Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Turk J Pediatr ; 65(5): 868-873, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37853978

RESUMO

BACKGROUND: IgA vasculitis (IgAV) is a multisystemic small vessel vasculitis and is the most common vasculitis in childhood. The characteristic findings of IgAV are palpable purpuric rash, abdominal pain, arthralgia or arthritis, and hematuria. Ischemic complications are very rare in IgAV. Thrombotic complications can be observed after a COVID-19 infection. Also in the presence of familial Mediterranean fever, IgAV may have an atypical or more severe course. CASE: We present a case of IgAV complicated with renal infarction and intestinal ischemia. There was no recent or distant history of COVID-19 in the patient or family members, but the patient`s COVID-19 antibody was positive. In addition, MEFV gene analysis of the patient showed homozygous M694V mutation. The patient did not respond to enoxaparin, pulse methylprednisolone, intravenous immunoglobulin (IVIG), iloprost, and cyclophosphamide treatments. She was successfully treated with six sessions of plasmapheresis. CONCLUSIONS: Plasmapheresis seems to be an effective treatment option in IgAV-related ischemic findings that do not respond to intensive immunosuppressive therapy.


Assuntos
COVID-19 , Vasculite por IgA , Vasculite , Feminino , Humanos , Vasculite por IgA/complicações , Vasculite por IgA/terapia , Imunoglobulina A , Vasculite/complicações , Vasculite/terapia , Plasmaferese , Pirina
2.
Am J Perinatol ; 2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37751851

RESUMO

OBJECTIVE: Point-of-care ultrasound (POCUS) has been reported to reduce radiation exposure and has been shown to be a reliable bedside technique to confirm endotracheal tube (ETT) placement, but evidence in neonates is still limited. The aim of this study was to compare the effectiveness and reliability of POCUS performed by a neonatologist, as an alternative to chest radiography (CXR) for the optimal position of ETT. STUDY DESIGN: Newborns who underwent intubation were included in this prospective observational study. The CXR was used to evaluate the position of the ETT tip and categorized into three groups: above the T1, between the T1 and T3, and below the T3 vertebra. An experienced neonatologist measured the distance between the ETT tip and the upper border of the aortic arch from the suprasternal notch with ultrasonography (US). A 5 to 10 mm measurement was considered as the optimal distance, and the position was classified into three categories: correct, high, and deep. RESULTS: Among 91 measurements performed on 63 intubated patients with US, 73 (80%) were within the 5 to 10 mm range (correct position). Of these, 61 (92.4%) were determined to be between T1 and 3 vertebrae in CXR. There was no significant difference between the two methods, and the US had an excellent ability to distinguish the correct position of the ETT. The distance measured by the US for the ETT tip to be located between the T1 and T3 vertebrae on CXR should range between 6.17 and 9.0 mm. CONCLUSION: This study showed that the US by an experienced neonatologist is an easy and feasible alternative to determine the position of the ETT in the neonatal intensive care unit. KEY POINTS: · POCUS has been reported to reduce radiation exposure, and it is areliable bedside technique.. · Evidence for confirmation of ETT placement in neonates is limited.. · POCUS can be used for determination of ETT position in NICU's by experienced neonatologists..

3.
Neonatology ; 120(6): 736-740, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37634488

RESUMO

INTRODUCTION: Chest X-ray (CXR) is the most prevalent method for evaluating lung expansion in high-frequency oscillatory ventilation (HFOV). The purpose of this study was to compare the accuracy of chest radiography with point-of-care ultrasound (POCUS) in determining lung expansion. METHODS: This prospective study included newborns who required HFOV and were monitored in a neonatal intensive care unit. A single neonatologist assessed lung expansion with CXR and POCUS to measure the costal level of the right hemidiaphragm and compared the results. RESULTS: A neonatologist performed 55 measurements in 28 newborns with a gestational age of 32 (23.2-39.4) weeks, followed by HFOV. The rib counts obtained from anterior chest ultrasonography and posterior CXR showed a statistically high concordance (r = 0.913, p < 0.001). CONCLUSION: Lung ultrasonography is a reliable method for the evaluation of lung expansion based on rib count in patients with HFOV.


Assuntos
Ventilação de Alta Frequência , Síndrome do Desconforto Respiratório do Recém-Nascido , Recém-Nascido , Humanos , Lactente , Estudos Prospectivos , Sistemas Automatizados de Assistência Junto ao Leito , Raios X , Ultrassonografia , Radiografia , Pulmão/diagnóstico por imagem , Costelas/diagnóstico por imagem
4.
North Clin Istanb ; 10(2): 131-138, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37181062

RESUMO

OBJECTIVE: Because of the immature bone marrow signal in children, assessment of the sacroiliac joint is more difficult than in adults. Aim of this study is to evaluate the efficacy of diffusion-weighted imaging (DWI) in sacroiliac joint magnetic resonance imaging (MRI). METHODS: Sacroiliac joint MRI, including DWI sequences, were evaluated by two pediatric radiologists in 54 patients with sacroiliitis and 85 completely normal controls. In MRI evaluation, subchondral bone marrow edema and contrast enhancement in the sacroiliac joints were considered as active sacroiliitis. Apparent diffusion coefficient (ADC) measurements were made in six areas from each sacroiliac joint. A total of 1668 fields were evaluated retrospectively without their diagnosis being known. RESULTS: When the postcontrast T1W series were referenced, the sensitivity, specificity, positive predictive value, and negative predictive value of short time inversion recovery (STIR) images in the diagnosis of sacroiliitis were 88%, 92%, 83% and 94% respectively, compared to contrast-enhanced images. False positive results in STIR images were observed secondary to the flaring signal in the immature bone marrow. ADC measurements obtained from diffusion-weighted images were recorded in all patients and healthy groups. The ADC values were 1.35x10-3 mm2/s (SD: 0.21) in the areas of sacroiliitis, 0.44x10-3 mm2/s (SD: 0.71) in the normal bone marrow and 0.72x10-3 mm2/s (SD: 0.76) in the immature bone marrow areas. CONCLUSION: Although STIR studies are an effective sequence in the diagnosis of sacroiliitis, they cause false positive results in immature bone marrow in children in inexperienced hands. DWI is an objective method that prevents errors in the assessment of sacroiliitis by means of ADC measurements in the immature skeleton. In addition, it is a short and effective MRI series that makes important contributions to the diagnosis without the need for contrast-enhanced examinations in children.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...