Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Infect Dis ; 229(4): 1147-1157, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38035792

RESUMO

BACKGROUND: Immune dysregulation in people with human immunodeficiency virus-1 (PWH) persists despite potent antiretroviral therapy and, consequently, PWH tend to have lower immune responses to licensed vaccines. However, limited information is available about the impact of mRNA vaccines in PWH. This study details the immunologic responses to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) mRNA vaccines in PWH and their impact on HIV-1. METHODS: We quantified anti-S immunoglobulin G (IgG) binding and neutralization of 3 SARS-CoV-2 variants of concern and complement activation in blood from virally suppressed men with HIV-1 (MWH) and men without HIV-1 (MWOH), and the characteristics that may impact the vaccine immune responses. We also studied antibody levels against HIV-1 proteins and HIV-1 plasma RNA. RESULTS: MWH had lower anti-S IgG binding and neutralizing antibodies against the 3 variants compared to MWOH. MWH also produced anti-S1 antibodies with a 10-fold greater ability to activate complement and exhibited higher C3a blood levels than MWOH. MWH had decreased residual HIV-1 plasma viremia and anti-Nef IgG approximately 100 days after immunization. CONCLUSIONS: MWH respond to SARS-CoV-2 mRNA vaccines with lower antibody titers and with greater activation of complement, while exhibiting a decrease in HIV-1 viremia and anti-Nef antibodies. These results suggest an important role of complement activation mediating protection in MWH.


Assuntos
COVID-19 , Soropositividade para HIV , HIV-1 , Masculino , Humanos , Vacinas contra COVID-19 , Viremia , SARS-CoV-2 , Vacinas de mRNA , COVID-19/prevenção & controle , Ativação do Complemento , Anticorpos Neutralizantes , Imunoglobulina G , Anticorpos Antivirais
2.
J Proteome Res ; 22(11): 3499-3507, 2023 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-37843028

RESUMO

Lung cancer (LC) is a leading cause of mortality, claiming more than 1.8 million deaths per year worldwide. Surgery is one of the most effective treatments when the disease is in its early stages. The study of metabolic alterations after surgical intervention with curative intent could be used to assess the response to treatment or the detection of cancer recurrence. In this study, we have evaluated the metabolomic profile of serum samples (n = 110) from preoperative (PRE) and postoperative (POST) LC patients collected at two different time points (1 month, A; 3-6 months, B) with respect to healthy people. An untargeted metabolomic platform based on reversed phase (RP) and hydrophilic interaction chromatography (HILIC), using ultra-high performance liquid chromatography (UHPLC) and mass spectrometry (MS), was applied (MassIVE ID MSV000092213). Twenty-two altered metabolites were annotated by comparing all the different studied groups. DG(14,0/22:1), stearamide, proline, and E,e-carotene-3,3'-dione were found altered in PRE, and their levels returned to those of a baseline control group 3-6 months after surgery. Furthermore, 3-galactosyllactose levels remained altered after intervention in some patients. This study provides unique insights into the metabolic profiles of LC patients after surgery at two different time points by combining complementary analytical methods.


Assuntos
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/diagnóstico , Recidiva Local de Neoplasia , Metabolômica/métodos , Espectrometria de Massas/métodos , Metaboloma
3.
Preprint em Inglês | bioRxiv | ID: ppbiorxiv-501163

RESUMO

Since the emergence of the SARS-CoV-2 virus, we have witnessed a revolution in vaccine development with the rapid emergence and deployment of both traditional and novel vaccine platforms. The inactivated CoronaVac vaccine and the mRNA-based Pfizer/BNT162b2 vaccine are among the most widely distributed vaccines, both demonstrating high, albeit variable, vaccine effectiveness against severe COVID-19 over time. Beyond the ability of the vaccines to generate neutralizing antibodies, antibodies can attenuate disease via their ability to recruit the cytotoxic and opsinophagocytic functions of the immune response. However, whether Fc-effector functions are induced differentially, wane with different kinetics, and are boostable, remains unknown. Here, using systems serology, we profiled the Fc-effector profiles induced by the CoronaVac and BNT162b2 vaccines, over time. Despite the significantly higher antibody functional responses induced by the BNT162b2 vaccine, CoronaVac responses waned more slowly, albeit still found at levels below those present in the systemic circulation of BNT162b2 immunized individuals. However, mRNA boosting of the CoronaVac vaccine responses resulted in the induction of significantly higher peak antibody functional responses with increased humoral breadth, including to Omicron. Collectively, the data presented here point to striking differences in vaccine platform-induced functional humoral immune responses, that wane with different kinetics, and can be functionally rescued and expanded with boosting.

