Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
J Am Chem Soc ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38728652

RESUMO

Porous organic polymers (POPs) with inherent porosity, tunable pore environment, and semiconductive property are ideally suitable for application in various advanced semiconductor-related devices. However, owing to the lack of processability, POPs are usually prepared in powder forms, which limits their application in advanced devices. Herein, we demonstrate an example of information storage application of POPs with film form prepared by an electrochemical method. The growth process of the electropolymerized films in accordance with the Volmer-Weber model was proposed by observation of atomic force microscopy. Given the mechanism of the electron transfer system, we verified and mainly emphasized the importance of porosity and interfacial properties of porous polymer films for memristor. As expected, the as-fabricated memristors exhibit good performance on low turn-on voltage (0.65 ± 0.10 V), reliable data storage, and high on/off current ratio (104). This work offers inspiration for applying POPs in the form of electropolymerized films in various advanced semiconductor-related devices.

2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-997059

RESUMO

@#Objective     To systematically evaluate the safety and efficacy of percutaneous closure of atrial septal defect (ASD) guided by echocardiography alone versus fluoroscopy. Methods     The databases of PubMed, The Cochrane Library, EMbase, VIP, Wanfang Data and CNKI from January 2000 to October 2021 were searched by computer for relevant research literature. Two reviewers independently screened the literature, extracted the data and evaluated the quality according to the inclusion and exclusion criteria. Meta-analysis was performed using RevMan 5.4 software. Results     A total of 19 cohort studies and 1 randomized controlled study were collected, including 2 825 patients. The Newcastle-Ottawa Scale score for cohort studies was≥7 points. Meta-analysis showed that there was no statistical difference in the operative success rate (RR=1.01, 95%CI 1.00 to 1.02, P=0.17), incidence of occluder displacement/shedding (RR=0.77, 95%CI 0.26 to 2.27, P=0.63), incidence of arrhythmia (RR=0.50, 95%CI 0.21 to 1.14, P=0.10), incidence of pericardial effusion (RR=0.98, 95%CI 0.32 to 2.98, P=0.97), operative time (MD=–0.23, 95%CI –7.56 to 7.10, P=0.95) or cost (SMD=–0.39, 95%CI –1.09 to 0.30, P=0.27) between the two groups. The echocardiography group reduced the incidence of total postoperative complications (RR=0.42, 95%CI 0.30 to 0.60, P<0.001) and residual shunt (RR=0.70, 95%CI 0.50 to 0.98, P=0.04), and shortened length of hospital stay (MD=–0.43, 95%CI –0.77 to 0.09, P=0.01). Conclusion     Compared with traditional fluoroscopy-guided percutaneous closure of ASD, echocardiography guidance alone is equivalent in terms of operative success rate, major postoperative complications, operative time and total cost, but it reduces the incidence of total postoperative complications and residual shunt, and has a shorter length of hospital stay.

3.
Angew Chem Int Ed Engl ; 61(38): e202205796, 2022 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-35639438

RESUMO

Porous organic polymer films (PFs) with intrinsical porosity and tuneable pore environment are ideally suited for application in electronic devices. However, the huge challenges still exist for construction of electronic devices based on PFs owing to lack of robustness, processability, and controllable preparation. Herein, we report the electrochemical preparation of carbazole-based porous organic polymer films (eCPFs) as switchable materials for the memristors. These eCPFs possess the characteristics of controllable thickness/size, high stability, and excellent porosity. Carbazole and cyano groups are introduced into the eCPFs to constructing electron transfer systems. Thus, the memristors constructed based on these eCPFs exhibit excellent switching performance, reliability, and reproducibility. The electrochemically controllable preparation method of porous organic polymer membranes proposed in this paper provides a feasible idea for the developments of electronic devices.

