Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 59(6): 546-550, 2024 Jun 09.
Artigo em Chinês | MEDLINE | ID: mdl-38808414

RESUMO

Dental and facial esthetics is an essential part of modern stomatology. With the development of science and technology and the advancement of interdisciplinary studies, the research of robot technology in the field of dental and facial esthetics is becoming more extensive, and its clinical applications are gradually increasing. This article provides insights into the research and application of robot technology in dental hard tissue esthetics, periodontal soft tissue esthetics, dentition space esthetics, and maxillofacial esthetics. It also highlights the current limitations and development trends and provides references for future research and application of robots in oral esthetics.


Assuntos
Estética Dentária , Face , Robótica , Humanos , Face/anatomia & histologia
2.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 57(10): 1009-1014, 2022 Oct 09.
Artigo em Chinês | MEDLINE | ID: mdl-36266073

RESUMO

Severely worn dentition seriously affects patient's esthetics and function. Its etiology is complex, differential diagnosis is difficult, treatment process involves multiple disciplines, and requires esthetic and functional rehabilitation. A "8-step sequential treatment" for the rehabilitation of severely worn dentition has been established. In recent years, digital technology has been increasingly applied to the esthetic and functional rehabilitation of severely worn dentition. This article will describe the application of digital methods in the 8-step sequential treatment of severely worn dentition.


Assuntos
Desgaste dos Dentes , Humanos , Desgaste dos Dentes/reabilitação , Estética Dentária , Dentição , Tecnologia Digital
3.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 57(4): 346-351, 2022 Apr 09.
Artigo em Chinês | MEDLINE | ID: mdl-35368160

RESUMO

Objective: To evaluate the pink and white esthetics of conventional and socket shield technique (SST) immediate implant restoration. Methods: Thirty volunteers were recruited according to preset criteria, and were assigned to 3 groups. Natural teeth group (ten undergraduates or postgraduates from Peking University School and Hospital of Stomatology in January 2020, n=10): all volunteers' maxillary anterior teeth were natural teeth with healthy gingiva, and none of the teeth were restored by crowns or composite. Conventional group and SST group (patients had a maxillary central incisor immediate implant placed in Department of Prosthodontics, Peking University School and Hospital of Stomatology during October 2016 to January 2021, n=10 for each group): the volunteer had an unrestored natural maxillary central incisor, and the contralateral maxillary central incisor was restored by conventional or SST immediate implant placement, temporization and all ceramic final restoration, photos were taken 12 months post-surgery. Three groups of evaluators namely layperson (staff from Second Clinical Division of Peking University School and Hospital of Stomatology and 2 family members, n=10), dental students (class 2015 undergraduates from Peking University School and Hospital of Stomatology, n=10) and prosthodontists (from Department of Prosthodontics, Peking University School and Hospital of Stomatology, n=10) were invited to assess the esthetics using pink esthetic score (PES) and white esthetic score (WES). The results were statistically analyzed. Results: PES and WES of natural teeth group [9(8, 10) and 8(7, 10)] were significantly higher than conventional group [7(6,8) and 7(6,9)] (H=287.08, 132.79,P<0.01) and SST group [7(6, 9) and 8(7, 9)] (H=216.01, 101.21, P<0.01). SST group yielded higher PES than the conventional group (H=-71.06, P<0.01), yet had similar WES (H=-31.57, P>0.05). Dental students had significant lower PES and WES than prosthodontists (H=-120.90, -218.86, P<0.01) and layperson (H=-109.55, 134.97, P<0.01). Prosthodontists and layperson got similar PES (H=-11.36, P>0.05), however yielded different WES (H=-83.89, P<0.01). Conclusions: SST immediate implant placement obtained better pink esthetics than conventional protocol 12-month after implant surgery, profession may have significant impact on evaluators during pink and white esthetic evaluation.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Coroas , Estética Dentária , Humanos , Maxila/cirurgia , Resultado do Tratamento
4.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 57(4): 418-423, 2022 Apr 09.
Artigo em Chinês | MEDLINE | ID: mdl-35368170

RESUMO

Zirconia is widely used in the field of dentistry because of its superior mechanical and esthetic characteristics. However, the tetragonal zirconia polycrystal restorations commonly used in clinics will degrade at low temperatures in the oral environment, resulting in increased surface roughness, microcracks, and decreased mechanical properties. Low-temperature degradation of zirconia can be affected by grain size, stress, stabilizer content and type, surface treatment, sintering conditions, and other factors. Through a literature review and analysis, this review summarizes the research progress on the low-temperature degradation of zirconia in prosthetic dentistry to provide references for the improvement of zirconia in clinical and research applications.


