Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Adv ; 5(3): eaau8044, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30873430

RESUMO

Under rapid high-temperature, high-pressure loading, lattices exhibit complex elastic-inelastic responses. The dynamics of these responses are challenging to measure experimentally because of high sample density and extremely small relevant spatial and temporal scales. Here, we use an x-ray free-electron laser providing simultaneous in situ direct imaging and x-ray diffraction to spatially resolve lattice dynamics of silicon under high-strain rate conditions. We present the first imaging of a new intermediate elastic feature modulating compression along the axis of applied stress, and we identify the structure, compression, and density behind each observed wave. The ultrafast probe x-rays enabled time-resolved characterization of the intermediate elastic feature, which is leveraged to constrain kinetic inhibition of the phase transformation between 2 and 4 ns. These results not only address long-standing questions about the response of silicon under extreme environments but also demonstrate the potential for ultrafast direct measurements to illuminate new lattice dynamics.

2.
Phys Rev Lett ; 123(24): 245501, 2019 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-31922830

RESUMO

We present molecular dynamics simulations of shock and release in micron-scale tantalum crystals that exhibit postbreakout temperatures far exceeding those expected under the standard assumption of isentropic release. We show via an energy-budget analysis that this is due to plastic-work heating from material strength that largely counters thermoelastic cooling. The simulations are corroborated by experiments where the release temperatures of laser-shocked tantalum foils are deduced from their thermal strains via in situ x-ray diffraction and are found to be close to those behind the shock.

3.
Phys Rev Lett ; 120(26): 265502, 2018 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-30004719

RESUMO

We have used femtosecond x-ray diffraction to study laser-shocked fiber-textured polycrystalline tantalum targets as the 37-253 GPa shock waves break out from the free surface. We extract the time and depth-dependent strain profiles within the Ta target as the rarefaction wave travels back into the bulk of the sample. In agreement with molecular dynamics simulations, the lattice rotation and the twins that are formed under shock compression are observed to be almost fully eliminated by the rarefaction process.

4.
Nature ; 550(7677): 496-499, 2017 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-29072261

RESUMO

Pressure-driven shock waves in solid materials can cause extreme damage and deformation. Understanding this deformation and the associated defects that are created in the material is crucial in the study of a wide range of phenomena, including planetary formation and asteroid impact sites, the formation of interstellar dust clouds, ballistic penetrators, spacecraft shielding and ductility in high-performance ceramics. At the lattice level, the basic mechanisms of plastic deformation are twinning (whereby crystallites with a mirror-image lattice form) and slip (whereby lattice dislocations are generated and move), but determining which of these mechanisms is active during deformation is challenging. Experiments that characterized lattice defects have typically examined the microstructure of samples after deformation, and so are complicated by post-shock annealing and reverberations. In addition, measurements have been limited to relatively modest pressures (less than 100 gigapascals). In situ X-ray diffraction experiments can provide insights into the dynamic behaviour of materials, but have only recently been applied to plasticity during shock compression and have yet to provide detailed insight into competing deformation mechanisms. Here we present X-ray diffraction experiments with femtosecond resolution that capture in situ, lattice-level information on the microstructural processes that drive shock-wave-driven deformation. To demonstrate this method we shock-compress the body-centred-cubic material tantalum-an important material for high-energy-density physics owing to its high shock impedance and high X-ray opacity. Tantalum is also a material for which previous shock compression simulations and experiments have provided conflicting information about the dominant deformation mechanism. Our experiments reveal twinning and related lattice rotation occurring on the timescale of tens of picoseconds. In addition, despite the common association between twinning and strong shocks, we find a transition from twinning to dislocation-slip-dominated plasticity at high pressure (more than 150 gigapascals), a regime that recovery experiments cannot accurately access. The techniques demonstrated here will be useful for studying shock waves and other high-strain-rate phenomena, as well as a broad range of processes induced by plasticity.

