Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Life (Basel) ; 13(2)2023 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-36836627

RESUMO

This study examined the effects of obesity on cartilage mechanics and longitudinal failure probability at the medial tibiofemoral compartment, using combined musculoskeletal simulation and probabilistic failure modelling approaches. The current investigation examined twenty obese females (BMI > 30.0 kg/m2) and 20 healthy weight (BMI < 25.0 kg/m2) females. Walking kinematics were obtained via an 8-camera optoelectric system, and a force plate was used to collect ground reaction forces. Musculoskeletal simulation and probabilistic failure modelling were utilized to explore medial tibiofemoral forces and cartilage probability. Comparisons between groups were undertaken using linear mixed-effects models. Net peak cartilage forces, stress and strain were significantly larger in the obese group (force = 2013.92 N, stress = 3.03 MPa & strain = 0.25), compared to health weight (force = 1493.21 N, stress 2.26 MPa & strain = 0.19). In addition, medial tibiofemoral cartilage failure probability was also significantly larger in the obese group (42.98%) compared to healthy weight (11.63%). The findings from the current investigation show that obesity has a profoundly negative influence on longitudinal medial knee cartilage health and strongly advocates for the implementation of effective weight management programs into long-term musculoskeletal management strategies.

2.
J Clin Med ; 11(24)2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-36555951

RESUMO

This study examined the effects of minimal and conventional running footwear on medial tibiofemoral cartilage mechanics and longitudinal failure probability. The current investigation examined twenty males who habitually ran in minimal footwear and 20 males who habitually ran in conventional footwear. Kinematic data during overground running were collected using a motion-capture system and ground reaction forces using a force plate. Medial tibiofemoral loading was examined using musculoskeletal simulation and cartilage failure probability via probabilistic modelling. In habitual minimal footwear users, peak medial tibiofemoral cartilage force, stress and strain were significantly greater in conventional (force = 7.43 BW, stress = 5.12 MPa and strain = 0.30), compared to minimal footwear (force = 7.11 BW, stress 4.65 MPa and strain = 0.28), though no significant differences in these parameters were evident in non-habitual minimal footwear users (conventional: force = 7.50 BW, stress = 5.05 MPa and strain = 0.30; minimal: force = 7.40 BW, stress = 4.77 MPa and strain = 0.29). However, in both habitual and non-habitual minimal footwear users, the probability of medial tibiofemoral cartilage failure was significantly greater in conventional (habitual = 47.19% and non-habitual = 50.00%) compared to minimal footwear (habitual = 33.18% and non-habitual = 32.81%) users. The observations from this investigation show that compared to minimal footwear, conventional footwear appears to have a negative influence on medial tibiofemoral cartilage health.

3.
Sensors (Basel) ; 22(18)2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-36146352

RESUMO

This two-experiment study aimed to examine the effects of different habitual foot placement angles and also the effects of manipulating the foot placement angle on the kinetics, three-dimensional kinematics and muscle forces of the squat. In experiment 1, seventy lifters completed squats at 70% of their one repetition maximum using a self-preferred placement angle. They were separated based on their habitual foot angle into three groups HIGH, MEDIUM and LOW. In experiment 2, twenty lifters performed squats using the same relative mass in four different foot placement angle conditions (0°, 21°, 42° and control). Three-dimensional kinematics were measured using an eight-camera motion analysis system, ground reaction forces (GRF) using a force platform, and muscle forces using musculoskeletal modelling techniques. In experiment 1, the impulse of the medial GRF, in the descent and ascent phases, was significantly greater in the HIGH group compared to LOW, and in experiment 2 statistically greater in the 42° compared to the 21°, 0° and control conditions. Experiment 2 showed that the control condition statistically increased quadriceps muscle forces in relation to 0°, whereas the 0° condition significantly enhanced gluteus maximus, gastrocnemius and soleus forces compared to control. In experiment 1, patellofemoral joint stress was significantly greater in the HIGH group compared to LOW, and in experiment 2, patellar and patellofemoral loading were statistically greater in the control compared to the 42°, 21°, 0° and control conditions. Owing to the greater medial GRF's, increased foot placement angles may improve physical preparedness for sprint performance and rapid changes of direction. Reducing the foot angle may attenuate the biomechanical mechanisms linked to the aetiology of knee pathologies and to promote gluteus maximus, gastrocnemius and soleus muscular development. As such, though there does not appear to be an optimal foot placement angle, the observations from this study can be utilised by both strength and conditioning and sports therapy practitioners seeking to maximise training and rehabilitative adaptations.


