Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur Radiol ; 29(1): 287-298, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29948079

RESUMO

OBJECTIVES: Prostate artery embolisation (PAE) is a new minimally invasive treatment for lower urinary tract symptoms (LUTS) in men with benign prostatic hyperplasia (BPH). The purpose of this study was to review the efficacy and safety of PAE in the treatment of BPH with LUTS. METHODS: A systematic review performed according to the PRISMA guidelines with a pre-specified search strategy for PubMed, Web of Science, Cochrane Library and Embase databases protocol (PROSPERO ID: CRD42017059196). Trials studying the efficacy of prostate artery embolisation to treat LUTS with more than ten participants and follow-up longer than 6 months were included by two independent authors. Outcomes investigated were International Prostate Symptom Score (IPSS), quality of life (QoL), International Index of Erectile Function (IIEF-5), prostate volume (PV), prostate-specific antigen (PSA), peak void flow (Qmax), post-void residual (PVR) and complications. To summarise mean change from baseline, a meta-analysis was done using the random-effects model. RESULTS: The search returned 210 references, of which 13 studies met the inclusion criteria, representing 1,254 patients. Patients in the included studies with data available for meta-analysis had moderate to severe LUTS and a mean IPSS of 23.5. Statistically significant (p value < 0.05) improvements of all investigated outcomes were seen at 12-month follow-up. Major complications were reported in 0.3% of the cases. CONCLUSIONS: Our findings suggest that PAE can reduce moderate to severe LUTS in men with BPH with a low risk of complications. KEY POINTS: • Prostate artery embolisation (PAE) improved International Prostate Symptom Score (IPSS) by 67%. • Major complications after PAE are very rare. • Use of cone-beam CT may reduce risk of non-target embolisation.


Assuntos
Embolização Terapêutica/métodos , Próstata/irrigação sanguínea , Hiperplasia Prostática/terapia , Artérias , Tomografia Computadorizada de Feixe Cônico , Humanos , Masculino , Próstata/diagnóstico por imagem , Hiperplasia Prostática/diagnóstico , Resultado do Tratamento
2.
Eur J Vasc Endovasc Surg ; 52(6): 729-734, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27760698

RESUMO

OBJECTIVE/BACKGROUND: Surveillance after endovascular aortic aneurysm repair (EVAR) is mandatory and computed tomography angiography (CTA) is considered the standard imaging modality, although patients are exposed to ionizing radiation and nephrotoxic contrast medium. The primary aim of this study was to determine the diagnostic efficacy of duplex ultrasound (DUS) and contrast enhanced ultrasound (CEUS) using CTA as the gold standard. The secondary aim was to determine the clinical consequences of endoleaks missed by DUS and CEUS, or CTA. METHODS: All patients with EVAR for an aorto-iliac aneurysm between 1 August 2011 and 31 October 2014 were prospectively and consecutively enrolled. CEUS was added to the existing surveillance protocol, which included DUS, plain abdominal X-ray, and CTA at 3 and 12 months after stent implantation. RESULTS: In 278 patients, endoleaks were detected in 68, 69, and 46 cases by CTA, CEUS, and DUS, respectively. The sensitivity and specificity of DUS and CEUS were 46% and 93%, and 85% and 95%, respectively. CEUS and CTA were diagnostically equivalent, as opposed to DUS and CTA (p = .002). Endoleaks detected by CTA led to re-intervention in 11 (4%) patients. These endoleaks were also detected by CEUS; however, three out of 11 patients were missed by DUS and underwent re-intervention: limb extension, re-cuff, and attempt to coil lumbar leaks. Endoleaks missed by CEUS or CTA were type II endoleaks without sac expansion. CONCLUSION: In surveillance programs after EVAR a diagnostic CEUS examination may replace CTA.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares , Fosfolipídeos/administração & dosagem , Hexafluoreto de Enxofre/administração & dosagem , Ultrassonografia Doppler Dupla/métodos , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Estudos Transversais , Erros de Diagnóstico , Endoleak/etiologia , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento
4.
Eur J Vasc Endovasc Surg ; 48(5): 527-33, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24878235