5.
Rev Sci Instrum ; 85(10): 103105, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25362369

RESUMO

An improved dual-gas quasi-phase matching (QPM) foil target for high harmonic generation (HHG) is presented. The target can be setup with 12 individual gas inlets each feeding multiple nozzles separated by a minimum distance of 10 µm. Three-dimensional gas density profiles of these jets were measured using a Mach-Zehnder Interferometer. These measurements reveal how the jets influence the density of gas in adjacent jets and how this leads to increased local gas densities. The analysis shows that the gas profiles of the jets are well defined up to a distance of about 300 µm from the orifice. This target design offers experimental flexibility, not only for HHG/QPM investigations, but also for a wide range of experiments due to the large number of possible jet configurations. We demonstrate the application to controlled phase tuning in the extreme ultraviolet using a 1 kHz-10 mJ-30 fs-laser system where interference between two jets in the spectral range from 17 to 30 nm was observed.

6.
Opt Express ; 22(15): 17607-19, 2014 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-25089381

RESUMO

The potential of borate crystals, BBO, LBO and BiBO, for high average power scaling of optical parametric chirped-pulse amplifiers is investigated. Up-to-date measurements of the absorption coefficients at 515 nm and the thermal conductivities are presented. The measured absorption coefficients are a factor of 10-100 lower than reported by the literature for BBO and LBO. For BBO, a large variation of the absorption coefficients was found between crystals from different manufacturers. The linear and nonlinear absorption coefficients at 515 nm as well as thermal conductivities were determined for the first time for BiBO. Further, different crystal cooling methods are presented. In addition, the limits to power scaling of OPCPAs are discussed.

7.
Opt Lett ; 39(6): 1422-4, 2014 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-24690803

RESUMO

Optical parametric chirped-pulse amplifiers with high average power are possible with novel high-power Yb:YAG amplifiers with kW-level output powers. We demonstrate a compact wavelength-tunable sub-30-fs amplifier with 11.4 W average power with 20.7% pump-to-signal conversion efficiency. For parametric amplification, a beta-barium borate crystal is pumped by a 140 W, 1 ps Yb:YAG InnoSlab amplifier at 3.25 MHz repetition rate. The broadband seed is generated via supercontinuum generation in a YAG crystal.

8.
Opt Express ; 22(2): 1594-607, 2014 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-24515165

RESUMO

A conceptual design of a high power, ultrabroadband optical parametric chirped-pulse amplifier (OPCPA) was carried out comparing nonlinear crystals (LBO and BBO) for 810 nm centered, sub-7.0 fs pulses with energies above 1 mJ. These amplifiers are only possible with a parallel development of kilowatt-level OPCPA-pump amplifiers. It is therefore important to know good strategies to use the available OPCPA-pump energy efficiently. Numerical simulations, including self- and cross-phase modulation, were used to investigate the critical parameters to achieve sufficient spectral and spatial quality. At high output powers, thermal absorption in the nonlinear crystals starts to degrade the output beam quality. Strategies to minimize thermal effects and limits to the maximum average power are discussed.

12.
Nat Commun ; 4: 1731, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23591898

RESUMO

The resolution of ultrafast studies performed at extreme ultraviolet and X-ray free-electron lasers is still limited by shot-to-shot variations of the temporal pulse characteristics. Here we show a versatile single-shot temporal diagnostic tool that allows the determination of the extreme ultraviolet pulse duration and the relative arrival time with respect to an external pump-probe laser pulse. This method is based on time-resolved optical probing of the transient reflectivity change due to linear absorption of the extreme ultraviolet pulse within a solid material. In this work, we present measurements performed at the FLASH free-electron laser. We determine the pulse duration at two distinct wavelengths, yielding (184±14) fs at 41.5 nm and (21±19) fs at 5.5 nm. Furthermore, we demonstrate the feasibility to operate the tool as an online diagnostic by using a 20-nm-thin Si3N4 membrane as target. Our results are supported by detailed numerical and analytical investigations.

13.
Opt Express ; 21(23): 28987-99, 2013 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-24514414

RESUMO

The long-term stability of optical parametric chirped-pulse amplifiers is hindered by thermal path length drifts affecting the temporal pump-to-signal overlap. A kilowatt-pumped burst amplifier is presented delivering broadband 1.4 mJ pulses with a spectral bandwidth supporting sub-7 fs pulse duration. Active temporal overlap control can be achieved by feedback of optical timing signals from cross-correlation or spectral measurements. Using a balanced optical cross-correlator, we achieve a pump-to-signal synchronization with a residual jitter of only (46 ± 2) fs rms. Additionally, we propose passive pump-to-signal stabilization with an intrinsic jitter of (7.0 ± 0.5) fs rms using white-light continuum generation.