4.
Chem Soc Rev ; 51(2): 761-791, 2022 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-34989729

RESUMO

Porous organic polymers (POPs) composed of organic building units linked via covalent bonds are a class of lightweight porous network materials with high surface areas, tuneable pores, and designable components and structures. Owing to their well-preserved characteristics in terms of structure and composition, POPs applied as electrocatalysts have shown promising activity and achieved considerable advances in numerous electrocatalytic reactions, including the hydrogen evolution reaction, oxygen evolution reaction, oxygen reduction reaction, CO2 reduction reaction, N2 reduction reaction, nitrate/nitrite reduction reaction, nitrobenzene reduction reaction, hydrogen oxidation reaction, and benzyl alcohol oxidation reaction. Herein, we present a systematic overview of recent advances in the applications of POPs in these electrocatalytic reactions. The synthesis strategies, specific active sites, and catalytic mechanisms of POPs are summarized in this review. The fundamental principles of some electrocatalytic reactions are also concluded. We further discuss the current challenges of and perspectives on POPs for electrocatalytic applications. Meanwhile, the possible future directions are highlighted to afford guidelines for the development of efficient POP electrocatalysts.

5.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-934251

RESUMO

3D visualization technology is the process of transforming two-dimensional image data into three-dimensional model with the help of computer software. 3D printing technology is the process of building organ solid model through 3D printing mechanism on the basis of 3D visualization. With the development of interventional technology for structural heart disease, 3D visualization and 3D printing technology have played a positive role in the understanding of cardiac anatomy and the formulation of personalized surgical plans. This paper will discuss the construction of 3D visualization model, review and analyze the application of 3D printing technology in interventional therapy of structural heart disease in recent years, discuss the future development in this field, and briefly analyze its existing problems.

6.
Nanotechnology ; 33(4)2021 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-34666325

RESUMO

Polyaniline, as a kind of conductive polymer with commercial application prospects, is still under researches in its synthesis and applications. In this work, polyaniline was fabricated on flexible substrates including carbon cloths and polyethylene naphthalate byin situelectropolymerization method. The synthesized flexible electrodes were characterized by scanning electron microscopy, High resolution transmission electron microscope, atomic force microscope, Fourier transform infrared, x-ray diffraction, and x-ray photoelectron spectroscopy. Owing to the conductivity and the reversible redox property, the polyaniline/carbon cloth electrodes show excellent properties such as decent supercapacitor performance and good detection capability toward ascorbic acid. As supercapacitors, the electrodes exhibit a specific capacitance as high as 776 F g-1at a current density of 1 A g-1and a long cycle life of 20 000 times in the three-electrode system. As ascorbic acid sensors, the flexible electrodes demonstrate stable response to ascorbic acid in the range of 1-3000µM with an outstanding sensitivity (4228µA mM-1cm-2), low detection limit (1µM), and a fast response time. This work holds promise for high-performance and low-cost flexible electrodes for both supercapacitors and non-enzymatic ascorbic acid sensors, and may inspire inventions of self-powered electrochemical sensor.

7.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-974367

RESUMO

Objective This study reconstructed 4D-CBCT for fully automatic compensated sliding motion by incorporating the bilateral filtering into the Deformable Vector Field (DVF). Methods First, a motion compensated simultaneous algebraic reconstruction technique (Modified Simultaneous Algebra Reconstruction Technique, mSART) was used to generate a high quality reference phase by using all phase projection stogether with the initial 4D-DVFs, which were generated via Demons registration between 0% phase and each other phaseimage. The 4D-DVF was optimized by matching the forward projection of the deformed 0% phase with the measured projection of the target phase. The loss function’s DVF smoothing constrain term contained bilateral filtering kernel that contained: 1) an spatial domain Guassian kernel; 2) animage intensity domain Guassian kernel; and 3) a DVF domain Guassian kernel. By choosing suitable kernel variances, the sliding motion can be extracted. A non-linear conjugate gradient optimizer wasused. We validated the algorithm on a Non-Uniform Rotational B- spline based Cardiac-Torso (NCAT) phantom. Quantification was evaluated by: 1) the Root-Mean-Square-Error (RMSE) together with the Maximum-Error (MaxE); 2) the Dice coefficient of the extracted lung contour from the final reconstructed images and 3) the relative reconstruction error (RE) to evaluate the algorithm's performance. Results The motion trajectory's RMSE/MaxEare 0.796/1.02 mm for bilateral filtering reconstruction; and 2.704/4.08 mm for original reconstruction. Image content such a stherib position, the hearted gedefinition, the fibrous structures all had been better corrected with bilateral filtering. Conclusion We developed a bilateral filtering based fully automatic sliding motion compensated 4D-CBCT scheme. Digital phantom study confirmed the improved motion estimation and image reconstruction ability. It can be used as a 4D-CBCT image guidance tool for lung SBRTtreatment.

