Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Zhongguo Zhen Jiu ; 43(6): 622-6, 2023 Jun 12.
Artigo em Chinês | MEDLINE | ID: mdl-37313554

RESUMO

OBJECTIVE: To compare the clinical efficacy of acupuncture with different frequencies in the treatment of patients with functional dyspepsia (FD). METHODS: A total of 90 patients with FD were randomly divided into a 3-time acupuncture treatment per week group (3-A group, 31 cases, 2 cases dropped off), a 1-time acupuncture treatment per week group (1-A group, 30 cases, 2 cases dropped off) and a control group (29 cases, 2 cases dropped off). In the two acupuncture groups, the acupoints were Zhongwan (CV 12) and bilateral Tianshu (ST 25), Neiguan (PC 6), Liangqiu (ST 34), Yanglingquan (GB 34), Zusanli (ST 36) and Taichong (LR 3), stimulated 3 times a week and once a week, respectively; and the treatment was given consecutively for 4 weeks. In the control group, no intervention was adopted, but the compensatory therapy was provided after the end of follow-up. The scores of the symptom index of dyspepsia (SID), self-rating anxiety scale (SAS) and self-rating depression scale (SDS) were compared among the 3 groups before treatment, after 4 weeks of treatment and in 4 and 8 weeks after treatment completion separately. The score of Nepean dyspepsia life quality index (NDLQI) was evaluated before treatment, after 2 and 4 weeks of treatment and in 4 and 8 weeks after treatment completion. RESULTS: After 4 weeks of treatment and in 4 and 8 weeks after treatment completion, the scores of SID, SAS and SDS were all reduced in the 3-A group and the 1-A group when compared with the scores before treatment (P<0.000 1, P<0.05). After 4 weeks of treatment, the scores of SID, SAS and SDS in the two acupuncture groups were lower than those in the control group (P<0.000 1). After 2 and 4 weeks of treatment, the increased values of NDLQI score in the two acupuncture groups were all higher than those in the control group (P<0.05). In 4 and 8 weeks after treatment completion, the scores of SID, SAS and SDS in the 3-A group were lower than those in the 1-A group (P<0.001, P<0.05), and the increased values of NDLQI score in the 3-A group were higher than those in the 1-A group (P<0.000 1). CONCLUSION: Acupuncture given 3 times per week is superior to the treatment given once per week in the aspects of relieving the clinical symptoms, improving the quality of life and regulating the emotional state in patients with FD. This efficacy is persistent for 8 weeks after treatment completion.


Assuntos
Terapia por Acupuntura , Dispepsia , Humanos , Dispepsia/terapia , Qualidade de Vida , Pontos de Acupuntura , Emoções
2.
Micromachines (Basel) ; 13(12)2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36557556

RESUMO

In this paper, we use terahertz combined with metamaterial technology as a powerful tool to identify analytes at different concentrations. Combined with the microfluidic chip, the experimental measurement can be performed with a small amount of analyte. In detecting the troponin antigen, surface modification is carried out by biochemical binding. Through the observation of fluorescent antibodies, the average number of fluorescent dots per unit of cruciform metamaterial is 25.60, and then, by adjusting the binding temperature and soaking time, the average number of fluorescent dots per unit of cruciform metamaterial can be increased to 181.02. Through the observation of fluorescent antibodies, it is confirmed that the antibodies can be successfully stabilized on the metamaterial and then bound to the target antigen. The minimum detectable concentration is between 0.05~0.1 µg/100 µL, and the concentration and ΔY show a positive correlation of R2 = 0.9909.

3.
Micromachines (Basel) ; 13(6)2022 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-35744518

RESUMO

Terahertz (THz) radiation has attracted wide attention in recent years due to its non-destructive properties and ability to sense molecular structures. In applications combining terahertz radiation with metamaterial technology, the interaction between the terahertz radiation and the metamaterials causes resonance reactions; different analytes have different resonance performances in the frequency domain. In addition, a microfluidic system is able to provide low volume reagents for detection, reduce noise from the environment, and concentrate the sample on the detection area. Through simulation, a cruciform metamaterial pattern was designed; the proportion, periodicity, and width of the metamaterial were adjusted to improve the sensing capability of the chip. In the experiments, the sensing capabilities of Type A, B, and C chips were compared. The Type C chip had the most significant resonant effect; its maximum shift could be increased to 89 GHz. In the probiotic experiment, the cruciform chip could have a 0.72 GHz shift at a concentration of 0.025 mg/50 µL, confirming that terahertz radiation combined with a metamaterial microfluidic chip can perform low-concentration detection.

4.
Micromachines (Basel) ; 11(1)2020 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-31936637

RESUMO

Terahertz (THz) radiation has attracted wide attention for its ability to sense molecular structure and chemical matter because of a label-free molecular fingerprint and nondestructive properties. When it comes to molecular recognition with terahertz radiation, our attention goes first towards the absorption spectrum, which is beyond the far infrared region. To enhance the sensitivity for similar species, however, it is necessary to apply an artificially designed metamaterial sensor for detection, which confines an electromagnetic field in an extremely sub-wavelength space and hence receives an electromagnetic response through resonance. Once the resonance is caused through the interaction between the THz radiation and the metamaterial, a minute variation might be observed in the frequency domain. For a geometric structure of a metamaterial, a novel design called an X-shaped plasmonic sensor (XPS) can create a quadrupole resonance and lead to sensitivity greater than in the dipole mode. A microfluidic system is able to consume reagents in small volumes for detection, to diminish noise from the environment, and to concentrate the sample into detection spots. A microfluidic device integrated with an X-shaped plasmonic sensor might thus achieve an effective and highly sensitive detection cartridge. Our tests involved not only measurements of liquid samples, but also the performance of a dry bio-sample coated on an XPS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...