Assuntos
, Postura , Fenômenos Biomecânicos , Humanos , Articulação do Joelho/fisiologia , Extremidade Inferior , Masculino , Músculo Esquelético/fisiologia , Postura/fisiologia
4.
Sports (Basel) ; 10(9)2022 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-36136391

RESUMO

This two-experiment study aimed to explore habitual and manipulated stance widths on squat biomechanics. In experiment one, 70 lifters completed back squats at 70%, 1 repetition maximum (1RM), and were split into groups (NARROW < 1.06 * greater trochanter width (GTW), MID 1.06−1.18 * GTW and WIDE > 1.37 * GTW) according to their self-selected stance width. In experiment two, 20 lifters performed squats at 70%, 1RM, in three conditions (NARROW, MID and WIDE, 1.0, 1.25 and 1.5 * GTW). The three-dimensional kinematics were measured using a motion capture system, ground reaction forces (GRF) using a force platform, and the muscle forces using musculoskeletal modelling. In experiment two, the peak power was significantly greater in the NARROW condition, whereas both experiments showed the medial GRF impulse was significantly greater in the WIDE stance. Experiment two showed the NARROW condition significantly increased the quadriceps forces, whereas both experiments showed that the WIDE stance width significantly enhanced the posterior-chain muscle forces. The NARROW condition may improve the high mechanical power movement performance and promote the quadriceps muscle development. Greater stance widths may improve sprint and rapid change-of-direction performance and promote posterior-chain muscle hypertrophy. Whilst it appears that there is not an optimal stance width, these observations can be utilized by strength and conditioning practitioners seeking to maximize training adaptations.

5.
Acta Bioeng Biomech ; 21(4): 13-25, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32022803

RESUMO

PURPOSE: The current investigation aimed to examine the effects of different orthotic conditions on the biomechanical mechanisms linked to the aetiology of chronic pathologies using musculoskeletal simulation. METHODS: 16 male and 20 females ran over an embedded force plate at 4.0 m/s, in five different conditions (medial, lateral, no-orthoses, semi-custom and off the shelf). Kinematics of the lower extremities were collected using an eight-camera motion capture system and lower extremity joint loading also explored using a musculoskeletal simulation approach. Differences between orthoses conditions were examined using 2 × 2 mixed ANOVA. RESULTS: External instantaneous load rate was significantly reduced in the off the shelf orthoses (male = 1290.60 and female = 1567.10 N/kg/s), compared to the medial (male = 1480.45 and female = 1767.05 N/kg/s) and semi-custom (male = 1552.99 and female = 1704.37 N/kg/s) conditions. In addition, peak patellofemoral stress was significantly lower in the off the shelf orthoses (male = 68.55 and female = 94.91 KPa/kg) compared to the lateral condition (male = 70.49 and female = 103.22 KPa/kg). Finally, peak eversion angles were significantly attenuated in the medial orthoses (male = -6.61 and female = -7.72 deg) compared to the lateral (male = -9.61 and female = -10.32 deg), no-orthoses (male = -8.22 and female = -10.10 deg), semi-custom (male = -8.25 and female = -9.49 deg) and off the shelf (male = -7.54 and female = -8.85 deg) conditions. CONCLUSIONS: The current investigation shows that different orthotic devices/ configurations may provide distinct benefits in terms of their effectiveness in attenuating the biomechanical parameters linked to the aetiology of chronic running injuries.


