1.
Chest ; 159(3): e167-e171, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33678287

RESUMO

CASE PRESENTATION: A 40-year-old woman presented with recurrent syncope. She reported multiple (>20) episodes of non-prodromal loss of consciousness, periodically provoked by physical exertion. One episode resulted in a nasal fracture due to the abrupt nature of her syncope. The characterization of each episode was inconsistent with a neurogenic seizure. Other causes of syncope (vasovagal, situational, carotid hypersensitivity, and orthostasis) were also deemed unlikely. On physical examination, a low-pitched, brief adventitious sound was appreciated after each S2 sound in the right lower sternal border. The remainder of the physical examination was unremarkable. Initial workup, including complete blood count, comprehensive metabolic panel, cardiac enzymes, and ECG yielded normal results. The chest radiograph did not show any gross cardiac or pulmonary parenchymal pathologic condition (Fig 1). Telemetry did not demonstrate any malignant arrhythmias, and video-guided EEG did not document any seizure activity.


Assuntos
Coristoma , Dissecação/métodos , Eletrocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Cardiopatias , Fígado , Síncope , Adulto , Coristoma/diagnóstico por imagem , Coristoma/fisiopatologia , Coristoma/cirurgia , Diagnóstico Diferencial , Eletroencefalografia/métodos , Feminino , Cardiopatias/diagnóstico , Cardiopatias/fisiopatologia , Cardiopatias/cirurgia , Humanos , Exame Físico/métodos , Recidiva , Síncope/diagnóstico , Síncope/etiologia , Síncope/fisiopatologia , Resultado do Tratamento , Veia Cava Inferior/diagnóstico por imagem
2.
Catheter Cardiovasc Interv ; 95(5): 914-919, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-31410958

RESUMO

OBJECTIVE: This study evaluated the impact of network latency on telestenting performance. BACKGROUND: The feasibility of long-distance robotic telestenting was recently demonstrated, yet the impact of network performance on telestenting remains unknown. METHODS: Ex vivo and in vivo telestenting models were constructed by connecting a robotic drive over a wired network to a robotic control system up to 103 miles away. During consecutive attempts to robotically wire a coronary artery, investigators randomly added signal latencies from 0 to 1,000 ms. Outcomes included wiring success, wiring time (time to advance wire to preselected target landmark), and perceived latency score (5 = imperceptible; 4 = noticeable but minor; 3 = noticeable; 2 = noticeable and major; 1 = unacceptable). RESULTS: Wiring success was achieved in 95 of 95 attempts in the ex vivo model and in 57 of 57 attempts in vivo. No significant difference in wiring time was observed across added latencies from 0 to 1,000 ms in the ex vivo (p = .64) or in vivo (p = .40) models. Compared to an added latency of 0 ms, perceived latency scores were not significantly different for added latencies of 150 and 250 ms (p = NS for both), but were significantly lower for latencies ≥400 ms (p < .001). CONCLUSIONS: Added latencies up to 250 ms were not associated with perceived latency, but latencies ≥400 ms were perceptible. Based on these findings, future telestenting studies should utilize networks with latencies ≤250 ms if perceived latency is to be avoided.


Assuntos
Redes de Comunicação de Computadores , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/instrumentação , Consulta Remota/instrumentação , Robótica/instrumentação , Stents , Terapia Assistida por Computador/instrumentação , Animais , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Manequins , Modelos Animais , Intervenção Coronária Percutânea/efeitos adversos , Sus scrofa , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS