Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Physiother Theory Pract ; 32(6): 489-493, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27253194

RESUMO

OBJECTIVE: To compare the PEFs in healthy, young, non-active subjects in seated, supine, and prone postures. METHODS: A total of 30 healthy volunteers (15 male, mean age 22.7 years, non-smokers, sedentary) underwent a physical examination, spirometry to confirm normal pulmonary function, and PEF using the Mini-Wright Peak Flow Meter while wearing a nose clip. PEF measurements were repeated three times in each of three positions (seated, prone, and supine) in random order and differed by less than 20 L/min for a given position. Paired Student's t-tests were used to analyze the results, and the significance level was set at 5%. RESULTS: The PEF values obtained when the study participants were in a seated position (481.0 ± 115.1 L/min) were higher than those obtained when participants were in prone (453.7 ± 112.1 L/min) or supine (453.2 ± 114.3 L/min) positions (p < 0.05). No significant difference in PEF values was observed between the prone and supine positions. CONCLUSION: Body posture affects PEF in healthy, young, non-active subjects. PEFs are higher when subjects are in a seated position compared to prone or supine positions, but no difference in PEF is observed between the prone and supine positions.


Assuntos
Pulmão/fisiologia , Pico do Fluxo Expiratório , Decúbito Ventral , Decúbito Dorsal , Adulto , Fatores Etários , Estudos Transversais , Feminino , Volume Expiratório Forçado , Voluntários Saudáveis , Humanos , Masculino , Comportamento Sedentário , Espirometria , Capacidade Vital , Adulto Jovem
3.
Respir Care ; 58(12): 2101-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23674811

RESUMO

BACKGROUND: Individuals with bronchiectasis exhibit colonization and infection of the respiratory system, with a consequent alteration of the macroscopic appearance of secretions, which ranges from mucoid to purulent. Purulence is related to the structural conformation, rheological profile, and transport indexes of mucus. We analyzed and compared the transport properties of respiratory secretions with mucoid appearance versus those with purulent appearance in patients with bronchiectasis and in subjects without lung disease. METHODS: In a simulated cough machine we assessed the mucociliary transport and contact angle of 32 mucoid and 19 purulent samples from subjects with bronchiectasis, and 21 samples from subjects without lung disease. RESULTS: Mucociliary transport was lower in the mucoid samples (0.78 ± 0.22) and in the purulent samples (0.73 ± 0.22) than in the samples from subjects without lung disease (1 ± 0.19). The purulent samples had less displacement in the simulated cough machine (7.57 ± 3 cm) than did the mucoid samples (23 ± 15 cm) or the samples from subjects without lung disease (34 ± 8.4 cm), as did the mucoid samples compared to the samples from subjects without lung disease. The purulent samples had a higher contact angle (25 ± 6.1°) than the mucoid samples (17 ± 7.8°) or the samples from subjects without lung disease (10 ± 2.5°), as did the mucoid samples compared to the samples from subjects without lung disease. CONCLUSIONS: Respiratory secretions in individuals with bronchiectasis have poor transport properties, which manifest as reduced mucociliary transport, reduced mucus transport by cough, and higher contact angle. These features were more accentuated in the purulent samples. This simple classification can be used by therapists to plan treatments, and by researchers to obtain more homogeneity between groups of subjects.


Assuntos
Bronquiectasia , Depuração Mucociliar , Muco/metabolismo , Infecções Respiratórias , Escarro/metabolismo , Supuração , Adulto , Idoso , Bronquiectasia/complicações , Bronquiectasia/diagnóstico , Bronquiectasia/fisiopatologia , Tosse/fisiopatologia , Feminino , Humanos , Masculino , Seleção de Pacientes , Sistema Respiratório/fisiopatologia , Infecções Respiratórias/diagnóstico , Infecções Respiratórias/etiologia , Infecções Respiratórias/fisiopatologia , Manejo de Espécimes/métodos , Supuração/complicações , Supuração/diagnóstico , Supuração/fisiopatologia
4.
Respir Med ; 105(9): 1316-21, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21641196