Assuntos
Simulação por Computador , Extremidade Inferior/fisiologia , Fenômenos Fisiológicos Musculoesqueléticos , Aparelhos Ortopédicos , Corrida/fisiologia , Aceleração , Tendão do Calcâneo/fisiologia , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Articulações/fisiologia , Cinética , Masculino , Rotação , Tíbia/fisiologia
6.
Phys Ther Sport ; 34: 21-27, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30142623

RESUMO

OBJECTIVE: Explore the effects of a 4-week intervention using semi-custom insoles in recreational runners with patellofemoral pain. DESIGN: Mixed methods. PARTICIPANTS: Seventeen (10 males and 7 females) recreational runners. SETTING: Laboratory. OUTCOME MEASUREMENTS: Participants were separated into specific subgroups, then provided with a pair of semi-custom insoles, for a period of 4-weeks. Lower extremity kinetics/kinematics during running at 4.0 m/s were obtained. In addition, knee pain was examined using the Knee injury and Osteoarthritis Outcome Score-Patellofemoral scale (KOOS-PF). Data were collected before and after wearing the insoles for 4-weeks. RESULTS: Significant improvements were shown for KOOS-PF in both subgroups (strong: (pre) = 63.84 & (post) = 71.49 and weak and tight: (pre) = 53.03 & (post) = 72.73), although only improvements in the weak and tight group exceeded the minimum clinically important difference (MCID). In addition, significant reductions in peak patellofemoral stress were shown in both subgroups (strong: (pre) = 6.82 & (post) = 6.39KPa/BW and weak and tight: (pre) = 7.66 & (post) = 6.28KPa/BW), although only reductions in the weak and tight group exceeded the MCID. CONCLUSIONS: Semi-custom insoles may be a mechanism to reduce patellofemoral pain symptoms in recreational runners from the weak and tight subgroup. It is proposed that this improvement was mediated through reductions in patellofemoral loading in this subgroup.


Assuntos
Órtoses do Pé , Manejo da Dor/instrumentação , Síndrome da Dor Patelofemoral/terapia , Corrida/lesões , Sapatos , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
7.
J Hum Kinet ; 46: 19-27, 2015 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-26240645

RESUMO

Electromyography (EMG) is normalized in relation to a reference maximum voluntary contraction (MVC) value. Different normalization techniques are available but the most reliable method for cycling movements is unknown. This study investigated the reliability of different normalization techniques for cycling analyses. Twenty-five male cyclists (age 24.13 ± 2.79 years, body height 176.22 ± 4.87 cm and body mass 67.23 ± 4.19 kg, BMI = 21.70 ± 2.60 kg·m-1) performed different normalization procedures on two occasions, within the same testing session. The rectus femoris, biceps femoris, gastrocnemius and tibialis anterior muscles were examined. Participants performed isometric normalizations (IMVC) using an isokinetic dynamometer. Five minutes of submaximal cycling (180 W) were also undertaken, allowing the mean (DMA) and peak (PDA) activation from each muscle to serve as reference values. Finally, a 10 s cycling sprint (MxDA) trial was undertaken and the highest activation from each muscle was used as the reference value. Differences between reference EMG amplitude, as a function of normalization technique and time, were examined using repeated measures ANOVAs. The test-retest reliability of each technique was also examined using linear regression, intraclass correlations and Cronbach's alpha. The results showed that EMG amplitude differed significantly between normalization techniques for all muscles, with the IMVC and MxDA methods demonstrating the highest amplitudes. The highest levels of reliability were observed for the PDA technique for all muscles; therefore, our results support the utilization of this method for cycling analyses.