RESUMO

OBJECTIVE: To assess the incidence and outcome of graft limb occlusions after endovascular aortic repair (EVAR) of abdominal aortic aneurysm (AAA) in a high volume single centre. To quantify iliac artery tortuosity in patients with AAA and correlate this with limb occlusion. DESIGN: Data were collected consecutively and prospectively, and analyzed retrospectively. MATERIALS: Patients treated with Zenith bifurcated stent grafts from January 2000 to December 2010 at a tertiary referral vascular unit were analyzed. Routine regular office follow-up with computed tomography angiography (CTA) and, subsequently, duplex ultrasound imaging was performed. Patients with limb occlusions were identified. For each index patient, two controls were obtained, one immediately preceding and one following the index patient in the consecutive cohort of EVAR patients. METHODS: Demographics and CTA data on limb graft occlusions were recorded and compared with a defined control group. Three different indices were used to describe the tortuosity of the iliac vessels based on preoperative CTA: pelvic artery index of tortuosity (PAI), common iliac artery index of tortuosity (CAI), and a visual description of vessel tortuosity - the double iliac sign (DIS). Demographic data and indices were correlated for later occurring limb occlusion. RESULTS: 504 patients underwent EVAR and 18 patients experienced graft limb occlusion during a median follow-up of 28 months (range 0-133). Primary graft patency was 97% at 1 year and 96% at 3 years. Logistic regression showed that iliac artery tortuosity (DIS) (p = .001) and body mass index (p = .007) had a significant impact on graft patency. CONCLUSION: A tortuous vessel on the preoperative CTA is associated with an increased risk of limb occlusion after EVAR. Adjunctive stenting of iliac segments deemed at risk is suggested, which is achieved without compromise of the aneurysm repair.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/efeitos adversos , Oclusão de Enxerto Vascular/epidemiologia , Artéria Ilíaca/cirurgia , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Aortografia/métodos , Feminino , Oclusão de Enxerto Vascular/etiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório , Estudos Retrospectivos , Medição de Risco , Stents , Resultado do Tratamento
5.
Eur J Vasc Endovasc Surg ; 46(5): 525-32, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24091092

RESUMO

OBJECTIVES: Discrepancy between maximum diameters obtained with two-dimensional ultrasound and computed tomography (CT) after endovascular aneurysm repair (EVAR) is well known. The maximal diameter is ideally measured perpendicular to the centerline, a methodology so far only feasible with three-dimensional (3D) CT and magnetic resonance angiography (MRA). We aimed to investigate the agreement between 3D ultrasound and 3D CT and to determine reproducibility measures. METHODS: Prospective study comparing 3D ultrasound with 3D CT in 124 consecutive patients seen 3 or 12 month after EVAR. RESULTS: Replacing 2D with 3D ultrasound, the mean difference was improved from 6.0 mm to -1.3 mm (p < .001), and the range of variability was reduced from 9.4 mm to 6.6 mm (p = .009) using 3D CT as the gold standard. The mean difference between 3D ultrasound and 3D CT maximum diameter of the residual sac was -1.3 mm with upper and lower limits of agreement of 5.2 mm and -7.9 mm, respectively. Reproducibility measures of 3D ultrasound were ± 4 mm. CONCLUSION: 3D ultrasound correlate significantly better to 3D CT than the currently used 2D ultrasound method when assessing maximum diameter of the residual sac after EVAR, and reproducibility measures were within clinical acceptable values.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Ultrassonografia de Intervenção , Idoso , Idoso de 80 Anos ou mais , Aortografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Resultado do Tratamento
6.
Eur J Vasc Endovasc Surg ; 45(5): 450-5; discussin 456, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23433497

RESUMO

OBJECTIVES: Volume estimation is more sensitive than diameter measurement for detection of aneurysm growth after endovascular aneurysm repair (EVAR), but this has only been confirmed on three-dimensional, reconstructed computer tomography (3-D CT). The potential of 3-D ultrasound (3-D US) for volume estimation in EVAR surveillance is unknown. DESIGN: Prospective validation study comparing 3-D US with 3-D CT, using 3-D CT as the gold standard. MATERIALS AND METHODS: From August 2011 to March 2012, 93 consecutive EVAR patients were enrolled and examined with both 3-D US and CT angiography (CTA). Image data were analysed in a mutual blinded setup using a 3-D interactive segmentation technique. RESULTS: The technical success rate of 3D-US was 98% (91/93). In 91 EVAR patients (F/M; 10/81) eligible for further analysis, the mean maximum volume (SD) was 126 (58) ml using 3-D US and 128 (58) ml using 3-D CT. The mean difference was 1 ml (0.4%) and the limits of agreement were -14 to 16 ml (-11; 12%). CONCLUSION: Volume estimation of the aortic sac after EVAR using 3-D US is a feasible and accurate method using 3-D CT as the gold standard.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Procedimentos Endovasculares , Imageamento Tridimensional , Ultrassonografia de Intervenção , Idoso , Aneurisma Aórtico/patologia , Feminino , Humanos , Masculino , Tamanho do Órgão , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...