4.
J Geriatr Cardiol ; 19(5): 354-366, 2022 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-35722037

RESUMO

OBJECTIVES: Elderly patients show a higher incidence of ischemic and bleeding events after percutaneous transluminal coronary intervention (PCI). We sought to investigate outcomes in elderly patients treated with antithrombotic strategy guided by bleeding and ischemic risks after revascularization with last generation everolimus-eluting stent (EES). METHODS: Prospective multicenter registry including patients over 75 years revascularized with EES and antithrombotic therapy guided by clinical presentation, PCI complexity and PRECISE DAPT score. Co-primary safety endpoints were: (1) composite of cardiac death, myocardial infarction and stent thrombosis and; (2) bleeding (BARC 2-5). Primary efficacy endpoint was target lesion revascularization. A matched group of patients revascularized with current drug-eluting stents and no such tailored antithrombotic therapy was used as control. RESULTS: Finally, 1064 patients were included in SIERRA-75 cohort, 80.8 ± 4.2 years, 36.6% women, 71% acute coronary syndromes (ACS) and 53.6% complex PCI. Co-primary safety endpoint of major adverse cardiovascular events was met in 6.2%, co-primary safety endpoint of bleeding in 7.8% and primary efficacy endpoint of TKLR in 1.5%. The multivariable adjusted model showed no significant association of the prescribed short/long dual antiplatelet therapy (DAPT) durations with any endpoint suggesting a well tailored therapy. No stent thrombosis reported in the subgroup with 1-3 months DAPT duration. As compared to control group, bleeding BARC 2-5 was significantly lower in SIERRA-75 group (7.4% vs. 10.2%, P = 0.04) as well as the net safety-efficacy endpoint (14.3% vs. 18.5%, P = 0.02). CONCLUSIONS: In elderly population, the application of this risks-adjusted antithrombotic protocol after revascularization with last generation EES seems to be associated with an improved prognosis in terms of ischemic and bleeding outcomes.

5.
Catheter Cardiovasc Interv ; 99(3): 664-673, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34582631

RESUMO

OBJECTIVES: to test the safety and efficacy of intravascular imaging and specifically optical coherence tomography (OCT) as a diagnostic tool for left main angioplasty and analyze the mid-term outcome accordingly. BACKGROUND: Clinical data and international guidelines recommend the use of intravascular imaging ultrasound (IVUS) to guide left main (LM) angioplasty. Despite early experience using OCT in this setting is encouraging, the evidence supporting its use is still limited. METHODS: ROCK II is a multicenter, investigator-driven, retrospective European study to compare the performance of IVUS and OCT versus angiography in patients undergoing distal-LM stenting. The primary study endpoint was target-lesion failure (TLF) including cardiac death, target-vessel myocardial infarction and target-lesion revascularization. We designed this study hypothesizing the superiority of intravascular imaging over angiographic guidance alone, and the non-inferiority of OCT versus IVUS. RESULTS: A total of 730 patients, 377 with intravascular-imaging guidance (162 OCT, 215 IVUS) and 353 with angiographic guidance, were analyzed. The one-year rate of TLF was 21.2% with angiography and 12.7% with intravascular-imaging (p = 0.039), with no difference between OCT and IVUS (p = 0.26). Intravascular-imaging was predictor of freedom from TLF (HR 0.46; 95% CI 0.23-0.93: p = 0.03). Propensity-score matching identified three groups of 100 patients each with no significant differences in baseline characteristics. The one-year rate of TLF was 16% in the angiographic, 7% in the OCT and 6% in the IVUS group, respectively (p = 0.03 for IVUS or OCT vs. angiography). No between-group significant differences in the rate of individual components of TLF were found. CONCLUSIONS: Intravascular imaging was superior to angiography for distal LM stenting, with no difference between OCT and IVUS.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos
6.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21268378

