170-kW peak power are generated at the wavelength region around 1.5 microm. By injecting these pulses into an organic crystal DAST (4-N, N-dimethylamino-4'-N"-methyl-stilbazolium tosylate), broadband terahertz field is radiated at 0.1-25 THz. The frequency region exceeding 20 THz is achieved with a fiber laser for the first time.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Lasers , Fotometria/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Raios Infravermelhos , Micro-Ondas , Fibras Ópticas
7.
Opt Express ; 12(2): 317-24, 2004 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-19471540

RESUMO

We present wideband of 1180-2100 nm, flatly broadened supercontinuum (SC) generation using highly nonlinear hybrid fibers and femtosecond fiber laser. Stable and smooth spectra without fine structure are demonstrated. The hybrid fibers are constructed by fusion splicing fibers with different properties. The SC spectra can be properly controlled by the optimal design of the hybrid fiber based on the numerical analysis. The generated SC pulse shows the low relative intensity noise (RIN).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...