8.
Arab J Gastroenterol ; 21(3): 169-173, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32732169

RESUMO

BACKGROUND AND STUDY AIMS: To investigate the role of low-concentration TRAIL on HBV replication and expression. MATERIAL AND METHODS: MTT assay was performed to determine the minimum concentrations of TRAIL protein in HepG2 cell apoptosis. HepG2 cells were transfected by HBV replication plasmid pHBV4.1. After the treatment with low concentration of TRAIL, the culture supernatant was collected to detect HBsAg and HBeAg by ELISA. Proteins were extracted from the resulted cells, followed by total RNA and HBV DNA intermediate replication. Southern Blot and Northern Blot were carried out to detect HBV RNA and HBV DNA replication intermediates, respectively. RT-PCR and Western Blot were carried out to detect gene and protein expressions for HNF4α, PPARα, and RXRα, respectively. RESULTS: 50 ng/ml of TRAIL protein led to significant decline on the secretions of HBsAg and HBeAg. Expression levels of HBV RNA and HBV DNA replication intermediates were significantly decreased too. In addition, gene and protein expressions of HNF4α, PPARα and RXRα also dropped, especially for PPARα whose expressions significantly decreased. CONCLUSION: TRAIL could inhibit HBV replication and expression by downregulating the expressions of liver-enriched transcription factors HNF4α, PPARα, and RXRα.


Assuntos
Vírus da Hepatite B , Ligante Indutor de Apoptose Relacionado a TNF , Fatores de Transcrição , Replicação Viral , DNA Viral , Células Hep G2 , Antígenos de Superfície da Hepatite B , Antígenos E da Hepatite B , Vírus da Hepatite B/genética , Humanos , Fígado , Ligante Indutor de Apoptose Relacionado a TNF/fisiologia
9.
J Hazard Mater ; 392: 122322, 2020 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-32097856

RESUMO

Flotation is an effective and clean separation technology to realize the recovery of metal in waste printed circuit boards (WPCBs). The flotation kinetic of metal and non-metal components was concerned in this study. In addition, the loading of bubbles, the collision and shedding of particles and bubbles were used to assist in proving the particle dynamics results. By analyzing the force on the particles, the load of bubbles on particles was analyzed, and the appropriate volume ratio of bubbles to particles was 1.5-8.0, depending on the particle density. Moreover, Clift model and Schiller-Naumann model has high fitting accuracy for the final bubble velocity. In addition, metal particles have greater settling velocity, which results in shorter collision time with bubbles. In the process of bubble-particle rising, the shedding probability gradually decreases, and the shedding probability of metal particles is much higher than that of non-metal particles. The results of flotation kinetics show that the removal of impurity particles represented by silicon mainly occurs in the initial stage of flotation process. The loss of copper increases with flotation time and collector dosage. This study reveals the flotation kinetics of particles from the perspectives of bubble loading, bubble-particle collision and shedding.

10.
Journal of Experimental Hematology ; (6): 1367-1375, 2020.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-827110

RESUMO

OBJECTIVE@#To investigate the killing effect of NK-92MI cells modified by chimeric antigen receptor (CD7-CAR) and specifically targeting CD7 to CD7 hematological malignant cells.@*METHODS@#Three types of hematological malignant tumor cells, including 5 cases of CD7 acute T-lymphoblastic leukemia (T-ALL), 10 cases of acute myeloid leukemia (AML) and 6 cases of T-cell lymphoma were collected, centrifuged, cultured and used to detect the expression levels of tumor cell surface targets; 7-AAD, CD56-APC, CD3-FITC, IgG Fc-PE flow cytometry were used to detected the transfection efficiency of NK-92MI and CD7-CAR-NK-92MI cells, killing efficiencies of CD7-CAR-NK-92MI cells to CD7 hematological tumor cells in vitro were determined by flow cytometry using PE Annexin V Apoptosis Detection Kit. Secretion differences of NK-92MI and CD7-CAR-NK-92MI cytokines interleukin (IL)-2, interferon (IFN)-γ, and granzyme B detection were estimated by using CBA kit.@*RESULTS@#The killing efficiencies of CD7-CAR-modified NK-92MI cells to CD7 T-ALL, AML, T-cell lymphoma tumor cells were significantly higher than those of NK-92MI cells without genetical modification. The difference showed statistically significant (P<0.05). The level of IFN-γ and granzyme B were significantly increased among cytokines secreted by CD7-CAR-modified NK-92MI cells as compared with those of NK-92MI cells without genetical modification (P<0.05) .@*CONCLUSION@#CD7-CAR-modified NK-92MI cells have significantly improved killing efficiency against CD7 T-ALL, AML and T lymphoma cells, and shows specific targeting effects, which provides a clinical basis for the treatment of CD7 hematological malignancies.


