Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Int J Mol Sci ; 19(10)2018 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-30332778

RESUMO

Thrombospondin-1-deficient (TSP-1-/-) mice are used as an animal model of Sjögren's Syndrome because they exhibit many of the symptoms associated with the autoimmune type of dry eye found in primary Sjögren's Syndrome. This type of dry eye is linked to the inflammation of the lacrimal gland, conjunctiva, and cornea, and is thought to involve dysfunction of the complex neuronal reflex arc that mediates tear production in response to noxious stimuli on the ocular surface. This study characterizes the structural and functional changes to the corneal nerves that are the afferent arm of this arc in young and older TSP-1-/- and wild type (WT) mice. The structure and subtype of nerves were characterized by immunohistochemistry, in vivo confocal microscopy, and confocal microscopy. Cytokine expression analysis was determined by Q-PCR and the number of monocytes was measured by immunohistochemistry. We found that only the pro-inflammatory cytokine MIP-2 increased in young corneas of TSP-1-/- compared to WT mice, but tumor necrosis factor-α (TNF-α), monocyte chemoattractant protein-1 (MCP-1), and macrophage inflammatory protein-2 (MIP-2) all increased in older TSP-1-/- mouse corneas. In contrast, CD11b+ pro-inflammatory monocytes did not increase even in older mouse corneas. Calcitonin gene-related peptide (CGRP)-, but not Substance P (SubP)-containing corneal nerves decreased in older, but not younger TSP-1-/- compared to WT mouse corneas. We conclude that CGRP-containing corneal sensory nerves exhibit distinct structural deficiencies as disease progresses in TSP-1-/- mice, suggesting that: (1) TSP-1 is needed for the development or repair of these nerves and (2) impaired afferent corneal nerve structure and hence function may contribute to ocular surface dysfunction that develops as TSP-1-/- mice age.


Assuntos
Córnea/inervação , Córnea/patologia , Regeneração Nervosa , Trombospondina 1/metabolismo , Animais , Peptídeo Relacionado com Gene de Calcitonina/metabolismo , Contagem de Células , Quimiocina CCL2/metabolismo , Quimiocina CXCL2/metabolismo , Córnea/metabolismo , Substância Própria/patologia , Epitélio Corneano/patologia , Camundongos , Monócitos/metabolismo , Coloração e Rotulagem , Substância P/metabolismo , Fator de Necrose Tumoral alfa/metabolismo
3.
Sci Rep ; 4: 6680, 2014 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-25338290

RESUMO

Ocular graft-versus-host disease (GVHD) is a common complication after hematopoietic stem cell transplantation (HSCT). Here we compared the diagnostic rates of ocular GVHD, including its severity, prognosis and the agreement, obtained using three grading scales: the National Institutes of Health (NIH) eye score, Japanese dry eye score, and dry eye workshop score, by retrospectively reviewing the records of 82 patients who underwent HSCT. Tear dynamics and ocular surface assessments made 6-9 months after HSCT were used to determine ocular GVHD severity with the three scales. By the three scales, ocular GVHD was diagnosed in 56 patients (68.3%), 51 patients (62.2%), and 52 patients (63.4%), respectively. The Kappa coefficient was calculated to determine the agreement between scales for diagnosing ocular GVHD. The severity progression within two years after onset was also assessed by tear dynamics and ocular surface examination. The patients were categorized as no change, improved, or progressive. The three grading scales showed good agreement (Kappa = 0.87 to 0.97) in diagnosing patients with ocular GVHD, and the scores by all three were significantly associated with the patients' prognosis (p < 0.01). We recommend that multi-center research is needed for further validation and investigation.


Assuntos
Oftalmopatias/diagnóstico , Doença Enxerto-Hospedeiro/diagnóstico , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Prognóstico , Adulto , Olho/patologia , Oftalmopatias/etiologia , Oftalmopatias/patologia , Feminino , Doença Enxerto-Hospedeiro/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estados Unidos
4.
Mol Vis ; 17: 2533-43, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22025888