RESUMO

Despite the dramatic spread of Omicron globally, even among highly vaccinated populations, death rates have not increased concomitantly. These data argue that alternative immune mechanisms, beyond neutralization, may continue to confer protection against severe disease. Beyond their ability to bind and block infection, antibodies contribute to control and clearance of multiple infections via their ability to direct antiviral immunity via Fc-effector mechanisms. Thus, here we probed the ability of vaccine induced antibodies, across three COVID-19 vaccines, to drive Fc-effector activity against Omicron. Despite the significant loss of IgM, IgA and IgG binding to the Omicron Receptor Binding Domain (RBD) across BNT162b2, mRNA-1273, and CoronaVac vaccines, stable isotype binding was observed across all of these vaccines to the Omicron Spike. Compromised RBD binding IgG was accompanied by a significant loss of cross RBD-specific antibody Fc{gamma}-receptor binding by the CoronaVac vaccine, but preservation of RBD-specific Fc{gamma}R2a and Fc{gamma}3a binding across the mRNA vaccines. Conversely, Spike-specific antibodies exhibited persistent binding to Fc{gamma}-receptors, across all three vaccines, albeit higher binding was observed with the mRNA vaccines, marked by a selective preservation of Fc{gamma}R2a and Fc{gamma}3a binding antibodies. Thus, despite the significant to near complete loss of Omicron neutralization across several vaccine platforms against Omicron, vaccine induced Spike-specific antibodies continue to recognize the virus and recruit Fc-receptors pointing to a persistent capacity for extra-neutralizing antibodies to contribute Omicron disease attenuation.

7.
Anal Chim Acta ; 1176: 338620, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34399890

RESUMO

Omic methodologies have become key analytical tools in a wide number of research topics such as systems biology, environmental analysis, biomedicine or food analysis. They are especially useful when they are combined providing a new perspective and a holistic view of the analytical problem. Methodologies for microbiota analysis have been mostly focused on genome sequencing. However, information provided by these metagenomic studies is limited to the identification of the presence of genes, taxa and their inferred functionality. To achieve a deeper knowledge of microbial functionality in health and disease, especially in dysbiosis conditions related to metal and metalloid exposure, the introduction of additional meta-omic approaches including metabolomics, metallomics, metatranscriptomics and metaproteomics results essential. The possible impact of metals and metalloids on the gut microbiota and their effects on gut-brain axis (GBA) only begin to be figured out. To this end new analytical workflows combining powerful tools are claimed such as high resolution mass spectrometry and heteroatom-tagged proteomics for the absolute quantification of metal-containing biomolecules using the metal as a "tag" in a sensitive and selective detector (e.g. ICP-MS). This review focus on current analytical methodologies related with the analytical techniques and procedures available for metallomics and microbiota analysis with a special attention on their advantages and drawbacks.


Assuntos
Microbiota , Espectrometria de Massas , Metabolômica , Metais , Proteômica
8.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21257197

RESUMO

The durability of circulating neutralizing antibody (nAb) responses to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and their boosting by vaccination remains to be defined. We show that outpatient and hospitalized SARS-CoV-2 seropositive individuals mount a robust neutralizing antibody (nAb) response that peaks at days 23 and 27 post-symptom onset, respectively. Although nAb titers remained higher in hospitalized patients, both study groups showed long-lasting nAb responses that can persist for up to 12 months after natural infection. These nAb responses in previously seropositive individuals can be significantly boosted through immunization with two doses of the CoronaVac (Sinovac) or one dose of the BNT162b2 (BioNTech/Pfizer) vaccines, suggesting a substantial induction of B cell memory responses. Noteworthy, three obese previously seropositive individuals failed to mount a booster response upon vaccination, warranting further studies in this population. Immunization of naive individuals with two doses of the CoronaVac vaccine or one dose of the BNT162b2 vaccine elicited similar levels of nAbs compared to seropositive individuals 4.2 to 13.3 months post-infection with SARS-CoV-2. Thus, this preliminary evidence suggests that both, seropositive and naive individuals, require two doses of CoronaVac to ensure the induction of robust nAb titers.