Assuntos
Humanos , Linhagem Celular Tumoral , Células Matadoras Naturais , Leucemia Mieloide Aguda , Receptores de Antígenos Quiméricos , Linfócitos T
11.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 50(3): 385-389, 2019 May.
Artigo em Chinês | MEDLINE | ID: mdl-31631608

RESUMO

OBJECTIVE: To synthesize and select an estrogen receptors aptamer that can be used in immunostaining of breast cancer tissues. METHODS: ER protein was purified. ER aptamer that showed a high affinity and specificity for ER was synthesized and selected and by SELEX. Ligand -receptor interactions assay was adopted to measure the affinity of the aptamer-ER complex. Both the biotinylated aptamer and the anti-ER monoclonal antibody were tested for immunohistochemical staining of ER status on 105 breast cancer samples. Agreement on the detection of ER expression was determined by Kappa statistics. RESULTS: The dissociation contant (Kd) of the biotinylated aptamer-ER complex, as calculated by a linear regression analysis, was determined to be (0.34±0.05) nmol/L ( n=3, r=0.989). The binding capacity (B max) was 769.23 fmol/(mg prot·nmol -1·L -1). The ER aptamer and the anti-ER antibody both exhibited identical specificity to ER-expressing breast cancer cells. There was a high agreement between the two methods ( n=105, Kappa value=0.943, 95% confident interval=0.879-1.006, P<0.05 for the ER positive and negtive samples; n=75, Kappa value=0.805, 95% confident interval=0.642-0.967, P<0.05 for the ER weak and moderate/strong expression samples). Both the anti-ER antibody and the ER aptamer can also recognized breast cancer cells at the same sites. There was no expression in the negative controls. There were also positive expressions in the 2 endometrial cancer tissues by using biotinylated aptamer. CONCLUSIONS: Our results indicated that the synthesized ER aptamer has a high affinity to bind ER. ER aptamer and the anti-ER antibody can both be used for immunohistochemical staining of ER status in breast cancer tissue.


Assuntos
Aptâmeros de Nucleotídeos/genética , Neoplasias da Mama/diagnóstico , Receptores de Estrogênio/genética , Feminino , Humanos , Técnica de Seleção de Aptâmeros , Sensibilidade e Especificidade
12.
Mikrochim Acta ; 186(9): 602, 2019 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-31377866

RESUMO

Considering the importance of dopamine (DA) detection for neuroscience and disease diagnosis, herein, an electrochemical sensor for dopamine is described. It is based on the use of a Ni-Co-P nanostructure fabricated on nickel foam via electrode position from cobalt chloride and ammonium phosphate for 10 min. Time-dependent experiments show the transformation of Ni-Co-P nanoparticles to spheres. The resulting electrode display excellent electrochemical response to DA. Figures of merit include (a) a working potential of 0.55 V (vs. Ag/AgCl); (b) an electrochemical sensitivity of 5262 µA mM-1 cm-2; (c) a wide linear range (from 0.5 to 2350 µM), and (d) a 1 µM detection limit. The outstanding electrochemical performance is explained by the synergistic effects of large surface area, improved electron transfer, presence of free binders, and the presence of three active components (nickel, cobalt and phosphonium ion). Graphical abstract A Ni-Co-P nanostructure was electrodeposited on nickel foam to obtain an electrochemical sensor for amperometric determination of dopamine with outstanding performance.