8.
Eur J Sport Sci ; 14(8): 799-805, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24754671

RESUMO

Achieving a high ball velocity is important during soccer shooting, as it gives the goalkeeper less time to react, thus improving a player's chance of scoring. This study aimed to identify important technical aspects of kicking linked to the generation of ball velocity using regression analyses. Maximal instep kicks were obtained from 22 academy-level soccer players using a 10-camera motion capture system sampling at 500 Hz. Three-dimensional kinematics of the lower extremity segments were obtained. Regression analysis was used to identify the kinematic parameters associated with the development of ball velocity. A single biomechanical parameter; knee extension velocity of the kicking limb at ball contact Adjusted R(2) = 0.39, p ≤ 0.01 was obtained as a significant predictor of ball-velocity. This study suggests that sagittal plane knee extension velocity is the strongest contributor to ball velocity and potentially overall kicking performance. It is conceivable therefore that players may benefit from exposure to coaching and strength techniques geared towards the improvement of knee extension angular velocity as highlighted in this study.


Assuntos
Futebol/fisiologia , Adolescente , Fenômenos Biomecânicos , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Amplitude de Movimento Articular/fisiologia , Análise de Regressão
9.
J Hum Kinet ; 39: 25-36, 2013 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-24511338

RESUMO

Errors in kinematic data are referred to as noise and are an undesirable portion of any waveform. Noise is typically removed using a low-pass filter which removes the high frequency components of the signal. The selection of an optimal frequency cut-off is very important when processing kinematic information and a number of techniques exists for the determination of an optimal frequency cut-off. Despite the importance of cut-off frequency to the efficacy of kinematic analyses there is currently a paucity of research examining the influence of different cut-off frequencies on the resultant 3-D kinematic waveforms and discrete parameters. Twenty participants ran at 4.0 m•s-1 as lower extremity kinematics in the sagittal, coronal and transverse planes were measured using an eight camera motion analysis system. The data were filtered at a range of cut-off frequencies and the discrete kinematic parameters were examined using repeated measures ANOVA's. The similarity between the raw and filtered waveforms were examined using intra-class correlations. The results show that the cut-off frequency has a significant influence on the discrete kinematic measure across displacement and derivative information in all three planes of rotation. Furthermore, it was also revealed that as the cut-off frequency decreased the attenuation of the kinematic waveforms became more pronounced, particularly in the coronal and transverse planes at the second derivative. In conclusion, this investigation provides new information regarding the influence of digital filtering on lower extremity kinematics and re-emphasizes the importance of selecting the correct cut-off frequency.

10.
J Hum Kinet ; 35: 15-25, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23487393

RESUMO

Three-dimensional (3-D) kinematic analyses are used widely in both sport and clinical examinations. However, this procedure depends on reliable palpation of anatomical landmarks and mal-positioning of markers between sessions may result in improperly defined segment co-ordinate system axes which will produce in-consistent joint rotations. This had led some to question the efficacy of this technique. The aim of the current investigation was to assess the reliability of the anatomical frame definition when quantifying 3-D kinematics of the lower extremities during running. Ten participants completed five successful running trials at 4.0 m·s(-1) ± 5%. 3-D angular joint kinematics parameters from the hip, knee and ankle were collected using an eight camera motion analysis system. Two static calibration trials were captured. The first (test) was conducted prior to the running trials following which anatomical landmarks were removed. The second was obtained following completion of the running trials where anatomical landmarks were re-positioned (retest). Paired samples t-tests were used to compare 3-D kinematic parameters quantified using the two static trials, and intraclass correlations were employed to examine the similarities between the sagittal, coronal and transverse plane waveforms. The results indicate that no significant (p>0.05) differences were found between test and retest 3-D kinematic parameters and strong (R(2)≥0.87) correlations were observed between test and retest waveforms. Based on the results obtained from this investigation, it appears that the anatomical co-ordinate axes of the lower extremities can be defined reliably thus confirming the efficacy of studies using this technique.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...