Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 294
Filtrar
1.
J Card Fail ; 30(10): 1302-1318, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39389742

RESUMO

Secondary mitral regurgitation (SMR) is associated with increased mortality and heart failure hospitalizations. The management of heart failure patients with SMR is complex and requires a multidisciplinary Heart Team approach. Guideline-directed medical therapies remain fundamental, yet in a proportion of patients SMR persists. In the past decade, transcatheter edge-to-edge repair (TEER) has been shown to improve survival in patients with SMR who remain symptomatic despite medical therapy. Technical advancements across newer generations of devices, improved imaging, and greater operator expertise have collectively contributed to the increased safety and efficacy of this procedure over time. Various emerging transcatheter mitral valve repair and replacement devices are currently under investigation and may offer superior, complementary or synergistic treatment options in patients ineligible for TEER. This review provides a state-of-the-art overview regarding the diagnosis of SMR, and currently available transcatheter mitral valve interventions and describes a contemporary approach to the management of SMR.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/terapia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Gerenciamento Clínico
2.
JACC Heart Fail ; 2024 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-39269396

RESUMO

BACKGROUND: Moderate secondary mitral regurgitation (SMR) represents a subgroup of heart failure (HF) patients with treatment restricted to medical therapy. Outcomes in patients with moderate SMR treated with mitral transcatheter edge-to-edge repair (M-TEER) are less well known. OBJECTIVES: The aim of this study was to assess the safety and effectiveness of M-TEER in subjects with moderate SMR using the EXPANDed studies. METHODS: One-year outcomes in subjects from the EXPANDed studies (EXPAND [A Contemporary, Prospective Study Evaluating Real-world Experience of Performance and Safety for the Next Generation of MitraClip Devices] and EXPAND G4 [A Post-Market Study Assessment of the Safety and Performance of the MitraClip G4 System] MitraClip studies) with baseline moderate SMR (2+), per echocardiographic core laboratory (ECL) assessment, were compared with subjects with baseline severe SMR (≥3+). RESULTS: There were 335 subjects with moderate SMR and 525 with severe SMR at baseline per ECL review. Baseline characteristics were similar between the 2 subgroups. After treatment with M-TEER, significant MR reduction was achieved in both groups. Significant left ventricular (LV) reverse remodeling was observed through 1 year, with a >20 mL decrease in LV end-diastolic and end-systolic volumes on average in the moderate SMR group. Significant 1-year improvements in NYHA functional class (>78% NYHA functional class I or II) and quality of life (>20 points on the Kansas City Cardiomyopathy Questionnaire-Overall Summary) were observed in subjects with moderate SMR. Similarly, low rates of major adverse events, all-cause mortality, and HF hospitalizations were observed between the 2 subgroups through 1 year. CONCLUSIONS: In the EXPANDed studies, subjects with moderate SMR treated with M-TEER had improvements similar to subjects with severe SMR in quality of life and positive LV remodeling at 1 year. Future studies are needed to evaluate if M-TEER would be beneficial for HF patients with moderate SMR.

