Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Immunol ; 15: 1402523, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38863715

RESUMO

We described a challenging case of anti-N-methyl-D-aspartate receptor (NMDAR) encephalitis in a young girl. Despite enduring months of reduced consciousness with ongoing antibody presence, she ultimately exhibited remarkable improvement within a 5-year follow-up period. Additionally, we conducted a concise review of relevant literature on anti-NMDAR encephalitis, with a specific focus on anti-NMDAR antibodies. Our findings enhance the clinical comprehension of anti-NMDAR encephalitis and offer valuable insights to clinicians for its management.


Assuntos
Encefalite Antirreceptor de N-Metil-D-Aspartato , Autoanticorpos , Humanos , Encefalite Antirreceptor de N-Metil-D-Aspartato/imunologia , Encefalite Antirreceptor de N-Metil-D-Aspartato/diagnóstico , Encefalite Antirreceptor de N-Metil-D-Aspartato/complicações , Feminino , Autoanticorpos/imunologia , Autoanticorpos/sangue , Receptores de N-Metil-D-Aspartato/imunologia , Criança , Transtornos da Consciência/etiologia , Transtornos da Consciência/imunologia
2.
Langmuir ; 39(39): 14173-14188, 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37734066

RESUMO

Green biosurfactants are emerging as a promising area of research. However, there is a limited focus on the adsorption and wetting characteristics of biosurfactants on coal dust. This study explores the effects of sophorolipid (SL) biosurfactants on the microstructure and wettability of different coalification degree coal. The microstructure parameters of SL adsorbed on coal dust were measured using a surface tensiometer, contact angle analyzer, and particle size analyzer. The results indicate that SL has the lowest critical surface tension, leading to a 9.25° decrease in the contact angle for low-rank bituminous coal (YZ-LRBC). Furthermore, SL significantly altered the particle size distribution of lignite (NM-LC) and YZ-LRBC. The pore size structure of SL-infiltrated coal dust was quantified using a specific surface area analyzer, revealing a decrease in the specific surface area and an increase in the average pore size. The infrared analysis demonstrated that SL permeation significantly increased the percentage of hydrophilic functional groups (hydroxyl structures) while reducing the hydrophobic functional groups (aliphatic hydrocarbon and aromatic structure). Based on the measured microstructure parameters, a regression equation for contact angle was established: [contact angle (°)] = 73.800 - 0.860 × [D10 (nm)] + 4.280 × [specific surface area (m2/g)]. Notably, the characteristic particle size D10 had a significant negative effect on the contact angle, while the specific surface area had a significant positive effect. These findings provide a theoretical foundation for the application of biosurfactants in water injection to reduce dust and improve the wetting efficiency.

3.
Materials (Basel) ; 15(2)2022 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-35057283

RESUMO

An experimental study on the flow rate and atomization characteristics of a new gas-liquid two-phase flow nozzle was carried out to use high-concentration respirable dust in the workplace of high-efficiency sedimentation coal production based on the gas-liquid two-phase flow nozzle technology. The simulation roadway of dust fall in large coal mines was constructed, and the respirable rock dust produced by fully mechanized mining surfaces was chosen as the research object. The effects of humidity on the capture effect of respirable rock dust were analyzed in the experimental study. The results demonstrated that: (1) the distribution range of the particle size of fogdrops declines with the reduction in fogdrops D50, D[3,2] and D[4,3], which are produced by gas-liquid two-phase flow nozzles. (2) The initial ambient humidity in the simulated roadway was 64.8% RH. After the gas-liquid two-phase flow spray was started, the ambient humidity was elevated by 23.2 to 23.5% RH within 840s and tended to be stable and no longer grew after reaching 88.0-88.3% RH. The initial growth rate of the ambient humidity in the simulated roadway was high, and then was gradually slowed down. (3) Humidity is an important factor influencing the collection of respirable dust. The humidity at 10.0 m leeward of the dust-producing point was increased by 19.6% RH, and the sedimentation rate of respirable dust was increased by 6.73%; the two growth rates were 13.1% RH and 9.90% at 20.0 m; 16.4% RH and 15.42% at 30.0 m; 18.4% RH and 11.20% at 40.0 m. In practical applications of the gas-liquid two-phase flow nozzle in coal mining activities, attention shall be paid to not only the influences of its atomization characteristics on the capture effect of respirable dust but also the influences of the flow rate of the nozzle on the humidity of the working surface. Appropriate gas and water supply pressures shall be chosen according to the space and respirable dust concentration on the working surface to realize a better dust removal effect.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...