Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transl Vis Sci Technol ; 10(12): 14, 2021 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-34636906

RESUMO

Purpose: Identifying the most sensitive functional measure in intermediate age-related macular degeneration (iAMD) could help select an appropriate test for monitoring disease progression and evaluating the efficacy of novel interventions for the early stages of AMD. The purpose of the study was to determine which commonly used visual function test is the most discriminatory when comparing individuals with iAMD to normal participants. Methods: In this prospective observational study, iAMD cases and healthy controls underwent visual function testing (best corrected visual acuity (BCVA), low luminance visual acuity (LLVA), mesopic microperimetry, dark adaptation, and scotopic perimetry following photobleach), clinical eye examination, and multimodal retinal imaging in a single study visit. The data of each functional parameter were converted into z-score so that all the parameters had a common scale to allow a direct comparison between different functional parameters. Results: Forty-eight subjects (23 normal control, 25 iAMD) participated. Although all five parameters showed a significant reduction in function in iAMD eyes compared to controls (P ≤ 0.003), the rod intercept time (RIT) detected the greatest reduction in function followed by the scotopic sensitivity, mesopic sensitivity, BCVA, and LLVA, with the absolute mean z-score of 4.5, 2.2, 1.0, 1.0, and 1.2, respectively. Conclusions: Among the five visual function parameters commonly used, RIT is the most discriminatory functional parameter in the early stages of AMD. Translational Relevance: The RIT could be considered for assessing visual function and evaluating efficacy of novel interventions aimed at improving retinal function in eyes with early stages of AMD.


Assuntos
Degeneração Macular , Estudos Transversais , Humanos , Degeneração Macular/diagnóstico , Retina/diagnóstico por imagem , Acuidade Visual , Testes de Campo Visual
2.
Invest Ophthalmol Vis Sci ; 60(5): 1511-1518, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30994862

RESUMO

Purpose: To evaluate rod function longitudinally in intermediate age-related macular degeneration subjects with reticular pseudodrusen (RPD) and without RPD (AMD). Methods: Retinal sensitivities (505 and 625 nm) during dark adaptation, at 14 locations within the central 12° macula were obtained after photobleaching at baseline and 12-month visits. Pointwise sensitivity differences between both stimuli were used to assess static rod function, while rod intercept time (RIT) and rod recovery rate (RRR) were used to evaluate dynamic function. Changes in function over time were compared between groups. Results: A total of 23 controls, 12 AMD, and 13 RPD cases were followed-up. At baseline, the RPD group had significantly worst static and dynamic rod function compared to AMD and control groups. Static function in AMD was similar to controls. Static and dynamic function across the central 12° was consistent in controls; however, it was most impaired at 4° compared to 12° eccentricity in disease groups. Over 12 months, no AMD cases progressed clinically and static function in AMD improved (P ≤ 0.04), but remained unchanged in control and RPD groups (P ≥ 0.17). The RRR for control and RPD groups remained stable, while the AMD group deteriorated, but only at 12° (P = 0.02). The RIT was stable in AMD (P = 0.75) and RPD (P = 0.71) groups but improved in the control group (P = 0.002). Conclusions: A decrease in RRR was detected over 12 months at 12° eccentricity in the AMD group. Evaluating changes in rod function requires testing at multiple locations including the peripheral macula.


Assuntos
Degeneração Macular/fisiopatologia , Drusas Retinianas/fisiopatologia , Células Fotorreceptoras Retinianas Bastonetes/fisiologia , Idoso , Idoso de 80 Anos ou mais , Adaptação à Escuridão/fisiologia , Feminino , Angiofluoresceinografia , Seguimentos , Humanos , Degeneração Macular/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Estimulação Luminosa , Estudos Prospectivos , Recuperação de Função Fisiológica/fisiologia , Drusas Retinianas/diagnóstico por imagem , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia , Testes de Campo Visual
3.
Transl Vis Sci Technol ; 7(3): 3, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29736324

RESUMO

PURPOSE: To determine the intrasession and intersession test-retest repeatability of retinal sensitivity measurements using a dark-adapted chromatic perimeter (DACP). METHODS: For intrasession testing, retinal sensitivity within the central 24° for the 505-nm stimulus was measured after 20, 30, and 40 minutes of dark adaptation (DA) and for the 625-nm stimulus was measured after the first and second 505-nm tests. For intersession testing, retinal sensitivity for both stimuli was measured after 30 minutes of DA at baseline and 1 month. The point-wise sensitivity (PWS) difference and coefficient of repeatability (CoR) of each stimulus and group were determined. RESULTS: For intrasession testing, 10 age-related macular degeneration (AMD) and eight control subjects were recruited. The overall CoR for the 505-nm stimulus was 8.4 dB for control subjects and 9.1 dB for AMD cases, and for the 625-nm stimulus was 6.7 dB for control subjects and 9.5 dB for AMD cases. For intersession testing, seven AMD cases and 13 control subjects returned an overall CoR for the 505-nm stimulus of 8.2 dB for the control and 11.7 dB for the AMD group. For the 625-nm stimulus the CoR was 6.2 dB for the control group and 8.4 dB for the AMD group. Approximately 80% of all test points had a PWS difference of ±5 dB between the two intrasession or intersession measurements for both stimuli. CONCLUSIONS: The CoR for the DACP is larger than that reported for scotopic perimeters; however, the majority of test points had a PWS difference of ±5 dB between tests. TRANSLATIONAL RELEVANCE: The DACP offers an opportunity to measure static and dynamic rod function at multiple locations with an acceptable reproducibility level.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...