Assuntos
Estética Dentária , Prostodontia , Cerâmica , Materiais Dentários , Teste de Materiais , Propriedades de Superfície , Temperatura , Ítrio/química , Zircônio
5.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(1): 83-88, 2022 Feb 18.
Artigo em Chinês | MEDLINE | ID: mdl-35165472

RESUMO

OBJECTIVE: To investigate the effect of a noval radio-frequency atmospheric-pressure glow discharge (RF-APGD) plasma jet on crosslinking of dentin collagen. METHODS: (1) Twenty intact third molars were collected. The middle dentin discs were prepared for each tooth by low-speed water-cooled Isomet saw, and then immersed in 10% (mass fraction) H3PO4 solution for 16 h to obtain fully demine-ralized dentin collagen. The twenty dentin discs were then randomly divided into five groups. The control group was untreated while the four experimental groups were treated by plasma jet with gas temperature of 4 ℃ for different times (20 s, 30 s, 40 s, and 50 s). The structure and crosslinking degree of dentin collagen were characterized by attenuated total reflection-Fourier transform infrared spectroscopy. The surface morphology of demineralized dentin was observed by scanning electron microscope, and the microstructure was observed by transmission electron microscope. (2) Fourty non-caries third molars were collected to prepare 5 g fine dentin powder, then completely demineralized with 10% H3PO4 solution. The control group was untreated, while the four experimental groups were treated by plasma jet for 20 s, 30 s, 40 s and 50 s. The crosslinking degree of each group was determined by ninhydrin colorimetric method. (3) Forty intact third molars were collected to obtain dentin strips. Only two central symmetrical dentin strips (nasty 80) were taken from each tooth and immersed in 10% H3PO4 solution for 16 h to obtain fully demineralized dentin collagen. Eighty dentine collagen fiber strips were randomly divided into five groups. The control group was untreated and the axial surfaces of dentin collagen fiber strips in the expe-rimental groups were treated with the plasma jet for 20 s, 30 s, 40 s and 50 s. The ultimate tensile strength of dentin was measured by universal mechanical machine. RESULTS: (1) The surface morphology of demineralized dentin observed by scanning electron microscope showed that the network structure of collagen fibers on the surface of demineralized dentin treated with the plasma jet for 20 s, 30 s and 40 s could maintain the uncollapsed three-dimensional structure, and part of the microstructure was destroyed after plasma jet treated for 50 s. After being treated by plasma jet for 20 s, 30 s and 40 s, the three-dimensional structure was uncollapsed, and the typical periodic transverse pattern of natural type Ⅰ collagen fiber could be seen. The results of infrared spectra showed that the secondary conformation of dentin collagen fibers was the same as that of the control group after being treated with the plasma jet, and the intensity of amide band was significantly increased after being treated for 30 s and 40 s. (2) The results of ninhydrin crosslinking test showed that the crosslinking ratio of dentin collagen treated by plasma jet for 30 s and 40 s was the highest, and the difference was statistically significant (P < 0.05). (3) The results of dentin ultimate tensile strength showed that the control group was (1.67±0.24) MPa, and the plasma jet treated 20 s, 30 s, 40 s and 50 s groups were (4.21±0.15) MPa, (7.06±0.30) MPa, (7.32±0.27) MPa, and (6.87±0.17) MPa, which were significantly different from that of the control group (P < 0.05). CONCLUSION: The novel RF-APGD plasma jet treatment can promote the crosslinking degree of demineralized dentin collagen and improve their ultimate tensile strength.


