1.
Phys Med ; 68: 47-51, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31739145

RESUMO

OBJECTIVE: This study measured the radiation exposure of the eye lens of medical personnel performing fluoroscopy and interventional procedures at the Sarawak General Hospital in Kuching, Sarawak, Malaysia. This study was the first in Malaysia to utilise in vivo radiation measurement relatively near the eye lens. METHODS: 41 medical personnel performing 79 procedures were monitored for their eye lens exposure using the NanoDot™ optically-stimulated luminescence dosimeters (OSLD) taped to the outer canthus of their eyes. The air-kerma area product (KAP), fluoroscopy time (FT) and number of procedure runs were also recorded. RESULTS: KAP, FT and number of runs were strongly correlated. However, only weak to moderate correlations were observed between these parameters with the measured eye lens doses. The average median equivalent eye lens dose was 0.052 mSv (ranging from 0.0155 to 0.672 mSv). The eye lens doses of primary operators were found to be significantly higher than their assistants due to the closer proximity to the patient and X-ray tube. The left eye lens of the operators received the highest amount of radiation due to their habitual positioning towards the radiation source. CONCLUSION: KAP and FT were not useful in predicting the equivalent eye lens dose exposure in interventional radiological procedures. Direct in vivo measurements were needed to provide a better estimate of the eye lens doses received by medical personnel during these procedures. This study highlights the importance of using direct measurement, such as OSLDs, instead of just indirect factors to monitor dose in the eye lens in radiological procedures.


Assuntos
Pessoal de Saúde , Hospitais , Cristalino/efeitos da radiação , Exposição Ocupacional/análise , Doses de Radiação , Radiologia Intervencionista , Fluoroscopia/efeitos adversos , Humanos , Malásia , Exposição Ocupacional/efeitos adversos
2.
Artif Intell Med ; 100: 101724, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31607348

RESUMO

Cardiovascular diseases are the primary cause of death globally. These are often associated with atherosclerosis. This inflammation process triggers important variations in the coronary arteries (CA) and can lead to coronary artery disease (CAD). The presence of CA calcification (CAC) has recently been shown to be a strong predictor of CAD. In this clinical setting, computed tomography angiography (CTA) has begun to play a crucial role as a non-intrusive imaging method to characterize and study CA plaques. Herein, we describe an automated algorithm to classify plaque as either normal, calcified, or non-calcified using 2646 CTA images acquired from 73 patients. The automated technique is based on various features that are extracted from the Gabor transform of the acquired CTA images. Specifically, seven features are extracted from the Gabor coefficients : energy, and Kapur, Max, Rényi, Shannon, Vajda, and Yager entropies. The features were then ordered based on the F-value and input to numerous classification methods to achieve the best classification accuracy with the least number of features. Moreover, two well-known feature reduction techniques were employed, and the features acquired were also ranked according to F-value and input to several classifiers. The best classification results were obtained using all computed features without the employment of feature reduction, using a probabilistic neural network. An accuracy, positive predictive value, sensitivity, and specificity of 89.09%, 91.70%, 91.83% and 83.70% was obtained, respectively. Based on these results, it is evident that the technique can be helpful in the automated classification of plaques present in CTA images, and may become an important tool to reduce procedural costs and patient radiation dose. This could also aid clinicians in plaque diagnostics.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/classificação , Aprendizado Profundo , Diagnóstico por Computador , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/classificação
3.
Quant Imaging Med Surg ; 9(4): 552-564, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31143647

RESUMO

BACKGROUND: High delivery rate is an important factor in optimizing contrast medium administration in coronary computed tomography angiography (CCTA). A personalized contrast volume calculation algorithm incorporating high iodine delivery rate (IDR) can reduce total iodine dose (TID) and produce optimal vessel contrast enhancement (VCE) in low tube voltage CCTA. In this study, we developed and validated an algorithm for calculating the volume of contrast medium delivered at a high rate for patients undergoing retrospectively ECG-gated CCTA with low tube voltage protocol. METHODS: The algorithm for an IDR of 2.22 gI·s-1 was developed based on the relationship between VCE and contrast volume in 141 patients; test bolus parameters and characteristics in 75 patients; and, tube voltage in a phantom study. The algorithm was retrospectively tested in 45 patients who underwent retrospectively ECG-gated CCTA with a 100 kVp protocol. Image quality, TID and radiation dose exposure were compared with those produced using the 120 kVp and routine contrast protocols. RESULTS: Age, sex, body surface area (BSA) and peak contrast enhancement (PCE) were significant predictors for VCE (P<0.05). A strong linear correlation was observed between VCE and contrast volume (r=0.97, P<0.05). The 100-to-120 kVp contrast enhancement conversion factor (Ec) was calculated at 0.81. Optimal VCE (250 to 450 HU) and diagnostic image quality were obtained with significant reductions in TID (32.1%) and radiation dose (38.5%) when using 100 kVp and personalized contrast volume calculation algorithm compared with 120 kVp and routine contrast protocols (P<0.05). CONCLUSIONS: The proposed algorithm could significantly reduce TID and radiation exposure while maintaining optimal VCE and image quality in CCTA with 100 kVp protocol.