3.
JACC Cardiovasc Interv ; 17(18): 2141-2153, 2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39243262

RESUMO

BACKGROUND: Patients with mitral regurgitation (MR) and morphologic presence of relevant mitral annular calcification (MAC) represent a challenging phenotypic subset with limited treatment options. OBJECTIVES: The aim of this study was to assess the feasibility of transcatheter mitral valve replacement (TMVR) using dedicated devices for the treatment of MAC patients. METHODS: Consecutive patients with symptomatic MR receiving TMVR and with available computed tomography data from the CHOICE-MI (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency) multicenter registry were stratified by the presence of none or mild mitral annular calcification (MACnone/mild) vs moderate or severe mitral annular calcification (MACmod/sev). RESULTS: Among 279 eligible patients (median age = 76.0 years [Q1-Q3: 71.0-81.0 years], EuroSCORE II = 6.2% [Q1-Q3: 3.9%-12.1%]), 222 (79.6%) presented with MACnone/mild and 57 (20.4%) with MACmod/sev. Patients with MACmod/sev had a higher prevalence of extracardiac arteriopathy (P = 0.011) and primary MR (P < 0.001). Although the technical success rate and the extent of MR elimination did not differ, TMVR treatment in MACmod/sev patients was associated with higher rates of postprocedural bleeding complications (P = 0.02) and renal failure (P < 0.001). Functional improvement at the 1- and 2-year follow-up did not differ between groups. At the 2-year follow-up, there were no differences between patients with MACmod/sev and MACnone/mild regarding all-cause mortality (38.5% vs 37.7%; P = 0.76), cardiovascular mortality (21.3% vs 24.9%; P = 0.97), and all-cause mortality or heart failure hospitalization (52.4% vs 46.7%; P = 0.28) CONCLUSIONS: TMVR in patients with MACmod/sev is associated with higher rates of postprocedural complications but similar rates of survival, MR resolution, and functional improvement compared to MACnone/mild. Further studies are necessary to define the role of dedicated TMVR devices in this population. (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency Registry [CHOICE-MI]; NCT04688190).


Assuntos
Calcinose , Cateterismo Cardíaco , Estudos de Viabilidade , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Mitral , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Humanos , Idoso , Masculino , Feminino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Idoso de 80 Anos ou mais , Fatores de Tempo , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Calcinose/mortalidade , Calcinose/fisiopatologia , Calcinose/terapia , Fatores de Risco , Índice de Gravidade de Doença , Europa (Continente)
4.
JACC Cardiovasc Interv ; 17(18): 2113-2122, 2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39243264

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is a common valve disease that has a significant impact on patients' quality of life. OBJECTIVES: This study sought to report the final 3-year outcomes of tricuspid transcatheter edge-to-edge repair (T-TEER) with the TriClip (Abbott) implant from the TRILUMINATE (TRILUMINATE Study With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater TR) study for the treatment of severe symptomatic TR. METHODS: The TRILUMINATE study (N = 98 subjects) is an international, prospective, single-arm, multicenter study to investigate the safety and performance of T-TEER with the TriClip implant in patients with symptomatic moderate or greater TR. Echocardiographic assessments were performed at a core laboratory. RESULTS: At 3 years, TR was reduced to moderate or less in 79% of subjects, and a reduction of at least 1 grade was achieved in 92% of subjects. TR reduction achieved at 1 year was sustained through 3 years. Subjects also experienced an improvement in heart failure symptoms assessed by NYHA functional class and quality of life assessed by the Kansas City Cardiomyopathy Questionnaire at 3 years compared to baseline. The site-reported heart failure hospitalization rate decreased from 0.56 events/patient-year 1 year before device implantation to 0.14 events/patient-year 3 years after device implantation, representing a reduction of 75% (P < 0.0001). CONCLUSIONS: In the longest follow-up to date of any T-TEER therapy, the TRILUMINATE study demonstrated that the TriClip procedure is both safe and effective, with sustained benefits at 3 years in subjects with symptomatic moderate or greater TR. (TRILUMINATE Study With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater TR [TRILUMINATE]; NCT03227757).


Assuntos
Cateterismo Cardíaco , Qualidade de Vida , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Feminino , Estudos Prospectivos , Resultado do Tratamento , Masculino , Idoso , Fatores de Tempo , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Pessoa de Meia-Idade , Valva Tricúspide/cirurgia , Valva Tricúspide/fisiopatologia , Valva Tricúspide/diagnóstico por imagem , Desenho de Prótese , Idoso de 80 Anos ou mais , Estados Unidos , Europa (Continente) , Estado Funcional
6.
JACC Cardiovasc Interv ; 17(18): 2170-2179, 2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39322365