Assuntos
Colagem Dentária , Adesivos Dentinários , Colágeno , Dentina , Microscopia Eletrônica de Varredura , Resistência à Tração
6.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(1): 140-145, 2022 Feb 18.
Artigo em Chinês | MEDLINE | ID: mdl-35165481

RESUMO

OBJECTIVE: To analyze the marginal roughness and marginal fitness of chairside computer-aided design and computer-aided manufacturing (CAD/CAM) laminate veneers with different materials and thicknesses, and to provide a reference for the clinical application of laminate veneers. METHODS: The butt-to-butt type laminate veneers were prepared on resin typodonts, the preparations were scanned, and the laminate veneers were manufactured by chairside CAD/CAM equipment. The laminate veneers were divided into four groups (n=9) according to the materials (glass-matrix ceramics and resin-matrix ceramics) and thickness (0.3 mm and 0.5 mm) of the veneers, with a total of 36. The marginal topo-graphies of each laminate veneer were digitally recorded by stereomicroscope, and the marginal rough-nesses of the laminate veneers were determined by ImageJ software. The marginal fitness of the laminate veneers was measured by a fit checker and digital scanning and measuring method. At the same time, the mechanical properties of glass-matrix ceramic and resin-matrix ceramic bars (n=20) were tested by a universal testing device. RESULTS: The marginal roughness of 0.3 mm and 0.5 mm glass-matrix ceramic laminate veneers was (24.48±5.55) µm and (19.06±5.75) µm, respectively, with a statistically significant difference (P < 0.001). The marginal roughness of 0.3 mm and 0.5 mm resin-matrix ceramic laminate veneers was (6.13±1.27) µm and (6.84±2.19) µm, respectively, without a statistically significant difference (P>0.05). The marginal roughness of the glass-matrix ceramic laminate veneers was higher than that of the resin-matrix ceramic laminate veneers with a statistically significant difference (P < 0.001). The marginal fitness of 0.3 mm and 0.5 mm glass-matrix ceramic laminate veneers were (66.30±26.71) µm and (85.48±30.44) µm, respectively. The marginal fitness of 0.3 mm and 0.5 mm resin-matrix ceramic laminate veneers were (56.42±19.27) µm and (58.36±8.33) µm, respectively. There was no statistically significant difference among the 4 groups (P>0.05). For glass-matrix ceramics, the flexural strength was (327.40±54.25) MPa, the flexural modulus was (44.40±4.39) GPa, and the modulus of resilience was (1.24±0.37) MPa. For resin-matrix ceramics, the flexural strength was (173.71±16.61) MPa, the flexural modulus was (11.88±0.51) GPa, and the modulus of resilience was (1.29±0.27) MPa. The flexural strength and modulus of glass-matrix ceramics were significantly higher than those of resin-matrix ceramics (P < 0.001), but there was no statistically significant difference in the modulus of resilience between the two materials (P>0.05). CONCLUSION: The marginal roughness of CAD/CAM glass-matrix ceramic laminate veneers is greater than that of resin-matrix ceramic laminate veneers, but there was no statistically significant difference in marginal fitness among them. Increasing the thickness can reduce the marginal roughness of glass-matrix ceramic laminate veneers, but has no effect on the marginal roughness of resin-matrix ceramic laminate veneers.


Assuntos
Cerâmica , Desenho Assistido por Computador , Porcelana Dentária , Facetas Dentárias , Teste de Materiais , Propriedades de Superfície
7.
Beijing Da Xue Xue Bao Yi Xue Ban ; 53(5): 977-982, 2021 Oct 18.
Artigo em Chinês | MEDLINE | ID: mdl-34650305