4.
Br J Radiol ; 91(1088): 20170874, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29493261

RESUMO

OBJECTIVE: This study aimed (1) to perform a systematic review on scanning parameters and contrast medium (CM) reduction methods used in prospectively electrocardiography (ECG-triggered low tube voltage coronary CT angiography (CCTA), (2) to compare the achievable dose reduction and image quality and (3) to propose appropriate scanning techniques and CM administration methods. METHODS: A systematic search was performed in PubMed, the Cochrane library, CINAHL, Web of Science, ScienceDirect and Scopus, where 20 studies were selected for analysis of scanning parameters and CM reduction methods. RESULTS: The mean effective dose (HE) ranged from 0.31 to 2.75 mSv at 80 kVp, 0.69 to 6.29 mSv at 100 kVp and 1.53 to 10.7 mSv at 120 kVp. Radiation dose reductions of 38 to 83% at 80 kVp and 3 to 80% at 100 kVp could be achieved with preserved image quality. Similar vessel contrast enhancement to 120 kVp could be obtained by applying iodine delivery rate (IDR) of 1.35 to 1.45 g s-1 with total iodine dose (TID) of between 10.9 and 16.2 g at 80 kVp and IDR of 1.08 to 1.70 g s-1 with TID of between 18.9 and 20.9 g at 100 kVp. CONCLUSION: This systematic review found that radiation doses could be reduced to a rate of 38 to 83% at 80 kVp, and 3 to 80% at 100 kVp without compromising the image quality. Advances in knowledge: The suggested appropriate scanning parameters and CM reduction methods can be used to help users in achieving diagnostic image quality with reduced radiation dose.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Eletrocardiografia , Humanos , Doses de Radiação
5.
Phys Med ; 45: 198-204, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29373248

RESUMO

PURPOSE: Accurate determination of the bifurcation angle and correlation with plaque buildup may lead to the prediction of coronary artery disease (CAD). This work evaluates two techniques to measure bifurcation angles in 3D space using coronary computed tomography angiography (CCTA). MATERIALS AND METHODS: Nine phantoms were fabricated with different bifurcation angles ranging from 55.3° to 134.5°. General X-ray and CCTA were employed to acquire 2D and 3D images of the bifurcation phantoms, respectively. Multiplanar reformation (MPR) and volume rendering technique (VRT) were used to measure the bifurcation angle between the left anterior descending (LAD) and left circumflex arteries (LCx). The measured angles were compared with the true values to determine the accuracy of each measurement technique. Inter-observer variability was evaluated. The two techniques were further applied on 50 clinical CCTA cases to verify its clinical value. RESULTS: In the phantom setting, the mean absolute differences calculated between the true and measured angles by MPR and VRT were 2.4°±2.2° and 3.8°±2.9°, respectively. Strong correlation was found between the true and measured bifurcation angles. Furthermore, no significant differences were found between the bifurcation angles measured using either technique. In clinical settings, large difference of 12.0°±10.6° was found between the two techniques. CONCLUSION: In the phantom setting, both techniques demonstrated a significant correlation to the true bifurcation angle. Despite the lack of agreement of the two techniques in the clinical context, our findings in phantoms suggest that MPR should be preferred to VRT for the measurement of coronary bifurcation angle by CCTA.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Imageamento Tridimensional/métodos , Angiografia por Tomografia Computadorizada/instrumentação , Angiografia Coronária/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional/instrumentação , Masculino , Modelos Anatômicos , Variações Dependentes do Observador , Imagens de Fantasmas
6.
PLoS One ; 11(8): e0161543, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27552224

RESUMO

OBJECTIVES: This study aimed to measure the absorbed doses in selected organs for prospectively ECG-triggered coronary computed tomography angiography (CCTA) using five different generations CT scanners in a female adult anthropomorphic phantom and to estimate the effective dose (HE). MATERIALS AND METHODS: Prospectively ECG-triggered CCTA was performed using five commercially available CT scanners: 64-detector-row single source CT (SSCT), 2 × 32-detector-row-dual source CT (DSCT), 2 × 64-detector-row DSCT and 320-detector-row SSCT scanners. Absorbed doses were measured in 34 organs using pre-calibrated optically stimulated luminescence dosimeters (OSLDs) placed inside a standard female adult anthropomorphic phantom. HE was calculated from the measured organ doses and compared to the HE derived from the air kerma-length product (PKL) using the conversion coefficient of 0.014 mSv∙mGy-1∙cm-1 for the chest region. RESULTS: Both breasts and lungs received the highest radiation dose during CCTA examination. The highest HE was received from 2 × 32-detector-row DSCT scanner (6.06 ± 0.72 mSv), followed by 64-detector-row SSCT (5.60 ± 0.68 and 5.02 ± 0.73 mSv), 2 × 64-detector-row DSCT (1.88 ± 0.25 mSv) and 320-detector-row SSCT (1.34 ± 0.48 mSv) scanners. HE calculated from the measured organ doses were about 38 to 53% higher than the HE derived from the PKL-to-HE conversion factor. CONCLUSION: The radiation doses received from a prospectively ECG-triggered CCTA are relatively small and are depending on the scanner technology and imaging protocols. HE as low as 1.34 and 1.88 mSv can be achieved in prospectively ECG-triggered CCTA using 320-detector-row SSCT and 2 × 64-detector-row DSCT scanners.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doses de Radiação , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Feminino , Humanos , Especificidade de Órgãos/efeitos da radiação , Imagens de Fantasmas , Radiometria , Tomógrafos Computadorizados