RESUMO

PURPOSE: To evaluate the morphological changes of the meibomian glands (MGs) using in vivo laser confocal microscopy (CM) in dry eye (DE) patients with chronic graft-versus-host disease (cGVHD). METHODS: Seventeen eyes from 9 patients with a diagnosis of DE associated with cGVHD (DE/cGVHD group; 6 males, 3 females; median 50.5 years) and 16 eyes of 8 hematopoietic stem cell transplantation (HSCT) recipients without DE (non-DE/non-cGVHD group; 5 males, 3 females; median 47.0 years) were enrolled. CM was used to investigate the MG and MG acinar unit density (MGAUD), MG acinar longest diameter (MGALD), MG acinar shortest diameter (MGASD), and the fibrosis grade. Clinical findings of the lid margin were obtained. Tear dynamics, ocular surface vital staining, meibography, and MG expressibility were also examined. Data were compared between the 2 groups using the unpaired t and Mann-Whitney tests. RESULTS: The mean MGAUD value was significantly lower in the DE/cGVHD group than in the non-DE/non-cGVHD group (p=0.01, 57.8±38.3 glands/mm(2), 88.8±26.6 glands/mm(2), respectively), and the mean MGALD and MGASD were significantly shorter in the DE/cGVHD group than in the non-DE/non-cGVHD group (p=0.0018, 37.3±24.4 µm and 60.4±11.8 µm, p=0.0106, 17.7±11.8 µm and 26.6±6.03 µm, respectively). The mean fibrosis grade was significantly higher in the DE/cGVHD group than the non-DE/non-cGVHD group (p<0.0001, 1.39±0.71 grade, 0.06±0.25 grade, respectively). Clinical findings in the lid margin, tear dynamics, and ocular surface findings were significantly worse in the DE/cGVHD group than in the non-DE/non-cGVHD group. CONCLUSIONS: CM clearly depicted the morphological changes of the MG in the DE/cGVHD group, and revealed the severity of the meibomian gland dysfunction. Patients with severe DE after HSCT showed atrophic MG and excessive fibrosis.


Assuntos
Síndromes do Olho Seco/patologia , Fibrose/patologia , Doença Enxerto-Hospedeiro/patologia , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Glândulas Tarsais/patologia , Microscopia Confocal/métodos , Adulto , Estudos de Casos e Controles , Doença Crônica , Síndromes do Olho Seco/etiologia , Feminino , Fibrose/etiologia , Doença Enxerto-Hospedeiro/etiologia , Humanos , Japão , Lasers , Masculino , Glândulas Tarsais/ultraestrutura , Pessoa de Meia-Idade , Estudos Prospectivos , Lágrimas/fisiologia
5.
Am J Ophthalmol ; 151(3): 483-7.e1, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21232733

RESUMO

PURPOSE: To report the rate of recanalization and the efficacy of punctal occlusion surgery with a high heat-energy-releasing cautery device in patients with severe dry eye disease and recurrent punctal plug extrusion. DESIGN: Prospective, interventional case series. METHODS: Seventy puncta from 44 eyes of 28 dry eye patients underwent punctal occlusion with thermal cautery. All patients had a history of recurrent punctal plug extrusion. A high heat-energy-releasing thermal cautery device (Optemp II V; Alcon Japan) was used for punctal occlusion surgery. Symptom scores, best-corrected visual acuity, fluorescein staining score, rose bengal staining score, tear film break-up time, and Schirmer test values were compared before and 3 months after the surgery. Rate of punctal recanalization also was examined. RESULTS: Three months after surgical cauterization, symptom score decreased from 3.9 ± 0.23 to 0.56 ± 0.84 (P < .0001). Logarithm of the minimal angle of resolution best-corrected visual acuity improved from 0.11 ± 0.30 to 0.013 ± 0.22 (P = .003). Fluorescein staining score, rose bengal staining score, tear film break-up time, and the Schirmer test value also improved significantly after the surgery. Only 1 of 70 puncta recanalized after thermal cauterization (1.4%). CONCLUSIONS: Punctal occlusion with the high heat-energy-releasing cautery device not only was associated with a low recanalization rate, but also with improvements in ocular surface wetness and better visual acuity.


Assuntos
Cauterização/instrumentação , Síndromes do Olho Seco/cirurgia , Pálpebras/cirurgia , Aparelho Lacrimal/cirurgia , Próteses e Implantes , Falha de Prótese , Idoso , Síndromes do Olho Seco/fisiopatologia , Feminino , Fluorofotometria , Humanos , Masculino , Estudos Prospectivos , Lágrimas/fisiologia , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...