RESUMO

OBJECTIVE: To evaluate the morphology accuracy of direct occlusal veneer using two types of modified stamp-technique, comparing the Results of two types of stamp and different composite resin. METHODS: Model scanner was used to get the original data from the standard resin teeth in plastic model. Two types of stamps were made: solid silicon stamp and transparent silicon stamp. In the study, 54 resin tooth were randomly divided into 9 groups: Groups 1-8 were restored by direct composite resin, using general and bulk-filled composite resin in occlusal veneer (1 mm or 2 mm) with two types of stamp-technique (the solid silicon, and the transparent silicon), and the control group was restored by indirect way using CAD/CAM composite resin restoration by biocopy technique to mimic the original shape of the teeth. After the resin teeth were prepared for occlusal veneer, the direct and indirect composite resins were restored. After the restoration was finished, the data were obtained again by the same model scanner in the plastic model. 3D comparisons were made using the original and restoration data, the average difference and the root mean square of difference (RMS) were recoded from the software. The RMS of all the groups were analyzed using one way ANOVA (α=0.05). RESULTS: The RMS of occlusal surface in solid silicon stamp group was (0.136±0.031) mm, in transparent silicon group was (0.130±0.024) mm, and in control group was (0.130±0.009) mm. There were no significant difference. While the RMS of buccal/lingual surface in solid silicon stamp group was the smallest [(0.135±0.020) mm, P < 0.05], and in transparent silicon group it was (0.147±0.021) mm, and control group (0.153±0.014) mm. The general composite resin using the two types of stamp had the largest occlusal RMS in 2 mm occlusal veneer, which were significantly larger than control group (P < 0.05). CONCLUSION: The direct occlusal veneer using two types of modified "stamp-technique" had relatively good morphology accuracy. Direct occlusal veneer using bulk-filled composite resin made with two types of stamp technique had even more accurate morphology than using general composite resin. The solid silicon stamp had a better morphology accuracy in buccal/lingual surface than the transparent silicon stamp.


Assuntos
Fraturas dos Dentes , Dente , Resinas Compostas , Desenho Assistido por Computador , Restauração Dentária Permanente , Humanos , Teste de Materiais
14.
Beijing Da Xue Xue Bao Yi Xue Ban ; 53(3): 594-597, 2021 Jun 18.
Artigo em Chinês | MEDLINE | ID: mdl-34145867

RESUMO

OBJECTIVE: To observe the movement of posterior teeth after losing the interproximal and occlusal contacts in adults from the amount and speed of mesial-distal, buccal-lingual, occlusal-gingival and three-dimensional movements. METHODS: Twenty cases of metal post-core restoration from the Department of Prosthodontics, Peking University School and Hospital of Stomatology were recruited into this study, which was an observational study. The restored teeth had complete mesial, distal, and occlusal contacts before treatment. All the interproximal and occlusal contacts were removed during the preparation for the post-core. The three-dimensional positions of the post-core preparation were obtained by the intraoral scanner at the day of tooth preparation and that of post-core placement. The amounts of mesial-distal, buccal-lingual and occlusal-gingival tooth movement were measured in the software. On this basis, the amount of three-dimensional tooth movement was calculated. The speed of tooth movement was calculated based on the elapsed time between the two scans. RESULTS: Ten females and ten males with an average age of (29.5±4.9) years were recruited. The average elapsed time was (10.9±2.7) days. The amount of the mesial-distal tooth movement was (134.8±61.2) µm, of the buccal-lingual tooth movement was (110.3±39.5) µm, of the occlusal-gingival tooth movement was (104.8±57.5) µm, and of the three-dimensional tooth movement was (211.4±71.0) µm, respectively. The amounts of mesial-distal, buccal-lingual and three-dimensional tooth movements were larger in female than in male (P < 0.05). The speed of the mesial-distal tooth movement was (13.1±7.8) µm/d, of the buccal-lingual tooth movement was (10.6±4.5) µm/d, of the occlusal-gingival tooth movement was (10.1±6.8) µm/d, and of the three-dimensional tooth movement was (20.5±9.7) µm/d, respectively. The speed of mesial-distal and buccal-lingual tooth movements were larger in female than in male (P < 0.05). The speed of three-dimensional tooth movement was slightly larger in female than in male, while there was no significant difference between different genders (P>0.05). CONCLUSION: The three-dimensional position of posterior teeth changed after losing the interproximal and occlusal contacts in adults. The female had more significant and faster tooth movement than the male.


Assuntos
Dente , Adulto , Feminino , Humanos , Masculino , Software , Técnicas de Movimentação Dentária , Adulto Jovem
19.
Beijing Da Xue Xue Bao Yi Xue Ban ; 52(6): 1130-1134, 2020 Dec 18.
Artigo em Chinês | MEDLINE | ID: mdl-33331326

