Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Open Forum Infect Dis ; 9(5): ofac160, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35493120

RESUMO

We present a novel case of recurrent brain abscesses found to be the result of a silent congenital right-to-left extracardiac shunt, a persistent left superior vena cava draining into the left atrium. The patient's brain abscess was evacuated surgically and treated with antibiotics, and his shunt was subsequently repaired. The case suggests that attention should be paid to evaluation for shunt physiology allowing for bypass of the pulmonary circulation in those with recurrent brain abscesses.

2.
Rev Med Chil ; 147(4): 458-464, 2019 Apr.
Artigo em Espanhol | MEDLINE | ID: mdl-31344207

RESUMO

BACKGROUND: Placing central venous lines under ultrasonographic guidance reduces the complications of the procedure. AIM: To compare prevalences of complications of central venous line placements with or without ultrasonographic guidance. MATERIAL AND METHODS: Descriptive study that contemplated the comparison of two groups of patients subjected to a central venous line placement at a nephrology service for renal replacement therapy. In one group of 100 patients, the line was placed without ultrasonographic guidance between 2008 and 2012. Between 2015 and 2017 the line was placed in 138 patients using ultrasonographic guidance. The prevalences of complications with both types of procedures were recorded. RESULTS: The frequency of complications of procedures with and without ultrasonographic guidance was 0.7 and 18% respectively (prevalence ratio 0.04, 95% confidence interval 0-0.3). Ninety five percent of recorded complications were arterial puncture, followed by hematomas in 10% and pneumothorax in 5%. The higher prevalence of complications was observed in emergency line placement without ultrasonographic guidance. There was a direct association between the number of line placement attempts in a single procedure and the prevalence of complications. CONCLUSIONS: Ultrasonographic guidance is associated with a reduction in the prevalence of central venous line complications.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/etiologia , Diálise Renal/efeitos adversos , Adulto , Idoso , Cateterismo Venoso Central/instrumentação , Cateterismo Venoso Central/métodos , Chile/epidemiologia , Estudos Transversais , Feminino , Hematoma/epidemiologia , Hematoma/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Pneumotórax/epidemiologia , Pneumotórax/etiologia , Prevalência , Diálise Renal/instrumentação , Diálise Renal/métodos , Distribuição por Sexo , Ultrassonografia de Intervenção/métodos
3.
Rev. méd. Chile ; 147(4): 458-464, abr. 2019. tab
Artigo em Espanhol | LILACS | ID: biblio-1014247

RESUMO

Background: Placing central venous lines under ultrasonographic guidance reduces the complications of the procedure. Aim: To compare prevalences of complications of central venous line placements with or without ultrasonographic guidance. Material and Methods: Descriptive study that contemplated the comparison of two groups of patients subjected to a central venous line placement at a nephrology service for renal replacement therapy. In one group of 100 patients, the line was placed without ultrasonographic guidance between 2008 and 2012. Between 2015 and 2017 the line was placed in 138 patients using ultrasonographic guidance. The prevalences of complications with both types of procedures were recorded. Results: The frequency of complications of procedures with and without ultrasonographic guidance was 0.7 and 18% respectively (prevalence ratio 0.04, 95% confidence interval 0-0.3). Ninety five percent of recorded complications were arterial puncture, followed by hematomas in 10% and pneumothorax in 5%. The higher prevalence of complications was observed in emergency line placement without ultrasonographic guidance. There was a direct association between the number of line placement attempts in a single procedure and the prevalence of complications. Conclusions: Ultrasonographic guidance is associated with a reduction in the prevalence of central venous line complications.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Cateterismo Venoso Central/efeitos adversos , Diálise Renal/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/epidemiologia , Pneumotórax/etiologia , Pneumotórax/epidemiologia , Cateterismo Venoso Central/instrumentação , Cateterismo Venoso Central/métodos , Chile/epidemiologia , Prevalência , Estudos Transversais , Diálise Renal/instrumentação , Diálise Renal/métodos , Ultrassonografia de Intervenção/métodos , Distribuição por Sexo , Hematoma/etiologia , Hematoma/epidemiologia
6.
Pacing Clin Electrophysiol ; 39(8): 858-62, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27197050

RESUMO

BACKGROUND: The impact of inappropriate implantable cardiac defibrillator (ICD) shocks on cardiac outcomes is controversial. Shocks due to lead noise are unique in that they are not an outcome of worsening rhythm status. In this study, we compared the outcome of patients with and without inappropriate shocks who underwent Sprint Fidelis lead (Medtronic Inc., Minneapolis, MN, USA) extraction. METHODS: We retrospectively identified 147 patients who underwent Sprint Fidelis lead extraction in our institution between May 2007 and August 2012. The patients were separated into those with (Group 1) and without (Group 2) inappropriate shocks due to lead noise. Pertinent data were obtained from chart review. RESULTS: There were 57 and 90 patients in Groups 1 and 2, respectively. The mean ± standard deviation number of inappropriate shocks in Group 1 was 16 ± 22. There was no difference in the baseline demographics, risk factors, and cardiac history between the groups. There were no extraction-related deaths and there was no difference in the rate of periprocedural complications between the groups. The mean total hospital length of stay (LOS) was longer for Group 1 versus 2; however, the mean postprocedure LOS was the same between the groups. During follow-up, there was no difference in the cardiac readmission rate over a 1-year period (four vs seven patients in Group 1 vs 2, respectively; P = 0.8). Long-term follow-up revealed similar mortality rates in both groups. (18 patients in Group 1, and 21 patients in Group 2; P = 0.8). CONCLUSIONS: Inappropriate shocks due to lead noise do not seem to predispose to a worse clinical outcome after ICD lead extraction.