9.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-20183889

RESUMO

BackgroundCoronavirus disease 2019 (COVID-19) caused by the severe acute respiratory syndrome virus (SARS-CoV-2) is challenging global public health, due to an increasing demand for testing and the shortage of diagnostic supplies. Nasopharyngeal swab (NPS) is considered the optimal sample for SARS-CoV2 diagnosis and sputum (SPT) has been proposed as an economic alternative. However, the temporal concordance of diagnosis in NPS and SPT has not been addressed. MethodsThrough a longitudinal study we compared the shedding dynamics of SARS-CoV-2 RNA evaluated by RT-qPCR in serially collected SPT and NPS obtained from 82 ambulatory and hospitalized patients during acute infection and convalescence. The concordance during the follow-up and cost analysis between both collected specimens was evaluated. FindingsWe analyzed 379 samples, 177 NPS and 202 SPT. The highest proportion of positive samples was detected within the first 15 days after the symptoms onset. The median time of positivity was higher for NPS (median= 25 days) than SPT (median= 21 days). There was no significant difference in the median RT-qPCR CT values between both sample types. The temporal categorization of matched-paired samples indicated substantial correlation (r=0{middle dot}6023) and substantial agreement (87{middle dot}23%) during the first ten days since symptoms onset (kappa = 0{middle dot}697). A cost analysis demonstrated a significant saving when the SPT specimen was used. InterpretationSputum is a feasible and cost-saving alternative to NPS, providing an equivalent value for the detection and follow-up of SARS-CoV-2 RNA. FundingAgencia Nacional de Investigacion y Desarrollo (ANID) of Chile, NIH-NIAID USA.

10.
Eur Cardiol ; 15: 1-8, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32180829

RESUMO

Percutaneous revascularisation has evolved dramatically in the past few decades. The approach to the management of ischaemic heart disease has changed due to the development of new devices and techniques as well as the availability of new drugs and treatment strategies. Its use in combination with antiplatelet therapies has been essential to protect against stent thrombosis. The length of time this combination therapy is used has been modified in recent years and has been the subject of extensive research. The effect of prolonging the time it is taken or shortening it has been evaluated in different clinical conditions. In practice, the decisions regarding antithrombotic therapy after percutaneous coronary intervention are informed by the patient's profile and the characteristics of the procedures performed. In this article, we review the use of antiplatelet/anticoagulant therapy after percutaneous coronary intervention focusing on trials and guidelines addressing variable durations for combination regimens and the alternatives.

11.
J Biomed Opt ; 23(3): 1-14, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29560624

RESUMO

Polymeric endovascular implants are the next step in minimally invasive vascular interventions. As an alternative to traditional metallic drug-eluting stents, these often-erodible scaffolds present opportunities and challenges for patients and clinicians. Theoretically, as they resorb and are absorbed over time, they obviate the long-term complications of permanent implants, but in the short-term visualization and therefore positioning is problematic. Polymeric scaffolds can only be fully imaged using optical coherence tomography (OCT) imaging-they are relatively invisible via angiography-and segmentation of polymeric struts in OCT images is performed manually, a laborious and intractable procedure for large datasets. Traditional lumen detection methods using implant struts as boundary limits fail in images with polymeric implants. Therefore, it is necessary to develop an automated method to detect polymeric struts and luminal borders in OCT images; we present such a fully automated algorithm. Accuracy was validated using expert annotations on 1140 OCT images with a positive predictive value of 0.93 for strut detection and an R2 correlation coefficient of 0.94 between detected and expert-annotated lumen areas. The proposed algorithm allows for rapid, accurate, and automated detection of polymeric struts and the luminal border in OCT images.


Assuntos
Vasos Coronários/diagnóstico por imagem , Procedimentos Endovasculares/instrumentação , Tomografia de Coerência Óptica/métodos , Algoritmos , Humanos , Polímeros/química , Desenho de Prótese , Tomografia de Coerência Óptica/instrumentação
12.
Int Conf Bioinform Biomed Eng ; 2017: 297-302, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30147989