RESUMO

OBJECTIVE: To analyze the esthetic proportions of maxillary anterior teeth in term of the apparent widths proportion of the adjacent teeth and width/height ratio of the clinical crown in 120 Chinese adults. METHODS: Maxillary gypsum casts were obtained from the dental laboratories of stomatological hospitals in North China, Southeast China, and Southwest China, according to the inclusion criteria and exclusion criteria. Standardized digital photographs of each cast were recorded. The apparent widths and actual widths and heights of the central incisors, lateral incisors and canines were determined by ImageJ software for the calculation of apparent widths proportion of the adjacent teeth and width/height ratio of the clinical crown. The ideal apparent widths proportion (Golden proportion and Preston proportion) and width/height ratio (0.80) were tested. The gender, arch side, and regional differences were investigated. RESULTS: The apparent widths proportion of the lateral/central incisor was 0.724±0.047, of the canine/lateral incisor was 0.814±0.092. The width/height ratio of the central incisor was 0.848±0.072, of the lateral incisor was 0.834±0.094, of the canine was 0.883±0.098. The esthetic proportions were different from the predicted ideal ratio (P < 0.001). The apparent widths proportion of lateral/central incisor was significantly larger in the right side than that in the left side (0.730± 0.044 vs. 0.718±0.050), and was significantly smaller in North China than that in Southwest China (0.711±0.051 vs. 0.731±0.044). The width/height ratio of the central incisor was significantly larger in the female than that in the male (0.855±0.074 vs. 0.835±0.068), and in the right side than that in the left side (0.855±0.073 vs. 0.842±0.072). The width/height ratio of the lateral incisor was significantly larger in the female than that in the male (0.843±0.097 vs. 0.817±0.084). CONCLUSION: The apparent widths proportion of adjacent teeth and the width/height ratio of the clinical crown in Chinese adults are different from the foreigner's. The esthetic proportion parameters have significant population specificity, and the measurements cannot be generalized as well as it should be applied with caution.


Assuntos
Dente Canino , Coroa do Dente , Adulto , Povo Asiático , China , Estética , Estética Dentária , Feminino , Humanos , Masculino , Maxila/anatomia & histologia , Odontometria , Coroa do Dente/anatomia & histologia
20.
Beijing Da Xue Xue Bao Yi Xue Ban ; 52(5): 948-951, 2020 Oct 18.
Artigo em Chinês | MEDLINE | ID: mdl-33047735

RESUMO

OBJECTIVE: To assess the effects of loupes and microscope on the posture of prosthodontists when preparing the laminate veneer, and to assess the clinical value of loupes and microscope from the ergonomic aspects. METHODS: Twenty young prosthodontists from Department of Prosthodontics, Peking University School and Hospital of Stomatology were recruited into this study, which was a prospective, single blind, self-control trials. The research hypothesis was concealed and the participants were deceived about the precise purpose of the study to counterbalance the lack of direct blinding. The prosthodontists prepared laminate veneers of open window type in the artificial dental model, under routine visual field (control group), 2.5× headwear loupes (loupes group), and 8× operating microscope (microscopic group) by turning. The participants were photographed from profile view and front view. Thereafter, the subjective assessment was performed by themselves using the visual analogue score (VAS). The expert assessment was performed by two professors using modified-dental operator posture assessment instrument on the basis of photographs of the profile view and front view. RESULTS: The subjective assessment scores for the control group, loupes group and microscopic group were 4.55±1.96, 7.90±1.12, and 9.00±0.92, respectively. There was significant difference between the three groups' subjective scores (P < 0.05). The expert assessment scores for the control group, loupes group and microscopic group were 16.38±1.52, 15.15±1.30, and 13.60±0.88, respectively. There was significant difference between the three groups' expert assessment scores (P < 0.05). Specifically, the three groups' expert assessment scores were significantly different (P < 0.05) in trunk position (front to back) (1.33±0.41, 1.03±0.11, 1.00±0.00), head and neck position (front to back) (2.75±0.38, 2.13±0.36, 1.23±0.38), elbows level (1.38±0.43, 1.40±0.45, 1.13±0.22), and shoulders level (1.43±0.41, 1.23±0.34, 1.13±0.28). Thereinto, the microscopic group was better than loupes group in head and neck position (front to back) and elbows level (P < 0.05). CONCLUSION: Loupes and microscope improve the posture of the prosthodontist when preparing the laminate veneer, in which the microscope is better than loupes. Therefore, the magnification devices have clinical value from the ergonomic aspects.


Assuntos
Ergonomia , Postura , Odontólogos , Humanos , Estudos Prospectivos , Método Simples-Cego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...