14.
Opt Lett ; 37(17): 3672-4, 2012 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-22940986

RESUMO

Attosecond science is enabled by the ability to convert femtosecond near-infrared laser light into coherent harmonics in the extreme ultraviolet spectral range. While attosecond sources have been utilized in experiments that have not demanded high intensities, substantially higher photon flux would provide a natural link to the next significant experimental breakthrough. Numerical simulations of dual-gas high harmonic generation indicate that the output in the cutoff spectral region can be selectively enhanced without disturbing the single-atom gating mechanism. Here, we summarize the results of these simulations and present first experimental findings to support these predictions.

15.
Opt Express ; 20(5): 5038-43, 2012 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-22418308

RESUMO

An Yb:YAG thin-disk multipass laser amplifier system was developed operating in a 10 Hz burst operation mode with 800 µs burst duration and 100 kHz intra-burst repetition rate. Methods for the suppression of parasitic amplified spontaneous emission are presented. The average output pulse energy is up to 44.5 mJ and 820 fs compressed pulse duration. The average power of 4.45 kW during the burst is the highest reported for this type of amplifier.


Assuntos
Amplificadores Eletrônicos , Desenho de Equipamento , Análise de Falha de Equipamento
16.
Phys Rev Lett ; 107(17): 175002, 2011 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-22107529

RESUMO

High harmonic generation (HHG) is a central driver of the rapidly growing field of ultrafast science. We present a novel quasiphase-matching (QPM) concept with a dual-gas multijet target leading, for the first time, to remarkable phase control between multiple HHG sources (>2) within the Rayleigh range. The alternating jet structure with driving and matching zones shows perfect coherent buildup for up to six QPM periods. Although not in the focus of the proof-of-principle studies presented here, we achieved competitive conversion efficiencies already in this early stage of development.

17.
Opt Lett ; 36(13): 2456-8, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21725443

RESUMO

We report on a Yb:YAG Innoslab laser amplifier system for generation of subpicsecond high energy pump pulses for optical parametric chirped pulse amplification (OPCPA) at high repetition rates. Pulse energies of up to 20 mJ (at 12.5 kHz) and repetition rates of up to 100 kHz were attained with pulse durations of 830 fs and average power in excess of 200 W. We further investigate the possibility to use subpicosecond pulses to derive a stable continuum in a YAG crystal for OPCPA seeding.

18.
Opt Lett ; 35(24): 4163-5, 2010 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-21165124

RESUMO

We report on the implementation of a high-count-rate charged particle imaging detector for two-color pump-probe experiments at the free electron laser in Hamburg (FLASH). In doing so, we have developed a procedure for finding the spatial and temporal overlap between the extreme UV free electron laser (FEL) pulses and the IR pulses, which allows for complete alignment of the setup in situations where the region of overlap between the FEL and the IR is not easily accessible by means of imaging optics.

19.
Opt Express ; 18(19): 20242-50, 2010 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-20940915

RESUMO

Significant progress in high repetition rate ultrashort pulse sources based on fiber technology is presented. These systems enable operation at a high repetition rate of up to 500 kHz and high average power in the extreme ultraviolet wavelength range via high harmonic generation in a gas jet. High average power few-cycle pulses of a fiber amplifier pumped optical parametric chirped pulse amplifier are used to produce µW level average power for the strongest harmonic at 42.9 nm at a repetition rate of 96 kHz.


Assuntos
Amplificadores Eletrônicos , Tecnologia de Fibra Óptica/instrumentação , Lasers de Estado Sólido , Desenho de Equipamento , Análise de Falha de Equipamento
20.
Phys Rev Lett ; 104(22): 225001, 2010 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-20867176

RESUMO

By use of high intensity XUV radiation from the FLASH free-electron laser at DESY, we have created highly excited exotic states of matter in solid-density aluminum samples. The XUV intensity is sufficiently high to excite an inner-shell electron from a large fraction of the atoms in the focal region. We show that soft-x-ray emission spectroscopy measurements reveal the electronic temperature and density of this highly excited system immediately after the excitation pulse, with detailed calculations of the electronic structure, based on finite-temperature density functional theory, in good agreement with the experimental results.


Assuntos
Alumínio/química , Elétrons , Processos Fotoquímicos , Gases em Plasma/química , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...