RESUMO

Bioresorbable vascular scaffolds (BVS), the next step in the continuum of minimally invasive vascular interventions present new opportunities for patients and clinicians but challenges as well. As they are comprised of polymeric materials standard imaging is challenging. This is especially problematic as modalities like optical coherence tomography (OCT) become more prevalent in cardiology. OCT, a light-based intracoronary imaging technique, provides cross-sectional images of plaque and luminal morphology. Until recently segmentation of OCT images for BVS struts was performed manually by experts. However, this process is time consuming and not tractable for large amounts of patient data. Several automated methods exist to segment metallic stents, which do not apply to the newer BVS. Given this current limitation coupled with the emerging popularity of the BVS technology, it is crucial to develop an automated methodology to segment BVS struts in OCT images. The objective of this paper is to develop a novel BVS strut detection method in intracoronary OCT images. First, we preprocess the image to remove imaging artifacts. Then, we use a K-means clustering algorithm to automatically segment the image. Finally, we isolate the stent struts from the rest of the image. The accuracy of the proposed method was evaluated using expert estimations on 658 annotated images acquired from 7 patients at the time of coronary arterial interventions. Our proposed methodology has a positive predictive value of 0.93, a Pearson Correlation coefficient of 0.94, and a F1 score of 0.92. The proposed methodology allows for rapid, accurate, and fully automated segmentation of BVS struts in OCT images.

13.
Catheter Cardiovasc Interv ; 88(3): E67-73, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26526783

RESUMO

OBJECTIVES: In this study we sought to evaluate coverage and apposition of Synergy™ stent at 3 and 6 months after implantation. BACKGROUND: The Pt-Cr everolimus-eluting stent with abluminal bioabsorbable polymer (Synergy™) is a new generation drug-eluting stent with features potentially favoring an early healing process which could make safe a shorter period of dual antiplatelet-therapy treatment. METHODS: Prospective, two-centers study enrolling patients with similar lesions treated with Synergy™ stents undergoing examination with OCT at 3 and 6 months in the respective centers. Blinded analysis was done at a core lab. Co-primary endpoints were proportion of struts with coverage and with apposition at 3 and 6 months. RESULTS: Finally, 22 patients (30 stents) in the 3 months group and 20 patients (30 stents) in the 6 months group were included. There were no significant differences between groups regarding clinical, angiographic measurements, and procedural data. The rate of strut coverage was 94.5% at 3 months and 96.6% at 6 months (P < 0.001), the rates of apposition were 93.8% and 96.2%, respectively, (P < 0.001), the proportion of uncovered but apposed struts was 2.5% and 1.9% (P = 0.03) and the proportion of uncovered and malapposed struts was 3% and 1.8%, respectively (P < 0.001). The maximal area of malapposition related with uncovered struts was 0.43 ± 0.4 mm(2) at 3 months and 0.14 ± 0.2 mm(2) at 6 months (P = 0.001). CONCLUSIONS: The everolimus-eluting stent with absorbable polymer, Synergy™, is associated to a high degree of intimal coverage and apposition at 3 months after implantation with additional increase at 6 months. © 2015 Wiley Periodicals, Inc.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Tomografia de Coerência Óptica , Cicatrização/efeitos dos fármacos , Idoso , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Espanha , Fatores de Tempo , Resultado do Tratamento
15.
J Agric Food Chem ; 57(1): 38-45, 2009 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-19093878

RESUMO

The efficiency of enzymatic hydrolysis and leaching with water using accelerated solvent extraction (ASE) or boiling was investigated for quantitative Se speciation in selenized potatoes using reversed phase HPLC coupled to ICP-MS. Preliminary identification of selenomethionine (SeMet), Se-methylselenocysteine (SeMeCys), and selenate in extracts of potato skin and flesh was achieved using complementary reversed phase and anion-exchange HPLC-ICP-MS and retention time matching with standards. The quantitative speciation data revealed a higher percentage of selenomethionine (73% of the total Se) found in the flesh in comparison with skin (containing 21% of the total Se as SeMet). ASE and boiling in water were found to be similar in terms of Se extraction efficiency and profiles. However, ASE was found to be more efficient than boiling with respect to sample cleanup and reduced sample handling. The presence of SeMet at parts per billion levels in selenized potatoes was confirmed by reversed phase HPLC with online ESI MS/MS.


Assuntos
Cromatografia Líquida de Alta Pressão , Temperatura Alta , Compostos de Selênio/análise , Selênio/administração & dosagem , Solanum tuberosum/química , Espectrometria de Massas por Ionização por Electrospray , Alimentos Fortificados/análise , Hidrolisados de Proteína , Selênio/análise , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...