Assuntos
Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/prevenção & controle , Distribuição por Idade , Idoso , Causalidade , Comorbidade , Traumatismos por Eletricidade , Feminino , Humanos , Incidência , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Distribuição por Sexo , Taxa de Sobrevida , Resultado do Tratamento , Estados Unidos/epidemiologia
7.
Expert Rev Cardiovasc Ther ; 13(6): 637-41, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26000561

RESUMO

Cardiac catheterization has several risks, notably which include bleeding, stroke and death. The transradial (TR) approach to catheterization is associated with a lower bleeding risk. The right radial approach is the default method in most laboratories and the left radial artery (LRA) serves as the bail-out approach. This article discusses the advantages and disadvantages of transfemoral and TR access routes. The authors envisage an increased adoption of the LRA approach, due to the anatomical superiority and ease of catheter engagement afforded by this approach. The authors discuss ways to increase operator ease for LRA in the laboratory and propose a novel way to improve LRA work-flow.


Assuntos
Cateterismo Cardíaco/métodos , Hemorragia/prevenção & controle , Artéria Radial , Cateterismo Cardíaco/efeitos adversos , Hemorragia/etiologia , Humanos , Acidente Vascular Cerebral/etiologia
8.
Clin Cardiol ; 34(11): 678-80, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21887691

RESUMO

Takotsubo cardiomyopathy (TC) is an uncommon entity. It is known to occur in the setting of extreme catecholamine release and results in left ventricular dysfunction without evidence of angiographically definable coronary artery disease. There have been no published reports of TC occurring with visual stimuli, specifically 3-dimensional (3D) entertainment. We present a 55-year-old woman who presented to her primary care physician's office with extreme palpitations, nausea, vomiting, and malaise <48 hours after watching a 3D action movie at her local theater. Her electrocardiogram demonstrated ST elevations in aVL and V1, prolonged QTc interval, and T-wave inversions in leads I, II, aVL, and V2-V6. Coronary angiography revealed angiographically normal vessels, elevated left ventricular filling pressures, and decreased ejection fraction with a pattern of apical ballooning. The presumed final diagnosis was TC, likely due to visual-auditory-triggered catecholamine release causing impaired coronary microcirculation.


Assuntos
Imageamento Tridimensional/efeitos adversos , Filmes Cinematográficos , Cardiomiopatia de Takotsubo/etiologia , Catecolaminas/metabolismo , Angiografia Coronária , Circulação Coronária , Eletrocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Microcirculação , Pessoa de Meia-Idade , Estimulação Luminosa , Volume Sistólico , Cardiomiopatia de Takotsubo/diagnóstico , Cardiomiopatia de Takotsubo/tratamento farmacológico , Cardiomiopatia de Takotsubo/metabolismo , Cardiomiopatia de Takotsubo/fisiopatologia , Função Ventricular Esquerda
9.
Hypertension ; 45(4): 730-5, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15699464

RESUMO

Previous studies have indicated that the production of 20-hydroxyecisatatraenoic acid (20-HETE) is similar in the liver of C57/B6 mice and rats, but the renal production of 20-HETE is very low in this strain of mice. The present study examined the effects of induction of the renal production of 20-HETE with fenofibrate (FF) on the development of angiotensin II (Ang II)-dependent hypertension in C57BL/6J mice. The mice were divided into 4 groups and treated with vehicle (control), FF (90 mg/kg per day, IP), Ang II (1000 ng/kg per minute, SC), and Ang II plus FF. Mean arterial blood pressure (MAP) averaged 109+/-4 and 106+/-2 mm Hg in control and FF-treated mice (n=7). MAP was significantly increased in the Ang II-treated mice to 144+/-4 mm Hg (n=7). However, FF treatment prevented the development of Ang II-dependent hypertension, with MAP averaging 115+/-5 mm Hg in mice treated with both Ang II plus FF (n=7). Renal production of 20-HETE was very low in control (n=7) and Ang II-treated (n=7) mice and was increased by >2-fold in FF-treated (n=7) and Ang II plus FF-treated (n=7) mice. The levels of Cyp4A proteins were markedly increased in the kidneys of mice treated with FF and Ang II plus FF but not in the renal vasculature. These results suggest that upregulation of the production of 20-HETE in renal tubules may contribute to the blood pressure-lowering effects of FF treatment in Ang II-dependent hypertension in C57BL/6J mice.


Assuntos
Angiotensina II , Fenofibrato/farmacologia , Hipertensão/induzido quimicamente , Hipertensão/prevenção & controle , Vasoconstritores , Angiotensina II/farmacologia , Animais , Pressão Sanguínea/efeitos dos fármacos , Citocromo P-450 CYP4A/metabolismo , Sistema Enzimático do Citocromo P-450/metabolismo , Ácidos Hidroxieicosatetraenoicos/metabolismo , Hipertensão/metabolismo , Hipertensão/fisiopatologia , Rim/efeitos dos fármacos , Rim/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Vasoconstritores/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...