Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Heart J Cardiovasc Imaging ; 20(12): 1395-1406, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31220240

RESUMO

AIMS: To investigate valve sizing and the haemodynamic relevance of the predicted left ventricular outflow tract (LVOT) in patients with mitral annular calcification (MAC) undergoing transatrial transcatheter valve implantation (THV). METHODS AND RESULTS: In total, 21 patients undergoing transatrial THV, multiplanar reconstruction (MPR), maximum intensity projection (MIP), and cubic spline interpolation (CSI) were compared for MA sizing during diastole. In addition, predicted neo-LVOT areas were measured in 18 patients and correlated with the post-procedural haemodynamic dimensions. The procedure was successful in all patients (100%). Concomitant aortic valve replacement was performed in eight patients (43%) (AVR group). Sizing using MPR and MIP yielded comparable results in terms of area, perimeter, and diameter, whereas the dimensions obtained with CSI were systematically smaller. The simulated mean systolic neo-LVOT area was 133.4 ± 64.2 mm2 with an anticipated relative LVOT area reduction (neo-LVOT area/LVOT area × 100) of 59.3 ± 14.7%. The systolic relative LVOT area reduction, but not the absolute neo-LVOT area, was found to predict the peak (r = 0.69; P = 0.002) and mean (r = 0.65; P = 0.004) post-operative aortic gradient in the overall population as well as separately in the AVR (peak: r = 0.91; P = 0.002/mean: r = 0.85; P = 0.002) and no-AVR (peak: r = 0.89; P = 0.003/mean: r = 0.72; P = 0.008) groups. CONCLUSION: In patients with severe MAC undergoing transatrial transcatheter valve implantation, MPR, and MIP yielded comparable annular dimensions, while values obtained with CSI tended to be systematically smaller. Mitral annular area and the average annular diameter appear to be reliable parameters for valve selection. Simulated relative LVOT reduction was found to predict the post-procedural aortic gradients.


Assuntos
Estenose da Valva Aórtica , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...