Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nephrol Dial Transplant ; 29(6): 1239-46, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24557989

RESUMO

BACKGROUND: Whether convective therapies allow better control of serum phosphate (P) is still undefined, and no data are available concerning on-line haemofiltration (HF). The objectives of the study are to evaluate the effect of convective treatments (CTs) on P levels in comparison with low-flux haemodialysis (HD) and to evaluate the correlates of serum phosphate in a post hoc analysis of a randomized clinical trial. METHODS: This analysis was performed in the database of a multicentre, open label and randomized controlled study in which 146 chronic HD patients from 27 Italian centres were randomly assigned to HD (70 patients) or CTs: on-line pre-dilution HF (36 patients) or on-line pre-dilution haemodiafiltration (40 patients). RESULTS: CTs did not affect P (P = 0.526), calcium (Ca) (P = 0.849) and parathyroid hormone levels (P = 0.622). P levels were associated with the use of phosphate binders including aluminium-based phosphate binders (P < 0.001) and sevelamer (P < 0.001), pre-dialysis bicarbonate levels (P < 0.001) and pre-dialysis blood K levels (P < 0.001). On multivariate analysis (generalized linear model), serum P was again largely unassociated with CTs (P = 0.631). Notably, participating centres were by far the strongest independent correlate of serum P, explaining 45.3% of the variance of serum P over the trial and this association was confirmed at multivariate analysis. Bicarbonate (P < 0.001) and, to a weaker extent, serum K (P = 0.032) were independently related to serum P. CONCLUSIONS: In comparison with low-flux HD, CTs did not significantly affect serum P levels. Participating centres were the main source of P variability during the trial followed by treatment with phosphate binders, serum bicarbonate and, to a weak extent, serum potassium levels (ClinicalTrials.gov Identifier: NCT011583309).


Assuntos
Falência Renal Crônica/sangue , Fosfatos/sangue , Terapia de Substituição Renal , Idoso , Bicarbonatos/sangue , Cálcio/sangue , Feminino , Hemodiafiltração/efeitos adversos , Hemofiltração , Humanos , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Hormônio Paratireóideo/sangue , Diálise Renal
2.
Infect Control Hosp Epidemiol ; 23(6): 338-41, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12083239

RESUMO

OBJECTIVE: To describe nosocomial transmission of malaria from patient to patient via blood exposure. PATIENTS: A 56-year-old man was admitted to an Italian hospital with fever and Plasmodium falciparum parasitemia, but with no risk factors for malaria. Twenty days earlier, he had been admitted for bronchopulmonary disease to the hospital's intensive care unit, where a woman with P. falciparum malaria acquired abroad was present. METHODS: We reviewed both patients' medical records and searched for mosquitoes in the hospital and on the grounds. We interviewed the staff about patient care practices potentially involving contact with blood. The genetic identities of strains were determined by genotyping of the DNA extracted from blood. RESULTS: Molecular genotyping showed that the two strains were identical. The only invasive procedures performed on both patients by the same staff on the same shift were capillary blood sampling by finger stick, intravenous drug administration, and substitution of total parenteral nutrition bags and intravenous sets. The fingerstick device used was designed to prevent person-to-person transmission of blood-borne infections, and the staff interviews did not reveal any incorrect use of aseptic techniques. The likely source of infection was identified during a training course 6 months later: a nurse reported that, when collecting blood, she placed patients' fingers directly on the blood glucose meter, a practice she had learned from a poster advertising the device. CONCLUSIONS: A nosocomial case of malaria was ascertained, which was likely due to patient-to-patient transmission via a contaminated blood glucose meter. Incomplete instructions for the meter seem to have played a role in this case.


Assuntos
Transmissão de Doença Infecciosa , Contaminação de Equipamentos , Malária Falciparum/transmissão , Infecção Hospitalar , Feminino , Humanos , Unidades de Terapia Intensiva , Itália , Malária Falciparum/parasitologia , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...