Assuntos
Cobalto/química , Dopamina/análise , Galvanoplastia , Níquel/química , Fósforo/química , Eletrodos , Nanoestruturas/química , Tamanho da Partícula , Propriedades de Superfície
13.
Am Surg ; 85(1): 86-91, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30760351

RESUMO

To conduct a randomized controlled trial (RCT), meta-analysis to assess the effectiveness of drains in reducing complications after laparoscopic cholecystectomy (LC) for acute cholecystitis needs to be carried out. An electronic search of PubMed, Embase, Science Citation Index, and the Cochrane Library from January 1990 to January 2018 was performed to identify randomized clinical trials that compare prophylactic drainage with no drainage in LC for acute cholecystitis. The outcomes were calculated as odds ratios (ORs) with 95 per cent confidence intervals (CIs) using RevMan 5.2. Four RCTs, which included 796 patients, were identified for analysis in our study. There was no statistically significant difference in the rate of morbidities (OR = 1.23, 95% CI 0.55-2.76, P = 0.61). Abdominal pain was more severe in the drain group 24 hours after surgery (mean difference = 0.80, 95% CI 0.47-1.14; P < 0.00001). No significant difference was present with respect to wound infection rate and hospital stay. The use of abdominal drainage does not appear to be of any benefit in patients having undergone early LC for acute cholecystitis.


Assuntos
Colecistectomia Laparoscópica/efeitos adversos , Colecistite Aguda/cirurgia , Drenagem , Complicações Pós-Operatórias/prevenção & controle , Humanos , Complicações Pós-Operatórias/epidemiologia
14.
Clin Res Hepatol Gastroenterol ; 43(3): 301-309, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30497844

RESUMO

AIM: This study aimed to investigate long-term kinetics of serum hepatitis B core-related antigen (HBcrAg) and its correlation with serum hepatitis B surface antigen (HBsAg) in a real-world cohort of patients who had received over 8 years of nucleos(t)ide analogs(NAs) therapy. METHODS: This was a retrospective study. All patients were recruited from our previous published study, who started therapy with NAs between 2007 and 2008. Serum HBcrAg and HBsAg levels were quantitatively measured at baseline, the sixth month and each year of follow-up, using the stored serum samples. RESULTS: Among the 94 patients, serum HBcrAg presented a gradually decreasing trend from baseline to year 8, either in HBeAg-negative or HBeAg-positive patients. After 8 years of NAs treatment, 21.3% of patients achieved serum HBcrAg < 3 log 10 U/mL, and only baseline HBcrAg was an independent predictor. Additionally, good correlation of HBcrAg and HBsAg was observed at baseline, but this correlation weakened remarkably during treatment. CONCLUSION: Serum HBcrAg is decreasing gradually with the duration of antiviral therapy, and baseline HBcrAg level is an independent predictor of long-term HBcrAg below the limit of detection.


Assuntos
Antivirais/uso terapêutico , Antígenos do Núcleo do Vírus da Hepatite B/sangue , Antígenos de Superfície da Hepatite B/sangue , Antígenos E da Hepatite B/sangue , Hepatite B Crônica/tratamento farmacológico , Soroconversão , Adenina/análogos & derivados , Adenina/uso terapêutico , Adulto , Feminino , Guanina/análogos & derivados , Guanina/uso terapêutico , Hepatite B Crônica/sangue , Humanos , Masculino , Organofosfonatos/uso terapêutico , Estudos Retrospectivos
15.
Biomed Pharmacother ; 110: 641-645, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30544063

RESUMO

TNF-related apoptosis inducing ligand (TRAIL) is a potential antitumor protein known for its ability to selectively eliminate various types of tumor cells without exerting toxic effects in normal cells and tissues. TRAIL has recently been suggested as a potential therapeutic target in hepatocellular carcinoma (HCC) because it promotes apoptosis in cancer cells. Furthermore, studies on the role of TRAIL in liver injury have reported that TRAIL plays an essential role in viral hepatitis, fatty liver diseases, etc. However, several contradictory and confounding effects of TRAIL in these liver diseases have not been fully elucidated or placed into perspective. Hence, this review summarizes recent progress in studies on TRAIL, including its role in apoptotic signaling, potential therapeutic applications of TRAIL in HCC, hepatitis virus infection, and liver fibrosis and cirrhosis.


