Pulm Circ ; 9(4): 2045894019878615, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31723407

RESUMO

BACKGROUND: The DelIVery for Pulmonary Arterial Hypertension clinical trial was a multi-center, prospective, single arm, Investigational Device Exemption study utilizing a fully implantable, programmable intravascular delivery system consisting of a pump and a catheter for intravenous treprostinil. The study met its primary endpoint and demonstrated that the intravascular delivery system significantly reduced catheter related complications at 22,000 subject-days of follow-up compared with a predefined objective performance criterion. Here we summarize the results obtained during a 6.4-year follow-up period. METHODS: Throughout study follow-up, participants had clinic visits and medication refills at least every 12 weeks (dependent on the subjects' dose). All adverse events and intravascular delivery system complications were evaluated and recorded. RESULTS: Sixty pulmonary arterial hypertension subjects were followed post device implantation for approximately 282 patient-years (range 87 days to 6.4 years). Of the 60 subjects, 14 died (1 related to intravascular delivery system pump failure), 2 withdrew after lung transplants, and 2 withdrew due to pump pocket infection. No catheter-related bloodstream infections, catheter thrombosis or occlusions, or catheter kinks occurred through 282 patient-years. Two participants had adverse events of abdominal pain, rash, due to subcutaneous treprostinil "leaks" after one catheter puncture and one catheter laceration during pump refill and replacement, respectively. Eight pump failure events occurred: seven pump motor stalls and one early replacement (faulty battery). CONCLUSION: Delivery of treprostinil with an intravascular delivery system is a safe alternative to an external delivery system, while providing enhanced life experiences. To preserve the risk-benefit ratio, treatment at specialized pulmonary arterial hypertension centers is recommended until training is disseminated at other sites.

2.
Chest ; 152(6): 1128-1134, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28583617

RESUMO

BACKGROUND: Prostacyclins improve symptoms and survival in pulmonary arterial hypertension (PAH). In response to risks associated with external delivery systems, an implantable IV infusion system was developed. A multicenter, prospective, single-arm, clinical trial (DelIVery for PAH) was conducted to evaluate this system for treprostinil in PAH. This analysis describes the findings related to the implant procedure. METHODS: Patients (N = 64) with PAH (World Health Organization group 1) receiving stable IV treprostinil were enrolled. Patients were transitioned to a temporary peripheral IV infusion catheter prior to the procedure. System implantation was performed at 10 centers under general anesthesia or deep IV sedation by clinicians from various specialties. Central venous access was via the cephalic, subclavian, jugular, or axillary vein. Using an introducer and fluoroscopic guidance, the distal tip of the infusion catheter was placed at the superior caval-atrial junction. The catheter was tunneled from the venous access site to an abdominal subcutaneous pocket, where the pump was placed. RESULTS: Of the 64 patients enrolled, four exited prior to implantation. All 60 implant procedures were successful. At baseline, all patients were receiving treprostinil via an external pump at a mean dose of 71.4 ± 27.8 ng/kg/min (range: 22-142 ng/kg/min). The implant averaged 102 ± 32 min (range: 47-184 min). Clinically significant implant procedure-related complications included one pneumothorax, two infections, and one episode of atrial fibrillation. There were three postimplantation catheter dislocations in two patients. Common implant-related events that were not complications included implant site pain (83%) and bruising (17%). CONCLUSIONS: The procedure for inserting a fully implantable system for treprostinil was successfully performed, with few complications. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT01321073; URL: www.clinicaltrials.gov.


Assuntos
Cateterismo Venoso Central/métodos , Epoprostenol/análogos & derivados , Hipertensão Pulmonar/tratamento farmacológico , Bombas de Infusão Implantáveis , Anti-Hipertensivos/administração & dosagem , Relação Dose-Resposta a Droga , Epoprostenol/administração & dosagem , Feminino , Seguimentos , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/fisiopatologia , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Pressão Propulsora Pulmonar/efeitos dos fármacos , Resultado do Tratamento
3.
Chest ; 150(1): 27-34, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27396777

RESUMO

BACKGROUND: The use of systemic prostanoids in severe pulmonary arterial hypertension (PAH) is often limited by patient/physician dissatisfaction with the delivery methods. Complications associated with external pump-delivered continuous therapy include IV catheter-related bloodstream infections and subcutaneous infusion site pain. We therefore investigated a fully implantable intravascular delivery system for treprostinil infusion. METHODS: A multicenter, prospective, single-arm, clinical trial (DelIVery for Pulmonary Arterial Hypertension) was conducted by using an implantable intravascular delivery system. The implanted pumps were refilled percutaneously at least every 12 weeks. The primary end point was the rate of catheter-related complications using the new model 10642 catheter compared with a predefined objective performance criterion of 2.5 per 1,000 patient-days based on the literature. RESULTS: Patients (n = 60) with severe PAH (World Health Organization group 1) receiving a stable dose of IV treprostinil for at least 4 weeks received an implant device and were followed up for 12.1 ± 4.4 months. Six catheter-related complications occurred, corresponding to a complication rate of 0.27 per 1,000 patient-days. The 97.5% upper one-sided confidence bound of 0.59 was less than the predefined criterion of 2.5 per 1,000 patient-days (P < .0001). Plasma treprostinil levels at 1 week postimplantation were highly correlated with baseline levels (r = 0.91; P < .0001). The delivery system management time as reported by the patients was 2.5 ± 1.7 hours per week preimplantation, and this time decreased to 0.6 ± 0.8 hour per week at 6 months' postimplantation (P < .0001). All patients rated overall satisfaction with the implantable system as good, very good, or excellent at 6 weeks and 6 months. There were no catheter-related bloodstream infections or catheter occlusions. CONCLUSIONS: The implantable intravascular delivery system delivered treprostinil to patients with PAH with a low rate of catheter-related complications and a high rate of patient satisfaction. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT01321073; URL: www.clinicaltrials.gov.


Assuntos
Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Epoprostenol/análogos & derivados , Hipertensão Pulmonar/tratamento farmacológico , Bombas de Infusão Implantáveis/efeitos adversos , Adulto , Anti-Hipertensivos/administração & dosagem , Obstrução do Cateter/estatística & dados numéricos , Infecções Relacionadas a Cateter/diagnóstico , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/etiologia , Monitoramento de Medicamentos/métodos , Monitoramento de Medicamentos/estatística & dados numéricos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/diagnóstico , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/etiologia , Epoprostenol/administração & dosagem , Feminino , Humanos , Hipertensão Pulmonar/diagnóstico , Bombas de Infusão Implantáveis/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Estudos Prospectivos , Estados Unidos