RESUMO

BACKGROUND: The Flutter(®)VRP1 combines high frequency oscillation and positive expiratory pressure (PEP). OBJECTIVE: To separately evaluate the effect of the Flutter(®)VRP1 components (high frequency oscillation and PEP) on mucus transportability in patients with bronchiectasis. METHODS: Eighteen patients with bronchiectasis received sessions with the Flutter(®)VRP1 or PEP for 30 min daily in a randomized, crossover study. The treatment duration was four weeks with one of the therapies, one week of a "wash-out" period and followed by four more weeks with the other treatment. Weekly secretion samples were collected and evaluated for mucociliary relative transport velocity (RTV), displacement in a simulated cough machine (SCM) and contact angle measurement (CAM). For the proposed comparisons, a linear regression model was used with mixed effects with a significance level of 5%. RESULTS: The Flutter(®)VRP1 treatment resulted in greater displacement in SCM and lower CAM when comparing results from the first (9.6 ± 3.4 cm and 29.4 ± 5.7°, respectively) and fourth weeks of treatment (12.44 ± 10.5 cm and 23.28 ± 6.2°, respectively; p < 0.05). There was no significant difference in the RTV between the treatment weeks for either the Flutter(®)VRP1 or PEP. CONCLUSION: The use of the Flutter(®)VRP1 for four weeks is capable of altering the respiratory secretion transport properties, and this alteration is related to the high frequency oscillation component.


Assuntos
Bronquiectasia/fisiopatologia , Oscilação da Parede Torácica/instrumentação , Pulmão/fisiopatologia , Depuração Mucociliar , Vibração , Bronquiectasia/terapia , Oscilação da Parede Torácica/métodos , Estudos Cross-Over , Desenho de Equipamento , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Muco , Respiração com Pressão Positiva/instrumentação , Respiração com Pressão Positiva/métodos , Resultado do Tratamento
5.
J Bras Pneumol ; 36(5): 545-53, 2010.
Artigo em Inglês, Português | MEDLINE | ID: mdl-21085819

RESUMO

OBJECTIVE: To analyze and compare the transport properties of respiratory secretions, classified by selected parameters, in individuals with bronchiectasis unrelated to cystic fibrosis. METHODS: We collected mucus samples from 35 individuals with bronchiectasis unrelated to cystic fibrosis. The samples were first classified by their surface properties (adhesive or nonadhesive), as well as by their aspect (mucoid or purulent). We then tested the samples regarding relative transport velocity (RTV), displacement in a simulated cough machine (SCM), and contact angle (CA). For the proposed comparisons, we used ANOVA models, with a level of significance set at 5%. RESULTS: In comparison with nonadhesive samples, adhesive samples showed significantly less displacement in the SCM, as well as a significantly higher CA (6.52 ± 1.88 cm vs. 8.93 ± 2.81 cm and 27.08 ± 6.13º vs. 22.53 ± 5.92º, respectively; p < 0.05 for both). The same was true in the comparison between purulent and mucoid samples (7.57 ± 0.22 cm vs. 9.04 ± 2.48 cm and 25.61 ± 6.12º vs. 21.71 ± 5.89º; p < 0.05 for both). There were no significant differences in RTV among the groups of samples, although the values were low regardless of the surface properties (adhesive: 0.81 ± 0.20; nonadhesive: 0.68 ± 0.24) or the aspect (purulent: 0.74 ± 0.22; mucoid: CONCLUSIONS: The respiratory secretions of patients with bronchiectasis showed decreased mucociliary transport. Increased adhesiveness and purulence cause the worsening of transport properties, as demonstrated by the lesser displacement in the SCM and the higher CA.