Assuntos
Hepatopatias/tratamento farmacológico , Hepatopatias/metabolismo , Receptores do Ligante Indutor de Apoptose Relacionado a TNF/metabolismo , Ligante Indutor de Apoptose Relacionado a TNF/metabolismo , Animais , Anti-Inflamatórios/farmacologia , Anti-Inflamatórios/uso terapêutico , Humanos , Cirrose Hepática/tratamento farmacológico , Cirrose Hepática/metabolismo , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/metabolismo , Receptores do Ligante Indutor de Apoptose Relacionado a TNF/agonistas , Transdução de Sinais/efeitos dos fármacos , Transdução de Sinais/fisiologia , Ligante Indutor de Apoptose Relacionado a TNF/agonistas
16.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-689851

RESUMO

An ultra-performance liquid chromatography-tandem mass spectrometric method (UPLC-MS/MS) was developed in this study to simultaneously determine the contents of eight effective constituents in rat plasma, including baicalin, wogonoside, baicalein, liquiritin, glycyrrhizic acid, berberine hydrochloride, saikosaponin a and saikosaponin d in plasma of gastric ulcer rats, and investigate the pharmacokinetics of Modified Xiaochaihu Granules. Chromatographic separation was conducted on Zorbax SB-C₁₈ column (2.1 mm×100 mm, 1.8 μm) with acetonitrile -0.1% formic acid aqueous solution as the mobile phase for gradient elution, at a flow rate of 0.4 mL·min⁻¹ and column temperature of 40 °C. Detection was performed in the multiple reaction monitoring (MRM) mode with ESI ion source. All calibration curves showed good linearity (>0.996) over a wide concentration range for all constituents. RSDs of intra-day and inter-day precision were all within 15% and the extraction recoveries of all the constituents were in the range of 81.92% to 104.8%. The time to peak (tmax) of these eight constituents was (2.69±2.02), (5.17±2.04), (0.25±0), (0.83±0.26), (0.92±0.20), (0.92±0.20), (0.58±0.20), and (0.083±0) h, respectively; the half-life (t1/2) of them was (7.85±0.34), (10.16±2.21), (6.79±0.21), (8.32±0.48), (11.05±1.78), (11.56±3.46), (15.30±1.84), and (5.54±1.91) h, respectively; the peak concentration (Cmax) of them was (55.02±1.67), (213.66±4.62), (62.61±0.69), (68.43±1.42), (62.22±0.39), (30.17±1.89), (61.79±4.81), and (38.02±1.75) μg·L⁻¹, respectively. This established method is simple and accurate with good repeatability and strong specificity, which could provide modern experimental basis for modified Xiaochaihu granules in clinical treatment of gastric ulcer.

17.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-687246

RESUMO

To conduct the studies on serum pharmacochemistry of effective parts of modified Xiaochaihu Tang for treatment of gastric ulcer by using chromatography-mass spectrometry. Absolute ethyl alcohol induced-gastric ulcer model of mouse was used in this study to investigate the pharmacology of modified Xiaochaihu Tang and its effective parts. Both groups could significantly decrease the absolute ethyl alcohol induced-ulcer. Gasphase-mass spectrometry (GC-MS) was used to detect chemical compositions of volatile fractions and the drug components after gastric administration. A total of 63 compounds were identified in extracts, accounting for more than 93% of the all volatile oil, including 23.51% α-curcumene, 11.96% zingiberene, 9.56% curzerene, 6.54% β-sesquinene, 4.77% camphene, and 6 prototype components were also detected in serum for gastric ulcer model. In liquid chromatography-mass spectrometry (LC-MS), a total of 17 compounds were identified in extracts, 6 prototype components and 2 metabolites (3,5-O-feruloylquinic acid and palmatine) were obtained in serum. In a conclusion, this study provides an important scientific basis for identifying the active ingredients in modified Xiaochaihu Tang, and also helps to reveal the pharmacological effect of modified Xiaochaihu Tang for treatment of gastric ulcer.

18.
Scand J Gastroenterol ; 52(12): 1420-1426, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28880694

RESUMO

AIMS: This study aims to investigate the kinetics of serum HBsAg levels in chronic hepatitis B patients with long-term nucleos(t)ide analogs (NAs) therapy. METHODS: This was a retrospective clinical study. Serum HBsAg in serial samples of 94 patients, who received at least 8 years of NAs therapy, were measured using Elecsys® HBsAg II Quant Assay. RESULTS: In this cohort, serum HBsAg levels reduced from 3.80 log10 IU/mL at baseline to 2.72 log10 IU/mL at year 8 (p < .001), and the percentage of patients with HBsAg <1000 IU/mL increased from 14.9% at baseline to 55.3% at year 8 (p < .001). The reduction of serum HBsAg did not differ significantly between patients stratified by baseline virological parameters and type of antiviral agents. But as compared to patients without HBeAg seroconversion, HBsAg levels were significant lower in patients with HBeAg seroconversion (3.19 vs. 2.47 log10 IU/mL at year 8, p = .001). As compared to patients with slow (0-1 log10 IU/mL) or steady HBsAg(≤0 log10 IU/mL) decline at year 1, patients with a rapid HBsAg (≥1 log10 IU/mL) decline had a significantly lower HBsAg levels from year 2 to 8. However, Cox regression analysis showed that only absolute HBsAg levels at year 1 was an independent predictor of subsequent HBsAg <1000 IU/mL at year 8 of antiviral therapy(HR 0.242, p = .004). CONCLUSION: Pronounced HBsAg declines could be achieved in patients after long-term effective therapy with NAs, and on-treatment low serum HBsAg level at year 1 might be a predictor of serum HBsAg <1000 IU/mL at year 8.


Assuntos
Antivirais/uso terapêutico , Antígenos de Superfície da Hepatite B/sangue , Hepatite B Crônica/tratamento farmacológico , Nucleosídeos/uso terapêutico , Adulto , DNA Viral/sangue , Feminino , Antígenos E da Hepatite B/sangue , Vírus da Hepatite B/efeitos dos fármacos , Vírus da Hepatite B/genética , Hepatite B Crônica/sangue , Humanos , Masculino , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
19.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-333394

RESUMO

The original version of this article unfortunately contained a mistake. The presentation of the affiliation number was incorrect. The corrected one is given below.Zhong-zhu AI () 1†.

20.
The Journal of Practical Medicine ; (24): 2532-2535, 2017.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-611897

RESUMO

Objective To detect the serum levels of IL-6 and CRP in patients with acute type A aortic dissection complicated with pulmonary injury and inflammatory response. Methods From January 2007 Month to February 2016,216 patients with acute type A aortic dissection were admitted to our hospital. Among them,there were 120 male and 96 female patients,with a mean age of 52.1 years. All patients underwent cardiac ultrasound and other imaging studies. They were diagnosed and hospitalized immediately after the onset. Treatment lasted for more than 1 week. In a calm state of oxygen ,oxygenation index ≤200 preoperative lung injury is defined as positive. In this study ,according to the definition of the lung injury ,patients were divided into positive and negative lung injury groups. There were 72 positive and 144 negative cases among 216 patients. All patients were hospitalized. Every 4 hours,arterial oxygenation index is calculated. At the same time blood samples were tested for C-reactive protein(CRP)and interleukin-6(IL-6)levels. Data was analyzes by SPSS20.0 statistical software and counted byχ2 test. The results were plotted as the percentage,the measurement data with the t test,with(x ± s) to represent,evaluate serum levels of CRP and IL-6 levels with acute type A aortic dissection complicated by the relationship between lung injury. Results The differences of patients from two lung injury groups in gender,age, smoking,alcohol consumption,and other aspects of common chronic diseases were not significant(P>0.05);the difference between the pre-operative examination of several experimental studies in echocardiography were also no statistically significant(P > 0.05);two groups of patients,serum CRP positive group lung injury peak level and peak IL-6 levels were significantly higher in patients with acute lung injury negative group (P > 0.05). Further study of lung serum CRP in patients with damage to the relationship between IL-6 levels and oxygenation index found after dissection. Patient's oxygenation index decreased ,and serum C-reactive protein and interleukin-6 levels were rising rapidly ,reaching peak levels ,and then ,with the patients with inflammatory response decreased oxygenation index showed an upward trend. Conclusion Inflammatory reaction in acute type A aortic dissection plays a key role in the lung injury. In result ,patients'sicken time is prolonged ,which was closely related to serum C reactive protein(CRP),interleukin 6 levels and hypoxemia. Active anti-inflammation treatment before surgery may improve the patient's oxygenation status.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...