RESUMO

BACKGROUND: Transcatheter tricuspid valve intervention (TTVI) has been increasingly adopted in recent years for the treatment of patients with tricuspid regurgitation (TR). However, no dedicated risk stratification has been established for patients undergoing TTVI. OBJECTIVES: The aim of the present study was to propose a dedicated risk score for patients affected by severe TR undergoing TTVI. METHODS: The score was derived from the TRIVALVE (International Multisite Transcatheter Tricuspid Valve Therapies Registry; NCT03416166) registry, according to data availability. A stepwise model approach was used on predictor variables to develop a scoring system for predicting 12-month mortality or rehospitalization using multivariable logistic regression. Internal discrimination, calibration, and validation were assessed using receiver-operating characteristic curve analysis and bootstrapping with 1,000 resamples. RESULTS: A total of 483 patients were included in the study, with an overall 12-month mortality or rehospitalization rate of 19% (n = 94). The final risk score, ranging from 0 to 4.5, included the following 5 parameters (adjusted for age and gender): 1) atrial fibrillation at baseline; 2) glomerular filtration rate <30 mL/min; 3) elevated gamma-glutamyl transferase/bilirubin levels; 4) signs of right heart failure; and 5) left ventricular ejection fraction <50%. The bias-corrected area under the receiver-operating characteristic curve was 68% (95% CI: 62%-75%). A cutoff value of 2.5 demonstrated sensitivity of 65.4% and specificity of 60.5% for the outcome. CONCLUSIONS: The present study proposes a dedicated risk score for patients undergoing TTVI, providing an additional and simple tool for heart teams to select the best therapy for patients affected by severe TR.


Assuntos
Cateterismo Cardíaco , Técnicas de Apoio para a Decisão , Implante de Prótese de Valva Cardíaca , Readmissão do Paciente , Valor Preditivo dos Testes , Sistema de Registros , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Medição de Risco , Masculino , Feminino , Fatores de Risco , Idoso , Valva Tricúspide/fisiopatologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/instrumentação , Fatores de Tempo , Idoso de 80 Anos ou mais , Resultado do Tratamento , Reprodutibilidade dos Testes , Tomada de Decisão Clínica , Pessoa de Meia-Idade
7.
Artigo em Inglês | MEDLINE | ID: mdl-39189600

RESUMO

AIMS: Transcatheter tricuspid valve interventions (TTVI) are increasingly used to treat patients with significant tricuspid regurgitation (TR). The evolution of concurrent mitral regurgitation (MR) severity after TTVI is currently unknown and may be pivotal for clinical decision-making. The aim of this study was to assess the evolution of MR after TTVI and to identify predictors of MR worsening and improvement. METHODS AND RESULTS: This analysis is a substudy of the Trivalve Registry, an international registry designed to collect data on TTVI. This substudy included all patients with echocardiographic data on MR evolution and excluded those with a concomitant tricuspid and mitral transcatheter valve intervention or with a history of mitral valve intervention. The co-primary outcomes were MR improvement and worsening at two timepoints: pre-discharge and 2-month follow-up. This analysis included 359 patients with severe TR, mostly(80%) treated with tricuspid transcatheter edge-to-edge repair(T-TEER). MR improvement was found in 106(29.5%) and 99(34%) patients, while MR worsening in 34(9.5%) and 33(11%) patients at pre-discharge and 2-month follow-up, respectively. Annuloplasty and heterotopic replacement were associated with MR worsening. Independent predictors of MR improvement were: atrial fibrillation, T-TEER, acute procedural success, TR reduction, LVEDD>60 mm and beta-blocker therapy. Patients with moderate-to-severe/severe MR following TTVI showed significantly higher death rates. CONCLUSION: MR degree variation is common after TTVI, with most cases showing improvement. Clinical and procedural characteristics may predict the MR evolution, in particular procedural success and T-TEER play key roles in MR outcomes. TTVI may be beneficial even in the presence of functional MR.