Assuntos
Bronquiectasia/fisiopatologia , Depuração Mucociliar/fisiologia , Muco/fisiologia , Adesividade , Adulto , Idoso , Idoso de 80 Anos ou mais , Secreções Corporais/fisiologia , Bronquiectasia/complicações , Feminino , Humanos , Pulmão/metabolismo , Masculino , Pessoa de Meia-Idade , Supuração/fisiopatologia
6.
J. bras. pneumol ; J. bras. pneumol;36(5): 545-553, set.-out. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-564196

RESUMO

OBJETIVO: Analisar e comparar as propriedades de transporte de secreções respiratórias, classificadas através de parâmetros selecionados, de indivíduos com bronquiectasias não secundárias à fibrose cística. MÉTODOS: Foram avaliadas amostras de muco respiratório, classificadas como com propriedades de superfície adesivas ou não adesivas, assim como com aspecto mucoide ou purulento, de 35 participantes com bronquiectasias não secundárias à fibrose cística, quanto a velocidade relativa de transporte (VRT), deslocamento em máquina simuladora de tosse (MST) e ângulo de contato (AC). Para as comparações propostas, foram utilizados modelos de ANOVA, com nível de significância estabelecido em 5 por cento. RESULTADOS: Houve uma diminuição significativa no deslocamento em MST, assim como um aumento significativo no AC, das amostras adesivas quando comparadas às não adesivas (6,52 ± 1,88 cm vs. 8,93 ± 2,81 cm e 27,08 ± 6,13º vs. 22,53 ± 5,92º, respectivamente; p < 0,05 para ambos). O mesmo ocorreu na comparação entre as amostras purulentas e mucoides (7,57 ± 0,22 cm vs. 9,04 ± 2,48 cm e 25,61 ± 6,12º vs. 21,71 ± 5,89º; p < 0,05 para ambos). Não houve diferença na VRT entre os grupos, embora os valores estivessem diminuídos, independentemente da adesividade (adesivas: 0,81 ± 0,20; não adesivas: 0,68 ± 0,24) ou do aspecto (purulentas: 0,74 ± 0,22; mucoides: 0,82 ± 0,22) das amostras. CONCLUSÕES: A secreção respiratória de pacientes com bronquiectasia apresentou uma diminuição do transporte ciliar. Maior adesividade e purulência favorecem a piora das propriedades de transporte, demonstradas pela diminuição do deslocamento em MST e pelo aumento do AC.


OBJECTIVE: To analyze and compare the transport properties of respiratory secretions, classified by selected parameters, in individuals with bronchiectasis unrelated to cystic fibrosis. METHODS: We collected mucus samples from 35 individuals with bronchiectasis unrelated to cystic fibrosis. The samples were first classified by their surface properties (adhesive or nonadhesive), as well as by their aspect (mucoid or purulent). We then tested the samples regarding relative transport velocity (RTV), displacement in a simulated cough machine (SCM), and contact angle (CA). For the proposed comparisons, we used ANOVA models, with a level of significance set at 5 percent. RESULTS: In comparison with nonadhesive samples, adhesive samples showed significantly less displacement in the SCM, as well as a significantly higher CA (6.52 ± 1.88 cm vs. 8.93 ± 2.81 cm and 27.08 ± 6.13º vs. 22.53 ± 5.92º, respectively; p < 0.05 for both). The same was true in the comparison between purulent and mucoid samples (7.57 ± 0.22 cm vs. 9.04 ± 2.48 cm and 25.61 ± 6.12º vs. 21.71 ± 5.89º; p < 0.05 for both). There were no significant differences in RTV among the groups of samples, although the values were low regardless of the surface properties (adhesive: 0.81 ± 0.20; nonadhesive: 0.68 ± 0.24) or the aspect (purulent: 0.74 ± 0.22; mucoid: CONCLUSIONS: The respiratory secretions of patients with bronchiectasis showed decreased mucociliary transport. Increased adhesiveness and purulence cause the worsening of transport properties, as demonstrated by the lesser displacement in the SCM and the higher CA.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Bronquiectasia/fisiopatologia , Depuração Mucociliar/fisiologia , Muco/fisiologia , Adesividade , Secreções Corporais/fisiologia , Bronquiectasia/complicações , Pulmão , Supuração/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA