Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Total Environ ; 784: 147156, 2021 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-34088053

RESUMO

While the equilibrium partitioning (EqP) method has been demonstrated to effectively predict the adverse effects of nonionic organic chemicals in sediment on benthic organisms by sediment toxicity tests, only a limited number of studies have been performed both in water-only and whole-sediment toxicity tests using the same species and verified the validity of EqP-based toxicity assessment. To further examine the validity of the EqP method for application in a wide range of hydrophobicity, we conducted sorption/desorption experiments and both water-only and sediment toxicity tests using a popular aquatic crustacean species, Daphnia magna (48 h), and benthic species Hyalella azteca (96 h) for six typical polycyclic aromatic hydrocarbons (PAHs) with three to five rings and an amine derivative: anthracene, phenanthrene, fluoranthene, pyrene, benzo[a]pyrene, dibenzo[a,h]anthracene, and 1-aminopyrene. The linear sorption coefficient was determined and ranged from 2.7 × 102 (phenanthrene) and 1.2 × 104 L/kg (benzo[a]pyrene) highly depending on the hydrophobicity while the aqueous concentrations were stable after 24 h in the desorption test. As result of acute toxicity tests in the water-only exposure system, anthracene and dibenz[a,h]anthracene were found to be nontoxic to both species, while median effect/lethal concentrations (EC50/LC50) were determined as ranging from 0.66 (benzo[a]pyrene) to 330 µg/L (phenanthrene), and from 11 (1-aminopyrene) to 180 µg/L (phenanthrene) for D. magna and H. azteca, respectively. Among these compounds, three PAHs with three, four, and five rings each, and 1-aminopyrene were subjected to sediment-water toxicity tests. In the sediment-water tests, the LC50 of phenanthrene and pyrene was three to six times higher than that of the water-only tests for H. azteca while the EC50 was 1.1 to 2.0 times higher for D. magna. In contrast, the EC50/LC50 of benzo[a]pyrene (BaP) in the sediment-water toxicity test was more than 5 times higher than that in the water-only test for both H. azteca and D. magna. The EC50/LC50 values of 1-aminopyrene were similar in both the sediment-water and the water-only toxicity tests, ranging narrowly from 21 to 28 µg/L and 8.8 to 11 µg/L for D. magna and H. azteca, respectively. The EC50/LC50 based on the body residue (ER50/LR50) was investigated for two of the representative PAHs, pyrene, and BaP. The ER50/LR50 of pyrene in both species was 2.3 and 11 times higher in the water-only toxicity test for D. magna and H. azteca, respectively, while those of BaP in the sediment-water toxicity test were not calculated for the sediment-water toxicity tests, and the highest body concentration in the sediment-water tests was lower than the ER50/LR50 in the water-only toxicity test. Although the experimental results were comparable with the predicted sediment toxicity values based on the EqP method for the selected PAHs in this study, there is a risk of phenanthrene and pyrene being slightly underestimated (1.4-1.9 fold for phenanthrene and 3.7-6.1 fold for pyrene) by the EqP method for H. azteca. These results reaffirm that the bioavailability of poorly water-soluble chemicals is important for sediment toxicity and that the exposure pathway should be further investigated to avoid under- and overestimation via the EqP method.


Assuntos
Hidrocarbonetos Policíclicos Aromáticos , Poluentes Químicos da Água , Animais , Daphnia , Sedimentos Geológicos , Hidrocarbonetos Policíclicos Aromáticos/toxicidade , Água , Poluentes Químicos da Água/toxicidade
2.
PLoS One ; 16(2): e0247426, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33606832

RESUMO

Aquatic organisms have been used to investigate the safety of chemicals worldwide. One such assessment is an algal growth inhibition test. Algal growth inhibition tests are commonly performed using a growth chamber with fluorescent lamps as the lighting source, as test guidelines require continuous uniform fluorescent illumination. However, fluorescent lamps contain mercury, which has been identified as hazardous to humans and other organisms. The Minamata Convention (adopted in 2013) requires reduction or prohibition of products containing mercury. On the other hand, light-emitting diodes do not contain mercury and provide a photosynthetically effective wavelength range of 400-700 nm which is an adequate light intensity for algal growth. Light-emitting diodes are thus preferable to fluorescent lamps as a potential light source in algal growth inhibition tests. In this study, we investigated if light-emitting diodes could be substituted for fluorescent lamps in growth inhibition studies with green alga (Pseudokirchneriella subcapitata), diatom (Navicula pelliculosa), and cyanobacteria (Anabaena flos-aquae). Algal growth inhibition tests were performed using five different chemicals known to have different modes of action and are assigned as reference substances in the test guidelines. The results of each algal test showed similar values between light-emitting diodes and fluorescent lamps in terms of conditions for the growth inhibition rate and percent inhibition in yield of each chemical. It was therefore concluded that using light-emitting diodes instead of fluorescent lamps as a lighting source had no effect on the algal growth inhibition test results.


Assuntos
Clorófitas/crescimento & desenvolvimento , Cianobactérias/crescimento & desenvolvimento , Diatomáceas/crescimento & desenvolvimento , Luz/efeitos adversos , Cloreto de Cádmio/farmacologia , Clorofenóis/farmacologia , Fluorescência , Técnicas Microbiológicas , Pressão Osmótica/efeitos dos fármacos , Fosforilação Oxidativa/efeitos dos fármacos , Pentaclorofenol/farmacologia , Fotossíntese/efeitos dos fármacos , Dicromato de Potássio/farmacologia , Cloreto de Sódio/farmacologia
3.
Sci Rep ; 10(1): 21490, 2020 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-33293611

RESUMO

Aquatic heavy metal pollution is a growing concern. To facilitate heavy metal monitoring in water, we developed transgenic Daphnia that are highly sensitive to heavy metals and respond to them rapidly. Metallothionein A, which was a metal response gene, and its promoter region was obtained from Daphnia magna. A chimeric gene fusing the promoter region with a green fluorescent protein (GFP) gene was integrated into D. magna using the TALEN technique and transgenic Daphnia named D. magna MetalloG were produced. When D. magna MetalloG was exposed to heavy metal solutions for 1 h, GFP expression was induced only in their midgut and hepatopancreas. The lowest concentrations of heavy metals that activated GFP expression were 1.2 µM Zn2+, 130 nM Cu2+, and 70 nM Cd2+. Heavy metal exposure for 24 h could lower the thresholds even further. D. magna MetalloG facilitates aqueous heavy metal detection and might enhance water quality monitoring.


Assuntos
Daphnia/genética , Monitoramento Ambiental/métodos , Poluentes Químicos da Água/análise , Animais , Animais Geneticamente Modificados/genética , Animais Geneticamente Modificados/metabolismo , Fluorescência , Engenharia Genética/métodos , Metalotioneína/metabolismo , Metais Pesados/toxicidade , Água/análise , Água/química , Poluentes Químicos da Água/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...