11.
J Soc Cardiovasc Angiogr Interv ; 3(5): 101345, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-39132458

RESUMO

Background: Transcatheter edge-to-edge repair (TEER) improved outcomes in patients with heart failure (HF) and severe secondary mitral regurgitation (SMR) compared with guideline-directed medical therapy (GDMT) alone regardless of the severity of baseline left ventricular ejection fraction (LVEF). The study aimed to evaluate the effect of early changes in LVEF after TEER and GDMT alone in patients with HF and severe SMR. Methods: Within the COAPT trial, we evaluated outcomes according to changes in LVEF from baseline to 30 days. The primary outcome was all-cause death or HF hospitalization (HFH) between 30 days and 2 years. Results: Among 432 patients with paired echocardiographic data, 182 (42.1%) had increased LVEF (LVEF change 6.0% ± 4.9%) and 250 (57.9%) had a decrease or no change in LVEF (LVEF change -6.6% ± 5.6%) from baseline to 30 days. LVEF at 30 days increased more frequently with GDMT alone compared with TEER plus GDMT (51.4% vs 33.0%; P = .0001). Between 30 days and 2 years, there were no significant differences in death or HFH in the increase LVEF and the decrease LVEF groups (58.8% vs 51.4%; multivariable-adjusted HR, 0.97; 95% CI, 0.87-1.08; P = .59). TEER plus GDMT reduced the 30-day to 2-year rate of death or HFH compared with GDMT alone consistently in patients with increase LVEF and decrease LVEF (Pint = 0.75). Conclusions: Among patients with HF and severe SMR, early improvements in LVEF were more frequent with GDMT alone compared with TEER plus GDMT but were not associated with subsequent outcomes at 2 years. TEER reduced death or HFH during 2-year follow-up irrespective of early LVEF changes.

12.
J Soc Cardiovasc Angiogr Interv ; 3(5): 101349, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-39132457

RESUMO

Contrast-induced encephalopathy (CIE) is an idiopathic reaction following iodine-contrast dye administration in patients undergoing angiographic procedures. While it has been well-documented following coronary and carotid interventions, literature on CIE following transcatheter aortic valve replacement is limited. We report the multidisciplinary management of 3 patients with CIE following transcatheter aortic valve replacement.

13.
JACC Case Rep ; 29(15): 102458, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39157552
14.
JACC Cardiovasc Interv ; 17(14): 1631-1651, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39048251

RESUMO

Transcatheter aortic valve replacement (TAVR) has become more common than surgical aortic valve replacement since 2016, with over 200,000 procedures globally each year. As patients increasingly outlive their TAVR devices, managing these cases is a growing concern. Treatment options include surgical removal of the old TAVR device (transcatheter aortic valve [TAV] explant) or implantation of a new transcatheter aortic valve (redo TAV). Redo TAV is complex because of the unique designs of TAV devices; compatibility issues; and the need for individualized planning based on factors such as implant depth, shape, and coronary artery relationships. This review serves as a comprehensive guide for redo TAV, detailing the design characteristics of TAV devices, device compatibility, standardized terminology, and a structured approach for computed tomography analysis. It aims to facilitate decision making, risk identification, and achieving optimal outcomes in redo TAV procedures.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Reoperação , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Resultado do Tratamento , Fatores de Risco , Tomada de Decisão Clínica , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Terminologia como Assunto , Valor Preditivo dos Testes
15.
Artigo em Inglês | MEDLINE | ID: mdl-38970594

RESUMO

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

17.
JACC Cardiovasc Interv ; 17(11): 1340-1351, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38866457

RESUMO

BACKGROUND: The etiology of transcatheter aortic valve (TAV) degeneration is poorly understood, particularly noncalcific mechanisms. OBJECTIVES: The authors sought to investigate noncalcific and calcific mechanisms of TAV degeneration and evaluate their impact on leaflet function by bench testing, imaging, and histology. METHODS: TAV explants were obtained from the EXPLANT THV registry and clinical institutions. Hydrodynamic assessment was performed using a heart valve pulse duplicator system under physiological conditions. Micro-computed tomography, high-resolution photography, high speed video, and hematoxylin and eosin staining were used to evaluate the morphological appearance, leaflet kinematics, and calcium burden of TAVs. RESULTS: A total of 14 explants were evaluated: 10 self-expanding CoreValve/Evolut TAVs (Medtronic), 3 balloon-expandable SAPIEN 3 TAVs (Edwards Lifesciences), and 1 mechanically expandable Lotus TAV (Boston Scientific). The median patient age at explantation was 73.0 years (Q1-Q3: 64.5-80.0 years), with a time to explantation of 4 years 1 month (1 year 5 months to 4 years 11 months). Six TAV explants were found to have leaflet calcification (162.4 mm3; 58.8-603.0 mm3), and 8 had no calcification detectable by micro-computed tomography and histology. All samples had impaired leaflet kinematics. There was no significant difference in the hydrodynamic mean gradient between calcified (47.2 mm Hg; 26.6-74.1 mm Hg) and noncalcified (27.6 mm Hg; 15.2-36.7 mm Hg; P = 0.28) TAVs. Leaflet calcification had a weak but nonsignificant association with the hydrodynamic mean gradient (r = 0.42; P = 0.14). CONCLUSIONS: TAV function can be severely impacted by noncalcific and calcific mechanisms of tissue degeneration. Importantly, functional stenosis can occur in TAVs in the absence of obvious and significant calcification.


Assuntos
Valva Aórtica , Calcinose , Próteses Valvulares Cardíacas , Hidrodinâmica , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Microtomografia por Raio-X , Humanos , Idoso , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Calcinose/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Calcinose/cirurgia , Feminino , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Pessoa de Meia-Idade , Fatores de Tempo , Remoção de Dispositivo , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Fenômenos Biomecânicos , Teste de Materiais , Gravação em Vídeo
18.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Assuntos
Endocardite , Falha de Prótese , Infecções Relacionadas à Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/mortalidade , Endocardite/cirurgia , Endocardite/mortalidade , Remoção de Dispositivo , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
19.
JACC Cardiovasc Interv ; 17(12): 1485-1495, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38752971

RESUMO

BACKGROUND: The safety profile of transcatheter tricuspid valve (TTV) repair techniques is well established, but residual tricuspid regurgitation (TR) remains a concern. OBJECTIVES: The authors sought to assess the impact of residual TR severity post-TTV repair on survival. METHODS: We evaluated the survival rate at 2 years of 613 patients with severe isolated functional TR who underwent TTV repair in TRIGISTRY according to the severity of residual TR at discharge using a 3-grade (mild, moderate, and severe) or 4-grade scheme (mild, mild to moderate, moderate to severe, and severe). RESULTS: Residual TR was none/mild in 33%, moderate in 52%, and severe in 15%. The 2-year adjusted survival rates significantly differed between the 3 groups (85%, 70%, and 44%, respectively; restricted mean survival time [RMST]: P = 0.0001). When the 319 patients with moderate residual TR were subdivided into mild to moderate (n = 201, 33%) and moderate to severe (n = 118, 19%), the adjusted survival rate was also significantly different between groups (85%, 80%, 55%, and 44%, respectively; RMST: P = 0.001). Survival was significantly lower in patients with moderate to severe residual TR compared to patients with mild to moderate residual TR (P = 0.006). No difference in survival rates was observed between patients with no/mild and mild to moderate residual TR (P = 0.67) or between patients with moderate to severe and severe residual TR (P = 0.96). CONCLUSIONS: The moderate residual TR group was heterogeneous and encompassed patients with markedly different clinical outcomes. Refining TR grade classification with a more granular 4-grade scheme improved outcome prediction. Our results highlight the importance of achieving a mild to moderate or lower residual TR grade during TTV repair, which could define a successful intervention.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/mortalidade , Masculino , Feminino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Valva Tricúspide/fisiopatologia , Idoso , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Cardíaco/instrumentação , Fatores de Tempo , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Fatores de Risco , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Medição de Risco , Sistema de Registros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA